Electrical Workstation Nvis 7089B

Similar documents
Electrical Workstation Nvis 7089A

VALLIAMMAI ENGINEERING COLLEGE

RAJKIYA ENGINEERING COLLEGE, KANNAUJ

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

MG Electrical Machine. 68 _ ED Co.,Ltd. > EXPERIMENTS > SPECIFICATIONS

Placement Paper For Electrical

STEADY STATE REACTANCE

Hours / 100 Marks Seat No.

Electrical And Electronics Engg

BASIC ELECTRICAL LAB EQUIPMENTS

Conventional Paper-II-2013

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

EE 350: Electric Machinery Fundamentals

Electrical Machines (EE-343) For TE (ELECTRICAL)

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Module 1. Introduction. Version 2 EE IIT, Kharagpur

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

Code No: R Set No. 1

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

UNIT 9 DC Separately-Excited Generator

SYNCHRONOUS MACHINES

Objective: Study of self-excitation characteristics of an induction machine.

ELECTRICAL TECHNOLOGY

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET


Code No: R Set No. 1

1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

INVITATION FOR QUOTATION

1. A battery has an emf of 12.9 volts and supplies a current of 3.5 A. What is the resistance of the circuit?

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Inductance, capacitance and resistance

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

1. Explain in detail the constructional details and working of DC motor.

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Generator Advanced Concepts

DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING 1

A Practical Guide to Free Energy Devices

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

GATE 2000 Electrical Engineering

ECET 211 Electrical Machines and Controls

Conventional Paper-II-2011 Part-1A

ELECTRICAL POWER ENGINEERING

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

S J P N Trust's Hirasugar Institute of Technology, Nidasoshi.

ELECTRICAL ENGINEERING LABORATORY MANUAL (NEE 151/251)

Basic Electrical Engineering Lab Laboratory Manual

IOCL Electrical Engineering Technical Paper

BASIC ELECTRICAL AND ELCTRONICS ENGINEERING LABORATORY LAB MANUAL

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

1. SQUIRREL CAGE AC MOTOR. NO LOAD TEST

2015 ELECTRICAL SCIENCE

Hours / 100 Marks Seat No.

LVSIM-EMS Help Table of Contents

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

ENGINEERING ACADEMY X V

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Preface...x Chapter 1 Electrical Fundamentals

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

EE 340L EXPERIMENT # 3 SYNCHRONOUS GENERATORS

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

DISCUSSION OF FUNDAMENTALS

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Level 6 Graduate Diploma in Engineering Electro techniques

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Unit FE-5 Foundation Electricity: Electrical Machines

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

No. of Printed Pages : 5 ADVANCED LEVEL CERTIFICATE COURSE IN ELECTRICAL ENGINEERING / DIPLOMA IN ELECTRICAL ENGINEERING / ACELVI / DELVI

S4L1S-D4 Wdg.17 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

Anna University of Technology Madurai. Alagar kovil road, Madurai REGULATIONS -2010

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Motor Generator Dynamometer Setup

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Industrial Electrician Level 3

Lesson Plan. Name of the Faculty : Discipline : Electrical Engineering Semester : 4 th Semester. Lesson Plan Duration : Week

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

ELECTRICAL MACHINE LAB. MANUAL : EM II/1

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Types of Generators ACCORDING TO EXCITATION

L T P EE 441: Analog Electronics (EE/IE) (3 1 3) Theory Marks =100 Sessional Marks = 50 Laboratory Marks = 50 Time = 3 hours

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

GATE SOLVED PAPER - EE

Type of loads Active load torque: - Passive load torque :-

Exercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation

TYPICAL QUESTIONS & ANSWERS

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

* 1 [ Contd... BOARD DIPLOMA EXAMINATION, (C 14) OCT/NOV 2015 DEEE THIRD SEMESTER EXAMINATION ENGINEERING MATHEMATICS II

AN ANN BASED FAULT DETECTION ON ALTERNATOR

Manuals. Basic Electrical Engineering BE-104

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

Transcription:

