ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD

Similar documents
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SOCIETY OF CABLE TELECOMMUNICATIONS ENGINEERS INC

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Measurement Procedure for Noise Power Ratio

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method For Coaxial Cable Impedance

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Hybrid Management Sub-Layer Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Procedure for Hum Modulation

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Microwave. Accessories for Microwave Scalar and System Analyzers

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

Advanced Test Equipment Rentals ATEC (2832)

Current Probes. User Manual

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Log Periodic Dipole Array Antenna

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

NRSC-2 Emission Limitation for AM Broadcast Transmission June, 1988

Contents. CALIBRATION PROCEDURE NI PXIe-5698

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

This is a preview - click here to buy the full publication

PXIe Contents. Required Software CALIBRATION PROCEDURE

Circuit Characterization with the Agilent 8714 VNA

Advanced Test Equipment Rentals ATEC (2832)

NATIONAL RADIO SYSTEMS COMMITTEE

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

Screening Attenuation of Long Cables

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

Spectrum Analyzers 2680 Series Features & benefits

Model BiConiLog Antenna. User Manual

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

AMERICAN NATIONAL STANDARD

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

Copyright Teletronics International, Inc. Patent Pending

TELESTE AC NODE SPECIFIC MODULES

10 GHz Microwave Link

Model 3180B Mini-Bicon Antenna User Manual

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

ECC Recommendation (16)04

rf link 870 mhz mini-bridger

BDA Broadband Drop Amplifier

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Diamond Line Type 1 and Type 2 Amplifiers

INTERNATIONAL STANDARD

Compact Nodes and 90071

Model 3140B BiConiLog Antenna User Manual

750 MHz Magnamax series

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

The Precision Spherical Dipole Source

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

BluePhase 1000 PHASE NOISE TEST SYSTEM. Operations Manual

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

SWR/Return Loss Measurements Using System IIA

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

Shielding Effectiveness Report HQDP

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

TELESTE AC AMPLIFIER MODULES

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Diamond Line 3 Single Output Amplifiers

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

TIA-527 Balanced Optical/Electrical Converter. Operating Instructions

DSA700 Series Spectrum Analyzer

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

Microwave Circuit Design and Measurements Lab. INTRODUCTION TO MICROWAVE MEASUREMENTS: DETECTION OF RF POWER AND STANDING WAVES Lab #2

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Model 6940 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

Broadband System - J

Comparison of IC Conducted Emission Measurement Methods

BDA Broadband Drop Amplifier

Documentation. PerfectPulse Fast Edge Signal Generator

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-5663E

Measuring Photonic, Optoelectronic and Electro optic S parameters using an advanced photonic module

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

Transcription:

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 48-2 2008 Test Procedure for Measuring Relative Shielding Properties of Active and Passive Coaxial Cable Devices Using Agilent Magnetic Close Field Probe

NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability and ultimately the long term reliability of broadband communications facilities. These documents shall not in any way preclude any member or nonmember of SCTE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE members, whether used domestically or internationally. SCTE assumes no obligations or liability whatsoever to any party who may adopt the Standards. Such adopting party assumes all risks associated with adoption of these Standards, and accepts full responsibility for any damage and/or claims arising from the adoption of such Standards. Attention is called to the possibility that implementation of this standard may require the use of subject matter covered by patent rights. By publication of this standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE shall not be responsible for identifying patents for which a license may be required or for conducting inquiries into the legal validity or scope of those patents that are brought to its attention. Patent holders who believe that they hold patents which are essential to the implementation of this standard have been requested to provide information about those patents and any related licensing terms and conditions. Any such declarations made before or after publication of this document are available on the SCTE web site at http://www.scte.org. All Rights Reserved Society of Cable Telecommunications Engineers, Inc. 2008 140 Philips Road Exton, PA 19341 i

TABLE OF CONTENTS 1.0 SCOPE/DISCLAIMER...1 2.0 CAUTION AND WARNINGS...2 3.0 THE PROBE...2 4.0 THEORY OF OPERATION...3 5.0 EQUIPMENT REQUIRED...3 6.0 POST AMPLIFIER AND "K" FACTOR...5 7.0 TEST PROCEDURE...6 LIST OF FIGURES FIGURE 1: NEAR FIELD PROBE VIEWS 1 FIGURE 2: PROBE SENSITIVITY 3 FIGURE 3: RFI SCALAR NETWORK ANALYZER TEST SET 4 FIGURE 4: RFI TRACKING GENERATOR/ANALYZER TEST SETUP 4 FIGURE 5: RFI MODULATOR-SIGNAL LEVEL METER SETUP 5 FIGURE 6: 50 Ω TO 75 Ω TYPE "N" TRANSITION 6 FIGURE 7A: DIRECT OR MINIMUM LOSS PAD CALIBRATION 7 FIGURE 8: -30DBMV ON SCREEN DISPLAY 8 FIGURE 9: SPECTRUM ANALYZER DISPLAY 9 FIGURE 10: TYPICAL SCALAR TEST SETUP 10 FIGURE 11: PHYSICAL SEPARATION TO PREVENT FALSE READINGS 11 FIGURE 11B: OPERATIONAL CHECK 11 FIGURE 12: INDOOR SPLITTER 12 ii

