GROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition

Similar documents
MISTRAL SYSTEM IMPACT 2

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Busbar Trunking Assembly

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

SUPER COMPACT - SCP 6 SUPER COMPACT

BUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

GLS A GLS 15

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Totally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

SB 50 Connectors - up to 120 amps

Mobile distribution Canalis KXA (50 to 160 A) with mobile connections

Multi-conductor Lighting Busbar System A

Medium power busbar trunking

Cast resin transformers HARMONY TM

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Low-Voltage Power Distribution and Electrical Installation Technology

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps

Cable Management Solutions with DLP TM

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Powerpole Connectors - PP75: up to 120 Amps

SECTION CABLE TRAYS

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION PANELBOARDS

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

10. Mini Coax Connectors

Reduction - RD. Sample Order: 2000A / 1600A, Aluminium, Bolt-on, IP 55, 4 conductors KXA B - RD17. Right Side Feeder "T" Sample Order: B

Electrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installing with LI system

DESIGN CONSIDERATION OF ELECTRICAL DISTRIBUTION AND LIGHTNING PROTECTION SYSTEMS FOR HIGH-RISE BUILDING

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

7. INSPECTION AND TEST PROCEDURES

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

Safe and efficient power transmission in wind turbines

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Busbar and Modular Wiring Systems

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Safety switches with slotted hole lever

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

DLPlus. Dado and Skirting trunking LIMOGES Cedex. Phone : Fax :

Canalis KS. Contents. Presentation. Description. Catalogue numbers Dimensions. Installation

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Totally Integrated Power SIVACON 8PS busbar trunking systems siemens.com/busbar

SBS Connectors - up to 110 amps

Low-Voltage Power Distribution and Electrical Installation Technology

10. Mini Coax Connectors

INTERPLANT STANDARD - STEEL INDUSTRY

ET 40 - Electrician Theory Examination Marking Schedule

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

Characteristics 5 TeSys k contactors and reversing contactors

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Switching Power Supply Type SPP1 60W Enclosed type

SBS Connectors - up to 110 amps

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

SIVACON 8PS Busbar Trunking Systems

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

ThermoPLUS Smart Temperature Transmitter

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Proximity Sensor Terminology

PROXIMITY SENSOR TERMINOLOGY

Australian/New Zealand Standard

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

SERIESN50, COAXIAL CONNECTORS

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

TYPE APPROVAL CERTIFICATE

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Your passport to success TECHNICAL OVERVIEW

Transcription:

GROUP MEGABARRE IMPACT 800A 5000A Abu Dhabi Edition B U S B A R T R U K I G S Y S T E M

GEERAL DATA TRUKIG ELEMETS COECTIO ELEMETS TAP-OFF UITS ACCESSORIES SUSPESIO UITS TECHICAL DATA ISTALLATIO ISTRUCTIOS 2 8 23 37 44 47 51 55 Megabarre Group reserves the right to supply products that may differ in details from those shown in this publication, due to its policy of continuous development. - 1 -

GEERAL DATA The IMPACT busbar trunking system is designed for power transport and distribution and is especially suitable in the electrical switchroom both as a transformer-switchboard or switchboard-switchboard connection and as the main power distribution system for industrial, commercial and service industry. The IMPACT ABU DHABI EDITIO busbar trunking system is realized in the version with copper conductors and current ratings from 800A to 5000A granted with a maximum ambient temperature (daily average) of 50 C (55 C if you use insulation bars in F class/5 C). Thanks to a casing made with an aluminium alloy extruded profile which gives to the product great mechanical rigidity and resistance performances (with a very light weight), the product can be used in its standard configuration also in boundary ambient conditions. The standard product is offered in the 3P++Pe with the section equal to the phase section and with protection conductor (casing) with an equivalent section more than 0% of the phase cross-section.phase and neutral conductors are made by one or two bars depending on the rated current. In case of two bars version, the bars are opportunely connected in parallel at each junction. They are also available the 3P++Fe/2+Pe version with a dedicated earth conductor with a cross-section equal to 50% of the phase cross-section, the 3P++Fe+Pe version with a dedicated earth conductor with cross-section equal to 0% of the phase cross-section and the 3P+2+Pe version with the neutral conductor equal to 200% of the phase cross section. On request, copper conductors can be galvanically tin-or silver-plated along their entire length while the copper joint monoblock is always tin-plated and, on request, can be silver-plated. The IMPACT busbar trunking system is offered in the standard version painted RAL 7037. The IMPACT busbar trunking systems are made with sandwich technology (COMPACT); the conductor bars are compacted without any space inside the casing and are fully insulated using a no hygroscopic halogen free polyester sheath (thermal class 0 C), for uses in ambient till 50 C and 5 C, for uses in ambient till 55 C. This technology guarantees the products high performance in relation to voltage drop values even in high current and long runs. The standard protection degree is IP55 (on request IP66 only for transport lines without tap-off units). For outdoor installations an extra protection (canopy) is used. The electrical connection is achieved by a monoblock system with one or more bolts (depending of the busbar trunking rated current) with an anti-screwing spring which guarantees the electrical continuity between the units of the run. The self-breakable bolt is double headed; the first head is used for the installation (breaking at 85 m torque moment) carried out without any special tool, while the second head will be available for future maintenances and inspections. A visual signal (red tag) confirms the correct tension on the monoblock. The mechanical connection is achieved when the joint cover unit is completely installed, thus guaranteeing that the IP55 protection degree is achieved (on request IP66). A mechanical interlock device prevents the installer from completing the mechanical connection until the electrical connection is correctly completed. The joint monoblock doesn t need any maintenance. WHY CHOOSE IMPACT? ADVATAGES - ominal rating guaranteed both for flat and edgewise installations (no derating) - ominal rating is related to an ambient temperature up to 50-55 C - Protection degree guaranteed both for flat and edgewise installations - Painted aluminium extruded alloy casing with high mechanical strength characteristics - Maintenance free monoblock joint with tin plated copper contacts - Smaller - Lighter - Customized on request - An engineering department at your disposal for site measurements, trunking run evaluations and electrical equipment connection study (switchboard, transformer etc...). A GREE PRODUCT The IMPACT trunking units are 0% reusable in case it is necessary to change its layout. 98% of the product material is recyclable and the distinctive production process is able to reduce manufacturing time and also minimise energy consumption according to common standards for minor environmental impact. COFORMS WITH: CEI-E 61439-1/6 IEC 61439-1/6 CEI-E 60529 IEC 529 E 1366-3 IEC 60331 IEC 60332-2 -

GEERAL DATA HOW CALCULATE THE CURRET RATIG OF BUSBAR TRUKIG SYSTEM The calculation of the operational current (I b ) for a three-phase system of an IMPACT busbar trunking IMPACT can be made using the following formula: I b = P x F 3 x Ue x cosϕ...and it has to consider the following parameters. P F total power of the feed load (W) feeding load contemporary factor According to the feeding load quantity and to the placement (industrial, residential, service etc...)there is a coefficient that indicates the contemporary charge factor, even if, it is necessary to evaluate each case. Following please find some suggestions related to the number of loads and to the placement type: total power x80=1200 kw 1200000 W (P) Contemporary factor 0.8 (F)...approximately we suggest to calculate at least 20% of margin between the rating required and the nominal rating of the conductor according to possible expanding. 1460A + 20% = 1752A The IMPACT busbar trunking that can be used as... 2000A Cu I b = 1200000 x 0,8 = 1460A 1,73 x 400 x 0,95...it is necessary to control the ambient temperature of the busbar placement. The IMPACT conductors are dimensioned according to the max ambient temperature (daily average) of 50 C or 55 C with class F insulation. According to the real ambient conditions, the conductor must be downgraded following this schedule. K PLACEMET UMBER OF USERS COTEMPORARY FACTOR (F) IDUSTRIAL from 1 to 0,8-0,9 IDUSTRIAL from to 20 0,7-0,8 IDUSTRIAL from 20 to 40 0,6-0,7 IDUSTRIAL MORE THA 40 0,5-0,4 SERVICE BIG OFFICES 0,7-0,8 SERVICE SHOPPIG CETERS 0,8-0,9 Ue operating voltage(v) Example: Placement Service/shopping center User Single user power 80 kw Voltage 400V Cosϕ 0,95 I b = P x F 3 x Ue x cosϕ downgraded factor according to the ambient temperature ( C) Ambient temperature * ( C) 50 55* 60 65 70 Downgraded K factor 1 1 0,84 0,75 0,6 Example. Ambient temperature (daily average) 60 C The IMPACT conductor 4000A has to be downgraded according to the K factor that is equal to 0,84. 2000 x 0,84 = 1680A.if the ambient temperature is 60 C, the 2000A conductor can be used with a maximum current not higher than 1680A. If the value doesn t guarantee the maximum current required, it is necessary to choose a conductor with a higher rating. * With class F insulation material - 3 - The selection of IMPACT conductor according to the voltage drop. The selection of IMPACT busbar system must be made according to the maximum limit of voltage drop required by the specific reference. The voltage drop calculation (ΔV percentage ) for a three-phase system of an IM- PACT busbar trunking system must be calculated following this formula: ΔV% = D x t x I x L b x 0 Ue and must consider these parameters D Load distribution factor according to the feeding point and the location of the loads to feed, there is a multiplier coefficient. This multiplier allows a quick calculation that must be considered approximate. t D=1 Feeding on one side and load at the end of the line. Feeder line D=0,5 Feeding on one side and loads equally distributed along the length. Distribution line Unitary voltage drop value according to a cosϕ data, the following schedule contains the unitary voltage drop values for (μv) 1 ampere for 1 meter of the IMPACT busbar trunking system. (calculated with 50 C ambient temperature) 800A 00A 1250A 1600A 2000A 2500A 3200A 4000A 5000A cosϕ=0,70 8,49 8,49 74,36 65,83 60,97 42,78 45,20 36,65 25,60 cosϕ=0,75 111,03 111,03 76,08 67,31 62,27 42,96 45,56 36,93 26,18 cosϕ=0,80 113,14 113,14 77,50 68,51 63,32 42,90 45,67 37,02 26,64 cosϕ=0,85 114,66 114,66 78,52 69,34 64,02 42,52 45,46 36,85 26,97 cosϕ=0,90 1,29 1,29 78,92 69,63 64,20 41,65 44,76 36,27 27,08 cosϕ=0,95 114,28 114,28 78,19 68,89 63,42 39,87 43,16 34,96 26,79 cosϕ=1 3,80 3,80 70,93 62,28 57,09 32,87 36,33 29,41 24,22 I b Addition of all the effective loads of the trunking busbar (A) L Total length in meters of the busbar trunking (m) U e Feeding nominal voltage (V) Example: IMPACT 2000A Cu busbar trunking verification with a distributed load (L) line length 80m (I b ) effective load 1752A (U e ) feeding voltage 400V Cosϕ 0,95 (D) load distribution factor 0,5 (T) Unitary voltage drop value for 2000A Cu 63,42 (V) -6 (ΔV) maximum voltage drop admitted 2,5% ΔV% = D x t x I x L b Ue x 0 ΔV% = 0,5 x 63,42 x -6 x 1752 x 80 x 0 400 ΔV% = 0,5 x 63,42 x 1752 x 80 x 0 = 1,1% 400 x 6 The value is less than the max limit admitted (2,5%), so the verification is positive

GEERAL DATA IMPACT SERIES - READY FOR EVERYTHIG (CERTIFICATES) The IMPACT busbar trunking system is used for power transport and distribution and is especially suitable both in electrical cabins as a transformer-switchboard or switchboard-switchboard connection and in the main power distribution for industrial, commercial and service industry. The increasing evolution of the technology system over the modern market has made these products more and more efficient and able to satisfy the installation requirements and guarantee application reliability. The demand for busbar trunking systems installation increases in public places such as hospitals, theaters, banks, schools etc... or in skyscrapers or on ships and in wind energy towers. With IMPACT series, Megabarre wants to offer a product ready for everything investing in productive technology process, product material, product assistance and certification. Please find below a complete list of certification for each rating in accordance with IEC 60439-1/IEC 60439-6:.2 Strength of materials and parts: Resistance to corrosion.2.3.2 Resistance to abnormal heat and fire due to internal electric effects.2.6 Mechanical impact.2.7 Marking.2.1 Ability to withstand mechanical loads.2.2 Thermal cycling test.3 Degree of protection of assembly.4 Clearances and creepage distances.5 Protection against electric shock and integrity of protective circuits.9 Dielectric properties..2.3.5 Verification of temperature rise limits of a BT run..2.3.6 Verification of temperature rise limits of a tap-off unit.11 Short-circuit withstand strength.13 Mechanical operation.1 Resistance to flame propagation.2 Fire resistance in building penetration Test to verify the no propagation of flame according to the IEC 60332 norm. This tests certifies that, when the IMPACT bus-bar trunking system is subjected to a direct flame, the flame itself does not propagate to a longer distance than 2,5 m. Verification of compliance with E 1366-3 in relation to when a busbar passes through a wall or floor that the limitation of smoke transmission, flame and temperature for a given time period is guaranteed. Test time: 180 minutes Certification: EI 180 Test to verify the flame-resistance with mechanical shock according to the IEC 60331norm. This test certifies that, when the IMPACT bus-bar trunking system is subjected to both a direct flame and a provoked impact, it insures the continuity of the energy distribution for a given period of time. Test time: 45 minutes - 120 minutes - 180 minutes Certified time: 45 minutes (standard trunking system); 120 minutes (specially insulated trunking system); 180 minutes (specially insulated trunking system). The mapping of the electromagnetic field level according to the CEI 211-6 / 2001 norm. The test verifies the emission of the electromagnetic field at variable distances from the trunking at a specified nominal rating. Vibrations test according to the IEC 60068 norm. This test certifies that the IMPACT busbar trunking system subjected to vibrations of 0,7 g and to 2 g along the three axis confirms its compliance with both the dielectric tests and the mechanical functioning tests. Test value: 0,7 g / 2 g (acceleration). - 4 -

