Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Similar documents
Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

Load Cells LOAD CELLS

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

Model TMS DIN-Flange Torque Measurement System DESCRIPTION APPLICATIONS FEATURES

Quadrature Speed and Direction Sensors. SNG-Q Series. Datasheet

Model TS. Transducer Simulator User s Guide. Sensotec Sensors

Issue D. Installation Instructions for the Quadrature Speed and Direction Sensors SNG-Q Series. Sensing and Internet of Things

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

WOI Series. Limitless Wireless Operator Interface DESCRIPTION

Hall-effect Position Sensors with Sealed Housing The 103SR Series Hall-effect position sensor assemblies are sealed in aluminum or stainless-steel thr

Heavy Duty Pressure Transducers

SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Limitless Wireless Multi-Protocol Receiver WMPR Series Issue 2. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

SS421 Series. Solid State Hall-effect Sensors Adjustable Hall-Effect Under-speed Detectors

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Miniature pressure sensor

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

TRANSDUCER IN-LINE AMPLIFIER

Characteristic Condition Min. Typ. Max. Unit. Response time 3 µs Output voltage swing: VOM- VOM+ 0.4 V s - 0.4

XPC10 High temperature miniature pressure sensor

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Signal Conditioning Amplifier

Load Cell Accessories and Services

Pressure Transducer FP2000

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Non-Submersible Industrial Pressure Transducer

PX2 Series Heavy Duty Pressure Transducer

PX2 Series Heavy Duty Pressure Transducer

Application Sheet How to Apply Honeywell APS00B Angular Position Sensor ICs

Sensor Datasheet Collection

Installation Instructions for the Transportation Attitude Reference Sensor TARS Series

TRANSDUCER IN-LINE AMPLIFIER

Broadband Current Probe Series Operation Manual

MODEL 3810/2 Line Impedance Stabilization Network

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

HOD /BBA HOD /BBA

Torque Sensor Accessories and Services

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Advanced Test Equipment Rentals ATEC (2832)

Model C STRAIN GAGE LOAD CELL. Installation and Operating Manual

Installation Instructions for the Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU)

STT 3000 Smart Temperature Transmitter

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Broadband Current Probe Series Operation Manual

Angular Rate Sensor. Owner's Manual

1523, 1524 Thermometer Readout User s Guide

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

ELPF Load Cell DESCRIPTION

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

HOD /BBA HOD /BBA

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL

Bipolar, Latching, or Unipolar Digital Hall-effect Sensor ICs: SS400 Series, SS500 Series

PCO-7114 Laser Diode Driver Module Operation Manual

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

PNP. 5 to 800 mm sensor to reflector distance on BRT-60x40C NPN

o-ring grease can be used to hold the o-ring in the groove during installation.

Instruction Manual. HB Series Mini Level Sensor

U5300 Industrial Pressure Transducer

TORQUE SENSOR AND FORCE SENSOR

A4200/A4600 Load Cell Mounting Kit Installation

Distribution Amplifiers 1

Force Sensors. FSA Series, Compensated/Amplified. Datasheet

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Issue B. Bipolar, Latching, and Unipolar Hall-effect Digital Position Sensor ICs: SS400 Series, SS500 Series

PSW-002. Fiber Optic Polarization Switch. User Guide

Limitless Wireless Multi-Protocol Receiver. WMPR Series. Datasheet

MODEL AT-10 ANALOG TRANSMITTER

ZT-4 Tonnage Load Module By Toledo Integrated Systems User s Manual

M5200 Industrial Pressure Transducer

80i-600A AC Current Probe

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

LX Series Part-Sensing Light Screen

Rotary Position Sensor Line Guide

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

TORQUE. Quick-ship program - torque

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

o-ring grease can be used to hold the o-ring in the groove during installation.

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

742A Series Resistance Standards

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

Transcription:

Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making them an ideal choice for in-line compression measurement or tension measurement where side loading cannot be completely controlled. The flexible mounting options make applications easier to implement, and the all stainless steel, hermetic construction is well suited to corrosive and very high humidity environments. FEATURES 2000 lb to 50000 lb range Male/female threads Stainless steel, all-welded construction 1 mv/v nominal (standard); 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs (optional) Compression/tension 0.25 % accuracy CE approved 10

