Piezoelectric Fiber Composite Ultrasonic Transducers for Guided Wave Structural Health Monitoring

Similar documents
Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems

Excitation and reception of pure shear horizontal waves by

Abstract. 1 Introduction. 1.2 Concept. 1.1 Problematic. 1.3 Modelling

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves.

Rayleigh Wave Interaction and Mode Conversion in a Delamination

COMPOSITES FROM PIEZOELECTRIC FIBERS AS SENSORS AND EMITTERS FOR ACOUSTIC APPLICATIONS*

DEVELOPMENT OF STABILIZED AND HIGH SENSITIVE OPTICAL FI- BER ACOUSTIC EMISSION SYSTEM AND ITS APPLICATION

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves.

ULTRASOUND IN CFRP DETECTED BY ADVANCED OPTICAL FIBER SENSOR FOR COMPOSITE STRUCTURAL HEALTH MONITORING

MEASUREMENT OF SURFACE ACOUSTIC WAVE USING AIR COUPLED TRANSDUCER AND LASER DOPPLER VIBROMETER

Instantaneous Baseline Damage Detection using a Low Power Guided Waves System

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Co-Located Triangulation for Damage Position

EWGAE 2010 Vienna, 8th to 10th September

DAMAGE-TYPE IDENTIFICATION IN A CFRP CROSS-PLY LAMINATE FROM ACOUSTIC EMISSION SIGNALS DETECTED BY A FIBER-OPTIC SENSOR IN A NEW REMOTE CONFIGURATION

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

In-Situ Damage Detection of Composites Structures using Lamb Wave Methods

Electronic Noise Effects on Fundamental Lamb-Mode Acoustic Emission Signal Arrival Times Determined Using Wavelet Transform Results

Assessment of lamination defect near the inner surface based on quasi-symmetric circumferential Lamb waves

Remote Sensing ISSN

Investigation of interaction of the Lamb wave with delamination type defect in GLARE composite using air-coupled ultrasonic technique

A Wire-Guided Transducer for Acoustic Emission Sensing

Selective Excitation of Lamb Wave Modes in Thin Aluminium Plates using Bonded Piezoceramics: Fem Modelling and Measurements

Ultrasonic Guided Wave Testing of Cylindrical Bars

ULTRASONIC GUIDED WAVES FOR AGING WIRE INSULATION ASSESSMENT

APPLICATION OF ULTRASONIC GUIDED WAVES FOR INVESTIGATION OF COMPOSITE CONSTRUCTIONAL COMPONENTS OF TIDAL POWER PLANTS

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

A New Elastic-wave-based NDT System for Imaging Defects inside Concrete Structures

ACOUSTIC EMISSION MEASUREMENTS ON SHELL STRUCTURES WITH DIRECTLY ATTACHED PIEZO-CERAMIC

Theoretical and Experimental Investigation of Fiber Bragg Gratings With Different Lengths for Ultrasonic Detection

A Detailed Examination of Waveforms from Multiple Sensors on a Composite Pressure Vessel (COPV)

Passive Polymer. Figure 1 (a) and (b). Diagram of a 1-3 composite (left) and a 2-2 composite (right).

Title: Reference-free Structural Health Monitoring for Detecting Delamination in Composite Plates

Keywords: Guided wave, structural health monitoring, HCSS, disbond, damage index. More Info at Open Access Database

Flow Front and Cure Monitoring for Resin Transfer Molding Using Ultrasonic Guided Waves in Cylindrical Wires

Multi-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays

Piezoelectric Sensors and Actuators

Experimental and theoretical investigation of edge waves propagation and scattering in a thick plate with surface-breaking crack-like defect

Characterization of Silicon-based Ultrasonic Nozzles

PIEZOELECTRIC WAFER ACTIVE SENSORS FOR STRUCTURAL HEALTH MONITORING STATE OF THE ART AND FUTURE DIRECTIONS

Liquid sensor probe using reflecting SH-SAW delay line

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

ON LAMB MODES AS A FUNCTION OF ACOUSTIC EMISSION SOURCE RISE TIME #

SHM of CFRP-structures with impedance spectroscopy and Lamb waves

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

vibro-acoustic modulation

Acoustic Emission Signals versus Propagation Direction for Hybrid Composite Layup with Large Stiffness Differences versus Direction

