Load Cells Page Option Option

Similar documents
Load Cells Page Option Option

Force and weight measuring instruments

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Force and weight measuring instruments

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

Model LBS Miniature Compression Load Button

Sensor Datasheet Collection

Remote Radio Control. WAVE Push button radio control systems

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1

Load cell system fault finding guide (Application Note: Number AN1)

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Single point load cell

Load Cells LOAD CELLS

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Load Cell Accessories and Services

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Ron 2000 Shackle Type Dynamometer with Remote Indicator

Model 3A Series 3-Axis Load Cell

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Model 3A Series 3-Axis Load Cell

Digital conductivity transmitter

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Ron 2150 Shackle Type Dynamometer with 2"/50mm Attachable Display

C10. Data sheet. Force transducer. Special features. B de

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Operating Manual Series Load Pins

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Non-Submersible Industrial Pressure Transducer

Single point load cell

MODEL AT-10 ANALOG TRANSMITTER

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

Torque Sensor Accessories and Services

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA

OEM radar transmitter, for aggressive media level measurement

Catalog of CLA force and torque sensors

Remotus. Robust radio remote control for safety critical industrial applications ROBUST SWEDISH DESIGN SINCE 1918

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

The transducer component converts the measured signal and displays the actual value.

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

LOAD CELLS AND WEIGHING SOLUTIONS

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

SENEL TECHNOLOGIES S.A. Load Cells Electronic Indicators

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Features. Picture. Specifications

C9C. Force Transducer. Special features. Data sheet

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

KFS. Flap-type flow meter. Design and range of application

Condumax CLS21 and CLS21D

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

U2B. Force Transducer. Special features. Data sheet

Analogue temperature controllers

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.

Dx: Digital Multi-Channel Telemetry System

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

U2B. Data sheet. Force Transducer. Special features. B en

4-20mA, 0-10V and general process measuring bargraph displays

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

Telemetrie-Messtechnik Schnorrenberg

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Positive Displacement Flow sensors

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

SonoMeter 31 Energy Meters

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

EN-2018 MAGNETIC FLOW METERS

LAUREL ELECTRONICS, INC.

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

U9C. Data sheet. Force Transducer. Special features. B en

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

MC2: Practicality for Calibration

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

XPC10 High temperature miniature pressure sensor

Introduction DIN rail mounted electricity meters

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Installation and Operating Manual

DTM.OCS.S/N - Modbus Level Transmitter

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

User s instructions. Page 1 sur 20 AXD-C / AAD-C / DVX-C / DVS-C : User s instructions B

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter

Digital flow ELEMENT transmitter for continuous flow measurement

Transcription:

Content: Load Cells Page Option Option Dynamometer, V-LINK 1 Wireless Remote Display, V-LINK 2 Mechanical Overload Switch 3 Static Line Tensiometer 4 Heavy Duty Tensiometer 5 ATEX Running Line Tensiometer 6 Shackle Pin 7 ATEX Load Pin 8 ATEX Junction Box 9 S Cell 10 ATEX OIML Compression Cell 11 Pressure Transducer 12 ATEX Bellows Bending Beam 13 ATEX ET Stainless Series 14 ATEX Bolt-on 15 ATEX OIML Bin Lift 16 ATEX OIML Silo Mount 17 Shear Beam 18 ATEX OIML Button Cell 19 Annular Load Cell 20 Display and Amplifier Options Page Amplifier 21 Panel Meter Display 22 Large Display 23 Remote Control 24 Nykredit Account

V-LINK Dynamometer 670601, 671201, 672501, 675501 Highly accurate and reliable, ±0,2% FS accuracy. Very clear red digit LED display. Visible at long distances / in bright daylight. IP Class 67. Ideal for wet/humid environments. Robust high strength steel construction for use in hostile environments. Supplied with full certificate of calibration. Delivered in smart carry case from hard ABS plastic. Designed and manufactured in DK for high quality assurance. Application: Crane and hoist calibration and proof load testing Capacity: 6.5T, 12T, 25T, 55T Accuracy: ±0,2% FS Safe overload: 110% Materials: High strenght steel housing. Fe/Zn12/A surface treatment according to ISO 2081 IP class: IP 67 Display: Bright LED Digit height: 14 mm Digit color: Red Operating time: 16-20 hours (Operating at low temperatures will decrease the operating time) Operation temp.: -20 C - +50 C Batteries: Build-in Li-on Charger: High quality USB charger Item No: Capacity (T) A (mm) B (mm) C (mm) D (mm) E (mm) Ø (mm) Weight (kg.) Increment (kg.) 670601 6.5 200.00 115.00 117.00 260.00 41.50 31.00 4.47 5 671201 12 200.00 115.00 117.00 281.00 41.50 37.30 5.65 10 672501 25 230.00 115.00 117.00 338.00 41.50 54.00 7.56 10 675501 55 282.00 115.00 155.00 440.00 46.00 73.00 16.93 20 Accessory options: WRDTX01 Wirless remote display Nykredit Account 1

