STANDARD OPERATING PROCEDURE STAT-SITE M HGB

Similar documents
Energate Foundation Meter Data Collector Installation Guide

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Xyron Professional 2500 Laminating System

Adhesive Application & Laminating System

Photometer Maintenance Guide

Non-contact Forehead IR Thermometer

User instructions Compound laboratory microscope

Celerity Fiber Termination Kit

VIKING 2450 SERIES AUTO-DARKENING HELMETS 4.50 x 5.25 STANDARD REPLACEMENT LENS

Application Tooling Specification Sheet

Application Tooling Specification Sheet

English User's Guide

AH Auto-Darkening Welding Helmet User Manual. Made in China

5 Press the Up/Down arrow keys to select the desired tray, followed by the Confirm

Scratch Assay Device for Wound Healing Studies

Ambir ImageScan Pro 930u. User Guide. High Speed Document Scanner with UltraSonic Misfeed Detection. Ver 1.2. p/n UG930u-1.

INDEX OPERATING PRINCIPLE... 3 Power Supply... 4 Replacing the Batteries... 4 GENERAL PHOTOMETER OPERATION... 4 Operating Modes... 4 SYSTEM MODE...

From the home screen, navigate to:

SUSS Mask Aligner. Purpose: To expose photoresist on a wafer using a photomask

5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used

IDEXX-PACS * 4.0. Imaging Software. Quick Reference Guide

Table of Contents. Polytel GMA Glucose Meter Accessory Model PWR USER MANUAL Version: 2

Pro Advantage Urine Analyzer. Operator s Manual. Pro Advantage by NDC. All rights reserved PS-733 Rev 00-3/10 1/23

Harmony Remote Repair

ASX / OUTLANDER SPORT MZ538307EX SIDE MOULDING INSTALLATION AND HANDLING INSTRUCTIONS

Advanced User s Guide

С 800 CASSIDA C 800 HIGH SPEED COIN COUNTER

fi-6130 / fi-6230 Cleaning and Maintenance

1 Rolscreen Cartridge Removal:

S E L E C T I O N. Upper Back. User manual

Application Tooling Specification Sheet

Headset Intercom System. Operating Instructions

PowerCost Monitor. Installation Guide. Install the Batteries in the Display Unit. Install the Batteries in the Sensor Unit

RETINOPATHY SCREENING GUIDE

The Useless Machine. DIY Soldering Edition. Instruction Guide v0004

User s Manual. Magical Learn & Go. Disney Visit the Disney website at DisneyPrincess.com 2010 VTech Printed in China

Termination Procedure

User Manual.

WBGT Heat Index Meter TT-563

INSTRUCTION MANUAL Milwaukee Lab Photometer Mi490 Peroxide value

Wixey ELECTRONIC DIGITAL READOUT

UNIVERSAL TWO TIER. Change Table Model # IMPORTANT: RETAIN FOR FUTURE REFERENCE, READ CAREFULLY

Authorized Dealer Canada. BUY the 93M PAPER AND LETTER FOLDER - Click Here 93M. Paper Folder

Please read these instructions before use and keep for future reference

GETTING STARTED. Instructions IMPORTANT PS B PS B. Record the serial number from the tag on the door front.

01. Parts. Blink v1.1. Battery Holder x1. Red LED x1 Green LED x1 Blue LED x1. Resistors x3. Battery x1. Blink PCB x1. Push Button Switchers x3

BELGIAN EXT. REC DINING TABLE

RING CUTTING SYSTEM OPERATION MANUAL

Eye Examination Simulator. Instruction Manual

Any Questions? Contact us or Alligator Blinkie

Standard Operating Procedure

General Help. Last revised: Winter When I try to print something on the computer, it appears to work, but nothing comes out of the printer.

SHUFFLE KING 8. User manual. 1 to 8 deck shuffler.

Table of Contents. Polytel GMA Glucose Meter Accessory for LifeScan Meters Model PWR USER MANUAL Version: 1

Replace Musket Mainspring. Brown Bess 2 nd Model Short Land Pattern

imove-f Assembly Manual (Motorized Version-M1/M2)

3B SCIENTIFIC PHYSICS

Curium 19H Installation Instructions & Parts List

Junior Trampoline With Handle

F100 Tabletop Document Folder

User s Manual IM.indd 1 4/19/07 8:31:40 AM

Rechargeable Motivia Motorization Made Simple

User Manual User manual0708.indd /7/11 2:57:27 PM

Constable Oak Extension Dining Table

Zoom Stereo Microscope NYMCS-360 Instruction Manual

OPERATOR S MANUAL. World's Leader in Welding and Cutting Products. Sales and Service through Subsidiaries and Distributors Worldwide

Mercury 1200 and 1500P

English. User's Guide. Flextight 949. Downloaded from manuals search engine

User Manual 4 wire Earth Resistance Tester Model GRT300

Stuff-Your-Stuff Platform Bed (Twin and Full)

