Grid Code Review Panel. Information Required to Evaluate Subsynchrononous Resonance on the Transmission System

Similar documents
GSR018: Sub-Synchronous Oscillations (SSO) Workgroup Report

DATA REGISTRATION CODE (DRC) CONTENTS. (This contents page does not form part of the Grid Code)

GSR018/GC0077: Sub-Synchronous Oscillations (SSO)

DATA REGISTRATION CODE CONTENTS. (This contents page does not form part of the Grid Code) DRC.1 INTRODUCTION... 1 DRC.2 OBJECTIVE...

SSE Offices, Glasgow and Teleconference

Revision 1 of Issue 4 of the Grid Code has been approved by the Authority for implementation on 10 th February 2010.

each time the Frequency is above 51Hz. Continuous operation is required

INITIAL RfG FREQUENCY PARAMETER SELECTION. BASED ON DRAFT RfG VALUES. Requirement Range Suggested GB Value Comments

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

EUROPEAN CONNECTION CONDITIONS (ECC) CONTENTS. (This contents page does not form part of the Grid Code)

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

Key DRAFT EUROPEAN CONNECTION CONDITIONS LEGAL TEXT DATED 13/12/17

Protection for Sub SSTI Conditions Using an Industrial Sub-harmonic Relay

WORKING GROUP REPORT. Data Exchange Working Group. Prepared by the Data Exchange Working Group for submission to the Grid Code Review Panel

Deleted: 9 4 anuary ... [1] Deleted: much more. Formatted ... [2] Formatted Table. Formatted: Indent: Left: 0.06 cm

Revision 24 of Issue 3 of the Grid Code has been approved by the Authority for implementation on 19 th November 2007.

DATA REGISTRATION CODE SCHEDULE 1 Page 2 of 15 GENERATING UNIT (OR CCGT MODULE) TECHNICAL DATA POWER STATION NAME: DATA to RTL CUSC Cont ract

Revision 32 of Issue 3 of the Grid Code has been approved by the Authority for implementation on 8 th December 2008.

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Constant Terminal Voltage. Working Group 1 29 st January 2014

Annex 2 - Proposed Grid Code Legal Text

TABLE 1 COMPARISION OF ENTSO-E RfG TO GB GRID CODE

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

OPERATING CODE NO. 5 (OC5)

A Comprehensive Approach for Sub-Synchronous Resonance Screening Analysis Using Frequency scanning Technique

Beskrivelse av simuleringsmodell ==> Description of simulation model

Energy Networks Association

ENTSO-E Draft Network Code on High Voltage Direct Current Connections and DCconnected

ELEMENTS OF FACTS CONTROLLERS

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

ABB Inc. April 1, 2016 Slide 1

Study of Subsynchronous Resonance in Power Systems

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

A New Subsynchronous Oscillation (SSO) Relay for Renewable Generation and Series Compensated Transmission Systems

Generation Interconnection Study Data Sheet Synchronous Machines

High Wind Speed Shutdown / Power Available

Network Code for HVDC Connections and DC-connected Power Park Modules Requirement Outlines

WORKING GROUP REPORT. Frequency and voltage operating range. Prepared by the Working Group for submission to the Grid Code Review Panel

Requirements for Generators European Network Code High Level Implementation Issues

Power System Stability. Course Notes PART-1

Grid Impact of Neutral Blocking for GIC Protection:

Appendix D Fault Levels

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Form B. Connection Impact Assessment Application Form Distribution System

UNDERSTANDING SUB-HARMONICS

NETS SQSS Modification Proposal

QUESTIONNAIRE for Wind Farm Power Stations only

Indication of Dynamic Model Validation Process

Mandatory Frequency Response

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

System Protection and Control Subcommittee

A NEW MONITORING SPECTRAL TECHNIQUE FOR SUB- SYNCHRONOUS ELECTRICAL TORQUE FREQUENCIES

C1-207 TRANSMISSION CAPACITY INCREASE BY RETURNING POWER SYSTEM STABILIZERS

ESB National Grid Transmission Planning Criteria

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

POWER SYSTEM OSCILLATIONS

Damping of Sub synchronous Resonance Using SSSC Based PWM Hysteresis Controller

Fundamental Concepts of Dynamic Reactive Compensation. Outline

Initial Application Form for Connection of Distributed Generation (>10kW)

Mitigation & Protection of Sub-Synchronous Controller Interactions (SSCI) in DFIG Wind Turbine Systems