Remote Display, Wireless WRDTX01 Handheld display for V-LINK Dynamometer. Enables measurements to be read from long distances and moving objects. Up to 99 Dynamometers with remote display can be used in the same area. Very easy to use. Highly reliable and comfortable. Application areas: For use with V-LINK Dynamometer only Range: 150 meters in free range Number of channels: 99 Standard frequency: 869.750 Mhz Communication form: Duplex RF output power: 10 mw IP class: IP65 Operating time: 16-20 hours Operating temp.: From -20 C - +50 C Batteries: Build-in LI-ON Charger: Standard USB charger, (also used for V-LINK Dynamometer) Item No: Dimensions Weight (kg.) WRDTX01 H145 x L88 x W23 mm 0.15 Nykredit Account 2

Load Limiter / Mechanical Overload Switch SM4067, SM4068 Designed for load limitation of hoisting devices and cranes. The compact size provides a minimal lifting height reduction. L150 mm. Quick and precise installation with simple tools. Can easily be adjusted to fit different wire types and capacities. Linear force development gives a user-friendly reaction pattern. Available with 1 or 2 cut off points. Designed and manufactured in DK for high quality assurance. Application areas: Load limitation of hoisting devices, cranes and overhead cranes. Suitable for a variety of industrial environments, including high-temperature and dusty environments. Can be used for low and high weights limits. Materials: Housing: Nickel plated steel. Hysteresis: Operating temp.: Springs: Heat treated spring steel, according to GB/T 13304. Axles: Max 4% FS CK45. 0 to 80 C. Below 0 C a heating device is recommended. Switch: UI: 500V UL Listed. Utilisator: AC-15:230V/4A IEC 60947-5-1 DC-13: 24V / 1A Item No: Wire Capacity Weight Dimensions SM4067-2 6-13 mm 500-1500 kg. per reeving 2,45 kg. W70 x H145 x L150 SM4067-4 6-13 mm 1500-3000 kg. per reeving 2,80 kg. W70 x H145 x L150 SM4067-6 6-13 mm 3000-5000 kg. per reeving 3,15 kg. W70 x H145 x L150 SM4068-2 13-20 mm 500-1500 kg. per reeving 2,45 kg. W70 x H145 x L150 SM4068-4 13-20 mm 1500-3000 kg. per reeving 2,80 kg. W70 x H145 x L150 SM4068-6 13-20 mm 3000-5000 kg. per reeving 3,15 kg. W70 x H145 x L150 Nykredit Account 3

Static Line Tensiometer WT1-N, WT2-N Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. Electronic clamp-on tensiometer, universal fit. Highly accurate and reliable, ±1% FS accuracy. Minimal lifting height reduction. Down to L100 mm. Quick and easy to install on the dead end of the wire rope. Designed and manufactured in DK for high quality assurance. Accuracy: ± 1% FS On unit: 0.1% FS Mounted: 0.1% x wire diameter x2. Output: 2.0 Nom MV/V balanced signal. Material: Alu 7075 Temperature: 0,0011 MV/C Input: EXC. 5-10 VDC Cable: 3 mtrs. (Up to 15 mtrs. as option) Item No: Wire (mm) Capacity (T) Dimensions (mm) Weight (kg.) WT1-N 6-15 mm 5T per reeving L100 x W62 x H65 0.8 kg. WT2-N 14-28 mm 10T per reeving L138x W80 x H85 1.5 kg. Complete systems: WT1-N + OL3000A WT1-N + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) WT1-N WT2-N Nykredit Account 4

