R100 Controlled Door Closer

Similar documents
R100 Controlled Door Closer

The Third Generation Concealed Door Closer R102 IMPORTANT NOTICE - FOR FIRE DOOR INSTALLATIONS REFER TO ITEM 1 IN FITTING INSTRUCTIONS

Product data sheet R106FS POWERMATIC FREE SWING DOOR CLOSER

How To Measure Your Finished Opening

CERTIFICATE OF APPROVAL No CF 370 SAMUEL HEATH & SONS PLC

Arriva. Concealed frame doorsets. Installation instructions

Tools Required. * When installing on a fire door, please see instructions below. *

Fire rating: NFR/FD30. Una. Riser door systems. Installation instructions

ROOM FOLD SLIDING FOLDING INTERNAL DOORSET FITTING & FIXING GUIDELINES

HENDERSON. Securefold R-Loc Non-Mortice 100kg. Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

INSTALLATION INSTRUCTIONS

2 Section Slider Loft Ladder Instructions

HENDERSON. Securefold Bottom Rolling. Fitting Instructions For Bottom Rolling External Doors with Morticed hinges SYSTEM CAPACITY.

Door Hardware Installation Instructions. For Assistance Call:

INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installation Instructions

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Installation Instructions

INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

INSTALLATION INSTRUCTIONS

P USHbutton 500 series

LOWLINE SINGLE FOLD DOWN WALL BEDS

Innova. Concealed frame doorsets. Installation instructions

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

CL4500 Installation Instructions

CoFold Non-Mortice. Fitting Instructions for top hung exterior folding doors SYSTEM CAPACITY. Diagram 1. Diagram 2. Diagram 3.

Installing Your Electronic Deadbolt

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Replacement Guide. For Handle Side Z-bar on Fullview Doors with Laminated Glass and Multi-Point Locking System RECOMMENDED TOOLS:

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Installation Instructions II-2/4/5K-0608

Entry Mortise Handleset

INSTALLATION INSTRUCTION

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

POWER PET. Low-E Automatic Patio Pet Door Installation and Operating Instructions

2300 BI-FOLD INSTALLATION GUIDE

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

BARN DOOR HARDWARE KIT

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

O-Sullivan King 4 Poster Bed O-Sullivan Queen 4 Poster Bed Parts and Hardware List

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Installation Instructions. Oakmont Folding Doors

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Projector Ceiling Mount

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

MH60/MH72 DESK HUTCH IMPORTANT!

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

VISAGE SCREEN SYSTEM - FOUR SIDED (FLAT PACK) OPERATIONAL, ASSEMBLY & FIXING INSTRUCTION LEAFLET

DC3210. Recommended Closer Size

x2 1/4 (6mm) Floor Anchor

INSTALLATION MANUAL FORTRESS SERIES

Vanity Installation Instructions

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

INSTALLATION INSTRUCTIONS

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

Installation Instructions For The 8850FL Series Mortise eboss

Queen Wingback Bed King Wingback Bed

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

Vanity Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Flat Panel Arm Mount MLA100-L. VESA 100x100 compatible. Support 10" to 24" Screens Max Load Capacity: 30 lbs (15 kg)

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

MODUS 770 AND MODUS 1280 (FLAT PACK) OPERATIONAL, ASSEMBLY & FIXING INSTRUCTION LEAFLET

Installation Instruction

OSBORNE SHOWER DOOR INSTALLATION

ASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

GATE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CRL JACKSON

Installation Instructions. Installation Type

Laminate Cabinet Installation Instructions

TECHNICAL MANUAL - CONSTRUCTION AND INSTALLATION

Axminster Single Hinge Jig

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

Installation Instructions. Installation Type

installation instructions

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

VCL Aluminium Fitting Instructions

Transcription:

R100 Controlled Door Closer BODY HOLES FOR ALLEN KEY LINK ROD ADJUSTER WITH DUST CAP Samuel Heath closing speed power latching action LOCKING SCREW POWER LATCHING ACTION ADJUSTER LINK ROD patents applied for LISTED 85R6 HOLES FOR ALLEN KEY PLATE PLATE IMPORTANT NOTICE - FOR FIRE INSTALLATIONS REFER TO ITEM 1 IN FITTING INSTRUCTIONS CE marked and adjustable to conform to power size 3 of Controlled Door Closing Device. BS EN1154: 1997 (Test door 60kg/132lbs). 1 Hour Fire Test BS EN1634-1: 2000. Adjustable speed control. Adjustable power latching action. 1 1 /2 pairs of hinges should be used in conjunction with this closer on all doors. Suitable for doors opening to a maximum of 105º. A door stop should be fitted. Maximum door weight 80kg/175lbs, width 950mm/38. Suitable for latched and unlatched doors. Should NOT be used with rising butt hinges. For use with concealed hinges contact our Customer Service Team - details on the back of this leaflet PLEASE READ FITTING INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION.

power latching action speed patents applied for The Third Generation Concealed Door Closer PARTS LIST Fixing plates (A) Samuel Heath closing (B) (C) Door Closer - x 1 Template - x 1 Allen Keys - x 2 (D) (E) (F) (G) Screws - x 12 Extractor Bolt - x 1 Allen Key for Adjuster Screw (Locking) x 1 Mortice Template - x 1 CHECK ALL COMPONENT PARTS AGAINST PARTS LIST. TOOLS REQUIRED Screwdriver (Plain Slotted) Screwdriver (Phillips) Wood Chisel 25mm x 185mm/1 x 7 Solid Centre Auger Bit or Spade Bits 26mm Ø and 28mm Ø 1 1 / 16 Ø and 1 1 / 8 Ø Bradawl Power Drill Tape Measure Pencil Adjustable Spanner Ruler The use of a dedicated morticing tool is highly recommended for multiple installations. Mortice Template supplied. Order code R98.XX www.morticer.com A DBB morticer, a long shaft and WB27 and WB29 cutters will be required Eye Protectors, Ear Defenders and a Face Mask are recommended during installation of Perko-Powermatic.

1IMPORTANT NOTICE CLOSERS FITTED TO A FIRE. Perko Powermatic, conforms to Power Size 3 of Controlled Door Closing Device Standard BS EN1154:1997 when the power latching action is set to maximum. Turn adjuster screw fully to positive (+) as explained in 9. Closer must be fitted no more than 1000mm/39 from floor and within 300mm/12 of a hinge. Closer and plates should be bedded in either Alfacryl FR Intumescent Acrylic Mastic R99-XX or alternatively Intumescent Kit R97-XX, both available from Samuel Heath. Fig. 1 300mm / 12 MAX 2 TEMPLATE POSITIONING Ensure door is plumb, hinges are free, and that timber is sound. Take template provided and fold along center line. Open door to 90º. Secure template to door edge and frame edge within 300mm/12 of a hinge ensuring the center line is central in line with the pivot point of the hinge. Draw a vertical line at the centre point of the door edge on the template. NB This line must not exceed 35mm/1 3 /8 from template centre line. See Fig. 2 Repeat this vertical line onto the frame side at the same distance from centre line. At each point on the template where the vertical lines cross the horizontal dotted lines mark through the template using a bradawl into the door edge and frame edge to establish drilling points. Remove template RETAIN FOR REFERENCE. Note: Door can now be removed from frame to assist drilling if preferred.