GEERAL DATA SERIES COFIGURATIO The Impact busbar trunking system is available in four distinctive configurations in which the neutral conductor s crosssection and the protection cross- section change according to needs. The available versions are illustrated below with the compilation code. clean extra Pe 0% 200% earth earth involucro FE 0% FE 50% casing AAA BAA GAA DAA To order these configurations, please substitute the code s final three letters in bold (AAA) with the ones of the configuration you want to require. es. IMA04A01AAA IMA04A01- - - + BAA = IMA04A01BAA (AAA) FE (BAA) 3P + + PE (4P) 3P + + FE + PE (5P) eutral cross- section equal to 0% of the phase cross- section. Equivalent casing cross-section (PE) greater than 0% of the phase cross-section. eutral cross-section equal to 0% of the phase cross-section. Insulated protection cross-section(fe) equal to 0% of the phase cross-section. Equivalent casing cross-section (PE) greater than 0% of the phase cross-section. 132 4 Technical data see pg. 88-89 Technical data see pg. 90-91 Fe/2 (GAA) (DAA) 3P + + FE/2 + PE (5P) 3P + 2 + PE (5P) eutral cross- section equal to 0% of the phase cross-section. Protection cross-section (FE) (connected to the casing) equal to 50% of the phase cross-section. Equivalent casing cross-section (PE) greater than 0% of the phase cross-section. eutral cross- section equal to 200% of the phase cross-section. Equivalent casing cross-section (PE) greater than 0% of the phase cross-section. 4 4 Technical data see pg. 92-93 Technical data see pg. 94-95 - 5 -

GEERAL DATA EUTRAL POSITIO The active conductors /// of the IMPACT busbar system, even though they have equal cross-sections (except the DAA version whose neutral is equal to 200% of the phase cross-section), they are fixed in the trunking units (straight elements, elbows etc...) with an unique position and identification. As a result, the neutral is always set according to the phases sequence ///, on the same side of the conductor where the joint monoblock bolt head is. This position is bent and maintained by the joint system between the two units (see page 98) that guarantees the order of the phase sequence from the beginning until the end of the line with a mechanical connection. I THE IMPACT SERIES, THE EUTRAL COICIDES WITH THE BOLT SIDE I THE JOIT MOOBLOCK. PHASE SEQUECE/e/Fe 4P 5P Fe() 4P 5P Fe() - 6 -

GEERAL DATA RISIG MAI ELEMETS The continuous electrical systems evolution has transformed the traditional view of busbar trunking systems. At the beginning, it was used for high power transport but now also for electric energy distribution. One of the applications is in offices and residential buildings rising mains (skyscrapers) for energy distribution on various floors. The Impact line provides a large range of components and accessories to satisfy high-rise buildings applications. Our technical department is at your disposal to give technical support for correct application of components and/or accessories. End cover unit (see pag. 74) Distribution straight trunking unit with tap-off facilities on one side (see pag. 22) in order to have tap-off units with cable exit on the bottom, it is necessary to install the element with the eutral on the left (monoblock bolt on the left side of the conductor) Bolt side Fire barrier (see pag. 76) Monoblock Joint cover (see pag. 75) Tap-off (see pag. 63) For elements with tap-off facilities only on one side, it is necessary to install the element with the joint monoblock towards the top. Fixing and suspension bracket for vertical elements (see pag. 84) Fixing and suspension bracket for vertical elements (see pag. 82) Feeder unit (see pag. 52) Tap-off outlet - 7 -

TRUKIG ELEMETS STRAIGHT TRUKIG ELEMET - FEEDER Technical data see pg. 51 A transport straight trunking element is used for electric power transport. It is available in 3000 mm standard length or special on request (starting from 600mm) and supplied with the monoblock already installed. Installing the tap-off unit on the junction with the system not energized, it can also be used as a distribution unit. L=3000 IAC08A01AAA IACA01AAA IAC13A01AAA IAC16A01AAA IAC20A01AAA IAC25A01AAA IMC32A01AAA IMC41A01AAA IMC51A01AAA L=600 2999 IAC08A11AAA IACA11AAA IAC13A11AAA IAC16A11AAA IAC20A11AAA IAC25A11AAA IMC32A11AAA IMC41A11AAA IMC51A11AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Single bar Double bar 800A 2000A Cu 2500A 5000A Cu (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Y H 3000 (*) (*) min 600 mm (Y) 4P 5P AAA BAA GAA DAA 132 4-8 -

TRUKIG ELEMETS DISTRIBUTIO STRAIGHT TRUKIG ELEMET/TAP-OFF UITS O BOTH SIDES Technical data see pg. 51 The straight trunking element for distribution is used for electrical energy distribution by using tap-off units even when the system is energized. The standard version has 6 tap-off facilities (3 on each side) for the 4 poles version (AAA) and 4 tap-off facilities (2 on each side) for the 5 poles version (BAA,GAA,DAA), along a 3000mm standard length. The non standard length elements with a number of special tap-off facilities (max up to 4 per side) are realisable after evaluation of our technical department. Each tap-off facility has an automatic device to restore the IP protection degree when the tap-off facility is disconnected. L = 3000 3+3 Tap Std. IAC08A23AAA IACA23AAA IAC13A23AAA IAC16A23AAA IAC20A23AAA IAC25A23AAA IMC32A23AAA IMC41A23AAA IMC51A23AAA 2+2 Tap Std. IAC08A30BAA IACA30BAA IAC13A30BAA IAC16A30BAA IAC20A30BAA IAC25A30BAA IMC32A30BAA IMC41A30BAA IMC51A30BAA 2+2 Tap Std. IAC08A30GAA IACA30GAA IAC13A30GAA IAC16A30GAA IAC20A30GAA IAC25A30GAA IMC32A30GAA IMC41A30GAA IMC51A30GAA 2+2 Tap Std. IAC08A30DAA IACA30DAA IAC13A30DAA IAC16A30DAA IAC20A30DAA IAC25A30DAA IMC32A30DAA IMC41A30DAA IMC51A30DAA L = 2001 3000 3+3 Tap Sp. * IAC08A22AAA IACA22AAA IAC13A22AAA IAC16A22AAA IAC20A22AAA IAC25A22AAA IMC32A22AAA IMC41A22AAA IMC51A22AAA 2+2 Tap * IAC08A24AAA IACA24AAA IAC13A24AAA IAC16A24AAA IAC20A24AAA IAC25A24AAA IMC32A24AAA IMC41A24AAA IMC51A24AAA 1+1 Tap * IAC08A25AAA IACA25AAA IAC13A25AAA IAC16A25AAA IAC20A25AAA IAC25A25AAA IMC32A25AAA IMC41A25AAA IMC51A25AAA L = 01 2000 2+2 Tap * IAC08A26AAA IACA26AAA IAC13A26AAA IAC16A26AAA IAC20A26AAA IAC25A26AAA IMC32A26AAA IMC41A26AAA IMC51A26AAA 1+1 Tap * IAC08A27AAA IACA27AAA IAC13A27AAA IAC16A27AAA IAC20A27AAA IAC25A27AAA IMC32A27AAA IMC41A27AAA IMC51A27AAA L = 00 1+1 Tap * IAC08A28AAA IACA28AAA IAC13A28AAA IAC16A28AAA IAC20A28AAA IAC25A28AAA IMC32A28AAA IMC41A28AAA IMC51A28AAA SPECIAL 4+4 Tap * IAC08A29AAA IACA29AAA IAC13A29AAA IAC16A29AAA IAC20A29AAA IAC25A29AAA IMC32A29AAA IMC41A29AAA IMC51A29AAA (AAA) AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE (BAA) (GAA) (DAA) cable exit (*) For elements with special number or special outlet spacings, please contact our technical department. cable exit Y H (AAA) 3 tap-off units on each side 3000 750 750 750 750 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (BAA) (GAA) (DAA) 2 tap-off units on each side Y H 3000 750 00 750 (Y) 4P 5P AAA BAA GAA DAA 132 4-9 -

TRUKIG ELEMETS Technical data see pg. 51 DISTRIBUTIO STRAIGHT TRUKIG ELEMET WITH TAP-OFF UITS OLY O OE SIDE The distribution straight trunking element is used for electrical energy distribution using tap-off facilities that can be installed even when the system is energized. The standard version has 3 tap-off facilities on only one side for the 4 poles version (AAA) and 2 facilities on only one side for the 5 poles version (BAA,GAA,DAA), along a 3000mm standard length. The non standard length elements with a number of special tap-off facilities (max up to 4 on one side) are realisable after evaluation of our technical department. Each tap-off facility has an automatic device to restore the IP protection degree when the tap-off facility is disconnected. L = 3000 3 Tap Standard IAC08A33AAA IACA33AAA IAC13A33AAA IAC16A33AAA IAC20A33AAA IAC25A33AAA IMC32A33AAA IMC41A33AAA IMC51A33AAA 2 Tap Standard IAC08A40BAA IACA40BAA IAC13A40BAA IAC16A40BAA IAC20A40BAA IAC25A40BAA IMC32A40BAA IMC41A40BAA IMC51A40BAA 2 Tap Standard IAC08A40GAA IACA40GAA IAC13A40GAA IAC16A40GAA IAC20A40GAA IAC25A40GAA IMC32A40GAA IMC41A40GAA IMC51A40GAA 2 Tap Standard IAC08A40DAA IACA40DAA IAC13A40DAA IAC16A40DAA IAC20A40DAA IAC25A40DAA IMC32A40DAA IMC41A40DAA IMC51A40DAA L = 2001 3000 3 Tap Special * IAC08A32AAA IACA32AAA IAC13A32AAA IAC16A32AAA IAC20A32AAA IAC25A32AAA IMC32A32AAA IMC41A32AAA IMC51A32AAA 2 Tap * IAC08A34AAA IACA34AAA IAC13A34AAA IAC16A34AAA IAC20A34AAA IAC25A34AAA IMC32A34AAA IMC41A34AAA IMC51A34AAA 1 Tap * IAC08A35AAA IACA35AAA IAC13A35AAA IAC16A35AAA IAC20A35AAA IAC25A35AAA IMC32A35AAA IMC41A35AAA IMC51A35AAA L = 01 2000 2 Tap * IAC08A36AAA IACA36AAA IAC13A26AAA IAC16A36AAA IAC20A36AAA IAC25A36AAA IMC32A36AAA IMC41A36AAA IMC51A36AAA 1 Tap * IAC08A37AAA IACA37AAA IAC13A27AAA IAC16A37AAA IAC20A37AAA IAC25A37AAA IMC32A37AAA IMC41A37AAA IMC51A37AAA L = 00 1 Tap * IAC08A38AAA IACA38AAA IAC13A28AAA IAC16A38AAA IAC20A38AAA IAC25A38AAA IMC32A38AAA IMC41A38AAA IMC51A38AAA SPECIAL 4 Tap * IAC08A39AAA IACA39AAA IAC13A39AAA IAC16A39AAA IAC20A39AAA IAC25A39AAA IMC32A39AAA IMC41A39AAA IMC51A39AAA (AAA) (BAA) (GAA) (DAA) AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE (*) For elements with special number or special outlet spacings, please contact our technical department. cable exit Y H (AAA) 3 tap- off units on one side 3000 750 750 750 750 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Y H (BAA) (GAA) (DAA) 2 tap-off units on one side 3000 750 00 750 (Y) 4P 5P AAA BAA GAA DAA 132 4 - -