Heavy Duty Tensiometer WT3 Combined load indication and load limitation system for hoisting devices and cranes with large wires. Electronic clamp-on tensiometer, universal fit. Highly accurate and reliable, ±1% FS accuracy. Fully welded stainless steel construction. Quick and easy to install on the dead end of the wire rope. Supplied with 10 mtrs. cable. Full Load Output: 1.0 nom mv/v Zero Load Output: <±5.0% Excitation (Max): Accuracy: 10 (15) V ±1% FS Repeatability: <0.25% Input Resistance: Output Resistance: 375 (±20) Ω 350 (±2) Ω Compensated Temp. Range: -10 to 40 C Operating Temp. Range: -20 to 60 C Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: 150% Insulation: <0.0010%Capacity/ C <0.0010%Capacity/ C >500 @ 100Vdc MΩ IP Class: IP68 Item No: Wire (mm) Capacity (kg.) Dimensions (mm) WT3-27-28 27-28 9700 L230 x H116 WT3-29-32 29-32 12600 L230 x H116 WT3-33-35 33-35 15100 L230 x H116 WT3-36-38 36-38 17900 L230 x H116 Complete systems: WT3 + OL3000A WT3 + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) Nykredit Account 5

Running Line Tensiometer RLT Combined load indication and load limitation system for moving wires. Accuracy down to 1%. Heavy duty ball bearing construction. Hardened stainless load pin. 3 standard housing models. Wide assortment of mounting accessories. Available in galvanised steel for corrosive environments. Capacity: Wire size: Output signal: IP Class: 1-1000T according to customer specifications. 13-38 mm 1mv/v at full load IP67 Relative humidity: >98% Operating Temp.: -20 C to +60 C. Under 0 C a heating device is recommended. Item No: Wire (mm) A (mm) B (mm) C (mm) Weight (kg.) RLT13 13 720 225 180 14.5 RLT16 16 720 225 180 21.5 RLT19 19 720 225 180 21.5 RLT22 22 810 270 186 37 RLT25 25 810 270 186 37 RLT28 28 810 270 186 37 RLT32 32 963 297 188 56 RLT35 35 963 297 188 56 RLT38 38 963 297 188 56 Complete systems: RLT + OL3000A RLT + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) RLT PAYOUTCOUNTER Payout counter. Mounting Arm: Wire (mm) D (mm) E (mm) Weight (kg.) RTL MOUNTINGARM1 13-19 810 1270 11 RTL MOUNTINGARM2 22-28 850 1320 11 RTL MOUNTINGARM3 32-38 850 1320 15 Nykredit Account 6

Shackle Pin SHA-PIN Robust stainless steel pin & bobbin for use in hostile environments. Highly accurate and reliable, ±0.5% FS accuracy. Bobbin and anti-rotation bracket for centralized, accurate loading. Green Pin shackles. Crosby shackles as option. 4-20 ma output. Telemetry and cabled version, 10 mtrs cable. To ensure the right fit shackles and load pins are always provided together. Full load output: 2.0 nom. mv/v Accuracy: ±0.5% FS Zero load output: <±2.0 % Repeatability: <0.10% Excitation (Max): 10 (15) V Safe overload: 150% Input resistance: 375 or 745 Ω IP class: IP66 Output resistance: 350 or 750 Ω Compensated temp. Range: -10 to 40 C Operating temp. Range: -20 to 60 C Temp. Coefficient on Zero: Temp. Coefficient on Span: <0.005 %Capacity/ C <0.003 %Capacity/ C Insulation: >500 @100Vdec MΩ Capacity: (T) A (mm) B (mm) C (mm) D (mm) L (mm) T (mm) 3,25 (only cabled) 75 40 16 19 57 27 6,5 100 54 22 25,4 84 38 12 146 76 32 35 119 50 25 216 106 45 50 146 73 35 238 127 51 57 187 83 42,5 287 134 57 65 212 95 55 311 142 68 70 267 105 85 355 163 75 83 309 127 120 420 203 89 95 368 133 150 460 229 100 108 371 140 250 625 305 115 127 475 215 Nykredit Account 7

Load Pin LOADPIN-18000 Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. Designed according to customers specifications as direct replacement for load bearing pins in lifting equipment. Provides the highest accuracy within weighing, ±0.1% FS accuracy. Robust stainless steel construction. IP68. Capacity: Proof load: Ultimate breaking load: Bridge resistance: Excitation: Output: Non-linearity: Non-repeatability: IP class: Operating temp.: Temp. Coefficient on Zero: Temp. Coefficient on Span: Signal cable: 0.1 to 1000T 150 % of rated load 500 % of rated load 350/700/1000 ohms 5 to 10 volts (dc) 1.0 to 1.5 mv/v ±1 % typical ±0.04 % optimum IP67-20 to 70 C <0.02 % Capacity/ C <0.02 % Capacity/ C 5 mtrs. Polyurethane 4 core Complete systems: LOADPIN + OL3000A LOADPIN + P1001, D1002 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) Options: Special anti-rotation / locking plates Second redundancy gauge bridge Internal signal amplifier Single shear pins fully welded Submersible Internal greaseways plug / socket breakdown at pi Nykredit Account 8