All AC & DC Machines are optional Electrical Workstation offers an excellent approach to the teaching of Electrical Machines principles by introducing a unique modular designed control unit. It provides flexibility for the students to carry out experiments over AC and DC Machines using a large selection of Industry standard inbuilt components. Electrical Machines is one of the most important area of study as it helps users to understand the operational characteristics and working of AC and DC Machines. enables user to put their theory knowledge into practice with ease. There is an additional facility to make wireless connection on workstation with computer and to monitor real time electrical parameters using computer interfacing software. Users can also observe a real time graph between any of the AC and DC electrical parameters on computer. Workstation comprises of separate AC and DC measuring sections equipped with all the necessary instruments such as digital meters, facility to connect AC and DC Supplies along with protection devices such as Fuses, MCB s, Supply Indicators, etc. There are multiple buses provided on the Workstation to make external connections while performing AC and DC Machines Experiments. The design of the control unit ensures to get the highest quality practical experience to user. All the necessary protective measures are taken to avoid fault or danger. Note: All AC & DC Machines along with supporting accessories are available optionally

Features Compatible for Machines upto 3HP Equipped with Measurement Facilities for Experimentation on AC Machines, DC Machines and Transformers Separate AC and DC Measuring Sections Diagrammatic representation of AC and DC Machines for better understanding Rust Free Powder Coating Paint Standard BS terminals, patch cords for safety purpose Terminals provided to obtain Three Phase Fixed as well as Variable AC and DC Supplies with suitable protection High Quality Digital Tachometer for RPM Measurement which is also interfaced with DAQ (Data Acquisition System) s provided with standard Mechanical Loading Arrangement Facility s with aluminum casted Brake-Drum/Pulley with heat suppression facility Machines with Class B Flexible shaft coupling arrangement (Lovejoy) for Generator (MG) Sets Machines provided with Heavy Duty Base/Channel with suitable interconnection Machines provided with suitable protections such as MCB's, Fuses, Generator (MG) Sets provided with coupling protective cover Generator with Electrical Loading Arrangement Facility Durable good quality spring balance Designed by considering all the safety measures Note: All AC & DC Machines along with supporting accessories are available optionally Technical Specifications Electrical Measuring Instruments AC Ammeter (4 Nos.) : Digital Range : 10A AC Voltmeter (4 Nos.) : Digital Range : 450V DC Ammeter (4 Nos.) : Digital Range : 30A DC Voltmeter (4 Nos.) : Digital Range : 300V Single Phase Wattmeter (2 Nos.) : Digital Range : 4kW DC Supply : 300V ± 10% : 2Amp Protective Devices Three Phase MCB (TPN) : 2 Nos. with Mechanical loading arrangement Generator with Electrical loading arrangement

Experiments with DC Machines (optional) DC Shunt Wound Study of Operational Working and Principle of DC Shunt Study of running and reversing phenomenon of DC Shunt Study of No Load Characteristic of DC Shunt Study of Load Characteristic of DC Shunt Study of speed control of DC Shunt using armature voltage control and flux field control method Study and Determine the losses of DC Machine and correspondingly calculate the efficiency of DC Machine by Swinburn's Test Method DC Series Wound Study of Operational Working and Principle of DC Series Study of running and reversing phenomenon of DC Series Study of Load Characteristic of DC Series Study of speed control of DC Series using armature voltage control and flux field control methods DC Compound Wound Study of Operational Working and Principle of DC Compound Study of running and reversing phenomenon of DC Compound Study of Load Characteristic of DC Cumulative- Compound Wound Study of Load Characteristic of DC Differential- Compound Wound DC Shunt Wound Generator Study of Operational Working and Principle of DC Shunt Generator Study and measurement of Open Circuit Characteristic of DC Shunt Generator Study and measurement of External Characteristic of DC Shunt Generator Study and measurement of Internal Characteristic of DC Shunt Generator DC Series Wound Generator Study of Operational Working and Principle of DC Series Wound Generator Study and measurement of Open Circuit Characteristic of DC Series Generator Study and measurement of Load Characteristic of DC Series Generator Study and verify the Field Test of DC Series Machine and correspondingly determine the efficiency of DC Series and Generator at any desire load DC Compound Wound Generator Study of Operational Working and Principle of DC Compound Wound Generator Study and verify the Load Characteristics of Long Shunt Cumulatively Compound Generator Study and verify the Load Characteristics of Short Shunt Cumulatively Compound Generator Study and verify the Load Characteristics of Long Shunt Differentially Compound Generator Study and verify the Load Characteristics of Short Shunt Differentially Compound Generator N Shaft A M Field Motion B B Commutator Carbon brush Rotation of coil anticlockwise S Working Principle of DC Generator Field G C - + Galvanometer