TRUKIG ELEMETS FLAT ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard and special lengths are available according to the installations requirements. Standard RH IAC08B01AAA IACB01AAA IAC13B01AAA IAC16B01AAA IAC20B01AAA IAC25B01AAA IMC32B01AAA IMC41B01AAA IMC51B01AAA LH IAC08B02AAA IACB02AAA IAC13B02AAA IAC16B02AAA IAC20B02AAA IAC25B02AAA IMC32B02AAA IMC41B02AAA IMC51B02AAA Special RH IAC08B11AAA IACB11AAA IAC13B11AAA IAC16B11AAA IAC20B11AAA IAC25B11AAA IMC32B11AAA IMC41B11AAA IMC51B11AAA LH IAC08B12AAA IACB12AAA IAC13B12AAA IAC16B12AAA IAC20B12AAA IAC25B12AAA IMC32B12AAA IMC41B12AAA IMC51B12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH H (B) + (H/2) (B) (A) (B) 800A 2000A Cu std 300 300 min 300 300 max 899 899 2500A 5000A Cu std 450 450 min 450 450 max 49 49 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Y (A) + (H/2) (A) (Y) 4P 5P AAA BAA GAA DAA 132 4-11 -

TRUKIG ELEMETS DIHEDRAL ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard and special length are available according to the installations requirements. Standard RH IAC08C01AAA IACC01AAA IAC13C01AAA IAC16C01AAA IAC20C01AAA IAC25C01AAA IMC32C01AAA IMC41C01AAA IMC51C01AAA LH IAC08C02AAA IACC02AAA IAC13C02AAA IAC16C02AAA IAC20C02AAA IAC25C02AAA IMC32C02AAA IMC41C02AAA IMC51C02AAA Special RH IAC08C11AAA IACC11AAA IAC13C11AAA IAC16C11AAA IAC20C11AAA IAC25C11AAA IMC32C11AAA IMC41C11AAA IMC51C11AAA LH IAC08C12AAA IACC12AAA IAC13C12AAA IAC16C12AAA IAC20C12AAA IAC25C12AAA IMC32C12AAA IMC41C12AAA IMC51C12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH (A) + (Y/2) (A) 300 Y (A) (B) 800A 5000A Cu std 300 300 min 250 250 max 849 849 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H (B) 300 B + (Y/2) (Y) 4P 5P AAA BAA GAA DAA 132 4-12 -

TRUKIG ELEMETS DOUBLE FLAT ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard and special length are available according to the installations requirements. RH IAC08D11AAA IACD11AAA IAC13D11AAA IAC16D11AAA IAC20D11AAA IAC25D11AAA IMC32D11AAA IMC41D11AAA IMC51D11AAA LH IAC08D12AAA IACD12AAA IAC13D12AAA IAC16D12AAA IAC20D12AAA IAC25D12AAA IMC32D12AAA IMC41D12AAA IMC51D12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH H (C) (A) (B) 800A 2000A Cu std 300 300 min 300 300 max 899 899 2500A 5000A Cu std 450 450 min 450 450 max 49 49 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (B) (B) + (H) Y (A) (A) + (C) (Y) 4P 5P AAA BAA GAA DAA 132 4-13 -

TRUKIG ELEMETS DOUBLE DIHEDRAL ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard and special length are available according to the installations requirements. RH IAC08E11AAA IACE11AAA IAC13E11AAA IAC16E11AAA IAC20E11AAA IAC25E11AAA IMC32E11AAA IMC41E11AAA IMC51E11AAA LH IAC08E12AAA IACE12AAA IAC13E12AAA IAC16E12AAA IAC20E12AAA IAC25E12AAA IMC32E12AAA IMC41E12AAA IMC51E12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH (B) + Y Y (A) + (Y/2) (A) 300 (B) 300 (A) (B) 800A 5000A Cu std 300 300 min 250 250 max 849 849 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H (A) + (C) (C) 300 (Y) 4P 5P AAA BAA GAA DAA 132 4-14 -

TRUKIG ELEMETS FLAT + DIHEDRAL ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard than special length are available according to the installations requirements. Type 1 IAC08F11AAA IACF11AAA IAC13F11AAA IAC16F11AAA IAC20F11AAA IAC25F11AAA IMC32F11AAA IMC41F11AAA IMC51F11AAA Type 2 IAC08F12AAA IACF12AAA IAC13F12AAA IAC16F12AAA IAC20F12AAA IAC25F12AAA IMC32F12AAA IMC41F12AAA IMC51F12AAA Type 3 IAC08F13AAA IACF13AAA IAC13F13AAA IAC16F13AAA IAC20F13AAA IAC25F13AAA IMC32F13AAA IMC41F13AAA IMC51F13AAA Type 4 IAC08F14AAA IACF14AAA IAC13F14AAA IAC16F14AAA IAC20F14AAA IAC25F14AAA IMC32F14AAA IMC41F14AAA IMC51F14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 (B) + (Y/2) (B) 300 Y H (C) + (H/2) (C) (A) (B) (C) mm 800A 2000A Cu std 300 300 300 min 250 2 300 max 849 549 899 2500A 5000A Cu std 300 300 450 min 250 320 450 max 849 699 49 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (A) 300 (A) + (Y/2) (Y) 4P 5P AAA BAA GAA DAA 132 4 - -

TRUKIG ELEMETS DIHEDRAL + FLAT ELBOW Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Both standard and special length are available according to the installations requirements. Type 1 IAC08G11AAA IACG11AAA IAC13G11AAA IAC16G11AAA IAC20G11AAA IAC25G11AAA IMC32G11AAA IMC41G11AAA IMC51G11AAA Type 2 IAC08G12AAA IACG12AAA IAC13G12AAA IAC16G12AAA IAC20G12AAA IAC25G12AAA IMC32G12AAA IMC41G12AAA IMC51G12AAA Type 3 IAC08G13AAA IACG13AAA IAC13G13AAA IAC16G13AAA IAC20G13AAA IAC25G13AAA IMC32G13AAA IMC41G13AAA IMC51G13AAA Type 4 IAC08G14AAA IACG14AAA IAC13G14AAA IAC16G14AAA IAC20G14AAA IAC25G14AAA IMC32G14AAA IMC41G14AAA IMC51G14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 (C) + (H/2) (C) (B) + (H/2) (B) 300 (A) (B) (C) mm 800A 2000A Cu std 300 300 300 min 250 2 300 max 849 549 899 2500A 5000A Cu std 300 300 450 min 250 320 450 max 849 699 49 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H (A) 300 (A) + (Y/2) Y (Y) 4P 5P AAA BAA GAA DAA 132 4-16 -

TRUKIG ELEMETS FLAT TEE Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Type 1 IAC08H11AAA IACH11AAA IAC13H11AAA IAC16H11AAA IAC20H11AAA IAC25H11AAA IMC32H11AAA IMC41H11AAA IMC51H11AAA Type 2 IAC08H12AAA IACH12AAA IAC13H12AAA IAC16H12AAA IAC20H12AAA IAC25H12AAA IMC32H12AAA IMC41H12AAA IMC51H12AAA Type 3 IAC08H13AAA IACH13AAA IAC13H13AAA IAC16H13AAA IAC20H13AAA IAC25H13AAA IMC32H13AAA IMC41H13AAA IMC51H13AAA Type 4 IAC08H14AAA IACH14AAA IAC13H14AAA IAC16H14AAA IAC20H14AAA IAC25H14AAA IMC32H14AAA IMC41H14AAA IMC51H14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 H (B) (B) + (C) (C) (A) (B) (C) mm 800A 2000A Cu std 300 300 300 2500A 5000A Cu std 600 600 600 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Y (A) + (H/2) (A) (Y) 4P 5P AAA BAA GAA DAA 132 4-17 -

TRUKIG ELEMETS DIHEDRAL TEE Technical data see pg. 51 This element enables the busbar trunking system to achieve all possible layouts. Type 1 IAC08I11AAA IACI11AAA IAC13I11AAA IAC16I11AAA IAC20I11AAA IAC25I11AAA IMC32I11AAA IMC41I11AAA IMC51I11AAA Type 2 IAC08I12AAA IACI12AAA IAC13I12AAA IAC16I12AAA IAC20I12AAA IAC25I12AAA IMC32I12AAA IMC41I12AAA IMC51I12AAA Type 3 IAC08I13AAA IACI13AAA IAC13I13AAA IAC16I13AAA IAC20I13AAA IAC25I13AAA IMC32I13AAA IMC41I13AAA IMC51I13AAA Type 4 IAC08I14AAA IACI14AAA IAC13I14AAA IAC16I14AAA IAC20I14AAA IAC25I14AAA IMC32I14AAA IMC41I14AAA IMC51I14AAA Type 1 AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 2 Type 3 Type 4 30 H 30 (A) + (Y/2) (A) 185 185 Cast resin insulation 185 4P AAA (A) (B) (C) mm 800A 2000A Cu std 500 500 500 2500A 5000A Cu std 550 550 550 5P BAA - GAA - DAA (A) (B) (C) mm 800A 2000A Cu std 550 550 550 2500A 5000A Cu std 600 600 600 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Y (B) (B) + (C) (C) 30 Y 30 (Y) 4P 5P AAA BAA GAA DAA 132 4-18 -

TRUKIG ELEMETS STRAIGHT ELEMET WITH PHASE TRASPOSITIO Technical data see pg. 51 The straight trunking element with phase transposition is used when the phase/neutral sequence at the beginning of a line does not match with the end of it. In this case, the use of this 00 mm unit allows the transposition of the phases, the neutral and the earthing conductor according to the sequence required. 4P - AAA (3P++PE) Type 1 IAC08X01AAA IACX01AAA IAC13X01AAA IAC16X01AAA IAC20X01AAA IAC25X01AAA IMC32X01AAA IMC41X01AAA IMC51X01AAA Type 2 IAC08X02AAA IACX02AAA IAC13X02AAA IAC16X02AAA IAC20X02AAA IAC25X02AAA IMC32X02AAA IMC41X02AAA IMC51X02AAA Type 3 IAC08X03AAA IACX03AAA IAC13X03AAA IAC16X03AAA IAC20X03AAA IAC25X03AAA IMC32X03AAA IMC41X03AAA IMC51X03AAA Type S * IAC08X0SAAA IACX0SAAA IAC13X0SAAA IAC16X0SAAA IAC20X0SAAA IAC25X0SAAA IMC32X0SAAA IMC41X0SAAA IMC51X0SAAA 5P - BAA (3P++FE+PE) - GAA (3P++FE/2+PE) - DAA (3P+2+PE) Type 1 IAC08X01BAA IACX01BAA IAC13X01BAA IAC16X01BAA IAC20X01BAA IAC25X01BAA IMC32X01BAA IMC41X01BAA IMC51X01BAA Type 2 IAC08X02BAA IACX02BAA IAC13X02BAA IAC16X02BAA IAC20X02BAA IAC25X02BAA IMC32X02BAA IMC41X02BAA IMC51X02BAA Type 3 IAC08X03BAA IACX03BAA IAC13X03BAA IAC16X03BAA IAC20X03BAA IAC25X03BAA IMC32X03BAA IMC41X03BAA IMC51X03BAA Type 4 IAC08X04BAA IACX04BAA IAC13X04BAA IAC16X04BAA IAC20X04BAA IAC25X04BAA IMC32X04BAA IMC41X04BAA IMC51X04BAA Type 5 IAC08X05BAA IACX05BAA IAC13X05BAA IAC16X05BAA IAC20X05BAA IAC25X05BAA IMC32X05BAA IMC41X05BAA IMC51X05BAA Type 6 IAC08X06BAA IACX06BAA IAC13X06BAA IAC16X06BAA IAC20X06BAA IAC25X06BAA IMC32X06BAA IMC41X06BAA IMC51X06BAA Type 7 IAC08X07BAA IACX07BAA IAC13X07BAA IAC16X07BAA IAC20X07BAA IAC25X07BAA IMC32X07BAA IMC41X07BAA IMC51X07BAA Type S * IAC08X0SBAA IACX0SBAA IAC13X0SBAA IAC16X0SBAA IAC20X0SBAA IAC25X0SBAA IMC32X0SBAA IMC41X0SBAA IMC51X0SBAA * For special versions, please contact our technical department. BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type S * FE () Cast resin insulation Type 1 () FE Type 2 () FE Type 3 () FE Y Type 4 () FE - - - - - - - - Type 5 () FE Type 6 () FE Type 7 () FE Type S * - - - - - - - - - - (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 = 590 = 00 H Y+25 H+50 (Y) 4P 5P AAA BAA GAA DAA 132 4-19 -