Junction Box JB02C-4-WB Junction Box fitted with electronic board for junction and equalisation of 4 and 6 load cells. Fully encapsulated, water proof and moisture proof. Easy connection of the load cells. Not weight dependant. Material: Cast aluminium housing. Protective coasting. Load cell output resistance range: 340 to 1100 Ω Load cell input resistance range: 340 to 1100 Ω Excitation, recommended voltage: 5 to 20V (AC&DC) Excitation, maximum: 30V (AC&DC) Load cell sensitivity range: 0.6-3 mv/v Cable Ø: 5 to 6.2 mm Correction method: Excitation trim Trimming range: 24 Ω Temperature range, operating: -40 to 85 C Housing connected to shield: Yes External grounding: No IP Class: IP65 Item No: Amount of connections Dimensions (mm) JB02C-4-WB 4 135 x 65 x 38 Nykredit Account 9

S Cell S-CELL Suitable for hanging, hopper and other weighing devices. Tension and compression applications. Stainless steel construction. Highly accurate and reliable. IP 68. C3 OIML R60 C3 Output sensitivity (= FS): 2.0 ± 0.008 mv/v 2.0 ± 0.004 mv/v Max. Numbr of load cell intervals: 3000 Ratio of min. LC verification interval: 7500 12000 Combined Error: ±0.0230 %FS Min. dead load: 0% Safe overload: 150% Ultimate overload: 300% Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: ± 1.5% FS 5 to12 V 18 V 350 ± 3 Ω 350 ± 3 Ω 5000 (at 50VDC) MΩ Compensated temperature: -10 to 40 C Operating temperature: -35 to 65 C Storage temperature: -40 to 70 C Item No: Capacity Output W (mm) H (mm) Diameter (mm) M (mm) S-CELL500KG-Z1 0.5T 2mV/V 32 25 Ø99 M12 x 1.75 S-CELL1000KG-Z1 1T 2mV/V 32 25 Ø99 M12 x 1.75 S-CELL2000KG-Z1 2T 2mV/V 32 25 Ø99 M20 x 1.5 S-CELL5000KG-Z1 5T 2mV/V 50 24 Ø99 M24 x 2 Nykredit Account 10

Compression Cell - High Capacity COMP Suitable for high precision applications such as dosing systems, machines and other scale applications. Stainless steel construction. Welded cover. Highly accurate and reliable. ±0.1% accuracy. Integral load button. Provided with 4 mtrs. Cable. Full load output: Zero load output: <±2.0% Excitation (Max): 2.0 (±0.25%) mv/v 10 (15) V Accuracy: <0.1% Repeatability: <0.1% Input resistance: Output resistance: 750 (±20) Ω 700 (±2) Ω Compensated temp.: -10 to 50 C Operating temp. Range: -20 to 60 C Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150% <0.005 % capacity/ C <0.005 % capacity/ C IP class: IP68 Item No: Capacity (T) AØ (mm) B (mm) C (mm) DØ (mm) E (mm) F (mm) G (mm) HØ (mm) COMP100T 100 229 60 70 87 200 132 272 10.5 COMP200T 200 299 60 70 87 200 132 272 10.5 COMP300T 300 299 73 85 155 260 165 340 10.5 COMP500T 500 299 105 120 155 260 165 340 10.5 COMP750T 750 299 105 120 155 260 165 340 10.5 Nykredit Account 11

Pressure Transducer PRESSTRANS Economical pressure measurement. Sealed gauge operation. Resistant to transients and spikes. Robust stainless steel construction. IP 67 Capacities: 50, 100, 200, 250, 350, 500, 700, 1000 bar. Full load output: 2.0 nom. mv/v Zero balance: <±5.0% Excitation (max): 10 (12) V Accuracy: <0.2% Repeatability: <0.10% Input resistance: 350Ω Output resistance: 350Ω Compensated temp. Range: -10 to 40 C Operating temp. Rage: -20 to 60 C Temp. Coefficient on zero: <0.040 % Capacity/ C Temp. Coefficient on span: <0.040 % Capacity/ C Safe overload: 150% Insulation: >500 @100Vdc MΩ Cable length: 4 mtrs. Item No: PRESSTRANS100B Options: Other ranges and non-standard sizes available on request Cable or plug and socket Connector Amplified outputs (voltage or current) Nykredit Account 12