Research on An Inspection Method for De-bond Defects in Aluminum. Skin-Honeycomb Core Sandwich Structure with Guided Waves

Multiple crack detection of pipes using PZT-based guided waves

OPTIMAL EXCITATION FREQUENCY FOR DELAMINATION IDENTIFICATION OF LAMINATED BEAMS USING A 0 LAMB MODE

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

Validation of a Lamb Wave-Based Structural Health Monitoring System for Aircraft Applications

CIRCULAR LAMB AND LINEAR SHEAR HORIZONTAL GUIDED WAVE ARRAYS FOR STRUCTURAL HEALTH MONITORING

Piezo-electric Thick Films for Sensing

Long Range Guided Wave Monitoring of Rail Track

MODELING AND EXPERIMENTATION OF THICKNESS MODE E/M IMPEDANCE AND RAYLEIGH WAVE PROPAGATION FOR PIEZOELECTRIC WAFER ACTIVE SENSORS ON THICK PLATES

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves

DAMAGE IN CARBON FIBRE COMPOSITES: THE DISCRIMINATION OF ACOUSTIC EMISSION SIGNALS USING FREQUENCY

Air Coupled Ultrasonic Inspection of Steel Rubber Interface

Ginzton Laboratory, W. W. Hansen Laboratories of Physics Stanford University, Stanford, CA 94305

Determination of the width of an axisymmetric deposit on a metallic pipe by means of Lamb type guided modes

Finite element simulation of photoacoustic fiber optic sensors for surface rust detection on a steel rod

RODS AND TUBES AS AE WAVEGUIDES

ABSTRACT 1. INTRODUCTION

Use of parabolic reflector to amplify in-air signals generated during impact-echo testing

SELECTION OF MATERIALS AND SENSORS FOR HEALTH MONITORING OF COMPOSITE STRUCTURES

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

ONLINE DAMAGE MONITORING FOR HIGH-SPEED TRAIN BOGIE USING GUIDED WAVES: DEVELOPMENT AND VALIDATION

Research Article An Investigation of Structural Damage Location Based on Ultrasonic Excitation-Fiber Bragg Grating Detection

A New Lamb-Wave Based NDT System for Detection and Identification of Defects in Composites

ELASTIC WAVE EMISSION DURING DELAMINATION GROWTH OF CARBON/EPOXY MONITORED WITH FIBER-OPTIC DEFEW STRAIN RATE SENSOR

Design of a Piezoelectric-based Structural Health Monitoring System for Damage Detection in Composite Materials

Quasi-Rayleigh Waves in Butt-Welded Thick Steel Plate

Dynamic Strain Measurement Using Improved Bonding Fiber Bragg Grating

UNDERSTANDING THE PROPAGATION OF GUIDED ULTRASONIC WAVES IN UNDAMAGED COMPOSITE PLATES

Change in Time-of-Flight of Longitudinal (axisymmetric) wave modes due to Lamination in Steel pipes

Theory and Applications of Frequency Domain Laser Ultrasonics

FATIGUE CRACK GROWTH MONITORING OF AN ALUMINUM JOINT STRUCTURE

Ultrasonic Guided Waves for NDT and SHM

Proceedings Piezoelectric Actuators for In-Liquid Particle Manipulation in Microfluidic Applications

PRACTICAL ASPECTS OF ACOUSTIC EMISSION SOURCE LOCATION BY A WAVELET TRANSFORM

SOME OBSERVATIONS ON RAYLEIGH WAVES AND ACOUSTIC EMISSION IN THICK STEEL PLATES #

Development of High Temperature Acoustic Emission Sensing System Using Fiber Bragg Grating

Proceedings of Meetings on Acoustics

Experimental Vibration-based Damage Detection in Aluminum Plates and Blocks Using Acoustic Emission Responses