TRUKIG ELEMETS SECTIO ISOLATOR Technical data see pg. 51 These elements are used when it is necessary to divide or electrically protect parts of the busbar. The standard version has a switch-disconnector and a fuse holder (fuses not included). Type 1 IAC08K11AAA IACK11AAA IAC13K11AAA IAC16K11AAA IAC20K11AAA IAC25K11AAA IMC32K11AAA IMC41K11AAA IMC51K11AAA Type 2 IAC08K12AAA IACK12AAA IAC13K12AAA IAC16K12AAA IAC20K12AAA IAC25K12AAA IMC32K12AAA IMC41K12AAA IMC51K12AAA Type 3 IAC08K13AAA IACK13AAA IAC13K13AAA IAC16K13AAA IAC20K13AAA IAC25K13AAA IMC32K13AAA IMC41K13AAA IMC51K13AAA Type 4 IAC08K14AAA IACK14AAA IAC13K14AAA IAC16K14AAA IAC20K14AAA IAC25K14AAA IMC32K14AAA IMC41K14AAA IMC51K14AAA Type 5 IAC08KAAA IACKAAA IAC13KAAA IAC16KAAA IAC20KAAA IAC25KAAA IMC32KAAA IMC41KAAA IMC51KAAA Type 6 IAC08K16AAA IACK16AAA IAC13K16AAA IAC16K16AAA IAC20K16AAA IAC25K16AAA IMC32K16AAA IMC41K16AAA IMC51K16AAA Type 7 IAC08K17AAA IACK17AAA IAC13K17AAA IAC16K17AAA IAC20K17AAA IAC25K17AAA IMC32K17AAA IMC41K17AAA IMC51K17AAA Type 8 IAC08K18AAA IACK18AAA IAC13K18AAA IAC16K18AAA IAC20K18AAA IAC25K18AAA IMC32K18AAA IMC41K18AAA IMC51K18AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE.B. When ordering, the input and output side of the circuit should be signed. For, please contact our technical department. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Type 8 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H Y (Y) 4P 5P AAA BAA GAA DAA 132 4-20 -

TRUKIG ELEMETS Technical data see pg. 51 RATIG REDUCER With switch-disconnector and fuse-holder This unit is used to connect two busbar trunking runs having different nominal ratings. Type 1 IAC081AAA IAC1AAA IAC131AAA IAC161AAA IAC201AAA IAC251AAA IMC321AAA IMC411AAA IMC511AAA Type 2 IAC082AAA IAC2AAA IAC132AAA IAC162AAA IAC202AAA IAC252AAA IMC322AAA IMC412AAA IMC512AAA Type 3 IAC083AAA IAC3AAA IAC133AAA IAC163AAA IAC203AAA IAC253AAA IMC323AAA IMC413AAA IMC513AAA Type 4 IAC084AAA IAC4AAA IAC134AAA IAC164AAA IAC204AAA IAC254AAA IMC324AAA IMC414AAA IMC514AAA Type 5 IAC085AAA IAC5AAA IAC135AAA IAC165AAA IAC205AAA IAC255AAA IMC325AAA IMC4AAA IMC5AAA Type 6 IAC086AAA IAC6AAA IAC136AAA IAC166AAA IAC206AAA IAC256AAA IMC326AAA IMC416AAA IMC516AAA Type 7 IAC087AAA IAC7AAA IAC137AAA IAC167AAA IAC207AAA IAC257AAA IMC327AAA IMC417AAA IMC517AAA Type 8 IAC088AAA IAC8AAA IAC138AAA IAC168AAA IAC208AAA IAC258AAA IMC328AAA IMC418AAA IMC518AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE.B. When ordering, the input and output side of the circuit should be signed. For, please contact our technical department. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Type 8 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H Y (Y) 4P 5P AAA BAA GAA DAA 132 4-21 -

TRUKIG ELEMETS EXPASIO ELEMET Technical data see pg. 51 This unit, standard length 00 mm, is used to absorb the movement along the axial direction of the busbar trunking due to thermal expansion of the system. Expansion unit should be installed: - Close to a building expansion joint - Straight busbar runs longer than 40 50m (every 20 25m) (ex - 50 m busbar run = 1 expansion unit in the middle) (ex - 80 m busbar run = 2 expansion units every 25 30m) IAC08J01AAA IACJ01AAA IAC13J01AAA IAC16J01AAA IAC20J01AAA IAC25J01AAA IMC32J01AAA IMC41J01AAA IMC51J01AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE 50 m = = 80 m = = = (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H Y 00 (Y) 4P 5P AAA BAA GAA DAA 132 4-22 -

COECTIO ELEMETS TERMIAL UIT Technical data see pg. 51 This unit is used to prepare the connection between the busbar trunking runs and the switchboard or the transformer. Standard RH IAC08M01AAA IACM01AAA IAC13M01AAA IAC16M01AAA IAC20M01AAA IAC25M01AAA IMC32M01AAA IMC41M01AAA IMC51M01AAA LH IAC08M02AAA IACM02AAA IAC13M02AAA IAC16M02AAA IAC20M02AAA IAC25M02AAA IMC32M02AAA IMC41M02AAA IMC51M02AAA Special * RH IAC08M11AAA IACM11AAA IAC13M11AAA IAC16M11AAA IAC20M11AAA IAC25M11AAA IMC32M11AAA IMC41M11AAA IMC51M11AAA LH IAC08M12AAA IACM12AAA IAC13M12AAA IAC16M12AAA IAC20M12AAA IAC25M12AAA IMC32M12AAA IMC41M12AAA IMC51M12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH.B. For flange and bar, please look at pg. 40-41 Y H * The terminal unit can be supplied in special version with: 1 - Distance between bars 2 - Hole positions 3 - Flange 4 - Bars length different from standard 250 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 200 4 1 3 2 (Y) 4P 5P AAA BAA GAA DAA 132 4-23 -

COECTIO ELEMETS TERMIAL UIT DIMESIOS The terminal units of the IMPACT trunking system are provided with the necessary bar spacings, hole position and flange dimension in order to allow the connection to various devices to be energized (switch-board, transformer etc...) Special are achievable on request according to agreement with our technical department. Cu 800A 2000A (AAA) (4P) 3P + + PE (BAA) (5P) 3P + + FE + PE (GAA) (5P) 3P + + FE/2 + PE (DAA) (5P) 3P + 2 + PE 132 4 4 4 56 200 200 140 450 0 140 340 250 570 570 1 1 1 1 1 1 1 1 1 1 0 120 340 0 250 200 0 120 340 0 250 120 120 120 120 120 120 120 70 120 120 120 200 570 1 1 1 1 1 0 120 340 0 250 Pe Pe Fe Pe Pe Fe 2 120 120 120 0 120 0 Ø 9 Ø 9 Ø 9 Ø 9 Cu 800A 00A 129 Cu 1250A 1600A 174 Cu 2000A 204 42 Pe 45 42 Pe 45 42 Pe 45 50 25 17,5 50 85 17,5 slot 13x20 25 50 35 60 35 130 slot 13x20 25 50 30 50 50 30 160 slot 13x20 Ø13 (Pe) drilling valid for all versions. 25* * (Fe) drilling valid for GAA version. 22,5 50 22,5 95-24 -

COECTIO ELEMETS TERMIAL UIT DIMESIOS The terminal units of the IMPACT trunking system are provided with the necessary bar spacings, hole position and flange dimension in order to allow the connection to various devices to be energized (switch-board, transformer etc...) Special are achievable on request according to agreement with our technical department. Cu 2500A 5000A (AAA) (4P) 3P + + PE (BAA) (5P) 3P + + FE + PE (GAA) (5P) 3P + + FE/2 + PE (DAA) (5P) 3P + 2 + PE 132 4 4 4 250 200 120 120 120 200 450 140 0 140 570 1 1 1 1 1 130 130 540 130 130 250 56 120 120 120 120 570 1 1 1 1 1 130 130 540 130 130 250 70 120 120 120 200 570 1 1 1 1 1 130 130 540 130 130 250 Pe Pe Fe Pe Pe 200 Fe 2 120 120 120 130 130 540 130 130 Ø 9 Ø 9 Ø 9 Ø 9 Cu 2500A 3200A 312 Cu 4000A 372 Cu 5000A 452 42 Pe 45 Pe Pe Pe 45 Pe 45 Pe 42 42 50 25 35 60 77,5 60 22,5 slot 13x20 50 25 30 50 50 67,5 50 50 30 slot 13x20 50 25 25 50 50 50 57,5 50 50 50 25 slot 13x20 130 130 7,5 160 160 7,5 200 200 7,5-25 -

COECTIO ELEMETS FLAT ELBOW + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08P11AAA IACP11AAA IAC13P11AAA IAC16P11AAA IAC20P11AAA IAC25P11AAA IMC32P11AAA IMC41P11AAA IMC51P11AAA Type 2 IAC08P12AAA IACP12AAA IAC13P12AAA IAC16P12AAA IAC20P12AAA IAC25P12AAA IMC32P12AAA IMC41P12AAA IMC51P12AAA Type 3 IAC08P13AAA IACP13AAA IAC13P13AAA IAC16P13AAA IAC20P13AAA IAC25P13AAA IMC32P13AAA IMC41P13AAA IMC51P13AAA Type 4 IAC08P14AAA IACP14AAA IAC13P14AAA IAC16P14AAA IAC20P14AAA IAC25P14AAA IMC32P14AAA IMC41P14AAA IMC51P14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 H (B) + H/2 (B) (A) + H/2 (A) Y (A) (B) 800A 2000A Cu std 300 300 min 300 0 max 899 549 2500A 5000A Cu std 450 450 min 450 250 max 49 49 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 200.B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-26 -

COECTIO ELEMETS DIHEDRAL ELBOW + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08Q11AAA IACQ11AAA IAC13Q11AAA IAC16Q11AAA IAC20Q11AAA IAC25Q11AAA IMC32Q11AAA IMC41Q11AAA IMC51Q11AAA Type 2 IAC08Q12AAA IACQ12AAA IAC13Q12AAA IAC16Q12AAA IAC20Q12AAA IAC25Q12AAA IMC32Q12AAA IMC41Q12AAA IMC51Q12AAA Type 3 IAC08Q13AAA IACQ13AAA IAC13Q13AAA IAC16Q13AAA IAC20Q13AAA IAC25Q13AAA IMC32Q13AAA IMC41Q13AAA IMC51Q13AAA Type 4 IAC08Q14AAA IACQ14AAA IAC13Q14AAA IAC16Q14AAA IAC20Q14AAA IAC25Q14AAA IMC32Q14AAA IMC41Q14AAA IMC51Q14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 Y (B) + (Y/2) (B) 300 (A) + (Y/2) (A) 300 H (A) (B) 800A 5000A Cu std 300 300 min 250 0 max 849 499 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 200.B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-27 -

COECTIO ELEMETS DOUBLE FLAT ELBOW + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08R11AAA IACR11AAA IAC13R11AAA IAC16R11AAA IAC20R11AAA IAC25R11AAA IMC32R11AAA IMC41R11AAA IMC51R11AAA Type 2 IAC08R12AAA IACR12AAA IAC13R12AAA IAC16R12AAA IAC20R12AAA IAC25R12AAA IMC32R12AAA IMC41R12AAA IMC51R12AAA Type 3 IAC08R13AAA IACR13AAA IAC13R13AAA IAC16R13AAA IAC20R13AAA IAC25R13AAA IMC32R13AAA IMC41R13AAA IMC51R13AAA Type 4 IAC08R14AAA IACR14AAA IAC13R14AAA IAC16R14AAA IAC20R14AAA IAC25R14AAA IMC32R14AAA IMC41R14AAA IMC51R14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 Y H (A) + (C) (A) (C) (A) (B) (C) mm 800A 2000A Cu std 300 300 300 min 300 50 0 max 899 599 549 2500A 5000A Cu std 450 450 450 min 450 50 250 max 49 899 699 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 200 (B) (B) + (H).B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-28 -

COECTIO ELEMETS DOUBLE DIHEDRAL ELBOW + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08S11AAA IACS11AAA IAC13S11AAA IAC16S11AAA IAC20S11AAA IAC25S11AAA IMC32S11AAA IMC41S11AAA IMC51S11AAA Type 2 IAC08S12AAA IACS12AAA IAC13S12AAA IAC16S12AAA IAC20S12AAA IAC25S12AAA IMC32S12AAA IMC41S12AAA IMC51S12AAA Type 3 IAC08S13AAA IACS13AAA IAC13S13AAA IAC16S13AAA IAC20S13AAA IAC25S13AAA IMC32S13AAA IMC41S13AAA IMC51S13AAA Type 4 IAC08S14AAA IACS14AAA IAC13S14AAA IAC16S14AAA IAC20S14AAA IAC25S14AAA IMC32S14AAA IMC41S14AAA IMC51S14AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 4 (A) (B) (C) mm 800A 5000A Cu std 300 300 300 min 250 50 0 max 849 499 499 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (B) 300 Y (B) + Y H 200 (C) 300 (A) 300 (A) + (C).B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-29 -