To achieve a maximum opening angle of 105º the centre of the closer must be no more than 35mm/1 3 /8 from the pivot point of the hinge. Fig. 2 35mm 1 3 /8 MAX 35mm 1 3 /8 MAX IMPORTANT To ensure the 35mm/1 3 /8 distance is not exceeded the closer and fixing plate can both be offset in the door leaf and jamb (closer to the hinge pivot point) by up to a maximum of 6mm/ 1 /4 as illustrated below. 300mm / 12 MAX / /

3 PREPARATION FOR PLATE 4 PREPARATION FOR BODY & PLATE DRILL TO 5 30mm/1 /16 DEEP NB To ensure correct operation of closer there must be a 3mm/ 1 /8 gap between the two fixing plates when the door is in the closed position. These instructions are based on the gap between door and frame being 3mm - + 1.0mm. Drill 4 x 28mm/1 1 /8 Ø holes x 30mm/1 5 /16 deep to accept frame plate assembly as indicated on template. Drill 2 x 28mm/1 1 /8 Ø holes x 5mm deep to accept frame plate ends. * Remove excess timber between drilled holes to accommodate frame plate. Drill 4 x 26mm/1 1 /16 Ø x 185mm/7 5 /16 deep holes to accept closer body as indicated on the template. * Drill 2 x 28mm/1 1 /8 Ø holes x 5mm to accept door plate ends. * Remove excess timber between drilled holes to accept the closer body and door plate. * If using Intumescent kit R97-XX, refer to instructions with kit.

5 INSTALLING CLOSER 6 D SAMUEL HEAT ea SAMUEL HEATH + POWERMATIC C + POWERMATIC P ATENTS APPLIED FOR PATENTS APPLIED FOR E E D Insert closer body into door. Insert extractor bolt (E) into position and rotate clockwise until holes in link rods appear. Generally for thicker doors expose both holes on each rod. Insert the allen keys (C) through both top and bottom link rod holes. Both allen keys must be correctly located. Remove extractor bolt. Secure door plate to door with six screws (D). IMPORTANT With composite doors and door linings it is essential to drill pilot holes Ø 3 /32 (2.5mm) to suit fixing screws.

7 8 ADJUSTMENT - SAMU HEATH SAMUEL HEATH + POWER LATCHING ACTION - + + POWER LATCHING ACTION - + POWERMATIC POWERMATIC PATENTS APPLIED FOR PATENTS APPLIED FOR With the closer secure and now held open by allen keys, if necessary firmly push both link rods across door plate and offer frame plate into frame void. Secure with six screws (D). Open door slightly and remove allen keys. Installation is now complete. Remove dust cap. Use one of the allen keys (C) to adjust closing speed. Positive (+) increases door speed. Negative (-) reduces door speed, as indicated on door plate.

9 ADJUSTMENT - POWER LATCHING ACTION SAMUEL HEATH The Perkopower is protected by the following Patents and Applications. CANADA 2365822 2436363 HONG KONG 1038953 JAPAN 2000-602490 SINGAPORE 82862 TAIWAN 156554 USA 6625847 2004/0111831 UK AUSTRIA GB25447175 GB2415014 EP1605126 BELGIUM DENMARK POWERM ATIC F FRANCE GERMANY IRELAND ITALY EP1605126 LUXEMBOURG NETHERLANDS SPAIN The power latching action can be adjusted using a plain flat ended screwdriver. Loosen locking screw using allen key (F) to allow the adjuster screw to turn. Positive (+) increases the angle at which latching action engages. Negative (-) decreases angle at which the latching action engages. Re-tighten locking screw when correct power latching action achieved. SWEDEN SWITZERLAND LIECHTENSTEIN MAINTENANCE Ensure that fixing screws remain tightly fastened. Ensure that all components on the doorset, ie latch, hinges etc are functioning correctly. SAMUEL HEATH & SONS plc Leopold Street US Customer Service Birmingham 111 East 39th Street, Suite 2R B12 0UJ, England New York N.Y. 10016 Customer Service Team: +44 (0)121 766 4200 Telephone: (212) 599 5177 Fax: +44 (0)121 772 3334 Fax: (212) 818 9552 E-mail: info@samuel-heath.com E-mail: usa@samuel-heath.com www.samuel-heath.com / www.perko-powermatic.com 9-395 Nov 2014 10K