Bellows Bending Beam BELLOWSBEAM Suitable for belt and tank weighing, bag fillers and platforms. Range 10-200 kg. Stainless steel construction, 17/4/PH. Hermetically sealed. Fully welded. 4 mtrs. Screened polyurethane cable. Easy installation. Rated output: Accuracy class: 2 ±0.1% mv/v 3000 n.oiml Combined error: <±0.017% Non repeatability: <±0.015% Creep 30 mins: <±0.016% Temp. effect on zero: <±0.001%/ C Temp. effect on span: <±0.001%/ C Compensated temp. Range: -10 to 40 C Operating temp. Range: -20 to 60 C Safe overload: 150% Ultimate overload: 200% Zero balance: <1% Input resistance: Output resistance: Insulation resistance: Supply voltage (nominal): Max voltage: 400±20 Ω 350±3 Ω >5000 MΩ@100VDC 10 V 15V Item No: ØA ØB C D E F ØG BELLOWSBEAM 42 34 20 24.5 53.5 42 8.2 ØH J K L M N P 27 10 82 120 18 10 30 Nykredit Account 13

ET Stainless Series TD Highly accurate and reliable, ±0.1% FS accuracy. Robust high strength steel construction for use in hostile environments. For use with standard shackles. Sealed to IP 68. Supplied with 10 mtrs. Cable and full certificate of calibration. Full Load Output: 1 (nominal) mv/v Zero Load Output: <±2.0% Excitation (Max): 10 (15) V Repeatability: <0.05% Input Resistance: 375 (±20) Ω Output Resistance: 350 (±2) Ω Compensated Temp. Range: -10 to 40 C Operation Temp. Range: -20 to 60 C Temp. Coefficient on Zero: <0.0010 %Capacity/ C Temp. Coefficient on Span: <0.0010 %Capacity/ C Safe Overload: 300% Insulation: >500 @100Vdc MΩ Item No: Capacity (T) A (mm) B (mm) C (mm) D (mm) Dia. (mm) TD1,5 1,5 175 110 70 17 16 TD2,5 2,5 185 120 70 25 20 TD5 5 185 120 70 25 26 TD7,5 7,5 200 135 75 25 35 TD10 10 270 170 90 30 36 TD12,5 12,5 270 170 90 30 39 TD15 15 270 170 90 30 43 TD20 20 350 220 120 50 52 TD25 25 350 220 120 50 52 Nykredit Account 14

BOLT-ON BOLT-ON Cost effective solution for high capacity. vessel/silo weighing applications. Robust construction. Simple installation. IP65. Supplied with 4 mtrs. Cable and all mounting accessories. BOSS-F BOSS-F Full Load Output: 1.0 nom. mv/v @1000psi 20.0 nom. mv/v @1000psi Zero Load Output: <±5.0% <±5.0% Excitation (Max): 10 (15)V 10 (15)V Accuracy: <0.25% <0.25% Repeatability: <0.04% <0.04% Terminal resistance: 350 nom.ω 2100 nom.ω Deflection: <0.5 mm <0.5 mm Compensated Temp. Range: -10 to 40 C -10 to 40 C Operation Temp. Range: -20 to 60 C -20 to 60 C Temp. Coefficient on Zero: 0.010% Capacity/ C 0.010% Capacity/ C Temp. Coefficient on Span: 0.005% Capacity/ C 0.010% Capacity/ C Safe Overload: 200% 200% Insulation: >5000@100Vdc MΩ >5000@100Vdc MΩ Item No: BOLT-ON Nykredit Account 15

Bin Lift Cell BINLIFT CELL Designed for extremely high fatigue stress and impact loads experienced in onbord vehicle weighing. Approved for commercial weighing to OIML R60 2000. Stainless steel construction. Fully welded. Ideal for hostile environments. High accuracy and durability. Excellent dynamic. Accuracy class: 0.1% C3 DT4650 Rated output 1.0 mv/v ±0,25% 0.88 mv/v Combined error 0.1 %FRO Non-repeatability: 0.02%FRO In accordance with Creep (30 mins): 0.03%FRO OIML Class C3 Temp. coef. of zero: Temp. coef. of span: 0.005 %FRO 0.002 %FRO Safe overload: 150 % 150% Ultimate overload: 300 % 300% Zero balance: <1 <1 Input resistance: 380 (±30) Ω 380 (±30) Ω Output resistance: 350 (±2) Ω 350 (±2) Ω Insulation: <5000 M Ω <5000 M Ω Excitation (max): 10 (15) Volts 10 (15) Volts Env. Protection: IP68 IP68 4-core screened cable: 2 mtrs. 2 mtrs. Item No: Capacity A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) BIN LIFT CELL 1T 1T 56 35,5 75 127 139 95 46 BIN LIFT CELL 2T 2T 56 35,5 75 127 139 95 46 BIN LIFT CELL 5T 5T 56 35,5 75 127 139 95 46 Nykredit Account 16

