Agilent 87075C Multiport Test Set

Similar documents
Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Solutions for Solar Cell and Module Testing

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Process Control Calibration Made Easy with Agilent U1401A

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent NFA Noise Figure Analyzer

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent U9397A/C FET Solid State Switches (SPDT)

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Agilent 8762F Coaxial Switch 75 ohm

Agilent MXG Signal Generators

Agilent J7211A/B/C Attenuation Control Units

Agilent MXG Signal Generators

Agilent Maximizing Measurement Speed Using P-Series Power Meters

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Multipurpose Lab Station by Agilent Technologies

Agilent 8761A/B Microwave Switches


Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

Agilent U1700 Series Handheld LCR Meters

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note

Advanced Test Equipment Rentals ATEC (2832)

Evaluating Oscilloscope Bandwidths for your Application

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent NFA Noise Figure Analyzer

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent 81180A Arbitrary Waveform Generator

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Solar Array Simulation System Integration


Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Agilent InfiniiMax III probing system

Agilent N8700 Series System DC Power Supplies

Agilent N9310A RF Signal Generator

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Agilent ENA 2 and 4 Port RF Network Analyzers

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent N9320B RF Spectrum Analyzer

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent E7400A Series EMC Analyzers

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Agilent PNA Series RF Network Analyzers

Keysight Technologies N9310A RF Signal Generator

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Keysight Technologies N4985A System Amplifiers

Agilent ENA-L RF Network Analyzers

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent U9391C/F/G Comb Generators

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Agilent U1240 Series Handheld Digital Multimeters

Agilent EEsof EDA.

Keysight E5063A ENA Vector Network Analyzer

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Keysight 8762F Coaxial Switch 75 ohm

MXG X-Series Signal Generator N5183B Microwave Analog

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent U8903A Audio Analyzer

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Making a S11 and S21 Measurement Using the Agilent N9340A

MXG Analog Signal Generator Express Configurations

Agilent 86142B and 86146B Optical Spectrum Analyzers

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices

Agilent NFA Noise Figure Analyzer

I-V Curve Characterization in High-Power Solar Cells and Modules

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

Keysight 86205B RF Bridge

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Keysight N9310A RF Signal Generator

Transcription:

Agilent 87075C Multiport Test Set Technical Overview A complete 75 Ω system for cable TV device manufacturers Now, focus on testing, not reconnecting! For use with the Agilent 8711 C-Series of network analyzers 3 MHz to 1.3 GHz Optional two, six, or twelve ports

Get higher device-test throughput with a complete system solution from Agilent System solution for multiport device testing An Agilent Technologies 87075C test set coupled with an Agilent 8711C Series network analyzer offers far more than just switching capability. This complete solution offers fast measurement speed, ease of use, and convenience, as well as vastly improved calibration times (typically a 20 times improvement). The test set and network analyzer are fully specified at the test ports as a system, so your customers can have the most confidence in your products. Plus, you don t have the extra expense of an external computer and the extra development of calibration and control software to worry about with an 8711 C-Series analyzer you get full internal switching and calibration control of the test system. Quickly and completely characterize your devices with a single connection The Agilent test system eliminates time-consuming reconnections of a device to a two-port network analyzer to test all its signal paths. By saving time, you keep your costs down and your volumes up so you can remain competitive in the fast-growing cable- TV device manufacturing industry. 2 Improve your device throughput and test accuracy An Agilent 87075C test set coupled with an 8711 C-Series RF network analyzer offers: Significant improvements in calibration time and the accuracy of your measurements, all with a single connection Local area networking capability and advanced automation capabilities for local and distributed control The 8711 C-Series of RF network analyzers designed for high-volume production LAN capability Efficiently send new test parameters, test limit lines, and gather test data from your production line IBASIC Optional built-in BASIC instrumentcontroller for easy automation Pass/fail testing Automated pass/fail testing instantly and consistently compares measured data to your test limits Large 9-inch display See test results on a large easy-toread display The 87075C multiport test set Designed to improve your device throughput 3 MHz to 1.3 GHz, 75 Ω Aimed at testing cable-tv devices Innovative SelfCal technique For fast, accurate measurements Solid-state switching For reliable, repeatable, and fastswitching Optional two, six, or twelve port test sets To meet all your multiport devicetest needs