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

ANALYSIS OF ACOUSTIC EMISSION FROM IMPACT AND FRACTURE OF CFRP LAMINATES

Finite Element Analysis and Test of an Ultrasonic Compound Horn

1272. Phase-controlled vibrational laser percussion drilling

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

MATERIALS CHARACTERIZATION USING LASER ULTRASONIC GUIDED WAVES

Piezoelectric Generator for Powering Remote Sensing Networks

Monitoring Network for SHM in Avionic Applications

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Transcription:

More Info at Open Access Database www.ndt.net/?id=15125 Piezoelectric Fiber Composite Ultrasonic Transducers for Guided Wave Structural Health Monitoring Ching-Chung Yin a, Jing-Shi Chen b, Yu-Shyan Liu c and Shih-Ming Hsu d Department of Mechanical Engineering, National Chiao Tung University 11 Ta Hsueh Road, Hsinchu 31, Taiwan, R.O.C. a ccyin@mail.nctu.edu.tw, b jschen9@gmail.com, c ysliu@itri.org.tw, d hsm186@gmail.com Keywords: Structural health monitoring, ultrasonic transducer, guided wave, piezoelectric fiber composite. Abstract. This paper presents the characterization of a low-voltage high-frequency piezoelectric fiber composite (PFC) transducer for guided wave structural health monitoring applications. The PFCs with interdigital electrodes have been utilized as smart material sensors and actuators. The structural guided waves exhibit complicated multimodal dispersive behavior. It has resulted in a need that the transducers can launch and sense guided waves of specific frequency or wavelength propagating through the host structure. The devised PFC transducer is poled symmetrically with respect to its mid-plane and thereafter activated by anti-symmetrically aligned interdigital electrodes. Directional Lamb waves can be generated at the frequency, nearly one megahertz, which corresponds to the fundamental extensional resonance of PFC alone. The directivity patterns of free A and S Lamb modes transmitted by the PFC transducer through the host plate were measured. A point-focus pulsed laser-induced ultrasound was used to emulate an acoustic source in response to crack formation. Experimental results reveal that the PFC transducer can capture multimode fixed-wavelength Lamb waves, which can be discriminated by wavelet transform technique. Introduction Taking advantages of excellent actuating abilities and conformability, piezoelectric fiber composites (PFC) have been utilized as smart material actuators in applications of vibration suppression and structural health monitoring (SHM). The conventional PFC are made of either circular [1-3] or rectangular [4-6] cross sectional unidirectional piezoelectric fibers embedded in epoxy matrix and sandwiched between two flexible polymer sheets printed with symmetrically aligned interdigital electrodes (IDE). The electrode fingers are perpendicular to the piezoelectric fibers. A periodically inverted electric field is induced in the spaces between two adjacent electrode fingers during poling and actuation. The PFC can expand or contract simultaneously when a periodic voltage applies to the electrodes. However, the PFC can not be an effective acoustic wave transducer because of its symmetric configuration. Most PFC devices operate in frequency range lower than 1 khz. It can not satisfy the needs in application of SHM. The acoustic transducers in SHM applications are usually transmitting guided waves, for example, Lamb waves in plates. The structural guided waves exhibit multimodal dispersive behavior. Large sensitivity, high temporal and spatial discriminations are required for guided wave transducer in defect detection. It has resulted in a need for high frequency and directive transducers. The performance of PFC used as guided wave transducers can be improved by a new electrode layout [7]. The developing PFC transducer is poled symmetrically with respect to its mid-plane and thereafter activated by anti-symmetrically aligned interdigital electrodes. The devised PFC has periodic deformation when it is actuated by anti-symmetric electrodes and therefore, is abbreviated as AE-PFC. The transducers transmit Lamb waves at frequency up to 1 MHz. The operating frequency depends on the properties of AE-PFC and the host plate. In this work, characterization of the PFC transducers is conducted by directivity measurement and detection of broadband signal simulated by point-focus laser-induced ultrasound.