PERFORMANCE SPECIFICATIONS Load ranges 11 2000, 3000, 4000, 5000, 10000, 15000, 25000, 50000 lb Accuracy ±0.25 % full scale 1 Linearity Hysteresis Non-repeatability Output (tolerance) Operation Resolution ±0.25 % full scale ±0.25 % full scale ± 0.05 % full scale 1 mv/v (nominal) Tension/compression Infinite RANGE CODES Range Code DL DN DP DR DV EJ EM EP Available ranges 2000 lb 3000 lb 4000 lb 5000 lb 10000 lb 15000 lb 25000 lb 50000 lb ENVIRONMENTAL SPECIFICATIONS Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, span ELECTRICAL SPECIFICATIONS Strain gage type Excitation (calibration) Excitation (acceptable) Insulation resistance Bridge resistance (tolerance) Shunt calibration data Electrical termination (std) -54 C to 121 C [-65 F to 250 F] 15 C to 71 C [60 F to 160 F] 0.005 % full scale/ F 0.005 % full scale/ F Bonded foil 10 Vdc Up to 15 Vdc or Vac 5000 mohm @ 50 Vdc 700 ohm Included MECHANICAL SPECIFICATIONS PTIH-10-6P or equivalent (hermetic stainless) Maximum allowable load 150 % FS 1 Case material Life cycles (approx) Deflection full scale Stainless steel >10 million cycles 0,076 mm [0.003 in] WIRING CODES Connector A B C D E F Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output DEFLECTIONS AND RINGING FREQUENCIES Capacity (lb) Deflection at full scale mm [in] Ringing frequency (Hz) Weight kg [lb] 2000 0,025 [0.001] 10000 0,55 [1.2] 3000 0,025 [0.001] 12000 0,55 [1.2] 4000 0.038 [0.0015] 13000 0,59 [1.3] 5000 0,050 [0.002] 15000 0,63 [1.4] 10000 0,050 [0.002] 10000 1,3 [2.9] 15000 0,050 [0.002] 10000 1,3 [2.9] 25000 0,050 [0.002] 6500 4,3 [9.5] 50000 0,076 [0.003] 7000 4,3 [9.5] 2 Honeywell Sensing and Control

INTERNAL AMPLIFIERS Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Output signal ±5 V 0 V to 5 V or ±5 V @ 45 ma Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 4,5,6 ±15 V or 26 Vdc to 32 Vdc Rod End In-Line Compression/Tension Load Cell Voltage output: Option 2t 0 V to 10 V or ±10 V @ 45 ma Current threewire: Option 2j Current twowire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return Bl Output common G Supply return B Output common** C Supply return ** Bl Output common* G Supply return* B Output common** C Supply return** Bl Output common* G Supply return* B Output common** C Supply return** Bl Output common* G Supply return* * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00. B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground ALLOWABLE MAXIMUM LOADS 2 Capacity (lb) Side load (lb) (% of load capacity) 2000 20 % 20 % 3000 20 % 20 % 4000 20 % 20 % 5000 20 % 20 % 10000 20 % 20 % 15000 20 % 20 % 25000 20 % 20 % 50000 20 % 20 % Torque (lb-in) (% of load capacity) Honeywell Sensing and Control 3

OPTION CODES Load ranges Temperature compensation Internal amplifiers Internal amp enhancements Electrical termination Shunt calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http:// sensing.honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) (ranges 50000 lb and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E- 14S-6), (max. 160 F) (ranges above 50000 lb) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance Zero and span adjustment Electrical connector orientation Shock and vibration 12b. 5000 ohm (foil) (max. 250 F) 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 8 53t. TEDS IEEE 1451.4 module 9 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 13 2t. 0 Vdc to 10 Vdc output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable 4 Honeywell Sensing and Control

Rod End In-Line Compression/Tension Load Cell MOUNTING DIMENSIONS Unamplified only Amplified only Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in] 2000 to 5000 44,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] 10000 to 15000 63,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 114,3 [4.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] 25000 to 50000 88,9 [3.50] 2-12 UNF 57,15 [2.25] 146,05 [5.75] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] TYPICAL SYSTEM DIAGRAM Honeywell Sensing and Control 5

Rod End In-Line Compression/Tension Load Cell NOTES 1. Allowable maximum loads maximum load to be applied without damage. 2 2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma three-wire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Termination dependent; consult factory. 11. This unit calibrated to Imperial (non-metric) units. 12. 5000 ohm bridge required. Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell s test and measurement products, call +1-614-850-5000, visit www.honeywell.com/sensotec, or e-mail inquiries to info.tm@honeywell.com Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008658-2-EN IL50 GLO January 2010 Copyright 2010 Honeywell International Inc. All rights reserved.