Silo Mount SILOCELL Complete silo weighing solution incorporating lift off prevention and silo expansion without compromising accuracy. Fully welded sensor. High tensile stainless steel type 17-4PH. High accuracy, durability and corrosion resistance. High resistance to off axis loads. Capacity: 0,5T, 1T, 2T, 5T, 7,5T, 10T, 15T, 20T, 30T, 50T, 75T, 100T Full Load Output: 2.0 (±0.25%) mv/v Zero Load Output: <±2.0% Excitation (Max): 10 (15) V Accuracy (combined error): <0.05% Repeatability: <0.01% Input resistance: 750 (±20) Ω Output resistance: 700 (±2) Ω Compensated Temp. Range: -10 to 40 C Operating Temp. Range: -20 to 60 C Temp. Coefficient on Zero: <0.005 % Capacity/ C Temp. Coefficient on Span: <0.003 % Capacity/ C Safe overload: 150% Insulation: >500 @100Vdc MΩ IP Class: IP68 Cable Length: 10 mtrs. Capacity (T) A (mm) B (mm) C (mm) D (mm) E (mm) ØF No.F G (mm) Mim. Exsp. 1-5T 105 150 94 124 88 13 8 12.7 3 mm 2-20T 140 200 125 165 117 18 8 18 4 mm 10-50T 175 280 175 230 162 22 8 25 6 mm 75T 240 300 190 250 184 26 12 25 6 mm 100T 250 320 230 300 210 26 12 30 8 mm Nykredit Account 17

Shear Beam SHEARBEAM Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices. Highly accurate and reliable. Stainless steel construction. Sealed to IP68. OIML R60 C3 OIML R60 C4 OIML R60 C5 OIML R60 C6 Output sensitivity (=FS): 2.0 ± 0.04 mv/v 2.0 ± 0.04 mv/v 3.0 ± 0.08 mv/v 3.0 ± 0.08 mv/v Maximum capacity (Emax): 0.5T, 1T, 1.5T, 2T, 2.5T, 3T, 5T, 7.5T, 10T 0.5, 1, 1.5, 2, 2.5T Max. Number of load cell interval: 3000 nlc 4000 nlc 5000 nlc 6000 nlc Ratio of min. LC verification interval: 1000 15000 20000 20000 Combined Error: ± 0.0230 %FS ± 0.0175 %FS ± 0.0140 %FS ± 0.0116 %FS Minimum dead load: Safe overload: Ultimate overload: Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: 0% of Emax 150% of Emax 300% of Emax <± 1.0% of FS 5 to 12 V 18 V 350 ± 3.5 Ω 350 ± 3.5 Ω Compensated temp.: -10 to 40 C Operating temp.: -35 to 65 C 5000 (at 50VDC) MΩ Storage temp.: -40 to 75 C Item No: Capacity (T) L x B x H (mm) ØD (mm) M SHEARBEAM-xxT-z1 0.5, 1, 1.5, 2 130 x 31.3 x 31.3 13.5 M12 SHEARBEAM-xxT-z1 2.5, 5 171 x 36.8 x 36.8 20.5 M20 SHEARBEAM-xxT-z1 7.5, 10 222 x 49.5 x 49.5 26.9 M24 Nykredit Account 18

Button Cell BUTTON Capacities 500kN to 20kN. Robust, durable and very compact construction. Highly accurate and reliable. ±0.25% accuracy. Low height. Integral load button. Compression applications. Easy connection to the customers' applications. Full load output: Zero load output: <±2.0%. Excitation (Max): 10 (15) V. Accuracy: <0.25%. Repeatability: <0.01%. 2.0 (±0.25%) mv/v. Input resistance: 375 (±20) Ω. Output resistance: 350 (±2) Ω. Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150%. Insulation: -10 C to 40 C. -20 C to 70 C. <0.0015 % capacity/ C. <0.002 % capacity/ C. >500 @ 100Vdc MΩ. IP class: IP65. Item No: Capacity (kn) A (mm) B (mm) C (mm) D (mm) Options: BUTTON0.5kN 0.5 15 7 0.5 4 Non-standard sizes available. BUTTON1kN 1 15 7 0.5 4 Other ranges on request. BUTTON2kN 2 15 7 0.5 4 Special mounting adaptors. BUTTON5kN 5 30 11 0.5 4 Shunt calibration facility. BUTTON10kN 10 30 11 0.5 4 Different temperature BUTTON20kN 20 30 11 0.5 4 compensation available. Nykredit Account 19