Piezoelectric Fiber Composite with Interdigital Electrodes A schematic of the PFC under poling process and actuation is illustrated in Fig. 1. Two sheets of polyimide films printed with IDE are placed on the top and bottom surfaces of unidirectional PZT-5A fibers (Advanced Cerametrics Inc., Lambertville, New Jersey) embedded in epoxy resin. The piezoelectric fibers have circular cross section with the average diameter.25 mm. The top and bottom surface electrode fingers are anti-symmetrically aligned with center-to-center one-quarter wavelength offset. Besides the IDE, two sets of zigzag electrodes might distribute on both top and bottom sheets to facilitate yielding intensive poling electric field. A piecewise inverted electric field is symmetrically generated. In contrast, an alternating voltage is applied on the IDE alone to yield an anti-symmetric electric field for excitation. The actuating electric field would be along or against the polarization alternately. A periodic deformation is therefore induced in the PFC transducer. When the PFC transducer surface adhered on a host plate, the resonant frequencies of PFC will be altered with amounts depending on the host plate. This effect has been discussed by the authors [7]. The fundamental extensional resonance of the PFC is used to emit Lamb modes in a 1 mm thick aluminum plate, in which the cut-off frequency of A 1 mode approximates to 1.6 MHz. Only two fundamental modes, named as A and S modes, can be actually excited within the frequency range from dc to 1.6 MHz. Fig. 2 shows the calculated displacement contours for A and S Lamb modes launched by a one wavelength long AE-PFC. The Lamb waves have the same frequency as the excitation. The transmitted Lamb mode near the area adhered to AE-PFC has a different wavelength other than the corresponding free Lamb wave since local stiffness of the host plate has been changed by AE-PFC. Experimental Characterization of AE-PFC The PFC transducer has been characterized by a series of experimental measurements. A PFC transducer was surface adhered to a 1 mm thick aluminum square plate of side length 1 m. The distance from the front edge of PFC to the plate periphery is two-third of the side length. The first experiment was conducted to measure the directivity of the PFC transducer. A conventional broadband 1 MHz ultrasonic transducer (ABT14-R, Staveley Sensors Inc.) was used to capture the waveforms transmitted from the PFC transducer. The ultrasonic transducer was placed normal to pate or inclined to the plate in combination with a 39 o wedge (Fig. 3). P P Fig. 1 Schematic diagrams of the presented piezoelectric fiber composite which is polarized by symmetric electric field, and actuated by anti-symmetric electric field about its mid-plane. The arrow with P indicates polarization direction. Fig. 2 Contours of the axial displacements for the A and S Lamb modes excited by AE-PFC adhered on the top surface of a 1 mm thick aluminum plate using a 1.3 MHz sinusoidal signal.

S A 1 S 1 Fig. 3 Experimental setup to measure the directivity of the PFC transducer in an aluminum plate. The PFC transducer was excited by 1 periods of low voltage 95 khz sinusoidal wave at 1 V P-P. Signal-to-noise ratio (SNR) can be increased by waveform averaging. Fig. 4 shows the waveforms measured by the broadband transducer which directly contacted with the plate and was located at distances of 2 and 3 mm from the PFC. The S waveform is relatively small in comparison with the A waveform. It was difficult to measure directivity of such a S mode. A 39 o wedge was then used to magnify amplitude of the S mode. The A mode was simultaneously reduced to almost the same intensity as S mode. The group velocities of the A and S Lamb modes were measured as 3.19 and 5.18 mm/μs. Compared with theoretical group velocities of Lamb waves propagating in an aluminum plate (Fig. 5), the measured results confirm both wave packets are A and S modes, respectively. 6 3 S A (c) (d) S A S A S A -6 4 6 8 1 12 Fig. 4 Waveforms measured at positions 2 mm and 3 mm in front of the presented PFC transducer by a conventional ultrasonic transducer; those measured by the same transducer through a 39 o wedge at distances of (c) 2 mm and (d) 3 mm. 6-3 4 6 8 1 12 Velocity (mm/ s) 4 2 A A 1 S 1 2 4 6 8 Frequency (MHz) Fig. 5 Phase velocities (solid lines) and group velocities (dashed lines) of Lamb waves propagating in 1 mm thick aluminum plate.