COECTIO ELEMETS FLAT ELBOW + DIHEDRAL + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08T11AAA IACT11AAA IAC13T11AAA IAC16T11AAA IAC20T11AAA IAC25T11AAA IMC32T11AAA IMC41T11AAA IMC51T11AAA Type 2 IAC08T12AAA IACT12AAA IAC13T12AAA IAC16T12AAA IAC20T12AAA IAC25T12AAA IMC32T12AAA IMC41T12AAA IMC51T12AAA Type 3 IAC08T13AAA IACT13AAA IAC13T13AAA IAC16T13AAA IAC20T13AAA IAC25T13AAA IMC32T13AAA IMC41T13AAA IMC51T13AAA Type 4 IAC08T14AAA IACT14AAA IAC13T14AAA IAC16T14AAA IAC20T14AAA IAC25T14AAA IMC32T14AAA IMC41T14AAA IMC51T14AAA Type 5 IAC08TAAA IACTAAA IAC13TAAA IAC16TAAA IAC20TAAA IAC25TAAA IMC32TAAA IMC41TAAA IMC51TAAA Type 6 IAC08T16AAA IACT16AAA IAC13T16AAA IAC16T16AAA IAC20T16AAA IAC25T16AAA IMC32T16AAA IMC41T16AAA IMC51T16AAA Type 7 IAC08T17AAA IACT17AAA IAC13T17AAA IAC16T17AAA IAC20T17AAA IAC25T17AAA IMC32T17AAA IMC41T17AAA IMC51T17AAA Type 8 IAC08T18AAA IACT18AAA IAC13T18AAA IAC16T18AAA IAC20T18AAA IAC25T18AAA IMC32T18AAA IMC41T18AAA IMC51T18AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 5 Type 6 Type 7 Type 4 (B) + (Y/2) + (H/2) (B) H Y Type 8 (A) + H/2 (A) (A) (B) (C) mm 800A 2000A Cu std 300 300 300 min 300 2 0 max 899 549 499 2500A 5000A Cu std 450 300 300 min 450 320 0 max 49 699 499 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (C) 300 (C) + (Y/2) 200.B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-30 -

COECTIO ELEMETS DIHEDRAL + FLAT ELBOW + TERMIAL UIT Technical data see pg. 51 This unit is used, in particular situations, to facilitate the connection between the busbar trunking runs and the switchboard or the transformer. Type 1 IAC08U11AAA IACU11AAA IAC13U11AAA IAC16U11AAA IAC20U11AAA IAC25U11AAA IMC32U11AAA IMC41U11AAA IMC51U11AAA Type 2 IAC08U12AAA IACU12AAA IAC13U12AAA IAC16U12AAA IAC20U12AAA IAC25U12AAA IMC32U12AAA IMC41U12AAA IMC51U12AAA Type 3 IAC08U13AAA IACU13AAA IAC13U13AAA IAC16U13AAA IAC20U13AAA IAC25U13AAA IMC32U13AAA IMC41U13AAA IMC51U13AAA Type 4 IAC08U14AAA IACU14AAA IAC13U14AAA IAC16U14AAA IAC20U14AAA IAC25U14AAA IMC32U14AAA IMC41U14AAA IMC51U14AAA Type 5 IAC08UAAA IACUAAA IAC13UAAA IAC16UAAA IAC20UAAA IAC25UAAA IMC32UAAA IMC41UAAA IMC51UAAA Type 6 IAC08U16AAA IACU16AAA IAC13U16AAA IAC16U16AAA IAC20U16AAA IAC25U16AAA IMC32U16AAA IMC41U16AAA IMC51U16AAA Type 7 IAC08U17AAA IACU17AAA IAC13U17AAA IAC16U17AAA IAC20U17AAA IAC25U17AAA IMC32U17AAA IMC41U17AAA IMC51U17AAA Type 8 IAC08U18AAA IACU18AAA IAC13U18AAA IAC16U18AAA IAC20U18AAA IAC25U18AAA IMC32U18AAA IMC41U18AAA IMC51U18AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 Type 2 Type 3 Type 5 Type 4 Type 6 Type 7 H Type 8 Y (A) 300 (A) + (Y/2) (A) (B) (C) mm 800A 2000A Cu std 300 300 300 min 250 2 0 max 849 549 549 2500A 5000A Cu std 300 300 450 min 250 320 230 max 849 699 699 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (C) (C) + (H/2) 200 (B) (B) + (Y/2) + (H/2).B. For flange and bar, please see pg. 40-41 (Y) 4P 5P AAA BAA GAA DAA 132 4-31 -

COECTIO ELEMETS TERMIAL UIT WITH PARALLEL PHASES Technical data see pg. 51 This unit is used to prepare the connection between the busbar trunking run and the resin transformer. Type 1 IAC0811AAA IAC11AAA IAC1311AAA IAC1611AAA IAC2011AAA IAC2511AAA IMC3211AAA IMC4111AAA IMC5111AAA Type 2 IAC0812AAA IAC12AAA IAC1312AAA IAC1612AAA IAC2012AAA IAC2512AAA IMC3212AAA IMC4112AAA IMC5112AAA Type 3 IAC0813AAA IAC13AAA IAC1313AAA IAC1613AAA IAC2013AAA IAC2513AAA IMC3213AAA IMC4113AAA IMC5113AAA Type 4 IAC0814AAA IAC14AAA IAC1314AAA IAC1614AAA IAC2014AAA IAC2514AAA IMC3214AAA IMC4114AAA IMC5114AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Phase/neutral sequence to be defined when ordering Type 1 Type 2 Type 3 Type 4.B. For correct, please contact our technical department. (min) 400 A max 2850 40 (min) A1 A1 A1 250 Pe 200 90 Rating A A1 800A Cu - 00A Cu 85 A+40 1250A Cu 130 A+40 1600A Cu 130 A+40 2000A Cu 160 A+40 2500A Cu 130 A+40 3200A Cu 130 A+40 4000A Cu 160 A+40 5000A Cu 200 A+40 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 Bar 85 Bar 130 Bar 160 Bar 200 17,5 50 17,5 50 50 50 50 25 35 60 35 25 30 50 50 30 85 130 160 200 25 25 50 50 50 25 25 (Y) 4P 5P AAA BAA GAA DAA 132 4-32 -

COECTIO ELEMETS ED FEED Technical data see pg. 51 This unit is used if the busbar trunking system is fed by cables. Standard DX RH IAC08V01AAA IACV01AAA IAC13V01AAA IAC16V01AAA IAC20V01AAA IAC25V01AAA IMC32V01AAA IMC41V01AAA IMC51V01AAA SX LH IAC08V02AAA IACV02AAA IAC13V02AAA IAC16V02AAA IAC20V02AAA IAC25V02AAA IMC32V02AAA IMC41V02AAA IMC51V02AAA Special DX RH IAC08V11AAA IACV11AAA IAC13V11AAA IAC16V11AAA IAC20V11AAA IAC25V11AAA IMC32V11AAA IMC41V11AAA IMC51V11AAA SX LH IAC08V12AAA IACV12AAA IAC13V12AAA IAC16V12AAA IAC20V12AAA IAC25V12AAA IMC32V12AAA IMC41V12AAA IMC51V12AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE DX RH SX LH (A) = (H) = 00 750 250 = (C) = (D) (A) (B) (C) 800A 2000A Cu 380 600 290 400 2500A 5000A Cu 600 600 490 400 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 = Y = (B) = (D) = cables entrance (Y) 4P 5P AAA BAA GAA DAA 132 4-33 -

COECTIO ELEMETS ED FEED UIT FOR VERTICAL RUS Technical data see pg. 51 This unit is used to feed the busbar trunking system by cable in high-rise vertical runs. The busbars position in relation to the box body allows the installation of the unit on the wall allowing the use of vertical run fixing units. (pg 84) Type 1 IAC08V31AAA IACV31AAA IAC13V31AAA IAC16V31AAA IAC20V31AAA IAC25V31AAA IMC32V31AAA IMC41V31AAA IMC51V31AAA Type 2 IAC08V32AAA IACV32AAA IAC13V32AAA IAC16V32AAA IAC20V32AAA IAC25V32AAA IMC32V32AAA IMC41V32AAA IMC51V32AAA Type 3 IAC08V33AAA IACV33AAA IAC13V33AAA IAC16V33AAA IAC20V33AAA IAC25V33AAA IMC32V33AAA IMC41V33AAA IMC51V33AAA Type 4 IAC08V34AAA IACV34AAA IAC13V34AAA IAC16V34AAA IAC20V34AAA IAC25V34AAA IMC32V34AAA IMC41V34AAA IMC51V34AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE Type 1 55 H (A) Y Type 2 Type 3 Type 4 00 750 250 (B) (D) (A) (B) (C) 800A 2000A Cu 380 600 290 400 2500A 5000A Cu 600 600 490 400 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (D) = = cables entrance = (B) = (Y) 4P 5P AAA BAA GAA DAA 132 4-34 -

COECTIO ELEMETS CETER FEED UIT Technical data see pg. 51 This unit is used as a feed unit (by cables) in the mid point of a busbar trunking run. DX RH IAC08V41AAA IACV41AAA IAC13V41AAA IAC16V41AAA IAC20V41AAA IAC25V41AAA IMC32V41AAA IMC41V41AAA IMC51V41AAA SX LH IAC08V42AAA IACV42AAA IAC13V42AAA IAC16V42AAA IAC20V42AAA IAC25V42AAA IMC32V42AAA IMC41V42AAA IMC51V42AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE RH LH 400 600 = (Y) = cables entrance 10 250 600 250 490 Cu (A) (B) 630A 1 640 800A 00A 1250A 132 618 1600A 2000A 147 603 2500A 211 549 3200A 4000A 231 519 2000A 251 499 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 (B) (A) 750 H (Y) 4P 5P AAA BAA GAA DAA 132 4-35 -

COECTIO ELEMETS ED FEED UIT WITH SWITCH-DISCOECTOR Technical data see pg. 51 This unit is used as a busbar trunking feeder. The standard version is offered with a switch-disconnector. On request, a fuseholder or an automatic switch (MCCB) is available. Cu 800A 00A 1250A 1600A 2000A 2500A 3200A 4000A 5000 Type 1 IAC08V21AAA IACV21AAA IAC13V21AAA IAC16V21AAA IAC20V21AAA IAC25V21AAA IMC32V21AAA IMC41V21AAA IMC51V21AAA Type 2 IAC08V22AAA IACV22AAA IAC13V22AAA IAC16V22AAA IAC20V22AAA IAC25V22AAA IMC32V22AAA IMC41V22AAA IMC51V22AAA Type 3 IAC08V23AAA IACV23AAA IAC13V23AAA IAC16V23AAA IAC20V23AAA IAC25V23AAA IMC32V23AAA IMC41V23AAA IMC51V23AAA Type 4 IAC08V24AAA IACV24AAA IAC13V24AAA IAC16V24AAA IAC20V24AAA IAC25V24AAA IMC32V24AAA IMC41V24AAA IMC51V24AAA Type 5 IAC08V25AAA IACV25AAA IAC13V25AAA IAC16V25AAA IAC20V25AAA IAC25V25AAA IMC32V25AAA IMC41V25AAA IMC51V25AAA Type 6 IAC08V26AAA IACV26AAA IAC13V26AAA IAC16V26AAA IAC20V26AAA IAC25V26AAA IMC32V26AAA IMC41V26AAA IMC51V26AAA Type 7 IAC08V27AAA IACV27AAA IAC13V27AAA IAC16V27AAA IAC20V27AAA IAC25V27AAA IMC32V27AAA IMC41V27AAA IMC51V27AAA Type 8 IAC08V28AAA IACV28AAA IAC13V28AAA IAC16V28AAA IAC20V28AAA IAC25V28AAA IMC32V28AAA IMC41V28AAA IMC51V28AAA AAA = 3P + + PE BAA = 3P + + FE + PE GAA = 3P + + FE/2 + PE DAA = 3P + 2 + PE.B. For and volumes, please contact our technical department. Type 1 Type 2 Type 3 Type 4 Type 5 Type 7 Type 8 Type 6 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H Y (Y) 4P 5P AAA BAA GAA DAA 132 4-36 -

TAP-OFF UITS TAP-OFF UIT (CLAMPS PIS) With fuse holder (fuses not included) This unit is used to take power from the busbar trunking straight elements. The tap-off unit is equipped with a fuseholder (fuses not included). ominal rating from 63A to 3A. cables exit (A) (B) (C) (D) Code fuse size 63A IMX00WF1AAA 420 280 170 525 H00 160A IMX00WF2AAA 520 320 2 650 H00 250A IMX00WF3AAA 520 320 2 650 H1 3A IMX00WF4AAA 620 320 245 750 H2 (C) 50 (D) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available (B) 70 (A) - 70 (A).B. For further information, please contact our technical department. With switch-disconnector + fuse holder (fuses not included) This unit is used to take power from the busbar trunking straight elements. The tap-off unit is equipped with a rotary switch-disconnector (AC23A) and fuse holder (fuses not included). ominal rating from 63A to 250A. cables exit (A) (B) (C) (D) Code fuse size 63A IMX00WF5AAA 520 320 2 650 H00 160A IMX00WF8AAA 520 320 2 650 H00 250A IMX00WF9AAA 700 320 245 855 H1 (C) 50 (D) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available (B) 70 (A) - 70 (A).B. For further information, please contact our technical department. - 37 -

