Energy Efficient Distribution Transformers

Similar documents
Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

T S 15KVA 1PH 240/480 Transformer

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

Non-Linear Load Transformers

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

HPS Universal BUCK-BOOST TRANSFORMERS

2.1. Product Description

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

Effects of Harmonic Distortion I

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Load Isolation Transformers

Drive Isolation Transformers

Steps for Selecting the Proper Transformer

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

General Description & Features Selection Charts Definition of Terms... 42

Transformer Questions & Answers

Dry-Type Transformers

K Factor Power Transformers

ULTRA-K Series 600K - he

Transformer Questions & Answers

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Technical Data and Specifications. Core and Coil Assemblies

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Variable Transformers Product Design & Engineering Data

Liquid-Filled Transformers

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Power Processor - Series 700F 10KVA to 150KVA

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

Isolation Transformer Series

BUCK-BOOST TRANSFORMERS

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Low Pass Harmonic Filters

(

Challenges of Parallel Operations

Harmonic Mitigating Transformer - Technical Guide

Tech Byte 16: The Truths About Transformers Part 2

What is a Transformer?

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

Full Line Product Catalog

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Low Voltage Transformers. Selection Guide

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Line Frequency Transformer

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

SECTION TRANSFORMERS

Electromagnetic Harmonic Filters Technical Guide

Warehouse Stock Transformers

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

General Purpose Transformers

High Frequency Sinewave Guardian TM Filter

Table of Contents. Facility EMI Filter Products

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Bridgeport Magnetics Design Guide

Transformer Factory Testing

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Power-Sure 700. Technical Data TD158001EN. Contents

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English

Presents. Harmonics Years

Section 2 Outdoor Voltage Transformers

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Basic Principles and Operation of Transformer

Full Line Product Catalog

Transcription:

Energy Efficient Distribution Transformers

Established in 1917, Hammond Power Solutions Inc. (HPS), is an industry leader in magnetic transformer design and development. With our headquarters in Guelph, Canada, HPS operates out of multiple facilities globally. HPS has expanded it s manufacturing and product base to offer the broadest ranges of both standard and specialty transformers. Low Voltage Distribution Transformer Energy Efficiency Guidelines In the past several years, there has been an accelerated rate of change to introduce energy efficiency standards for transformers in North America. Many products have preceded these initiatives for transformers in an overall effort to optimize manufactured goods for environmental concerns. Governments are encouraging users to consider energy efficient products like dry-type transformers, to help reduce carbon dioxide emissions. In addition to the benefits to the environment, energy efficient transformers realize substantial savings in operating costs, thereby having a direct impact on the initial investment evaluated over a period of time.

Construction Features HPS transformers are designed and constructed to meet or exceed the requirements for general applications. Construction features of HPS Energy Efficient Distribution Transformers include: Core Construction HPS cores are manufactured from the highest quality non-aging, cold rolled, silicon steel laminations. Cores are precision cut to close tolerances to eliminate burrs and interleaved to improve performance. Full mitre stepped core construction is used for our very high efficiency transformers. Coil Construction Coils are available in either aluminum or copper construction. Coils are precision wound with continuous copper or aluminum conductors and are electrically balanced to minimize axial short-circuit forces. The use of duct stick permits the flow of air, thus providing excellent cooling in addition to providing superior radial mechanical strength. Insulation System The insulation rating is the maximum allowable winding (hot spot) temperature of a transformer operating at an ambient temperature of 40 C. Insulation systems are classified by the temperature rating. HPS energy efficient distribution transformers utilize superior insulation materials which meet or exceed UL standards. Higher ambient temperatures and/or continuous overload characteristics can be achieved with low temperature rise design. Terminations HPS transformers are provided (where applicable) with both high and low voltage terminal lug connectors suitable for both copper and aluminum cables. These connectors allow for easy field installation without the need to purchase connectors separately, saving the installer both time and money. Vacuum Pressure Impregnation (VPI) Regardless of voltage class, our polyester resin impregnation system is preferred. This material is a blend of a vinyl-toluene polyester resin and exhibits much higher dielectric strength and bonding properties than most varnishes previously used, or other encapsulations including oil modified epoxies. The VPI process ensures that the insulating resin penetrates all voids completely, and provides a superior result compared to simple dip and bake operations. Testing HPS has testing facilities in all manufacturing locations to ensure product quality. These testing capabilities include: Heat Run, Ratio, Polarity, Partial Discharge, Induced Voltage Test, Sound Level, Transformer Losses under linear and nonlinear load conditions, Applied Power Frequency Voltage Test, EMF, BIL, Insulation Resistance, Inductance and Resistance. HPS has a state-of-the-art test bench that can test transformer efficiencies with non-linear load profile up to K-Factor 20. Core Construction Coil Construction Terminations VPI Testing