Electrical Workstation AC Machines (optional) Single Phase Capacitor Start Study of Operational Working and Principle of Single Phase Study of Running and Reversing of Single Phase Study of the No-Load Test in a Single Phase Induction Study of the Blocked Rotor Test in a Single Phase Study of Load Test in a Single Phase Three-phase Slip Ring Study of Operational Working and Principle of Three Phase Slip Ring Study of Running and Reversing of Three Phase Study of No Load Test in a Three Phase Study of Block Rotor Test in a Three Phase Induction Measurement of Slip in a Three Phase Study of Load Test in a Three Phase Three-phase Squirrel Cage Study of Operational Working and Principle of Three Phase Squirrel Cage Study of Running and Reversing of Three Phase Study of No Load Test performed in a Three Phase Study of Block Rotor Test performed in a Three Phase Measurement of Slip in a Three Phase Study of Speed-Torque characteristics in a Three Phase Three Phase Salient Pole Synchronous Study of Operational Working and Principle of Three Phase Synchronous Study of V curve of Three Phase Synchronous Study of Inverse V curve of the Three Phase Synchronous Three Phase Transformer: Study of Open Circuit test of Three-Phase Transformer Study of Short Circuit Test of Three-Phase Transformer Study of Three Phase Configurations in Three Phase Transformer Three Phase Salient Pole Synchronous Generator Study of Operational Working Principle of Three Phase Synchronous Generator Study and Measurement of Direct Axis (Xd) Reactance by Slip Test Study and Measurement of Quadrature Axis (Xq) Reactance by Slip Test Study and Measurement of Positive Sequence Impedance of Three Phase Synchronous Generator Study and Measurement of Negative Sequence Impedance of Three Phase Synchronous Generator Study and Measurement of Zero Sequence Impedance of Three Phase Synchronous Generator Study of short circuit characteristics (SCC) of three Phase Synchronous Generator Study of open circuit characteristics (OCC) of three Phase Synchronous Generator Study and measure of voltage regulation of Three Phase Synchronous Generator using EMF Method Study and measure of voltage regulation of Three Phase Synchronous Generator by Direct Loading Single Phase Transformer: Study of Single-Phase Isolation Transformer Study of Single-Phase Step Up Transformer Study of Single-Phase Step Down Transformer Study of Subtractive Polarity of Single Phase Transformer Study of Additive Polarity of Single-Phase Transformer Study of Open Circuit test of Single-Phase Transformer Study of Short Circuit Test of Single-Phase Transformer To determine the Efficiency and Regulation of a Single-Phase Transformer by direct loading at different loading condition. **More than 70 Experiments can be performed in **Also suitable for performing experiments on Basic Electrical Measurements Magnet Brush N S Slip-Rings Working Principle of AC Generator

Technical Specifications of Optional Machines DC s (optional) : Nvis SHM05, Nvis SHM10, Nvis SHM20 & Nvis SHM30 : Shunt Rating : 220V DC ± 5% : Available with 1/2HP, 1HP, 2HP& 3HP : Class 'B Loading arrangement : Mechanical Spring Balance Brake Drum/Pulley : 2Nos.(Tubular ) : A l u m i n u m c a s t e d w i t h h e a t suppression facility : Fuses (mounted at the terminal box of the Machines) : Nvis SM10, Nvis SM20 and Nvis SM30 : Series Rating : 220V DC ± 5% : Available with 1HP, 2HP & 3HP : Class 'B Loading arrangement : Mechanical Spring Balance Brake Drum/Pulley : 2Nos. (Tubular ) : A l u m i n u m c a s t e d w i t h h e a t suppression facility : Fuses (mounted at the terminal box of the Machines) DC s with standard Mechanical loading arrangement : Nvis CM10, Nvis CM20 & Nvis CM30 : Compound : Available with 1HP, 2HP & 3HP Rating : 220V DC ± 5% Loading arrangement : Mechanical Spring Balance : 2Nos.(Tubular ) Brake Drum/Pulley : Aluminum casted with heat suppression facility : Fuses (mounted at the t e r m i n a l b o x o f t h e Machines) Selection Guide Machine Ratings Shunt Series Compound 0.5 HP 1 HP 2 HP 3 HP Nvis SHM05 -- -- Nvis SHM10 Nvis SM10 Nvis CM10 Nvis SHM20 Nvis SM20 Nvis CM20 Nvis SHM30 Nvis SM30 Nvis CM30