Learning to use your easypod. [somatropin (rdna origin) for injection]

VIKING TM 1840 Series

Read Before Use Accessories...2 Operating Precautions...2 Creating Data for the Roll Feeder... 3

EPSON Stylus Pro Quick Reference Guide

Cleaning the cutter blade

PRO 400 M401 MFP M425 CF-280A/X TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS

Standard Operating Procedure for Medtronic continuous glucose monitor

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

impact VC-500LR Monolight INSTRUCTIONS

A510S Operation Manual

Nuclear Associates

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

SC & FC/PC3 Pull-Proof Fiber Optic Connectors

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT

MD9300 Metal Detector OWNER S MANUAL

Thanks for shopping with Improvements! Providence Shoe/Boot Bench Item #457353

Instruction Manual M82

USER MANUAL. ReadyFire G6 and IR6 Laser Sight SM25008 SM25009

Q 3007 Biometric Transponder

Cut-True 16M Manual Paper Cutter

Table of Contents. Polytel GMA Glucose Meter Accessory for Bayer Ascensia Contour Model PWR USER MANUAL Version: B

Vortex. SrikeFire TM. Vortex Optics USA

User instructions Compound laboratory microscope

Scanner Parts. Scanner Specifications. General. Mechanical. Epson Perfection V200 Photo. P Power/ ] Start button Status light. { Copy button.

Contents. A January 2008 i

Digital Wireless Weather System

Table of Contents. Polytel GMA Glucose Meter Accessory for Abbott FreeStyle Lite and FreeStyle Freedom Lite Model PWR USER MANUAL Version: B

Nuclear Associates

USER MANUAL. ReadyFire G6 and IR6 Laser Sight SM25008 SM25009

Transcription:

Table of Contents 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 3 6. Precautions 9 7. References 9 8. Appendices 9 9. Revision History 9 Page Original Authorised Copy for: Reading Copy Written by: Reviewed by: Approved by: Signature/Date: Signature/Date: Signature/Date: Page 1 of 9

1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the STAT-Site M Hgb in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy Department, University of Malta. 2. Objective To describe the procedure for the set up, operation, maintenance and troubleshooting of the STAT-Site M Hgb. 3. Definitions 3.1. CODE Key: A chip that provides the device with important information about the test method and the lot number of the test cards. Each pack of test cards comes with a new CODE key that should be inserted into the device when a new pack of test cards is to be used. 3.2. Down Button: To select options. 3.3. On/Off Button: To switch the device on or off. 3.4. SET Button: Located under the test card platform and is used to set the desired unit of measurement i.e. mmol/l or g/dl. 3.5. STAT-Site M Hgb : A precision reflectance photometer used for the quantitative determination of haemoglobin in samples of whole blood. 3.6. Test Card Holder: The area into which the STAT-Site M Hbg Test Cards are inserted. 3.7. Test Card Platform: Removed to provide access to the battery, the CODE key and the SET button. 3.8. Up Button: To access memory and select options. Page 2 of 9

4. Responsibility 4.1. The members of the Department of Pharmacy (staff and students) are responsible for following this SOP. 4.2. The designated Laboratory Officer or Laboratory Assistant is responsible for ensuring that this SOP is followed. 5. Procedure 5.1. Diagram of STAT-Site M Hbg Display Screen On/Off Button UP Button Test Card Platform DOWN Button Test Card Platform Tab Test Card Holder 5.2. Set Up 5.2.1. Press the On/Off button to switch the device on. 5.2.2. Place thumb just under the test card platform tab. 5.2.3. Pull the entire test card platform up and away from the device. 5.2.4. Insert the appropriate CODE Key into the opening marked with an arrow. 5.2.5. Wait until [CODE], the coded test name (i.e. Hgb) and the code number is displayed to indicate that the CODE key has been correctly inserted. 5.2.6. Check that the displayed number corresponds to the number present on the test card container. 5.2.7. Press and hold the blue SET button until [g/dl] starts flashing. Page 3 of 9