FIGURE 13: FOUR-PORT DROP AMPLIFIER 13 FIGURE 14: TRUNK/BRIDGER AMPLIFIER HIGHEST SIGNAL POINT 14 FIGURE 15: SHOWS THE PROBE BEING HELD WITH THE LONG TIP EDGE PARALLEL TO AN AMPLIFIER HOUSING LID SEAL. 15 FIGURE 15B: SHOWS A READING OF -115DB (-75DB + 40DB K FACTOR)15 FIGURE 16: PROBE TIP HELD PARALLEL TO CABLE/CORD 15 iii

1.0 SCOPE/DISCLAIMER Hewlett-Packard is a registered trademark of AGILENT Corp. This document is intended to outline the use of the Agilent 10940A/10941A Close Field probes (or similar devices) in determining the Relative Shielding Effectiveness of various cable telecommunication system devices. Throughout this document are details, paraphrasing, formulae and procedures derived from various Hewlett-Packard printed documents, used with their permission, but with no acknowledgement or responsibility as to their accuracy or suitability with regards their applicability to the intended measurement result. All procedures and conclusions are those of the authors of this document. This document outlines the procedures for determining the relative Shielding Effectiveness of cable telecommunication system devices employing a combination of Close Field probes and various Scalar Test equipment packages, through the use of defined, repeatable test practices. For clarity, the various models of close field probes are hereinafter referred to as the probe. Figure 1 HP 11940/41 NEAR FIELD PROBE VIEWS 50 OHM SMA ANTENNA FACTOR LABEL CONNECTOR Figure 1 FIGURE 1: Near Field Probe Views 1

2.0 CAUTION AND WARNINGS 2.1 The tests proposed in this document involve the use of RF Signal levels which could be damaging or destructive to some cable telecommunication system equipment. Read all procedures completely before beginning any testing. After testing, restore test equipment settings to safe levels to avoid inadvertent problems with future tests. If in doubt, consult the equipment manufacturer for approval prior to testing. 2.2 This procedure may suggest the direct interconnection of 50 Ω and 75 Ω devices. RF implications aside, such interconnections must only be performed with a universally mechanically compatible connector type, such as "BNC". Under no circumstances may 50 Ω and 75 Ω type "N" connectors be interconnected. Connecting a 75 Ω type "N" Male connector to a 50 Ω type "N" Female connector results in no contact. Connecting a 50 Ω type "N" Male connector to a 75 Ω type "N" Female connector results in the destruction of the female type "N" connector. 3.0 THE PROBE The Probe is a Balanced Magnetic Field sensor, which delivers an output voltage dependent on the Magnetic or "H" field present. The Probe senses magnetic fields through two printed circuit loops at the probe tip. Maximum sensitivity is orthogonal to the long edge of the Probe tip as shown in Figure 2. Available probe types are employed depending on the frequency range to be tested. Usually Probes are classified as High or Low Frequency 30 MHz to 1 GHz and 5-30 MHz. Most available probes are 50 Ω devices, which can present some operational difficulties when employed with conventional cable telecommunication system 75 Ω test equipment. Adaptation of these devices to 75 Ω systems is detailed in the "Set-up and Calibration" section 7.1. 2

MAXIMUM SENSITIVITY PROBE SENSITIVITY MAXIMUM SENSITIVITY Figure 2 FIGURE 2: Probe Sensitivity 4.0 THEORY OF OPERATION Theoretically, every source of Electromagnetic Radiation must be comprised of both a Magnetic (or "H") field, and an Electric (or "E") Field. While the absolute correlation between the magnitude of the Magnetic field detected, and the absolute magnitude of the radiated Electromagnetic field is dependent on many factors, there is a direct Relative relationship between the two. Any improvement in suppression of the "H" field results in a corresponding reduction in the Open Air Electromagnetic radiated field strength. For purposes of this document, most cable telecommunication system operators have accepted that Near Field measurement capabilities of at least than 100 db lower than the highest internal signal level are required, and this procedure is intended to allow measurements in excess of 120 db. 5.0 EQUIPMENT REQUIRED 5.1 Scalar Signal Level Measurement test setup having the following capabilities: A signal transmitter, operating over the desired frequency range, with an output capability of 2 mw (+51.75 dbmv). A signal detector, capable of receiving signals lower in level than 2 pw (-40 dbmv). For convenience, a swept test system is recommended, although a tunable single frequency setup can be employed. Some typical swept equipment configurations are: 3