Get fast, accurate measurements with an unprecedented calibration technique New SelfCal technique With its advanced internally automated calibration capability, the 87075C is shipped from Agilent already calibrated at all measurement ports. You can use this default testset calibration or complete your own test-set calibration. Now, between test-set calibrations, the system can be calibrated in a few seconds on-line with SelfCal. SelfCal uses transfer standards located inside the test set to bring the system to the same measurement-accuracy level as your test-set calibration. You save all the time previously required to connect the external standards, which is typically a 20-time improvement. Reduce system-calibration time A typical calibration time is one hour per shift per instrument for a monthly total of about 20 hours. SelfCal reduces this time to approximately 1 hour per month! You can easily set up the calibration intervals, so the analyzer does the work automatically. Cut your system-calibration time by up to 20 times with the innovative SelfCal technique. Reduce the number of RF connections The 87075C test set provides switching capability to all measurement ports, which reduces RF interconnects. Connect your device only once, and quickly and easily measure all its signal paths and ports. By reducing the number of RF connections you also: Decrease tune-and-test times Reduce operator fatigue Lower risk of misconnection Reduce wear on cables, fixtures, connectors, and the device under test Increase customer confidence in your products with a fully specified system For RF measurements, the calibration and RF specifications must be at the actual measurement ports. The 87075C coupled with an 8711 C-Series analyzer offers a fully specified test system. Now you can correlate measurements across different test systems, and reduce your measurement uncertainties, which means you can tighten your product specifications and increase your competitiveness! Agilent fully specifies the network analyzer and test set as a system so you have a complete measurement platform. 3

Designed for cable TV multiport device manufacturing Taps and splitters The 87075C multiport test set can be used with a quick-connect fixture to allow fast and easy high-volume testing of the frequency response, return loss, and isolation between all tap and splitter ports. Distribution and trunk/bridger amplifiers Use the Agilent multiport test system to test forward-and-reverse frequency response, gain, and slope as well as return loss on all amplifier ports. You can also test the isolation between all the amplifier s outputs. Cable TV distribution system showing typical multiport devices that can be measured with the Agilent 87075C multiport test set and 8711 C-Series network analyzer system 4

The Agilent multiport test system helps you: Reduce the number of connections by providing switching capability for the required number of measurement ports Reduce the time necessary for calibration with an innovative calibration technique with installation and on-line calibration (SelfCal) Get a fully specified system at the RF measurement ports for a verifiable interface Compatibility The 87075C multiport test set is comatible with the 8711C, 8712C, 8713C and 8714C RF network analyzers configured with the 75-Ω Option 1EC. The Agilent 87075C multiport test set coupled with the 8711 C-Series of RF network analyzer helps you get high device throughput. 5

Additional productivity and ease-of-use features LAN connection for system networking Optional local-area-network (LAN) connectivity provides a complete interface to your test-processmanagement software systems. The Agilent 8711 C-Series provides the improved device analysis and dataarchival requirements that customers and regulatory agencies demand. Make forward and reverse measurements with a T/R network analyzer By using an external multiport test set like the 87075C with an 8711C, both forward and reverse transmission and reflection measurements can be made with a single connection. Easy programming for automation With the Agilent 8711C Instrument BASIC (IBASIC) option, you get a full- featured, built-in instrument controller for fast, flexible, and complete measurement customization. Even if you don t have programming experience, you can use IBASIC to perform complex computation and control to record keystrokes and automate your manual measurements. Large display and external VGA monitor Your technicians and operators will appreciate how the large display of the analyzer enhances their ability to see measurement information in your manufacturing environment. You can also connect an analyzer to a standard VGA monitor and see measurement results in color on an even larger and easier-to-read screen. In this example, a two-port test set allows a transmission/reflectionbased network analyzer to make measurements in both forward and reverse directions. Rear-panel connectivity LAN capability GPIB, Centronics parallel, and RS-232C serial interfaces VGA output TTL-level signal for part-handlercontrol DIN Interface 6

