Coils Loop sensors / radiating loops / Helmholtz coils

Similar documents
MGA Magnetic field system. DC khz

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Loop & Magnetic Field Coil

Coupling/Decoupling Networks (CDN)

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Schlöder GmbH - EMC Test and Measurement Systems Model #

Voltage Transient Emission Test

Surge Generator for MIL-STD 1275

RADIATED IMMUNITY TEST SYSTEMS

Conduit measured transfer impedance and shielding effectiveness (typically achieved in the RS103 and CS114 tests)

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

CS114 + CS115 + CS116

Double-Ridged Waveguide Horn

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

NEAR FIELD MEASURING MEASURING SET-UP. LANGER E M V - T e c h n i k

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Current clamps for AC current

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Electromagnetic Compatibility

ISO INTERNATIONAL STANDARD

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Flexible AC current probes

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

CMC 14 Common Mode Chokes Series

SAC-10 Plus Triton Class

Advanced Test Equipment Rentals ATEC (2832)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BL series Miniature paddle joystick controllers

EMC Near-field Probes + Wideband Amplifier

R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications

A A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET

Advanced Test Equipment Rentals ATEC (2832)

Coupling / decoupling network (CDN) for screened or coaxial cables

Double-Ridged Waveguide Horn

FISCHER CUSTOM COMMUNICATIONS, INC.

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

E MC Ane c hoi c Chambers

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

BH series Paddle joystick controllers

Exposure Level Tester ELT-400

A E 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 500 W (source) 150 W (sink) DATA SHEET

Ferronato Helmholtz Coils

Common Impedance Shield Coupling

The Reliable Source... FERROPERM. Inductors. Transformers

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Microphones & Accessories

Coupling/Decoupling Networks (CDN)

Saturation of Active Loop Antennas

TETRIS 1000 High Impedance Active Probe. Instruction Manual

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Acceleration Sensor AS - 022

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

F1A Magnetic Field Transducers

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Senturion XPR04 Proximity Probe

Application Note # 5438

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Solution of EMI Problems from Operation of Variable-Frequency Drives

thin and flexible probes factory calibration certificate with traceability High precision Analog output: DC 35 khz (depending on probe type)

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Safety Evaluation Within a Magnetic Field Environment

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

We re In The Business Of Making Your Life Easier

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

A QE 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 1000 W (source) 650 W (sink) DATA SHEET

EMC Precompliance Systems and Accessories Catalog

19998-WK 8pp 3255/3260 6/9/00 11:57 am Page B Precision Magnetics Analyzer 3255B Inductance Analyzer 3265B 25A Bias Unit

MONITORING DEVICE 4 khz to 400 MHz

Electron Spin Resonance v2.0

Ultrasonic level transmitter, non-contact

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

University of Florida Non-Contact Energy Delivery for PV System and Wireless Charging Applications

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Specification for Conducted Emission Test

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Network Analyzer for Low-, Medium- and High-Voltage Networks

P331-2 set ESD generator (IEC )

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

CX1100 Series Current and Differential Sensors

Current Probes. User Manual

AIM & THURLBY THANDAR INSTRUMENTS

F3A Magnetic Field Transducers

Bulk Current Injection Probe Test Procedure

TxBlock-USB Transmitter

High-precision process calibrator Model CED7000

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

Transcription:

Coils Loop sensors / radiating loops / Helmholtz coils Loop sensors / radiating loops: page 2 Helmholtz coils: page 6 Coils_F - 44/05 Page 1 of 10

Coils according to MIL-STD-461E Loop sensor / radiating loop LS_040: Electrostatically shielded loop sensor according to MIL-STD-461E RL_120: 120mm radiating loop according to MIL-STD-461E LS_133: Electrostatically shielded loop sensor according to MIL-STD-461E LS_040 with connecting cable RL_120 with connecting cable Coils_F - 44/05 Page 2 of 10

For calibration purpose the LS_040 is attached onto the RL_120. The distance of 5 cm between radiating loop and field monitoring loop is guaranteed automatically. LS_133 with connecting cable Positioning facility with 3 polymer threaded rods at the front side. Coils_F - 44/05 Page 3 of 10

Coil according to EN 55103-1/2 Loop sensor / radiating loop RLS_133: Electrostatically shielded loop sensor according to EN 55103-1/2. For economical reasons this coil is used as radiating loop and loop sensor as well. RLS_133 with connecting cable Positioning facility with 3 polymer threaded rods at the front side. Coils_F - 44/05 Page 4 of 10