The experiment for measuring beam patterns of A and S Lamb modes were conducted using bursts launched by the PFC operated at 95 khz. The intensity of the waveform was measured every 5 o interval from o to 18 o along a circle of radius 2 mm with the center located at the middle of front edge of the PFC. The directivity of A mode is much stronger than S mode. In addition, the S mode has a skewed pattern inclined at an angle of 1 degrees. It is probably caused by the leakage of electric field lines at the edge of the electrode finger. Fig. 6 Radiation patterns of A and S Lamb modes emitted by a PFC transducer surface adhered on a 1 mm thick aluminum plate. Sudden crack formation in plates or shells made of brittle materials usually emits structural guided waves. A point-focus pulsed laser-induced ultrasound was used to emulate an acoustic source in response to crack formation. The acoustic source was located at 2 mm from the PFC transducer, which is a fixed-wavelength transducer. Fig. 7 depicts the multimode waveforms captured by the PFC transducer. Both S and A modes occurring in time domains, from 4 to 5 sec. and from 6 to 75 sec., exhibit a bit dispersive. The time-of-flights are the same as what are shown in Fig. 4, in which the S and A bursts traveling the same distance. Besides the fundamental modes, a 2.5 MHz signal and its echoes reflected from the edges of plate arrived twice in this time window. The multimode dispersive Lamb waves can be discriminated by wavelet transform or other time-frequency representation techniques. In practice, the high-frequency modes can be removed by low-pass filters and would not be confused with the fundamental modes. 8-8 4 6 8 1 12 Fig. 7 A 4 mj pulse laser induced transient waveform captured by AE-PFC at a distance of 2 mm. Frequency (MHz) 3. 2. 1. 4 6 8 1 12 Time (microsec) Fig. 8 Spectrogram corresponding to the multimode Lamb wave signal shown in Fig. 7.

Conclusions The presented low-voltage high-frequency PFC transducer is poled symmetrically and activated by anti-symmetrically aligned interdigital electrodes about its mid-plane. The radiation patterns of free A and S Lamb modes transmitted by the PFC transducer through the host plate were measured. The A mode has stronger directivity than the S mode. A leakage of electric field lines at the edge of front electrode fingers might yield skewed beam pattern of the S mode. But, A mode is free from such influence. A point-focus pulsed laser-induced ultrasound was used to emulate a broadband acoustic source in response to sudden crack formation. Experimental results reveal that the PFC transducer is a fixed-wavelength acoustic sensor which can capture multimode dispersive guided waves. Unexpected high frequency Lamb modes can be discriminated by time-frequency representation techniques. The high-frequency PFC transducer has a great potential in applications of guided wave structural health monitoring with the advantages of low voltage drive and fixed-wavelength sensing capability. Acknowledgment This work was supported by the National Science Council of the Republic of China through the grant NSC11-2221-E-9-21-MY2. References [1] A.A. Bent and N.W. Hagood, Piezoelectric fiber composites with interdigitated electrodes, J. Intel. Mat. Syst. Str. 6 (1997) 338-349. [2] A.J. Brunner, M. Barbezat, C. Huber, P.H. Flüeler, The potential of active fiber composites made from piezoelectric fibers for actuating and sensing applications in structural health monitoring, Mater. Struct., 38 (25) 561-567. [3] M. Barbezat, A.J. Brunner, C. Huber, P.H. Flüeler, Integrated active fiber composite elements: characterization for acoustic emission and acousto-ultrasonics, J. Intel. Mat. Syst. Str., 18 (27) 515-525. [4] W.K. Wilkie, R.G. Bryant, J.W. High, R.L. Fox, R.F. Hellbaum, A. Jalink, B.D. Little Jr., P.H. Mirick, Low-cost piezocomposite actuator for structural control applications, Proc. SPIE 3991, Smart Structures and Materials, (2) 323-334. [5] H. M. Matt, F.L. di Scalea, Macro-fiber composite piezoelectric rosettes for acoustic source location in complex structures, Smart Mater. Struct., 16 (27) 1489-1499. [6] Y. Pasco, P. Masson, Modelling of piezoelectric fiber composite material for ultrasonic wave generation, Proc. Internation Workshop Smart Materials and Structures, (29) 283-292. [7] C.-C. Yin, Y.-C. Wu, Y.-S. Liu, S.-M. Hsu, Flexible ultrasonic transducers using piezoelectric fiber composites with antisymmetric interdigital electrodes, IEEE International Ultrasonics Symposium Proc., (213).