Annular Load Cell FORCE-WASHER Range 10kN to 200kN. Highly accurate and reliable. Robust, compact and low profile construction. Suitable for metric or imperial bolts. Compression applications. Easy connection to the customers' applications. Provided with 4 mtrs. cable length. Options: Full load output: 1.0 nom. mv/v. Other ranges available on request. Zero load output: <±1.0%. Full range of mounting options. Excitation (Max): 10 (15) V. Non-standard sizes available. Accuracy: <0.5%. Repeatability: <0.10%. Input resistance: 750 Ω. Output resistance: 700 Ω. Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150%. Insulation: -10 C to 40 C. -20 C to 60 C. <0.030 % capacity/ C. <0.0050 % capacity/ C. >500 @ 100Vdc MΩ. IP class: IP66. Item No: Capacity (kn) Bolt Size A (mm) B (mm) C (mm) FORCE-WASHER10kN 10 M6 18 6.1 12 FORCE-WASHER20kN 20 M8 22 8.1 12 FORCE-WASHER40kN 40 M10 28 10.2 12 FORCE-WASHER80kN 80 M12 38 12.2 15 FORCE-WASHER100kN 100 M16 42 16.3 20 FORCE-WASHER120kN 120 M24 50 24.3 25 FORCE-WASHER160kN 160 M30 60 30.5 30 FORCE-WASHER200kN 200 M36 75 36.5 30 Nykredit Account 20

Chassis Mount Cell CHASSISMOUNT Low height. Stainless load cell. IP 68. High accuracy. Alternative capacities available on request. Accuracy class: 0.5 C1.5 Type CMC Rated output: 1.2 ± 0.25% 0.72 mv/v Combined error: Non-repeatability: 0.5 %FRO 0.3 %FRO Creep (30 mins): 0.03 %FRO In accordance with OIML Temp. Coefficient on zero: 0.005 %FRO Class C1.5 Temp. Coefficient on span: Compensated temp.: Operating temp. Range: 0.002 %FRO -10 C to 40 C. -20 C to 60 C. Safe overload: 150% 200% Ultimate overload: 200% 300% Zero balance: <2% <2% Input resistance: 750 (±30)Ω 750 (±30)Ω Output resistance: 700 (±2)Ω 700 (±2)Ω Insulation: >5000 MΩ. >5000 MΩ. Excitation (max): 10(18) Volts 10(18) Volts 4-core screened cable: 10 mtrs. 10 mtrs. Capacity: A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) ØH (mm) 10T 198 152 269 326 57 63 M24 33 15T 198 152 269 326 63 63 M24 33 Nykredit Account 21

Amplifier OL3000A For overload protection on hoist, winches in lifting or crane applications. The load cell amplifier is used in conjunction with load cells as Static Line Tensiometers and Load Pins. Din rail mounted. Accuracy: <0.1% Output: 4-20 ma Features: Relays (n0) triggers at a user set level. Weight: 0.20 kg. Item No: Output Relay Output Dimensions OL3000A-230 230 VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A-48 48 VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A-115 115 VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A-24 24 VDC 4-20 ma 2 54 x 90 x 61 mm OL3000A-SUM 230 VAC 2 x 4-20 ma 2 54 x 90 x 61 mm Nykredit Account 22