Agilent 87075C specifications and characteristics 1 Frequency range Noise floor 2 Receiver dynamic range Measurement dynamic range 3 Connector type Maximum test port power Measurement Level Damage Level Port-to-port isolation Port-to-port insertion loss Reflection to Port n Port n to Transmission Multiport system residuals Transmission Measurement Source Match Corrected Uncorrected Load match Reflection Measurement Directivity Source Match Corrected Uncorrected Load Match 3 MHz to 1300 MHz 84 dbm See 8711 C-Series data sheet 60 db Type-N Female, 75 Ω +16 dbm +20 dbm 60 db 6 db 7 db 30 db 14 db 16 db 40 db 30 db 14 db 20 db Port Switching Time Test Set Settling Time SelfCal calibration time 4 Reflection Transmission Line power Frequency Voltage Cabinet dimensions Weight Net Shipping Environmental 1 second 10 msec 2 seconds 4 seconds 50/60 Hz 100/120/220/240 V 132.8 mm H x 425 mm W x 495 mm D 7.7 kg 11.3 kg General conditions ESD (electrostatic discharge) must be eliminated by use of static-safe work procedures and an antistatic bench mat. Operating temperature 0 to 55 C (Indoor use only) Altitude 0 to 4,600 m (15,000 ft) Storage temperature 40 C to +70 C 1. This part provides several types of performance information: Specifications describe the test set s warranted performance over a temperature range of 20 C to 30 C, unless otherwise stated. Supplemental Characteristics (indicated by italics) are typical, but nonguaranteed parameters, intended to provide useful information in using the product. The following conditions must be met for the test set to meet its specifications: The test set must be used with an Agilent 8711C, 8712C, 8713C or 8714C network analyzer (with 1-MByte SRAM and firmware revision 4.5 or later). The analyzer must have had its performance verified within the last year. Both instruments must be warmed up for at least 30 minutes after turn-on. A valid test-set calibration must have been performed on the system within the last 30 days using valid standards. A SelfCal must have been performed by the system within the last 60 minutes. 2. Medium-wide system bandwidth. 3. Limited by port-to-port isolation. 4. Assumes 201-point measurement, medium-system bandwidth. 7

Ordering information Agilent 87075C multiport test set Includes: Power cord, test-set calibration disk as well as: 87075-60026 Interconnect cable (reflection port) 87075-60028 Interconnect cable (transmission port) 8120-6818 Parallel port interface cable 87075-90005 87075C User s and Service Guide Standard options (Must order one of the following options with 87075C) Option 002 Two-port system Option 006 Six-port system Option 012 Twelve-port system Other options Option 1CM Rack-mount kit Includes: 87075-60027 Interconnect cable (reflection port) 87075-60029 Interconnect cable (transmission port) (These cables are shipped with Option 1CM only. Use these cables if you are rack-mounting your system, or if the bottom feet of the analyzer have been removed.) Option UK6 Commercial calibration certificate with data Option 002 87075-60026 87075-60028 8120-6818 Also available (order separately) Cables 8120-2408 75 Ω Type-N to Type-N cable (M-M) 8120-2409 75 Ω Type-N to Type-N cable (M-F) 8120-8396 75 Ω Type-N to Type-F cable (M-M) 8120-8397 75 Ω Type-N to Type-F cable (M-F) Precision adapters 85039-60010 Type-N (M) to Type-F (M) 85039-60011* Type-N (F) to Type-F (M) 85039-60013* Type-N (M) to Type-F (F) 85039-60014 Type-N (F) to Type-F (F) 85039-60002* Type-F (F) to Type-F (F) 85039-60006* Type-F (M) to Type-F (M) 85039-60012 Type-F (M) to Type-F (F) *included in 85039B Commercial adapters 1250-2350 Type-F (F) to Type-F (F) 1250-2369 Type-N (M) to Type-F (M) 1250-2368 Type-N (F) to Type-F (M) Calibration kits HP 85039B 75 Ω Type-F calibration kit Option 00M Male standards only Option 00F Female standards only HP 85036B 75 Ω Type-N calibration kit HP 85036E Economy 75 Ω Type-N calibration kit Related products Agilent 87075A/B custom multiport test sets. See literature number 5964-3830E for further information. Multiple switching test sets are also available through Agilent s special handling. Option 002 Option 006 Option 012 8120-2408 8120-2409 8120-8396 8120-8397 85039-60002 85039-60006 85039-60012 85039-60010 85039-60011 85039-60013 85039-60014 1250-2350 1250-2369 1250-2368 8

www.agilent.com Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt Product specifications and descriptions in this document subject to change without notice. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 24, 2009 Agilent Technologies, Inc. 2009 Printed in USA, April 3, 2009 5965-8165E