1: Scalar Network Analyzer (Agilent 871*) Series or equivalent. (Figure 3) 2: Spectrum Analyzer with Tracking Generator Agilent 8591 OPT 11, Agilent 85640A (Figure 4) 3: Analog Cable Sweep system If only a Tunable Single Frequency setup is considered, then the equipment should consist of: (Figure 5) 1: Agile Modulator or variable signal generator 2: Signal Level Meter or Spectrum Analyzer. RFI SCALAR NETWORK ANALYZER TEST SET Figure 3 TRANSMITTER RECEIVER FIGURE 3: RFI Scalar Network Analyzer Test Set RFI TRACKING GENERATOR/ANALYZER TEST SETUP Figure 4 3.0 2.0 1.5 1.0.6.4.3-12 -9-6 -3 0 TRANSMITTER RECEIVER FIGURE 4: RFI Tracking Generator/Analyzer Test Setup 4

+24 +12 +5-8 MODEL POWER WAVELENGTH BANDWIDTH MAX TEST -30dB SLOPE MAX LEVEL MAJOR ALARM MODEL TSM LASER CONTROL MODULE LAST ENTER NEXT LEFT/RIGHT MODEL +24 +12 +5 POWER SUPPLY TYPE WAVELENGTH BANDWIDTH POWER TEST RX MAX TEST -30dB SLOPE MAX LEVEL RFI MODULATOR-SIGNAL LEVEL METER SETUP Figure 5 TRANSMITTER RECEIVER FIGURE 5: RFI Modulator-Signal Level Meter Setup 5.2 Post Amplifier having the following capabilities: Gain 42 to 47 db (+/- 1 db) across the desired frequency band. As this amplifier will be operating at very low RF levels, it can be safely built up of two amplifiers cascaded. As an example, two close coupled 30 db gain Line amplifiers, with ~10 db interstage attenuation pads will suffice. 5.3 Highly shielded interconnect cables and "F" Terminators. Due to the very sensitive nature of this test, it is imperative that the cable or interconnect employed between the transmission device and the device to be tested have a leakage suppression at least 20 db better than the target measurement. Where physically feasible, depending on the form factor and mass of the device to be tested, the ideal test condition is a direct Connector interconnect between the device under test and the transmission device. This can involve connecting small light devices such as splitters directly to the transmission port with a connector adapter. If this type of connection is not possible, then a multiple shield or semi-rigid cable interconnect is required. All connectors and terminators should be threaded type (avoid push-on connectors) and torqued to 30 in/lb. 6.0 POST AMPLIFIER AND "K" FACTOR The total gain or loss between the Probe and the Receiving device is referred to as the "K" factor. For ease of measurement, the "K" factor should be an even number, with 40 db being ideal. The Probe is a 50 Ω device, and if directly connected to a 75 Ω load, will exhibit a Return Loss of 14dB, and a signal transformation apparent Voltage Gain of +1.75 db. While this value expressed as a decimal is somewhat irrelevant in the context of a 120 db dynamic range test, it is included for sake of accuracy. The Return Loss is irrelevant in this measurement. Alternatively, a Minimum Loss Pad having a loss of 5.7 db may be employed between the Probe and the Post Amplifier if absolute accuracy is demanded. 5

If a direct connection is to be employed (NOTE THE WARNING CONCERNING "N" CONNECTOR MATING), then the Post amplifier should be set up to 38.25 db flat gain across the band of interest. The net result will be a "K" factor of 40 db. If a Minimum Loss Pad is employed, the amplifier should be set to 45.7 db gain, again resulting in a 40 db "K" factor. Figure 6 TO RECEIVER POST AMPLIFIER 1.75dB VOLTAGE GAIN HP 11940/41 Figure 6 50/75 OHM ADAPTER 5.7dB LOSS HP 11940/41 MINIMUM LOSS PAD 7.0 TEST PROCEDURE FIGURE 6: 50 Ω to 75 Ω type "N" Transition NOTE: Due to the extremely low recovered signal levels and high dynamic range employed in this test, it is practically impossible to achieve measurement accuracy closer than +/- 3 db. As will be seen however, in a test for relative level ratios in excess of 100 db, this error is insignificant. 7.1 SET-UP AND CALIBRATION With the test equipment set to a safe drive level (+20 dbmv Max), sweep and align the Post Amplifier to a flat gain +/-0.75 db of either 38.5 or 45.7 db, depending on the Probe interconnect manner to be employed. (Figure 7, typically shown in the detailed response of Figure 7A.) 6