Panel Meter P1001/6 Vetec Panel Meter Display is ideal in combination with load cells. Clear, variable brightness display. Provided with and without Relay output (alarms) and special output options. Very easy to programme and use. No-menu programming. High precision and long term reliability. Digits: Viewing: Input signals: Output options: IP Class: Materials: Case dimensions: 6 digits. 14 mm digit height. Up to 7m away. Load cells 4-20mA, 0-10V, 1-5V etc. Serial Data RS232, RS485 etc. 2 or 4 alarms SPST relays, 2x SPDT. 4-20mA, 0-10V or -10 to +10 analog. RS232, RS485, Modbus, Ethernet. RTU Modbus for Tiger G2. IP65 front. 1/8 DIN format case. Black polycarbonate. W 96 x H 48 x L136 mm, (±1mm) Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-R-AC-0 6 14 mm 95-265 VAC - 0 P1001/6-L-R-DC-0 6 14 mm 11-30 VDC - 0 P1001/6-L-ANI-R-AC 6 14 mm 95-265 VAC 4-20 ma 0 P1001/6-L-ANI-R-DC 6 14 mm 11-30 VDC 4-20 ma 0 Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-AL2-R-AC 6 14 mm 95-265 VAC - 2 P1001/6-L-AL2-R-DC 6 14 mm 11-30 VDC - 2 P1001/6-L-ANI-AL2-R-AC 6 14 mm 95-265 VAC 4-20 ma 2 P1001/6-L-ANI-AL2-R-DC 6 14 mm 11-30 VDC 4-20 ma 2 Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-ANI-R-AC 6 14 mm 95-265 VAC 4-20 ma 0 P1001/6-L-485-R-AC 6 14 mm 95-265 VAC RS485 0 P1001/6-L-RTU-R-AC 6 14 mm 95-265 VAC MODBUS RTU (Tiger) 0 P1001/6-L-A2-RTU-R-AC 6 14 mm 95-265 VAC MODBUS RTU (Tiger) 2 * The listed examples are all with load cell input. Other displays can be provided to meet specific requirements and applications. Nykredit Account 23

Large Display D1002, D1004 Vetec Large Display is ideal in combination with load cells. Provided with and without Relay Output (alarms) and special output options. Remote setting from ground level. Very easy to programme and use. No-menu programming. Digits: Input signals: Output options: IP Class: Materials: Available with 4 and 6 digits. Load cells. 4-20mA, 0-10V, 1-5V etc. Serial Data RS232, RS485, 422 etc. 2 or 4 alarms SPST relays, 2x SPDT. 4-20mA, 0-10V or -10 to +10 analog. RS232, RS485, Ethernet data output. IP65 for bottom glands, IP54 for top. Black polycarbonate. Examples, all with load cell input. Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1002/4-L-R-AC-3 4 57 mm 25 mtrs. 95-265 VAC 0 - D1004/4-L-R-AC-3 4 102 mm 50 mtrs. 95-265 VAC 0 - D1004/6-L-R-AC-3 6 102 mm 50 mtrs. 95-265 VAC 0 - D1004/6-L-R-48VAC-3 6 102 mm 50 mtrs. 48 VAC 0 - Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1002/4-L-AL2-R-AC-3 4 57 mm 25 mtrs. 95-265 VAC 2 - D1004/4-L-AL2-R-AC-3 4 102 mm 50 mtrs. 95-265 VAC 2 - D1004/6-L-AL2-R-AC-3 6 57 mm 25 mtrs. 95-265 VAC 2 - D1004/6-L-AL2-R-48-3 6 102 mm 50 mtrs. 48 VAC 2 - Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1004/4-L-ANI-AC-3 4 102 mm 50 mtrs. 95-265 VAC 0 4-20Ma D1004/4-L-485-AC-3 4 102 mm 50 mtrs. 95-265 VAC 0 RS485 D1004/4-L-A2-RTU-AC-3 4 102 mm 50 mtrs. 95-265 VAC 2 MODBUS RTU D1004/6-L-A2-RTU-AC-3 6 102 mm 50 mtrs. 95-265 VAC 2 MODBUS RTU * Other displays can be provided to meet specific requirements and other applications. Nykredit Account 24

Remote Controls TIGER G2 Tiger G2 has been developed for radio controlled lifting applications, e.g. EOT cranes, container cranes and more. Transmitters with display show load indication when combined with our complete load cell systems. For maximum load control and safety. Channels: 69. Approvals: IP Class: The stop function and two relays in the receivers are approved according to SIL3 IEC 61508 standard and PLe. Transmitters and receivers are approved according to IP65. TG-T9 transmitters are approved according to IP66. All receivers IP66. Item No.: Frequency Channels Buttons TG-T9-2 433 MHz, 915 MHz and 2,4 GHZ 69 6 TG-T11-4 433 MHz, 915 MHz and 2,4 GHZ 69 10 TG-T12-20 433 MHz and 915 MHz 69 Joystick TG-T12-21 433 MHz and 915 MHz 69 Joystick Item No.: Frequency Channels Relays TG-R4-1 433 MHz, 915 MHz and 2,4 GHZ 69 2+7 TG-R4-6 433 MHz, 915 MHz and 2,4 GHZ 69 2+17 TG-R9-11 433 MHz and 915 MHz 69 2+2+28 Nykredit Account 25