TAP-OFF UITS TAP-OFF UIT (CLAMPS PIS) With switch-disconnector + fuse holder (fuses not included) This unit is used to take power from the busbar trunking straight elements. The tap-off unit is equipped with a rotary switch-disconnector (AC23A) and fuse holder (fuses not included). ominal rating from 400A to 630A. UITÀ DI DERIVAZIOE TAP-OFF UITS cables exit (A) (B) (C) (D) (E) Code fuse mm 400A IMX00WF6AAA 735 420 340 450 7 H3 630A IMX00WF7AAA 735 420 340 450 7 H3 (C) (E) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available (B) (D) 113 622,5 (A).B. For further information, please contact our technical department. Suitable for modular switches (MCB) This unit is used to take power from the busbar trunking only through distribution straight elements. It is suitable for the modular switches (MCB) insertion on the DI guide and it is available in 4 modules, 7.5 modules and 11 modules versions. ominal rating max 250A. On request, it can be supplied with modular switches included. cables exit (A) (B) (C) (D) ìcode 4 modules IMX00WM1AAA 420 280 170 525 250A 7,5 modules IMX00WM2AAA 420 280 170 525 11 modules IMX00WM3AAA 420 280 170 525 (C) 50 (D) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available (B) 70 (A) - 70 (A).B. For further information, please contact our technical department. - 38 -

TAP-OFF UITS TAP-OFF UIT (CLAMPS PIS) This unit is used to take power from the busbar trunking straight elements. It is suitable for the automatic switchdisconnectors (MCCB) insertion such as TMAX (ABB SACE), S (SCHEIDER ELECTRIC), DPX (LEGRAD) or RECORD PLUS (GEERAL ELECTRIC). The prearrangement has the fixed switches insertion with front terminals, equipped with transmitted rotating handle. The tap-off unit can be supplied prearranged (switch excluded) or with switch included. On request, prearrangements for switches with special equipment (residual current releases, energy motor operator, etc...) or prearrangements for different brand and type of switches. ominal rating form 63A to 3A. cables exit Suitable for TMAX (ABB SACE) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 63A IMX00WT1AAA 520 320 2 650 TMAX T1 160A IMX00WT2AAA 520 320 2 650 TMAX T2 250A IMX00WT3AAA 520 320 2 650 TMAX T3 3A IMX00WT4AAA 620 320 245 750 TMAX T4 Suitable for S (SCHEIDER ELECTRIC) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 160A IMX00W1AAA 520 320 2 650 S 160 250A IMX00W2AAA 520 320 2 650 S 250 Suitable for DPX (LEGRAD) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 63A IMX00WAAA 420 280 190 525 DPX 125 160A IMX00WAAA 520 320 2 650 DPX 160 250A IMX00WAAA 620 320 240 750 DPX 250 3A IMX00WL4AAA 700 320 245 855 DPX 630 Suitable for RECORD PLUS (GEERAL ELECTRIC) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 160A IMX00WG1AAA 520 320 2 650 FD 160 160A IMX00WG2AAA 620 320 245 750 FE 160 250A IMX00WG3AAA 620 320 245 750 FE 250 (C) 50 (D) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - 70 (A) - 70 to be used - not available (B) (A).B. For further information, please contact our technical department. - 39 -

TAP-OFF UITS TAP-OFF UIT (CLAMPS PIS) This unit is used to take power from the busbar trunking straight elements. It is suitable for the automatic switchdisconnectors insertion such as TMAX (ABB SACE), S (SCHEIDER ELECTRIC) o DPX (LEGRAD) or RECORD PLUS (GEERAL ELECTRIC). The prearrangement has the fixed switches insertion with front terminals, equipped with transmitted rotating handle. The tap-off unit can be supplied prearranged (switch excluded) or with switch included. On request, prearrangements for switches with special equipment (residual current releases, energy motor operator, etc...) or prearrangements for different brand and type of switches. ominal rating form 400A to 630A. cables exit Suitable for TMAX (ABB SACE) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 400A IMX00WT5AAA 735 420 340 7 TMAX T5 630A IMX00WT6AAA 735 420 340 7 TMAX T6 Suitable for S (SCHEIDER ELECTRIC) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 400A IMX00W3AAA 735 420 340 7 S 400 630A IMX00W4AAA 735 420 340 7 S 630 Suitable for DPX (LEGRAD) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 400A IMX00WL5AAA 735 420 340 7 DPX 630 500A IMX00WL6AAA 735 420 340 7 DPX 630 630A IMX00WL7AAA 735 420 340 7 DPX 630 Suitable for RECORD PLUS (GEERAL ELECTRIC) automatic switches (MCCB) Code (A) (B) (C) (D) MCCB type 400A IMX00WG4AAA 735+250* 420 340 7 FG 400 630A IMX00WG5AAA 735+250* 420 340 7 FG 630 (C) (D) (B) 113 622,5 (A) * *Extension only for Record plus mccb. - 40 -

TAP-OFF UITS TAP-OFF UIT (CLAMPS PIS) Empty This unit is used to take power from the busbar tunking straight elements. This unit does not have any protection device and/or switch-disconnector, so with the top cover open, the tap-off unit can be cabled even if already fixed on the busbar trunking energized. ominal rating from 63A to 3A. /// cavo MAX 95 mm 2 cables exit (A) (A1) (B) (B1) (C) (C1) (D) Code mm 63A IMX00WV1AAA 420 273 280 237 170 3 525 160A IMX00WV2AAA 520 374 320 277 2 193 650 250A 3A IMX00WV3AAA 620 474 320 277 245 228 750 (A1)(B1)(C1) Internal useful space (B) (C) 50 70 (A) - 70 (A) (D) Tap-off plug-in axis AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available.b. For further information, please contact our technical department. Empty This unit is used to take power from the busbar tunking straight elements. This unit does not have any protection device and/or switch-disconnector, so with the top cover open, the tap-off unit can be cabled only if the conductor is not energized. ominal rating from 400A to 630A. cables exit 400A 630A Code quotes (A) (A1) (B) (B1) (C) (C1) (D) mm IMX00WV7AAA 735 451 420 373 340 314 7 (A1)(B1)(C1) Internal useful space (D) AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - (C) to be used - not available Tap-off plug-in axis.b. For further information, please contact our technical department. (B) 113 622,5 (A) - 41 -

TAP-OFF UITS TAP-OFF UIT (TO FIT O THE JUCTIO) With switch-disconnector + fuse holder This unit is used to take power from the busbar trunking and it is installed on the junction between the two units. The tap-off unit is equipped with a rotary switch-disconnector (AC23A) with a fuse holder (fuses not inlcuded) and can be installed only if the busbar trunking is not energized. ominal rating from 125A/1250A. 800A Cu 1250A Cu 2500A Cu 00A Cu 1600A Cu 2000A Cu 3200A Cu 4000A Cu 5000A Cu fuse 125A IMX81W20AAA IMX83W20AAA IMX84W20AAA IMX92W20AAA IMX93W20AAA IMX96W20AAA H00 160A IMX81W21AAA IMX83W21AAA IMX84W21AAA IMX92W21AAA IMX93W21AAA IMX96W21AAA H1 300A IMX81W22AAA IMX83W22AAA IMX84W22AAA IMX92W22AAA IMX93W22AAA IMX96W22AAA H2 500A IMX81W23AAA IMX83W23AAA IMX84W23AAA IMX92W23AAA IMX93W23AAA IMX96W23AAA H3 630A IMX81W24AAA IMX83W24AAA IMX84W24AAA IMX92W24AAA IMX93W24AAA IMX96W24AAA H3 800A IMX81W25AAA IMX83W25AAA IMX84W25AAA IMX92W25AAA IMX93W25AAA IMX96W25AAA H4 1250A IMX81W27AAA IMX83W27AAA IMX84W27AAA IMX92W27AAA IMX93W27AAA IMX96W27AAA H4 AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available.b. For further information, please contact our technical department. 125 (A) H (D) (C) 65 Suitable for automatic switch-disconnector (MCCB) This unit is used to take power from the busbar trunking straight and it is installed on the junction between the two units. The tap-off unit is suitable for an automatic switch prearrangement that has to be specified during the order phase (brand and model). On request, the tap-off unit can be supplied only prearranged (switch not included) or with the switch (switch installed). ominal rating from 125A/1250A 132 (B) 800A Cu 1250A Cu 2500A Cu 00A Cu 1600A Cu 2000A Cu 3200A Cu 4000A Cu 5000A Cu 125A IMX81W40AAA IMX83W40AAA IMX84W40AAA IMX92W40AAA IMX93W40AAA IMX96W40AAA 160A IMX81W41AAA IMX83W41AAA IMX84W41AAA IMX92W41AAA IMX93W41AAA IMX96W41AAA 300A IMX81W42AAA IMX83W42AAA IMX84W42AAA IMX92W42AAA IMX93W42AAA IMX96W42AAA 500A IMX81W43AAA IMX83W43AAA IMX84W43AAA IMX92W43AAA IMX93W43AAA IMX96W43AAA 630A IMX81W44AAA IMX83W44AAA IMX84W44AAA IMX92W44AAA IMX93W44AAA IMX96W44AAA 800A IMX81W45AAA IMX83W45AAA IMX84W45AAA IMX92W45AAA IMX93W45AAA IMX96W45AAA 1250A IMX81W47AAA IMX83W47AAA IMX84W47AAA IMX92W47AAA IMX93W47AAA IMX96W47AAA For correct, please contact our technical department. (A) (B) (C) (D) 125A 650 320 250 550 160A 650 320 250 550 300A 650 320 250 550 500A 750 450 300 730 630A 750 450 300 730 800A 1200 550 300 830 1250A 1200 550 300 830-42 -

TAP-OFF UITS TAP-OFF UIT (TO FIT O THE JUCTIO) Empty This unit is used to take power from the busbar tunkings and it is installed on the junction between the two units. This unit does not have any protection device, so the tap-off unit can be installed and cabled only if the conductor is not energized. ominal rating from 125A /1250A. 800A Cu 1250A Cu 2500A Cu 00A Cu 1600A Cu 2000A Cu 3200A Cu 4000A Cu 5000A Cu 125A IMX81W30AAA IMX83W30AAA IMX84W30AAA IMX92W30AAA IMX93W30AAA IMX96W30AAA 160A IMX81W31AAA IMX83W31AAA IMX84W31AAA IMX92W31AAA IMX93W31AAA IMX96W31AAA 300A IMX81W32AAA IMX83W32AAA IMX84W32AAA IMX92W32AAA IMX93W32AAA IMX96W32AAA 500A IMX81W33AAA IMX83W33AAA IMX84W33AAA IMX92W33AAA IMX93W33AAA IMX96W33AAA 630A IMX81W34AAA IMX83W34AAA IMX84W34AAA IMX92W34AAA IMX93W34AAA IMX96W34AAA 800A IMX81W35AAA IMX83W35AAA IMX84W35AAA IMX92W35AAA IMX93W35AAA IMX96W35AAA 1250A IMX81W37AAA IMX83W37AAA IMX84W37AAA IMX92W37AAA IMX93W37AAA IMX96W37AAA AAA = 3P + + PE BAA = 3P + + FE + PE RAA = 3P + P + PE SAA = 3P + P + FE + PE DAA = 3P + 2 + PE conductor AAA BAA GAA DAA - - - - - - - - - - - - - to be used - not available.b. For further information, please contact our technical department. For correct, please contact our technical department. 125 (A) (A) (A1) (B) (B2) (C) (C3) (D) 132 (B) (D) (C) H 125A 650 289 320 293 250 207 550 160A 650 289 320 293 250 207 550 300A 650 289 320 293 250 207 550 500A 750 364 450 423 300 266 730 630A 750 364 450 423 300 266 730 800A 1200 789 550 523 300 282 830 1250A 1200 789 550 523 300 282 830 (A1) (B1) (C1) Internal useful space - 43 -