Specifications Model LS_040 RL_120 LS_133 RLS_133 Loop sensor / Type: Loop sensor Radiating loop Loop sensor radiating loop Standard: MIL-STD-461E RS101 MIL-STD-461E RS101 MIL-STD-461E RE101 EN 55103-1/2 Diameter: 40 mm 120 mm 133 mm 133 mm Body material: PVC MDF MDF MDF Wire: 7-41 Litz wire 2,0mm Magnet wire 7-41 Litz wire 0,25 mm² Litz wire Number of turns: 51 20 36 36 Number of layers: 1 4 4 4 Shielding: Elektrostatic none Elektrostatic Elektrostatic Distance to EUT: 5 cm 5 cm 7 cm 10 cm / 5 cm Connector at coil: Speakon 4 mm MC socket Speakon Speakon Connector at cable: XLR 4 mm MC plug XLR XLR / 4 mm MC plug Coil factor (50 mm): --- 76,3 1/m --- 138,5 1/m Correction factor: see calibration sheet (50 Ω / 600 Ω / 1MΩ) --- see calibration sheet (50 Ω / 600 Ω / 1MΩ) see calibration sheet (50 Ω / 600 Ω / 1MΩ) DC resistance: ~ 4,5 Ω ~ 0,05 Ω ~ 10 Ω ~ 1,1 Ω Inductance: ~ 130 µh ~ 120 µh ~ 340 µh ~ 340 µh Resonant frequency: --- > 1,8 MHz --- > 0,9 MHz Frequency range: 10 Hz - 1 MHz DC - 500 khz 10 Hz - 1 MHz DC / 10 Hz - 500 khz Nominal current: --- 15 A --- 5 A Connecting cable: Microphone cable Litz wire 2 x 1,5mm² Microphone cable Microphone cable / Litz wire 2 x 1,5mm² Volume of delivery: Coil LS_040 Cable, 3m Calibration sheet Coil RL_120 Cable, 3m Calibration sheet Coil LS_133 Cable, 3m Calibration sheet Coil RLS_133 2 Pcs. Cable á 3m Calibration sheet Coils_F - 44/05 Page 5 of 10

Helmholtz Coils for susceptibility tests HCST_50/28_TAP Tapped triaxial Helmholtz coil Tapped single axis and triaxial Helmholtz coils For immunity tests according to MIL-STD-461E, EN 55103-2, SAE J1113-22 etc. Tapped single layer winding resulting in large coil factors for tests with low frequencies and low inductance for tests with high frequencies. For the generation of magnetic fields with field strength > 1000 A/m Coils_F - 44/05 Page 6 of 10

General The typical single axis Helmholtz coil system consists of two identical wound coils, wired in series. The magnetic field between and in the center of the coils is extremely uniform. At fixed dimension the strength of the magnetic field generated is directly proportional to the number of turns in the coils and the current applied to them. A high number of turns leads to a high coil factor. The higher the coil factor, the lower the current (and thus the amplifier power) to maintain a specific field strength. However, if higher frequencies are required (e.g. MIL-STD-461E requires 100 khz), the coil impedance will require impracticable high driving voltages to drive enough current through the coil in order to reach the desired field intensity. It is a common feature of all immunity standards that the required field intensity decreases with increasing frequency. The afore mentioned MIL-STD-461E e.g. requires 1000 μt at 60 Hz and 0,63 μt at 100 khz. The best solution to bypass these problems is the construction of tapped Helmholtz coils. The basic design is shown in the subsequent drawing. COIL 1 COIL 2 Wind. 1 Wind. 2 Wind. 2 Wind. 1 Blue socket White socket Brown sockets Magenta socket Black socket Connecting the output of a power amplifier to the blue socket and black socket leads to a Helmholtz coil with a high coil factor - best for the generation of high field strength at low frequencies, where the coil inductance has no or little influence. Connecting the output of a power amplifier to the white socket and magenta socket leads to a Helmholtz coil with low inductance - best for the generation of medium field strength at high frequencies. With Helmholtz coil configurations of greater complexity the disturbing magnetic fields are generated in different directions. Systems that consist of three coil pairs (triaxial Helmholtz coil) generate the magnetic vector in the X-, Y- and Z-direction. With a corresponding generator/analyzer it is possible to control the EUT fully automated across a wide frequency range without the need to turn it. Coils_F - 44/05 Page 7 of 10

HCS_50/28_TAP Helmholtz coil with loop sensor RLS_133 General assembly of HCS coils Helmholtz coils of the HCS series are constructed completely of wooden materials. Metallic components are limited to the copper wire and electrical connectors. The copper wire is covered with heavy duty laminate. The wire is not visible and therefore protected against damaging. The volume of delivery contains cabling (length 3 m) designed for the maximum current rating of the coils. Coils_F - 44/05 Page 8 of 10

Specifications (All coils are customized so the subsequent data are only exemplary.) Model HCS_50/28_TAP HCS_100/60_TAP HCST_50/28_TAP Type Monaxial Monaxial Triaxial Dimension [cm] 50 100 50 / 46 / 42 Number of turns (per coil) 22 + 4 44 + 10 22 + 4 Coil separation [cm] 28 60 28 Coil factor [m -1 ] 65,9 / 11,2 61,3 / 10,3 X-axis: 66,1 / 11,3 Y-axis: 67,8 / 11,8 Z-axis: 69,1 / 12,2 Total resistance DC [ ] 0,63 / 0,15 10,5/2,0 X-axis: 0,58 / 0,10 Y-axis: 0,53 / 0,09 Z-axis: 0,48 / 0,08 Total inductance [mh] 1,73 / 0,07 6,2 / 1,2 X-axis: 1,73 / 0,07 Y-axis: 1,52 / 0,06 Z-axis: 1,33 / 0,05 Resonant frequency [khz] > 150 khz > 150 khz > 150 khz Rated current [A] 16 16 16 Short term current [A] 20 20 20 Coils_F - 44/05 Page 9 of 10