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

Sizing Generators for Leading Power Factor

Planners Perspective on Series Compensated Transmission Lines

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/

How Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements

FREQUENCY and VOLTAGE, ranges and durations

EE 742 Chapter 9: Frequency Stability and Control. Fall 2011

GENERATOR DATA JANUARY 30, 2015

System Operability Framework 2014

EASTERN AFRICA POWER POOL

Connection Impact Assessment Application Form

Overview. The Principles of Power System Operation module presents the following topics:

Fault Ride Through Principles. and. Grid Code Proposed Changes

RELEVANT ELECTRICAL STANDARDS

Dynamic Phasors for Small Signal Stability Analysis

GB FREQUENCY HVDC FREQUENCY RESPONSE PARAMTERS HVDC CONNECTIONS (TITLE II)

ELECTRICITY ASSOCIATION SERVICES LIMITED 2001

RELEVANT ELECTRICAL STANDARDS

SYNCHRONISING AND VOLTAGE SELECTION

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

Eigenvalue Analysis All Information on Power System Oscillation Behavior Rapidly Analyzed

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Spec Information. Reactances Per Unit Ohms

TS RES - OUTSTANDING ISSUES

Standard BAL-005-0b Automatic Generation Control

SUBSYNCHRONOUS TORSIONAL OSCILLATIONS AND RESONANCE MITIGATION IN HVDC SYSTEM AND STATCOM COMBINATION

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Fault Ride Through Technical Assessment Report Template

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

THE GRID CODE OC7.5 INTEGRAL EQUIPMENT TESTS

Transcription:

Grid Code Review Panel Information Required to Evaluate Subsynchrononous Resonance on the Transmission System Summary of Issue A paper by National Grid Contact: Graham Stein 1. All electrical and electromechanical power systems have resonant oscillatory modes at a range of frequencies. These resonances can be excited by disturbances to a system, including routine switching events. Most oscillations are harmless and short lived because of the effective damping inherent in a system. However, under exceptional circumstances an oscillation can grow and be maintained at a sufficient magnitude, and for a sufficient period of time, to cause plant damage or system instability. 2. The rotating shaft system of a turbine generating unit has inherent torsional oscillation frequencies which are determined by its large inertia masses and the interconnected shaft system. If the associated frequencies reflected at the terminals of the generator are close to characteristic frequencies of the connected electrical power system and is insufficiently damped, there will be unfavourable interaction between the two systems. The problem generally lies in the sub-synchronous frequency range (frequencies below 50Hz) as those at the super-synchronous range are well-damped. 3. The high speed active controls deployed in a number of power system technologies, including High Voltage Direct Current (HVDC) equipment, have the potential to exacerbate sub-synchronous oscillations (by providing negative damping). Equally, if explicitly designed to do so, they can provide positive damping and mitigate any risks of adverse oscillatory effects occurring. In order to do so effectively, it can be necessary to evaluate the frequency dependent characteristic of all local power system components, including the mechanical shaft system of synchronous generating units. 4. Changes to the electricity network configurations change the resonant modes of the overall power system. Series compensation has a significant impact on these characteristics and has been identified as a key tool in maximising the transfer capability of the current overhead line network across Great Britain. 5. The application of HVDC technology to the transmission system will grow significantly over the next few years alongside the deployment of series compensation solutions. There is therefore now a need to consider subsynchronous resonance on a regular and ongoing basis. 6. The Grid Code does not specifically provide for the information exchange required in order to assess sub-synchronous resonance fully. National Grid has recently requested this information from a number of users under the provisions of PC.A.7 which allow for additional data to be requested. The information is required in order to assess the risk of sub-synchronous resonance phenomenon over a range of future system configurations and if necessary to develop control system solutions to mitigate these. Page 1 of 5