ACCESSORIES ED COVER This unit is used to guarantee the IP55 degree of protection on the end of the busbar trunking run. On request, IP66 is available only for feeder runs (without tap-off units). IMX81Y01AAA IMX81Y01AAA IMX83Y01AAA IMX83Y01AAA IMX84Y01AAA IMX92Y01AAA IMX92Y01AAA IMX93Y01AAA IMX96Y01AAA AAA = 3P + + PE BAA = BAA 3P + + FE + PE = GAA 3P + + FE/2 + PE = DAA 3P + 2 + PE Y 1770 H + 23 340 JOIT COVER This unit is used to guarantee the IP55 degree of protection on the junction between two units of the busbar trunking run. On request, IP66 version is available only for transport runs (without tap-off units) IMX81Z01AAA IMX81Z01AAA IMX83Z01AAA IMX83Z01AAA IMX84Z01AAA IMX92Z01AAA IMX92Z01AAA IMX93Z01AAA IMX96Z01AAA All the seals are supplied already assembled on the respective flanges (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 H + 23 Y = = 335 (Y) 4P 5P AAA BAA GAA DAA 132 4-44 -

ACCESSORIES FIRE BARRIER This unit is used to maintain the fire wall resistance class, when a busbar is passing through a wall, in order to avoid the transmission of fire, combustive gas and temperature. This unit is composed of special external panels and is positioned internally where the busbar passes through the wall. The busbar trunking run (straight trunking, elbows etc...) with the internal position (code IM...AF) has to be prepared in factory while the external part can be supplied already assembled on the busbar trunking run or supplied disassembled to be assembled on site. The unit has the following fire resistance class: EI 180 (180 minutes) in accordance to E 1366-3 IMX814AAA IMX814AAA IMX834AAA IMX834AAA IMX844AAA IMX924AAA IMX924AAA IMX934AAA IMX964AAA AAA = 3P + + PE BAA = BAA 3P + + FE + PE = GAA 3P + + FE/2 + PE = DAA 3P + 2 + PE min 40 min 40 min 40 A = = External gap not supplied min 40 C B ACCESSORIES WALL FLAGE This unit is used to cover the hole on the wall through which the busbar trunking passes. The gap material is not included and the unit can be applied even in the presence of the fire barrier unit. For and characteristics, please contact our technical department. IMX81911AAA IMX81911AAA IMX83911AAA IMX83911AAA IMX84911AAA IMX92911AAA IMX92911AAA IMX93911AAA IMX96911AAA For further information, please contact our technical department. quotes 4P 5P Cu (A) (B) (C) (A) (B) (C) 800A 630 212 2 630 234 2 00A 1250A 630 212 260 630 234 260 1600A 2000A 630 212 290 630 234 290 2500A 830 212 398 830 234 398 3200A 4000A 830 212 458 830 234 458 5000A 830 212 538 830 234 538-45 -

ACCESSORIES CAOPY This unit is used in outdoor installations as an extra protection. EDGEWISE IMX81601AAA IMX81601AAA IMX83601AAA IMX83601AAA IMX84601AAA IMX92601AAA IMX92601AAA IMX93601AAA IMX96601AAA FLAT IMX81602AAA IMX81602AAA IMX83602AAA IMX83602AAA IMX84602AAA IMX92602AAA IMX92602AAA IMX93602AAA IMX96602AAA AAA = 3P + + PE BAA = BAA 3P + + FE + PE = GAA 3P + + FE/2 + PE = DAA 3P + 2 + PE Edgewise Flat A B B 1 A 1 4P 5P Cu bar (A) (B) (A1) (B1) (A) (B) (A1) (B1) 800A B85 140 260 0 276 140 282 172 276 00A 1250A B130 185 260 0 276 140 282 172 276 1600A B130 185 260 0 321 185 282 172 321 2000A B160 2 260 0 351 2 282 172 351 2500A 2B130 322 260 0 459 322 282 172 459 3200A 2B130 322 260 0 459 322 282 172 459 4000A 2B160 382 260 0 519 382 282 172 519 5000A 2B200 462 260 0 599 462 282 172 599 Edgewise Flat - 46 -

SUSPESIO UITS UIVERSAL FIXIG UIT This unit is used to fix the busbar trunking unit to the suspension unit on horizontal runs (always) or vertical (only for short runs 6 7 m) Code for all versions IMX007AAA installation Edgewise installation max 00 mm 71 40 163 (4P) - 185 (5P) 193 (4P) - 2 (5P) Torque moment ~ 25 m installation Flat installation (A) 800A Cu 160 00A Cu 160 1250A Cu 205 1600A Cu 205 2000A Cu 235 2500A Cu 343 3200A Cu 343 4000A Cu 403 5000A Cu 483 Torque moment ~ 25 m (A) - 47 -

SUSPESIO UITS FOR VERTICAL RUS (HIGH-RISE) These units are used to suspend the busbar trunking on vertical runs fixing them to the wall. Bracket for vertical run alignment IMX00720AAA Fixing unit for vertical runs IMX00730AAA installation 247 0 230 55 1 2 3 4 230 55 Torque moment ~ 25 m - 48 -

SUSPESIO UITS VERTICAL BRACKETS ISTALLATIO SCHEME The fixing unit with springs is used to suspend the busbar (it Is the device that supports the busbar) while the alignment unit is used to maintain the busbar in line along its own axis. It is necessary to install the brackets along the vertical run using at least one spring bracket for each single straight element, insert an alignment bracket between (the inter axis suggested is 1,5m) as indicated in the plan 3 even in this case the inter axis suggested is 1,5 m). A Alignment unit B 00 00 00 00 00 00 A B Spring fixing unit B A Tap-off unit It is very important that each single spring bracket is not carrying a load superior to 0kg. The verification must be done dividing the total weight of the line ( the busbar trunking run weight plus the possible future tap-off units) for the number of spring brackets as indicated in the following formula: P = total busbar trunking run weight (calculated according to plan 1) plus the weight of all the tap-off units programmed and the future ones ( calculated according to the plan 2) K = max load for each fixing unit with springs (0KG) = number of spring fixing units P = < 0kg (K) B A In case the load on each single bracket is superior to 0 kg, it is necessary to increase their number reducing the number of alignment brackets. Conductor weight Tap-off unit weight Alignment unit Spring fixing unit B A 00 Cu Kg/m 800A 28 00A 28 1250A 42 1600A 47 2000A 55 2500A 71 3200A 76 4000A 6 5000A 148 Kg 125A 30 250A 35 400A 45 630A 55 800A 60 00A 65 1250A 70-49 -

SUSPESIO UITS FOR VERTICAL RUS (HIGH-RISE) FLOOR FIXIG This unit is used to suspend the busbar trunking vertical run, fixing them to the floor. The bracket can be used as single with a max load of 0kg or double with a max load of 300kg. The bracket can be fixed directly on the floor or on a support profile (not included). Floor bracket fixing IMX00740AAA Single bracket (max 0kg) Double bracket (max 300kg) 1 H 1 H 1 Single bracket Double bracket 250 profile not included 83 (H) Cu mm 800A 129 00A 129 1250A 174 1600A 174 2000A 204 2500A 312 3200A 312 4000A 372 5000A 452 295 17,5 17,5 =755555 75= For correct, please contact our technical department. (Y) 4P 5P AAA BAA GAA DAA 132 4-50 -

TECHICAL DATA (AAA) 3P + + PE Cu COPPER The technical data for each rating is obtained from the results of tests carried out according to IEC-E 61439-1&6 and shown in the LOVAG Certificates. o data are obtained from extrapolation. * Tested (laboratory limit) ** Calculated A (50 C) 800 00 1250 1600 2000 2500 3200 4000 5000 ominal rating General Information Reference Standard IEC-E 61439-1 / IEC-E 61439-6 Rated Operational Voltage - U e V 00 Rated Insulation Voltage - U i V 00 Frequency Hz 50 Protection degree IP IP 55 - (on request IP66) Currents permitted Phase rated short-circuit withstand (1s) -I cw 50 50 80 80 90 93 120 * 120 * 120 * 144 ** 162 ** 167 ** Phase rated peak short-circuit withstand (1s) - I pk 1 1 176 176 198 205 264 * 264 * 264 * 316 ** 356 ** 367 ** Conductors Phase cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) eutral cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) Phase resistance R 20 mω/m 0,047 0,047 0,033 0,029 0,024 0,017 0,016 0,012 0,011 Phase reactance - X t mω/m 0,029 0,029 0,020 0,018 0,018 0,016 0,016 0,013 0,007 Phase impedence - Z t mω/m 0,067 0,067 0,046 0,040 0,037 0,025 0,027 0,022 0,016 (1) Phase resistance at thermal conditions - R t mω/m 0,060 0,060 0,041 0,037 0,033 0,019 0,021 0,017 0,014 Protection conductor (casing) Cross-section (Enclosure) mm 2 1.229 1.229 1.538 1.538 1.848 2.820 2.820 3.441 4.037 Cross-section (=Cu) (Enclosure) mm 2 737 737 923 923 1.9 1.692 1.692 2.065 2.422 Others features Fault loop resistence - R o Ph-Ph (1) mω/m 0,161 0,161 0,114 0,1 0,091 0,062 0,073 0,054 0,042 Fault loop reactance - X o Ph-Ph (1) mω/m 0,094 0,094 0,077 0,077 0,064 0,042 0,046 0,035 0,029 Fault loop impedence - Z o Ph-Ph (1) mω/m 0,186 0,186 0,137 0,134 0,117 0,075 0,087 0,065 0,051 Fault loop resistence - R o Ph-PE (1) mω/m 0,4 0,4 0,119 0,116 0,0 0,096 0,081 0,068 0,062 Fault loop reactance - X o Ph-PE (1) mω/m 0,086 0,086 0,081 0,061 0,067 0,035 0,051 0,046 0,046 Fault loop impedence - Z o Ph-PE (1) mω/m 0,176 0,176 0,144 0,131 0,120 0,2 0,096 0,082 0,077 cosϕ = 0,70 54,24 54,24 37,18 32,92 30,48 21,39 22,60 18,32 12,80 cosϕ = 0,75 55,52 55,52 38,04 33,65 31,14 21,48 22,78 18,47 13,09 Voltage drop - ΔV cosϕ = 0,80 56,57 56,57 38,75 34,25 31,66 21,45 22,84 18,51 13,32 with distributed load (1) cosϕ = 0,85 [V/m/A] -6 57,33 57,33 39,26 34,67 32,01 21,26 22,73 18,42 13,48 cosϕ = 0,90 57,64 57,64 39,46 34,81 32, 20,82 22,38 18,14 13,54 cosϕ = 0,95 57,14 57,14 39,09 34,44 31,71 19,93 21,58 17,48 13,40 cosϕ = 1 51,90 51,90 35,47 31,14 28,55 16,44 18,17 14,71 12,11 Weight - p Kg/m 24 24 35 40 46 56 61 85 118 Overall mm (LxH) 132x129 132x129 132x174 132x174 132x204 132x312 132x312 132x372 132x452 Fire load kwh/m 2,38 2,38 3,20 3,20 3,63 5,41 5,41 6,37 7,07 For each outlet point kwh 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 Joule effect losses at nominal current - P W/m 1 180 192 276 396 356 645 816 50 The nominal ratings is related to an ambient temperature of 50 C (55 C with class F insulation). K = 1 k = 1 K = 1-51 -