AC s (optional) Rating : Nvis SPM10 : Single phase Capacitor Start : Available with 1HP : 230V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% : Class 'B Loading arrangement : Mechanical Spring Balance Brake Drum/Pulley : 2 Nos. (Tubular ) : Aluminum casted with heat suppression facility : Fuses (mounted at the terminal box of the Machines) : Nvis SQM10, Nvis SQM20 & Nvis SQM30 : Three Phase Squirrel Cage : Available with 1HP, 2HP, and 3 HP Rating : 415V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% : Class 'B Loading arrangement : Mechanical Spring Balance Brake Drum/Pulley : 2 Nos. (Tubular ) : Aluminum casted with heat suppression Facility : Fuses (mounted at the terminal box of the Machines) AC s with standard Mechanical loading arrangement : Nvis SRM30 : Three Phase Slip-Ring Induction : 3 HP Rating : 415V AC ± 5% Rated Speed : 1440RPM ± 7.5% Loading arrangement Spring Balance Brake Drum/Pulley : Mechanical : 2Nos.(Tubular ) : Aluminum casted with heat suppression facility Single Phase Transformer (optional) Transformer Specifications Mains Supply Rating : Fuses (mounted at the terminal box of the Machines) : Single Phase, 230V AC ±10%, 50Hz : 1kVA Primary : 0-125V, 0-125V Secondary : 0-125V, 0-125V Rated : 5A Three Phase Transformer (optional) Transformer Specifications Mains Supply Primary Secondary Rated : 415V ±10%, 50Hz : Three Phase : 1kVA : 415V : 230V : 4A Transformer modules Selection Guide Machine Ratings 1 HP 2 HP 3HP Selection Guide Transformer Ratings 1 KVA Three Phase Capacitor Start Three Phase Squirrel Cage Nvis SPM10 Nvis SQM10 -- Nvis SQM20 -- Nvis SQM30 Single Phase Transformer Nvis SPT10 Three Phase Slip-Ring -- -- Nvis SRM30 Three Phase Transformer Nvis TPT10

DC Generators (optional) : Nvis SHG05, Nvis SHG10, Nvis SHG20, and Nvis SHG30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Shunt Rating : 220V DC ± 5% DC Machine (acts as generator) : Shunt : Available with 0.5 HP, 1HP, 2HP and 3HP Shaft extension Loading Arrangement of Coupling : Single Sided : Electrical : Flexible Lovejoy Coupling : Fuses (mounted at the terminal box of the Machines) : Nvis SG10, Nvis SG20 and Nvis SG30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Shunt Rating : 220V DC ± 5% DC Machine (acts as generator) : Series : Available with 1HP, 2HP and 3HP Shaft extension Loading Arrangement of Coupling : Single Sided : Electrical : Flexible Lovejoy Coupling : Fuses(mounted at the terminal box of the Machines) DC s -Generator Set Coupled with Flexible Lovejoy Coupling Lovejoy Coupling : Nvis CG10, Nvis CG20 and Nvis CG30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Compound Rating : 220V DC ± 5% DC Machine (acts as generator) : Compound : Available with 1HP, 2HP and 3HP Shaft extension : Single Sided Loading Arrangement : Electrical of Coupling : Flexible Lovejoy Coupling : Fuses (mounted at the terminal box of the Machines) Selection Guide Machine Ratings Shunt Generator Series Generator Compound Generator 0.5 HP Nvis SHG05 -- -- 1 HP Nvis SHG10 Nvis SG10 Nvis CG10 2 HP Nvis SHG20 Nvis SG20 Nvis CG20 3 HP Nvis SHG30 Nvis SG30 Nvis CG30