7. Given that there is a need to consider sub-synchronous resonance issues on an ongoing basis, there is a need to specify the information required from Generators clearly within the Grid Code such that generating companies can obtain this from manufacturers at an appropriate stage. There would also be a benefit in specifying what might be asked of an existing Generator should local system changes result in the need to evaluate or re-evaluate sub-synchronous resonance issues. Current Provisions 8. The obligation to manage sub-synchronous resonance stems from National Grid's obligation to facilitate access to the transmission system safely and securely, with a specific obligation under the SQSS to avoid system instability. 9. As highlighted above, HVDC equipment can exacerbate sub-synchronous resonance. Hence, the Grid Code places a requirement on transmission users who own DC Convertors not to cause a sub-synchronous resonance problem and to provide damping control facilities in CC.6.3.16 (a). 10. First pass studies of the electrical system can show whether there may be a likelihood of a sub-synchronous frequency that could affect one of more generators. However, in order to fulfil the obligations of CC.6.3.16 (a), it can be necessary to cater for the combined effects of the detailed mechanical shaft systems together with the electrical parameters of the generating units and the connected electrical power system. 11. There is no specific provision within the Grid Code which sets out the information needed to represent the relevant mechanical components of generators. 12. PC.A.7 does however provide for National Grid to request additional data where meaningful studies cannot be performed by the relevant parties using the data submitted under current specific provisions. 13. The relevant existing Grid Code drafting is shown in Attachment 1. Proposed New Provisions 14. It is proposed that new provisions should be incorporated into the Grid Code to specify the information required from synchronous generators to allow subsynchronous resonance to be assessed. These would comprise a new paragraph in PC.A.5.3.2 and a complementary entry in the DRC, Schedule 1 with the information classified as. 15. The additional data items required to represent the turbine-generator shaft model for each synchronous generating unit are detailed in the draft text in Attachment 2. GCRP Recommendation 16. National Grid intends to bring forward a consultation setting out the modifications required to the Grid Code to enable the information exchange required to facilitate the future assessment of sub-synchronous resonance. The Panel are invited to raise any additional issues for consideration. Page 2 of 5

Attachment 1 Current Grid Code Text relevant to sub-synchronous resonance Additional Damping Control Facilities for DC Converters CC.6.3.16 (a) DC Converter owners, or Generators in respect of OTSDUW DC Converters or Network Operators in the case of an Embedded DC Converter Station not subject to a Bilateral Agreement must ensure that any of their Onshore DC Converters or OTSDUW DC Converters will not cause a subsynchronous resonance problem on the Total System. Each DC Converter or OTSDUW DC Converter is required to be provided with sub-synchronous resonance damping control facilities. PC.A.7 ADDITIONAL DATA FOR NEW TYPES OF POWER STATIONS, DC CONVERTER STATIONS, OTSUA AND CONFIGURATIONS Notwithstanding the Standard Planning Data and Detailed Planning Data set out in this Appendix, as new types of configurations and operating arrangements of Power Stations, DC Converter Stations and OTSUA emerge in future, NGET may reasonably require additional data to represent correctly the performance of such Plant and Apparatus on the System, where the present data submissions would prove insufficient for the purpose of producing meaningful System studies for the relevant parties. Page 3 of 5

Attachment 2 Proposed Draft Text (New Text in Red) PC.A.5.3 PC.A.5.3.1 PC.A.5.3.2 Synchronous Generating Unit and Associated Control System Data The data submitted below are not intended to constrain any Ancillary Services Agreement The following Synchronous Generating Unit and Power Station data should be supplied: (g) Generating Unit Mechanical Parameters It is occasionally necessary for NGET to assess the possible interaction between NETS and User's Systems including the torsional characteristic of the rotating components of Generating Units. For Generating Units with a Completion Date after dd mmm yyyy, and the following data items should be supplied: The number of turbine generator masses Inertia for each turbine generator mass (kgm 2 ) Stiffness constants between each turbine generator mass (Nm/rad) Number of poles Relative power applied to different parts of the turbine Mechanical mode frequencies (Hz) Modal damping decrement factors for the different mechanical modes Page 4 of 5

DRC Schedule 1 DATA DESCRIPTION TIME CONSTANTS (Short-circuit and Unsaturated) UNITS DATA to RTL CUSC Contr act CUSC App. Form DATA CAT. Direct axis transient time constant S DPD I Direct axis sub-transient time constant S DPD I Quadrature axis sub-transient time constant S DPD I Stator time constant S DPD I GENERATING UNIT OR STATION DATA G1 G2 G3 G4 G5 G6 STN MECHANICAL PARAMETERS The number of turbine generator masses Inertia for each turbine generator mass Stiffness constants between each turbine generator mass Kgm 2 Nm/rad Number of poles Relative power applied to different parts of the turbine % Mechanical mode frequencies Modal damping decrement factors for the different mechanical modes Hz GENERATING UNIT STEP-UP TRANSFORMER Rated MVA (PC.A.3.3.1 & PC.A.5.3.2) MVA SPD+ Voltage Ratio (PC.A.5.3.2) - DPD I Positive sequence reactance: (PC.A.5.3.2) Max tap % on MVA SPD+ Min tap % on MVA SPD+ Nominal tap % on MVA SPD+ Positive sequence resistance: (PC.A.5.3.2) Max tap % on MVA Min tap % on MVA Nominal tap % on MVA Zero phase sequence reactance (PC.A.5.3.2) % on MVA Tap change range (PC.A.5.3.2) +% / -% Tap change step size (PC.A.5.3.2) % Tap changer type: on-load or off-circuit (PC.A.5.3.2) On/Off Page 5 of 5