TECHICAL DATA (BAA) 3P + + FE + PE FE COPPER The technical data for each rating is obtained from the results of tests carried out according to IEC-E 61439-1&6 and shown in the LOVAG Certificates. o data are obtained from extrapolation. Cu * Tested (laboratory limit) ** Calculated A (50 C) 800 00 1250 1600 2000 2500 3200 4000 5000 ominal rating General Information Reference Standard IEC-E 61439-1 / IEC-E 61439-6 Rated Operational Voltage - U e V 00 Rated Insulation Voltage - U i V 00 Frequency Hz 50 Protection degree IP IP 55 - (on request IP66) Currents permitted Phase rated short-circuit withstand (1s) -I cw 50 50 80 80 90 93 120 * 120 * 120 * 144 ** 162 ** 167 ** Phase rated peak short-circuit withstand (1s) - I pk 1 1 176 176 198 205 264 * 264 * 264 * 316 ** 356 ** 367 ** Conductors Phase cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) eutral cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) Phase resistance R 20 mω/m 0,047 0,047 0,033 0,029 0,024 0,017 0,016 0,012 0,011 Phase reactance - X t mω/m 0,029 0,029 0,020 0,018 0,018 0,016 0,016 0,013 0,007 Phase impedence - Z t mω/m 0,067 0,067 0,046 0,040 0,037 0,025 0,027 0,022 0,016 (1) Phase resistance at thermal conditions - R t mω/m 0,060 0,060 0,041 0,037 0,033 0,019 0,021 0,017 0,014 Protection conductor (casing) Cross-section (Enclosure) mm 2 1.332 1.332 1.627 1.627 1.929 2.955 2.955 3.559 4.164 Cross-section (=Cu) (Enclosure) mm 2 799 799 976 976 1.7 1.773 1.773 2.165 2.498 Clean Earth (FE) Cross-section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) Others features Fault loop resistence - R o Ph-Ph (1) mω/m 0,161 0,161 0,114 0,1 0,091 0,062 0,073 0,054 0,042 Fault loop reactance - X o Ph-Ph (1) mω/m 0,094 0,094 0,077 0,077 0,064 0,042 0,046 0,035 0,029 Fault loop impedence - Z o Ph-Ph (1) mω/m 0,186 0,186 0,137 0,134 0,117 0,075 0,087 0,065 0,051 Fault loop resistence - R o Ph-PE (1) mω/m 0,4 0,4 0,119 0,116 0,0 0,096 0,081 0,068 0,062 Fault loop reactance - X o Ph-PE (1) mω/m 0,086 0,086 0,081 0,061 0,067 0,035 0,051 0,046 0,046 Fault loop impedence - Z o Ph-PE (1) mω/m 0,176 0,176 0,144 0,131 0,120 0,2 0,096 0,082 0,077 cosϕ = 0,70 54,24 54,24 37,18 32,92 30,48 21,39 22,60 18,32 12,80 cosϕ = 0,75 55,52 55,52 38,04 33,65 31,14 21,48 22,78 18,47 13,09 Voltage drop - ΔV cosϕ = 0,80 56,57 56,57 38,75 34,25 31,66 21,45 22,84 18,51 13,32 with distributed load (1) cosϕ = 0,85 [V/m/A] -6 57,33 57,33 39,26 34,67 32,01 21,26 22,73 18,42 13,48 cosϕ = 0,90 57,64 57,64 39,46 34,81 32, 20,82 22,38 18,14 13,54 cosϕ = 0,95 57,14 57,14 39,09 34,44 31,71 19,93 21,58 17,48 13,40 cosϕ = 1 51,90 51,90 35,47 31,14 28,55 16,44 18,17 14,71 12,11 Weight - p Kg/m 28 28 42 47 55 71 76 6 148 Overall mm (LxH) 4x129 4x129 4x174 4x174 4x204 4x312 4x312 4x372 4x452 Fire load kwh/m 2,38 2,38 3,20 3,20 3,63 5,41 5,41 6,37 7,07 For each outlet point kwh 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 Joule effect losses at nominal current - P W/m 1 180 192 276 396 356 645 816 50 The nominal ratings is related to an ambient temperature of 50 C (55 C with class F insulation). K = 1 k = 1 K = 1-52 -

TECHICAL DATA COPPER (GAA) Fe/2 The technical data for each rating is obtained from the results of tests carried out according to IEC-E 61439-1&6 and shown in the LOVAG Certificates. o data are obtained from extrapolation. 3P + + FE/2 + PE Cu * Tested (laboratory limit) ** Calculated A (50 C) 800 00 1250 1600 2000 2500 3200 4000 5000 ominal rating General Information Reference Standard IEC-E 61439-1 / IEC-E 61439-6 Rated Operational Voltage - U e V 00 Rated Insulation Voltage - U i V 00 Frequency Hz 50 Protection degree IP IP 55 - (on request IP66) Currents permitted Phase rated short-circuit withstand (1s) -I cw 50 50 80 80 90 93 120 * 120 * 120 * 144 ** 162 ** 167 ** Phase rated peak short-circuit withstand (1s) - I pk 1 1 176 176 198 205 264 * 264 * 264 * 316 ** 356 ** 367 ** Conductors Phase cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) eutral cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) Phase resistance R 20 mω/m 0,047 0,047 0,033 0,029 0,024 0,017 0,016 0,012 0,011 Phase reactance - X t mω/m 0,029 0,029 0,020 0,018 0,018 0,016 0,016 0,013 0,007 Phase impedence - Z t mω/m 0,067 0,067 0,046 0,040 0,037 0,025 0,027 0,022 0,016 (1) Phase resistance at thermal conditions - R t mω/m 0,060 0,060 0,041 0,037 0,033 0,019 0,021 0,017 0,014 Protection conductor (casing) Cross-section (Enclosure) mm 2 1.332 1.332 1.627 1.627 1.929 2.955 2.955 3.559 4.164 Cross-section (=Cu) (Enclosure) mm 2 799 799 976 976 1.7 1.773 1.773 2.165 2.498 Clean Earth (FE) Cross-section % ph 50 50 50 50 50 50 50 50 50 Others features Fault loop resistence - R o Ph-Ph (1) mω/m 0,161 0,161 0,114 0,1 0,091 0,062 0,073 0,054 0,042 Fault loop reactance - X o Ph-Ph (1) mω/m 0,094 0,094 0,077 0,077 0,064 0,042 0,046 0,035 0,029 Fault loop impedence - Z o Ph-Ph (1) mω/m 0,186 0,186 0,137 0,134 0,117 0,075 0,087 0,065 0,051 Fault loop resistence - R o Ph-PE (1) mω/m 0,4 0,4 0,119 0,116 0,0 0,096 0,081 0,068 0,062 Fault loop reactance - X o Ph-PE (1) mω/m 0,086 0,086 0,081 0,061 0,067 0,035 0,051 0,046 0,046 Fault loop impedence - Z o Ph-PE (1) mω/m 0,176 0,176 0,144 0,131 0,120 0,2 0,096 0,082 0,077 cosϕ = 0,70 54,24 54,24 37,18 32,92 30,48 21,39 22,60 18,32 12,80 cosϕ = 0,75 55,52 55,52 38,04 33,65 31,14 21,48 22,78 18,47 13,09 Voltage drop - ΔV cosϕ = 0,80 56,57 56,57 38,75 34,25 31,66 21,45 22,84 18,51 13,32 with distributed load (1) cosϕ = 0,85 [V/m/A] -6 57,33 57,33 39,26 34,67 32,01 21,26 22,73 18,42 13,48 cosϕ = 0,90 57,64 57,64 39,46 34,81 32, 20,82 22,38 18,14 13,54 cosϕ = 0,95 57,14 57,14 39,09 34,44 31,71 19,93 21,58 17,48 13,40 cosϕ = 1 51,90 51,90 35,47 31,14 28,55 16,44 18,17 14,71 12,11 Weight - p Kg/m 28 28 39 44 51 67 72 0 138 Overall mm (LxH) 4x129 4x129 4x174 4x174 4x204 4x312 4x312 4x372 4x452 Fire load kwh/m 2,38 2,38 3,20 3,20 3,63 5,41 5,41 6,37 7,07 For each outlet point kwh 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 Joule effect losses at nominal current - P W/m 1 180 192 276 396 356 645 816 50 The nominal ratings is related to an ambient temperature of 50 C (55 C with class F insulation). K = 1 k = 1 K = 1-53 -

TECHICAL DATA (DAA) 3P + 2 + PE Cu 2 COPPER The technical data for each rating is obtained from the results of tests carried out according to IEC-E 61439-1&6 and shown in the LOVAG Certificates. o data are obtained from extrapolation. * Tested (laboratory limit) ** Calculated A (50 C) 800 00 1250 1600 2000 2500 3200 4000 5000 ominal rating General Information Reference Standard IEC-E 61439-1 / IEC-E 61439-6 Rated Operational Voltage - U e V 00 Rated Insulation Voltage - U i V 00 Frequency Hz 50 Protection degree IP IP 55 - (on request IP66) Currents permitted Phase rated short-circuit withstand (1s) -I cw 50 50 80 80 90 93 120 * 120 * 120 * 144 ** 162 ** 167 ** Phase rated peak short-circuit withstand (1s) - I pk 1 1 176 176 198 205 264 * 264 * 264 * 316 ** 356 ** 367 ** Conductors Phase cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) eutral cross section mm x mm (5,3x85) (5,3x85) (5,2x130) (6,3x130) (6,3x160) (2x5,5x130) (2x5,8x130) (2x6,3x160) (2x6,5x200) Phase resistance R 20 mω/m 0,047 0,047 0,033 0,029 0,024 0,017 0,016 0,012 0,011 Phase reactance - X t mω/m 0,029 0,029 0,020 0,018 0,018 0,016 0,016 0,013 0,007 Phase impedence - Z t mω/m 0,067 0,067 0,046 0,040 0,037 0,025 0,027 0,022 0,016 (1) Phase resistance at thermal conditions - R t mω/m 0,060 0,060 0,041 0,037 0,033 0,019 0,021 0,017 0,014 Protection conductor (casing) Cross-section (Enclosure) mm 2 1.332 1.332 1.627 1.627 1.929 2.955 2.955 3.559 4.164 Cross-section (=Cu) (Enclosure) mm 2 799 799 976 976 1.7 1.773 1.773 2.135 2.498 Others features Fault loop resistence - R o Ph-Ph (1) mω/m 0,161 0,161 0,114 0,1 0,091 0,062 0,073 0,054 0,042 Fault loop reactance - X o Ph-Ph (1) mω/m 0,094 0,094 0,077 0,077 0,064 0,042 0,046 0,035 0,029 Fault loop impedence - Z o Ph-Ph (1) mω/m 0,186 0,186 0,137 0,134 0,117 0,075 0,087 0,065 0,051 Fault loop resistence - R o Ph-PE (1) mω/m 0,4 0,4 0,119 0,116 0,0 0,096 0,081 0,068 0,062 Fault loop reactance - X o Ph-PE (1) mω/m 0,086 0,086 0,081 0,061 0,067 0,035 0,051 0,046 0,046 Fault loop impedence - Z o Ph-PE (1) mω/m 0,176 0,176 0,144 0,131 0,120 0,2 0,096 0,082 0,077 cosϕ = 0,70 54,24 54,24 37,18 32,92 30,48 21,39 22,60 18,32 12,80 cosϕ = 0,75 55,52 55,52 38,04 33,65 31,14 21,48 22,78 18,47 13,09 Voltage drop - ΔV cosϕ = 0,80 56,57 56,57 38,75 34,25 31,66 21,45 22,84 18,51 13,32 with distributed load (1) cosϕ = 0,85 [V/m/A] -6 57,33 57,33 39,26 34,67 32,01 21,26 22,73 18,42 13,48 cosϕ = 0,90 57,64 57,64 39,46 34,81 32, 20,82 22,38 18,14 13,54 cosϕ = 0,95 57,14 57,14 39,09 34,44 31,71 19,93 21,58 17,48 13,40 cosϕ = 1 51,90 51,90 35,47 31,14 28,55 16,44 18,17 14,71 12,11 Weight - p Kg/m 28 28 42 47 55 71 76 6 148 Overall mm (LxH) 4x129 4x129 4x174 4x174 4x204 4x312 4x312 4x372 4x452 Fire load kwh/m 2,38 2,38 3,20 3,20 3,63 5,41 5,41 6,37 7,07 For each outlet point kwh 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 1,05 Joule effect losses at nominal current - P W/m 1 180 192 276 396 356 645 816 50 The nominal ratings is related to an ambient temperature of 50 C (55 C with class F insulation). K = 1 k = 1 K = 1-54 -

ISTALLATIO ISTRUCTIOS STRAIGHT TRUKIG A Insert the two units respecting the neutral position mechanical device [1]. OK 1 1 O 30 mm OK B Check the units alignment and assembling the joint cover [2] assuring the correct coupling [3]. 2 3 click! 2 B 1 For vertical runs: Before proceed with the monoblock tighting (point C) fix the unit with the fixing unit [3]. 3 2-55 -

ISTALLATIO ISTRUCTIOS STRAIGHT TRUKIG C Tighten the monoblock [4] using the bolt/s until it/they automatically shear [5] when the nominal torque moment will be achieved ( ~ 85 m). 5 Maintenance-free monoblock 4 D Assembling the side cover [6]. First connect it to the the busbar joint from the bottom [7]; then turn the cover and fix it on pushing in by pressure [8]. 8 8 6 7 6 E Check that the covers are correctly assembled. Tighten the srews (9) and then insert the side cap(). click! 9 x4 x4 single bar x8 double bar - 56 -

MEIM - 01/ MIDDLE EAST www.megabarre.com MEGABARRE - ID. DE EQUIP. ELÉTRICOS LTDA Rua José Medeiros da Costa, 201 Jundiaì - SP Brasil - CEP 13212-173 Tel. +55 11 20 1616 Fax +55 11 2019 7888 megabarre@megabarre.com.br MEGABARRE EUROPE S.r.l. Via Luigi Einaudi 18/24 25030 Torbole Casaglia Brescia - Italy Tel. +39 030 29711 Fax +39 030 29777 info@megabarre.com MEGABARRE - ID. DE EQUIP. ELÉTRICOS CHILE LTDA Camino Lo Boza, 360 Galpon A Pudahuel Santiago - Chile Tel. +56 2 949 3912 Fax +56 2 949 3885 rhermosilla@megabarre.cl