LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Similar documents
LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Characteristics 5 TeSys k contactors and reversing contactors

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Motor starters. TeSys E. Designed for the essential

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

NS..S contactor relays - with spring terminals AC operated

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

3 - Protection components Circuit-breakers

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

RENF22R2MMW Zelio Timer Relay - Modular

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Components for safety applications

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Protection components

Electromechanical pressure and vacuum switches 0

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Protection components

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

Zelio Control Measurement Relays

References 1 for asynchronous motors 1

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

38 Series - Relay interface modules A. Features /

48 Series - Relay interface modules A. Features

Pendant control stations 6

Pendant control stations 6

Zelio Plug-In Relays. RXG interface relays. Catalog

Type: DILEM 10 G(24VDC) Article No.:

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Type: DILM40(RDC24) Article No.:

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type CP-S, CP-C & CP-A Switch mode

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Complete units: Mushroom heads ø 22mm

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Control Stations ø 22

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Transcription:

Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Power pole contact composition [Ue] rated operational voltage [Ie] rated operational current Motor power kw Motor power HP (UL / CSA) Control circuit type [Uc] control circuit voltage Auxiliary contact composition Oct 17, 2018 TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC for power circuit <= 690 V AC 25...400 Hz for power circuit 25 A (<= 60 C) at <= 440 V AC AC-3 for power circuit 40 A (<= 60 C) at <= 440 V AC AC-1 for power circuit 11 kw at 380...400 V AC 50/60 Hz AC-3 15 kw at 500 V AC 50/60 Hz AC-3 15 kw at 660...690 V AC 50/60 Hz AC-3 5.5 kw at 220...230 V AC 50/60 Hz AC-3 11 kw at 415...440 V AC 50/60 Hz AC-3 5.5 kw at 400 V AC 50/60 Hz AC-4 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors DC low consumption 24 V DC 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947 Overvoltage category III 1 Disclaimer: This documentation is not inted as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[Ith] conventional free air thermal current 40 A at <= 60 C for power circuit 10 A at <= 60 C for signalling circuit Irms rated making capacity 450 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Safety cover Mounting support 120 A <= 40 C 1 min power circuit 240 A <= 40 C 10 s power circuit 380 A <= 40 C 1 s power circuit 50 A <= 40 C 10 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 40 A gg at <= 690 V coordination type 2 for power circuit 63 A gg at <= 690 V coordination type 1 for power circuit 10 A gg for signalling circuit conforming to IEC 60947-5-1 2 mohm at 50 Hz - Ith 40 A for power circuit 600 V for power circuit certifications CSA 600 V for power circuit certifications UL 690 V for power circuit conforming to IEC 60947-4-1 690 V for signalling circuit conforming to IEC 60947-1 600 V for signalling circuit certifications CSA 600 V for signalling circuit certifications UL 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V 3.2 W AC-1 1.25 W AC-3 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals Tightening torque Operating time BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable Power circuit : screw clamp terminals 1 cable(s) 1.5...10 mm² - cable stiffness: solid - without cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable Power circuit : screw clamp terminals 1 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable Power circuit : screw clamp terminals 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable Power circuit : screw clamp terminals 1 cable(s) 1...10 mm² - cable stiffness: flexible - with cable Power circuit : screw clamp terminals 2 cable(s) 1.5...6 mm² - cable stiffness: flexible - with cable Power circuit : screw clamp terminals 2 cable(s) 2.5...10 mm² - cable stiffness: solid - without cable Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit : 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit : 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 65.45...88.55 ms closing 2

20...30 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability 30 Mcycles Operating rate <= 3600 cyc/h at <= 60 C Complementary Coil technology Control circuit voltage limits Time constant Built-in bidirectional peak limiting diode suppressor 0.1...0.3 Uc drop-out at 60 C, DC 0.8...1.25 Uc operational at 60 C, DC 40 ms Inrush power in W 2.4 W at 20 C Hold-in power consumption in W 2.4 W at 20 C Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma for signalling circuit 17 V for signalling circuit 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact > 10 MOhm for signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation -5...60 C Ambient air temperature for storage -60...80 C Permissible ambient air temperature around the device Operating altitude -40...70 C at Uc 3000 m without derating in temperature Fire resistance 850 C conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor closed 15 Gn for 11 ms Shocks contactor open 8 Gn for 11 ms 85 mm 45 mm 101 mm 0.53 kg Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product of life instructions Green Premium product Compliant - since 0721 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product environmental Available End of life manual 3

Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D25BL Dimensions (1) Minimum electrical clearance LC1 D25 D38 D183 D323 b 85 99 c without cover or add-on blocks 99 99 with cover, without addon blocks 101 101 c1 with LAD N or C (2 or 4 contacts) 132 132 c2 with LA6 DK10 144 144 c3 with LAD T, R, S 152 152 with LAD T, R, S and sealing cover 156 156 5

Product data sheet Connections and Schema LC1D25BL Wiring 6