FIGURE 7: RFI Post Amplifier Set-up db 55.5 1:Transmission &M Log Mag 5.0 db/ Ref 50.50 db C? 2:Off Meas1:Mkr3 870.000 MHz 45.601dB 1: 45.5 40.5 2 3 35.5 30.5 25.5 1 4 1 M1 20.5 15.5 Start 0.300 MHz Stop 1 000.000 MHz 1:Mkr (MHz) db 2:Mkr (MHz) db 1: 5.0000 33.129 2: 55.0000 44.372 3> 870.0000 45.601 4: 1000.0000 31.244 Figure 7A FIGURE 7A: Direct or Minimum Loss Pad Calibration RFI POST AMPLIFIER SET-UP 38.5 db or 45.7 db Gain Figure 7 POST AMPLIFIER 7

Disconnect the Post Amplifier from the Measurement equipment and set aside. Set the test equipment transmission level to +50 dbmv, and establish a receive reference of +50 dbmv. On a Scalar Analyzer, this can be accomplished by setting the received +50 dbmv at the top line of the display and storing the trace. On a Spectrum Analyzer, set the received +50 dbmv at the top line of the display and note the Attenuator setting. In either case, a display setting of 10 db/div is desirable. It is now necessary to locate the 30 dbmv reference point. If using a Scalar analyzer having 10 Graticule divisions of 10 db/div on screen range, this point is 8 divisions below the reference. (Figure 8) 1: db -10 1:Transmission &M Log Mag 10.0 db/ Ref 1.25 db C? 2:Off Meas1:Mkr3 870.000 MHz M1-88.986dB -20-30 -40-50 -60-70 -80 3 1-90 Rel 4 1 2 Start 0.300 MHz Stop 1 000.000 MHz FIGURE 8: -30dBmV On Screen Display If using a device such as a Spectrum analyzer or Signal Level meter having less Dynamic Range, the reference point can be established by using 20-40 db of input attenuation during the 50 dbmv reference stage, and then removing the attenuation during the test phase. The received level will then be equal to the display plus the amount of attenuation removed. (Figure 9) 8

SPECTRUM ANALYZER DISPLAY 0dB +50dBmV Reference through 40dB pad -40dB -40dB with pad removed is actually -80dB Figure 9 Reference -80dB - Post Amp Gain =Reference - 120dB FIGURE 9: Spectrum Analyzer Display For example: if the receive device has only 40 db of dynamic range, then set the +50 dbmv reference through a 40 db attenuator. When the attenuator is removed, the 40 db display will be (+50 dbmv 40 db 40 db = -30 dbmv) Connect the Probe to the Post Amplifier Input and connect the Post Amplifier output to the receive device. The 30 dbmv reference point is now 120 db below the +50 dbmv reference. 7.2 PREVENTING FALSE READINGS Connect the proposed transmission cable or connector to the signal transmission port. (Figure 10) 9

HP 8712ET Network Analyzer REFERENCE AT +50.00dBmV DISPLAY AT 10dB/DIV ADD AMP GAIN TO MEASURED VALUE 862MHz Amplifier 40dB K FACTOR DRIVE DEVICE TO +50dBmV AT HIGHEST SIGNAL LEVEL POINT RFI Probe HP 11940A TERMINATED TEST LEAD PROBE PHYSICALLY CONTACTING DEVICE MEASURE ALL JOINTS AND CONNECTORS AT ALL ORIENTATIONS OF PROBE Figure 10 FIGURE 10: Typical Scalar Test Setup Bring the Probe near the open end of the transmission cable and note that significant signal is received. This is a quick determination that the system is operating correctly. An example is seen as the upper trace in Figure 11B. Terminate the transmission cable, and move the Probe tip all over the transmission cable, connectors, test equipment face, and power cords, and note that no signals are received higher than the 30 dbmv reference. This will establish that the system is not generating leakage prior to device testing. If signals above the 30 dbmv level are noted, replace cables and connectors, or extend cables to move the transmission equipment further away from the test area. 10

