Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

Similar documents
BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

, ,54 A

148 Electric Machines

86 chapter 2 Transformers

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

In Class Examples (ICE)

Spring 2000 EE361: MIDTERM EXAM 1

Code No: R Set No. 1

Code No: R Set No. 1

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

EN Assignment No.1 - TRANSFORMERS

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Impact Assessment Generator Form

PROBLEMS on Transformers

Fatima Michael college of Engineering and Technology

Chapter 2: Transformers

Chapter 2-1 Transformers

Hours / 100 Marks Seat No.

SAMPLE EXAM PROBLEM PROTECTION (6 OF 80 PROBLEMS)

Question Paper Profile

ELECTRICAL POWER TRANSMISSION TRAINER

VALLIAMMAI ENGINEERING COLLEGE

Conventional Paper-II-2011 Part-1A

Practical Transformer on Load

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK UNIT I BASIC CIRCUITS ANALYSIS PART A (2-MARKS)

Conventional Paper-II-2013

SYNCHRONOUS MACHINES

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. MIDTERM EXAMINATION, February Forth Year Electrical and Computer Engineering

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

PAPER-II (Subjective)

Hours / 100 Marks Seat No.

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

CONTENTS. 1. Introduction Generating Stations 9 40

TABLE OF CONTENT

Embedded Generation Connection Application Form

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

CHAPTER 11. Balanced Three-Phase Circuits

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Connection Impact Assessment Application Form

2015 ELECTRICAL SCIENCE

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

Transformer & Induction M/C

The power transformer

Downloaded From All JNTU World

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Downloaded from / 1

PROBLEMS. Figure13.74 For Prob Figure13.72 For Prob Figure13.75 For Prob Figure13.73 For Prob Figure13.76 For Prob

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

IGEE 402 Power System Analysis. FINAL EXAMINATION Fall 2004

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad


TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Transmission Line Models Part 1

Chapter # : 17 Symmetrical Fault Calculations

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

El-Hawary, M.E. The Transformer Electrical Energy Systems. Series Ed. Leo Grigsby Boca Raton: CRC Press LLC, 2000

COURSE PLANNER SUBJECT: ELECTRICAL POWER SYSTEM II

AC Power Instructor Notes

CHAPTER 2. Transformers. Dr Gamal Sowilam

QUESTION BANK ETE (17331) CM/IF. Chapter1: DC Circuits

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Exercises on overhead power lines (and underground cables)

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian institute of Technology, Kharagpur

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

EE2022 Electrical Energy Systems

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Initial Application Form for Connection of Distributed Generation (>10kW)

Embedded Generation Connection Application Form

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Sample Question Paper

IV. Three-Phase Transfomers

VALLIAMMAI ENGINEERING COLLEGE

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Embedded Generation Connection Application Form

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

ELECTRICAL ENGINEERING ESE TOPIC WISE OBJECTIVE SOLVED PAPER-II

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

ELECTRICAL POWER ENGINEERING

Form B. Connection Impact Assessment Application Form Distribution System

Power Factor & Harmonics

Downloaded From JNTU World. B.Tech II Year II Semester (R09) Supplementary Examinations December/January 2014/2015 GENERATION OF ELECTRIC POWER

% the leading currents. I(1,:) = amps.* ( j*0.6); % Lagging I(2,:) = amps.* ( 1.0 ); % Unity I(3,:) = amps.* ( j*0.

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Ferroresonance Conditions Associated With a 13 kv Voltage Regulator During Back-feed Conditions

Beskrivelse av simuleringsmodell ==> Description of simulation model

Generator Protection GENERATOR CONTROL AND PROTECTION

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

University of Rajshahi Department of Electrical & Electronic Engineering B.Sc. Engineering Part-IV Odd Semester Examination- 2017

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

3. (a) List out the advantages and disadvantages of HRC fuse (b) Explain fuse Characteristics in detail. [8+8]

The Advantages and Application of Three Winding Transformers

EE Branch GATE Paper 2001 SECTION A (TOTAL MARKS = 75)

Transcription:

Cork Institute of Technology Bachelor of Science (Honours) in Electrical Power Systems - Award Instructions Answer FIVE questions. (EELPS_8_Y4) Autumn 2008 Electrical Energy Systems (Time: 3 Hours) Examiners: Mr. S. Boljevic Mr. M. Hennessy Prof. E. McQuade Q1. (a) A 3 phase 4 wire 400V system supplies three star connected loads. 0 Z = 10 0 Ω, 15 30 0 0 Z = Ω, Z = 10 30 Ω A B The phase sequence is ABC. Neatly sketch the system described above clearly showing each label and calculate (i) line currents (ii) neutral currents (iii) total active power consumed by the system. C A 3 phase balance delta connected load of (15 + j5) Ω in each phase is fed from a 400V 3 phase system. The phase sequence is ABC. Neatly sketch the system described above, clearly showing each label and calculate: (i) magnitude of phase currents (ii) magnitude of line currents (iii) total active power consumed by the system (v) total reactive power consumed by the system (vi) total apparent power consumed by the system (vii) power factor of the system.

Q2. (a) A generator supplies a load through a feeder whose impedance Z foh = 1 + j2ω. The voltage across the load is 230V. Sketch the circuit and calculate: (i) the real power supplied by generator (ii) the reactive power supplied by generator (iii) draw the phasor diagram of the circuit [Note: Take the load voltage as the reference phasor] Two voltage sources V 1 = 240 5V and V 2 = 220 0 V are connected by a short line of impedance. Z = 2 + j7 Ω as shown in Fig 1. Determine the real and reactive power supplied or received by each source and the power loss in the line. R jx V 1 V 2 2

Q3. (a) Outline and explain the factors that govern the terminal voltage of an alternator when the load changes. Why is the knowledge of voltage regulation of an alternator important? A 3-phase, 50 H Z star-connected 1000 kva, 2300V alternator gives a short-circuit current of 400A for a certain field excitation. With the same excitation, the open-circuit voltage was 1328V (phase value). The d.c. resistance between two lines is 0.412 Ω. Calculate: (i) effective armature resistance (ii) synchronous reactance (iii) the full-load voltage regulation at 0.8 p.f. lagging. Q4. (a) A 3300/400V, 10 kva transformer has primary and secondary winding resistance of 13Ω and 0.15 Ω respectively. The leakage reactance referred to primary is 45Ω. The magnetising impedance referred to primary is 6kΩ and the resistance corresponding to the core loss is 12kΩ. Determine the input current: (i) when the secondary terminals are open-circuited (ii) when the secondary load current is 25A at a power factor of 0.8 lagging. Use simplified equivalent circuit. (i) (ii) The primary and secondary windings of a 40 kva, 6600/250 V single-phase transformer have resistance of 10Ω and 0.2Ω respectively. The leakage reactance of the transformer referred to the primary is 35Ω. Calculate: the primary voltage required to circulate full-load current when the secondary is shortcircuited. the full-load regulation at 0.8 p.f. lagging. NEGLECT the no-load current 3

Q5. (a) Explain how transmission lines are classified into short, medium and long lines and explain their characteristics. A 25km 3 phase overhead line delivers 8 MW at 11kV at 0.85 lagging p.f. line loss is 12% of power delivered. Line inductance is 1.1mH per km per phase. Calculate: (i) sending-end voltage (ii) voltage regulation A 3-phase transmission line delivers a load of 5MW at 0.8p.f. lagging. Resistance of each conductor is 0.5 km Ω. Receiving-end voltage is 33kV. If the line loss is not to exceed 10Y, determine the length of the line. Q6. (a) Describe with aid of a neat sketch off-load and on-load tap changing transformer method of voltage control. What are the limitations of each method? A 3-phase overhead line has resistance and reactance per phase 6 Ω and 22Ω respectively. The load at the receiving end is 20MW at 33kV and a power factor of 0.85 lagging. Find the capacity of the synchronous condenser required for this load condition if it is connected at the receiving end and the line voltages at both ends are maintained at 33kV. 4

Q7. (a) Outline and explain steps for symmetrical fault calculations. What do you understand by percentage reactance? Why do we prefer to express the reactance of various elements in percentage values for short-circuit calculations? A 3-phase transmission line operating at 10kV and having a resistance of 1Ω and reactance of 5Ω is connected to the generating station bus-bars through 10MVA step-up transformer having a reactance of 5%. The bus-bars are supplied by a 10MVA alternator having 10% reactance. Calculate the short-circuit kva fed to symmetrical fault between phases if it occurs (i) at the load end of transmission line (ii) at the high voltage terminals of the transformer 10MVA 10% 10MVA 5% F 1 1Ω 5Ω F 2 10kv LOAD 5