5.2.8. Press the Up and Down buttons to scroll between the different units of measurements available i.e. mmol/l or g/dl. 5.2.9. Line up the top end of the test card platform with the corresponding edges of the device. 5.2.10. Press down on the test card platform until it snaps firmly into place. 5.3. Operation 5.3.1. Place the device on a level stable surface or hold it in such a way as to be roughly in a horizontal position. 5.3.2. Press the On/Off button to switch the device on. 5.3.3. Wait until a flashing test card symbol is displayed. 5.3.4. Slide the edges of the test card under the guide tabs of the test card holder. 5.3.5. Push the test card firmly to the back. 5.3.6. Check that the test card is locked firmly in place. 5.3.7. Wait until the test type (i.e. Hgb), a test card symbol and a flashing blood drop symbol are displayed to apply the blood sample. 5.3.8. Wipe the first drop of blood. 5.3.9. Apply the second free-flowing blood drop. 5.3.10. Position the drop of blood directly over the centre of the test card. 5.3.11. Carefully touch the drop of blood to the reagent pad in the central hole of the test card. 5.3.12. Wait until the test result countdown finishes. 5.3.13. Read the result from the display. 5.3.14. Press the On/Off button to switch the device on and the Up button to retrieve the last result if the device automatically switches off. The device switches off automatically after 2 minutes. 5.4. Maintenance 5.4.1. Check that the device is switched off before commencing with any maintenance procedures. 5.4.2. Replace the battery if a battery symbol is displayed on switching on the device. 5.4.2.1. Remove the test card platform. 5.4.2.2. Place a fingernail under the front edge of the battery and pull it upwards and away. 5.4.2.3. Insert a new 3V (CR 2032) lithium battery. 5.4.2.4. Check that the positive side of the battery is the visible side. Page 4 of 9

5.4.3. Wipe the exterior of the meter with a lint free cloth slightly moistened with 70% ethanol or 10% bleach solution. 5.4.4. Wipe the display screen and the optical area with a lint free cloth slightly moistened with water. 5.5. Troubleshooting Error Cause/s Solution/s [Lo] displayed Result is < 6g/dL Repeat test with a larger blood sample [Hi] displayed Result is > 21g/dL Repeat test and follow the steps on correctly applying blood samples more carefully [E-1] displayed Temperature Error Room temperature is outside the operating temperature of the device. Allow device to stabilise at adequate temperature and repeat test. [E-2] displayed Too much sample on test Repeat test with a new test card card - Test card not fully - Insert test card correctly [E-3] displayed inserted - Not enough sample - Repeat test with a new test card present [E-4] displayed Device Error Clean device and repeat test [E-5] displayed Card Error Clean device and repeat test. Do not apply sample to test card before this is inserted into device. [E-6] displayed Calibration Error Contact supplier [E-8] displayed CODE Key Error Contact supplier Page 5 of 9

5.6. Flow Charts 5.6.1. Set Up Start Press On/Off button to switch device on Place thumb just under the test card platform tab Pull entire test card platform up and away from device Insert appropriate CODE Key into the opening marked with an arrow Wait until [CODE], [Hgb] and code number are displayed to indicate that CODE key has been correctly inserted Check that displayed number corresponds with number present on test card container Press and hold blue SET button until [g/dl] starts flashing Press Up and Down buttons to scroll between the different units of measurements available (mmol/l or g/dl) Line up top end of test card platform with the corresponding edges of the device Press down on test card platform until it snaps into place End Page 6 of 9

5.6.2. Operation Start Place device on level stable surface or hold in such a way as to be roughly in a horizontal position Press On/Off button to switch device on Wait until flashing card symbol is displayed Slide edges of test card under guide tabs of test card holder Push test card firmly to the back Check that test card is locked firmly in place Wait until the [Hgb], a test card symbol and a flashing blood drop symbol are displayed to apply blood sample Wipe first drop of blood Apply second free-flowing blood drop Position drop of blood directly over centre of test card Carefully touch drop of blood to reagent pad in the central hole of test card Wait until test result countdown finishes Read result from display 1 Page 7 of 9

1 Yes Device automatically switched off No Press On/Off button to switch device on Press Up button to retrieve last result End 5.6.3. Maintenance Start Check that device is switched off before commencing with any maintenance procedures Yes Battery symbol displayed on switching on device Remove test card platform Place fingernail under front edge of battery and pull it upwards and away No No No Display screen Device exterior and/or optical area needs cleaning need/s cleaning Yes Wipe with a lint free cloth slightly moistened with 70% ethanol or 10% bleach Yes Wipe with a lint free cloth slightly moistened with water End Insert a new 3V (CR 2032) lithium battery Check that positive side of battery is the visible side Page 8 of 9

6. Precautions 6.1. Operate the device in an ambient temperature of +16 o C to +35 o C. 6.2. Do not store the device in damp and humid conditions. 6.3. Do not clean the device with isopropyl alcohol or products containing isopropyl alcohol. 6.4. Do not use a different CODE key from the one supplied with the test cards. 6.5. Do not touch or reposition the device while a test is being performed since this can compromise the precision and accuracy of the test. 6.6. Be careful not to scratch the test card platform window during cleaning. 6.7. Be careful not to scratch the window of the device when cleaning it whilst the test card platform is removed. 6.8. Stanbio STAT-Site M Hgb Haemoglobin External Controls can be used to check that the test cards and the device are working correctly. 7. References Stanbio Laboratory. STAT-Site M Hgb Haemoglobin Meter User s Guide. Texas: Stanbio Laboratory; 2004. 8. Appendices N/A 9. Revision History Version Number Amendments/ Reasons for change 01 Initial Release Page 9 of 9