AC Generators (optional) : Nvis TPM30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base Three Phase Synchronous Machine : Salient : 3 HP Rating : 415V AC ± 10%, 50Hz Configuration : Delta Connected Rated Speed : 1500RPM ± 5% : Class 'B Excitation : 180Vdc ± 10% DC Machine (acts as generator) : Shunt : 2HP : Class 'B Loading Arrangement : Electrical of Coupling : Flexible Lovejoy Coupling : Fuses (mounted at the terminal box of the Machines) : Nvis TPG30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Shunt : 5HP Rating : 220V DC ± 5% : Class 'B Three Phase Synchronous Machine (acts as generator) : Salient Configuration : "Delta" Connected : 3HP Rating : 415V AC ± 5%, 50Hz Rated Speed : 1500RPM ± 5% : Class 'B Excitation : 180Vdc ± 10% Loading Arrangement : Electrical of Coupling : Flexible Lovejoy Coupling : Fuses (mounted at the terminal box of the Machines) Protective Coupler Cover AC s -Generator Set Coupled with Flexible Lovejoy Coupling : Nvis TP30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine : Shunt : 2HP Rating : 220V DC ± 5% Rated Speed : 1500RPM ± 5% Three Phase Synchronous Machine Configuration Rating : Salient : "Star" Connected : 3HP : 415V AC ± 5%, 50Hz Excitation : 180Vdc ± 10% Loading Arrangement: Electrical of Coupling : Flexible Lovejoy Coupling : Fuses (mounted at the terminal box of the Machines) Selection Guide Machine Ratings Three Phase Synchronous 3 HP Nvis TPM30 Nvis TP30 Nvis TPG30 ** We also offer customized Solutions for different and -Generator Set. Three Phase Synchronous Machine Three Phase Synchronous Generator

Other Supporting Optional Items Single and Three Phase Resistive Load Single Phase Operation : 3.5kW Loading steps : 15 Three Phase Star Operation : 240V AC ±10%, 50Hz : 15A : 5A (per Phase) : 3.5kW Loading steps : 5 (per Phase) Three Phase Delta Operation Loading steps Switching Technique Mains MCB : 15A (per Phase) : 10.5kW : 5 (per Phase) : Star/Delta Switch, 415V, 25A : 16A (TPN) Single and Three Phase Inductive Load Single Phase Operation : 230V AC ±10%, 50Hz : 15A : 4 KVAR Three Phase Star Operation : 4KVAR Three Phase Delta Operation : 5.5A (per Phase) : 15A (per Phase) : 10KVAR Star/Delta Switch : 415V, 25A MCB : 16A Single and Three Phase Capacitive Load Single Phase Operation : 230V AC ±10%, 50Hz Loading steps : 30 Three Phase Star Operation Loading steps : 14A (Approx.) : 4.6A (per Phase) : 10 (per Phase) Three Phase Delta Operation Loading steps Switching Technique Mains MCB : 13A (per Phase) : 10 (per Phase) : Star/Delta Switch, 415V, 25A : 16A (TPN) 10A (One Pole) 30 Nos. Single and Three Phase Resistive Load Single and Three Phase Inductive Load Single and Three Phase Capacitive Load

Thyristorized DC Regulated Supply Input Mains : 415VAC ± 10%, 50Hz Rated Output : 220VDC (Fixed) ± 5%, Rated Output : 50ADC Regulation : Less than 3% at full load condition. Measuring Instruments AC Voltmeter : 1 No. (with voltage selector switch) DC Ammeter : 1 No. DC Voltmeter : 1 No. with its indicators Overload Short Circuit Phase Sequence Indicator Single Phase Variac : Close Operating Rating : 230V AC ±10%, 50Hz Output : 0-270V AC ±10%, 50Hz : 10A (Also available in different Ratings) Three Phase Variac : Close Operating Rating Output : 0-470V AC ±10%, 50Hz : 10A (Also available in different Ratings) Rheostats AC Starters DC Starters Thyristorized DC Regulated Supply Three Phase Variac Single Phase Variac DC Starters AC Starters Rheostats Nvis Technologies Pvt. Ltd. 141-A, Electronic Complex, Pardesipura, Indore-452010, India. +91-731-4211500, info@nvistech.com, www.nvistech.com