HP 8712ET Network Analyzer SEPARATE TEST EQUIPMENT AND DUT TO PREVENT FALSE READINGS Figure 11 POST AMPLIFIER LENGTH OF PROBE LEAD 6FT (2M) RFI Probe HP 11940A Device under Test Power Source FIGURE 11: Physical Separation to prevent False Readings 1: db -10 1:Transmission &M Log Mag 10.0 db/ Ref 1.25 db C? 2:Off Meas1:Mkr3 870.000 MHz -94.473dB -20-30 -40-50 -60-70 M1-80 -90 3 1 Rel 4 1 Start 2 0.300 MHz Stop 1 000.000 MHz Figure 11B FIGURE 11B: Operational Check Once the test setup is established with no readings above the 30 dbmv reference, we now have a 120 db capable measurement setup. 11

7.3 DETERMINING THE DEVICE UNDER TEST (DUT) MAXIMUM SIGNAL LEVEL POINT This test involves driving the DUT so as to achieve a signal level of +50 dbmv at the highest level point within the device. This signal level will not harm conventional cable telecommunication system actives or passive devices, but Ultra Low Noise or Optical devices may be damaged. Before performing this test on such devices, approval of the equipment supplier should be obtained. The highest signal level point in the DUT can be determined from the block diagram or schematic. It is the intent of this test procedure to apply an input signal level that will drive the highest signal point to +50 dbmv. Some examples are: 7.3.1 Splitter The Highest Level Point in a passive splitter is the input port. Figure 12 HIGHEST SIGNAL POINT 4 WAY SPLITTER Figure 12 FIGURE 12: Indoor Splitter 12

7.3.2 Four Port Drop Amplifier The Highest Level Point is the output of the gain stage prior to the output splitter (Figure 13) RF INPUT HIGHEST SIGNAL POINT RF OUTPUT 4 PORT DROP AMP Figure 13 FIGURE 13: Four-Port Drop Amplifier 7.3.3 Line Amplifier The Highest Level Point will be the output of the Post Amplifier hybrid prior to any diplex filtering or splitting. Figure 14 13

HIGHEST SIGNAL POINT LEVEL SLOPE BRIDGER OUTPUT OUTPUT Figure 14 HYBRID INPUT INPUT EQUALIZER INPUT HYBRID LEVEL SLOPE TRUNK OUTPUT OUTPUT ATTENUATOR HYBRID HYBRID TRUNK/BRIDGER AMPLIFIER HIGHEST SIGNAL POINT 7.4 Measurement Technique FIGURE 14: Trunk/Bridger Amplifier Highest Signal Point Set equipment as in Figure 11. The Standard method is to have the non-conductive Probe tip in physical contact with the DUT. Should the particular user's test specification require spacing the Probe Tip some defined distance from the DUT, a non-metallic, non-conductive spacer may be fabricated from LEXAN or similar material, to ensure a consistent spacing. Such spacing should be noted in the final report form. An example of such spacer is shown in Appendix A. 7.4.1 Set the transmission level so as to drive the DUT Highest Level Point to +50 dbmv. 7.4.2 Probe all openings or potential leakage points on the device with particular attention to slots and seams, which are most likely to exhibit a "Slot Antenna" effect. 7.4.3 Use the Probe at all orientations but with specific attention to testing with the long edge of the probe parallel to any lengthwise openings or joints. Figure 15 Figure 15 14

FIGURE 15: Shows the probe being held with the long tip edge parallel to an amplifier housing lid seal. 1: db -10 1:Memory Log Mag 10.0 db/ Ref 1.25 db C? 2:Off Meas1:Mkr3 870.000 MHz -74.643dB -20-30 -40-50 -60-70 3-80 M1-90 2 4 Rel 1 Start 0.300 MHz Stop 1 000.000 MHz Figure 15B FIGURE 15B: Shows a reading of 115 db (-75 db + 40 db K factor) If the device being tested incorporates a powering cord or lead, probe along the lead for at least 6 ft (2 m) from the device. The antenna effect of a cable can result in a leakage hot spot some distance from the device being tested. The Probe tip should be held parallel to the cable or cord as in Figure 16. Figure 16 FIGURE 16: Probe Tip Held Parallel to cable/cord 15

Depending on the Test Equipment being employed, several items should be noted: When employing a Tracking Generator or other slow sweep, the Probe should be held in each test location for one complete sweep across the frequency band. When employing a Single Frequency test setup, the test should be repeated at 50MHz intervals across the frequency band. 16

ANSI/SCTE 48-2 RFI Near Field Test Summary Date Tested By Equipment Setup Transmitter Receiver Equipment under Test Post Amplifier Post K Factor DUT Max RF Level Probe Tip Spacing Probe Model Number Displayed RFI Corrected RFI RFI Location on DUT Frequency General Test Environment : Temperature, Relative Humidity and Altitude (ASL) Sketch or Photo if Req,d 17

APPENDIX A PROBE SPACER 18