Canada - Energy Efficiency (CSA C802.2) The laws in Canada state that all low voltage dry-type distribution transformers (see table) manufactured after January 1st, 2005, must meet the minimum energy efficiency guidelines outlined by CSA C802.2 and referenced in the Canadian Energy Efficiency Act - Energy Efficiency Regulations (SOR/94-651). Maximum Losses for Distribution, Power and Dry-Type Transformers. The HPS lines of 1.2kV class energy efficient distribution transformers illustrated in this section, meet or exceed the minimum efficiencies required. These efficiencies are evaluated at 35% of the nameplate kva transformer capacity. The range of product covered by these standards are: Primary (high) Voltage Secondary (low) Voltage Line Current Dry-Type Single Phase Rating Three Phase Frequency 1.2kV Less than 4000 amps 15-333kVA 15-1000kVA 60 Hz only United States - Energy Efficiency (DOE 10 CFR Part 431/TP1) The laws in the U.S. state that all low voltage dry-type distribution transformers (see table) manufactured after January 1st, 2007, must meet the minimum energy efficiency standards outlined in DOE 10 CFR Part 431 (typically referred to as TP1). Energy Conservation Program for Commercial Equipment: Distribution Transformers Energy Conservation Standards; Final Rule. The HPS lines of 600 volt class energy efficient distribution transformers illustrated in this section meet or exceed the minimum efficiencies required. These efficiencies are evaluated at 35% of the nameplate rated load. The range of product covered by these standards are: Voltage Rating Dry-Type Rating Primary Voltage Secondary Voltage Single Phase Three Phase Frequency 600 volt and below 600 volt and below 15-333kVA 15-1000kVA 60 Hz only

NEMA Premium Efficiency Transformer Program On June 9 th, 2010 the National Electrical Manufacturers Association (NEMA) announced the initiation of the NEMA Premium Efficiency Transformer Program, which will help utilities, commercial buildings, and industrial plants incorporate super high-efficiency transformers into their operations. The adoption of this program will not only reduce energy consumption, but will also reduce carbon dioxide emissions. The new NEMA Premium Efficiency Transformer designation requires 30 percent fewer losses than existing DOE regulations (10 CFR 431)/TP1 for low-voltage dry-type distribution transformers. Below is a comparison between the NEMA Premium efficiency levels versus the DOE 10 CFR Part 431/TP1 and C802.2 efficiency levels. Single Phase - Low Voltage kva Rating DOE/TP1 & C802.2 NEMA Premium 15 97.70% 98.39% 25 98.00% 98.60% 37.5 98.20% 98.74% 50 98.30% 98.81% 75 98.50% 98.95% 100 98.60% 99.02% 167 98.70% 99.09% 250 98.80% 99.16% 333 98.90% 99.23% Three Phase - Low Voltage kva Rating DOE/TP1 & C802.2 NEMA Premium 15 97.00% 97.90% 30 97.50% 98.25% 45 97.70% 98.39% 75 98.00% 98.60% 112.5 98.20% 98.74% 150 98.30% 98.81% 225 98.50% 98.95% 300 98.60% 99.02% 500 98.70% 99.09% 750 98.80% 99.16% 1000 98.90% 99.23% For more information about the NEMA Premium Efficiency Transformer Program, visit: http://www.nema.org/technical/pages/nema-premium-efficiency-transformers-program.aspx As a Partner in the NEMA Premium Efficiency Transformer Program, HPS has determined that the HPS SuperSentinel, HPS SuperSynergy, and HPS SuperCenturion meet the NEMA Premium Efficiency guidelines for super high-efficiency. (NEMA Premium is a trademark of National Electrical Manufacturers Association.)

Distribution Transformer Products & Applications HPS offers three types of low voltage energy efficient distribution transformers, they include: Linear Load General Purpose Transformers - HPS Sentinel & HPS SuperSentinel They are generally used for supplying appliance, lighting, heating, motorized machine and power loads from electrical distribution systems. They are either ventilated, totally enclosed. For non-linear loads, all standard energy efficient general purpose distribution transformers have to be derated to allow for additional heat due to harmonic losses (see HPS Synergy below). HPS Sentinel (part number prefix nmk or nmf) Meets DOE 10 CFR Part 431/TP1 and C802.2 efficiencies at 35% of rated load. Efficiencies are calculated under a linear load profile. HPS SuperSentinel (part number prefix smk or smf) Exceeds DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 efficiencies at 35% of rated load. Efficiency performance will meet the NEMA Premium guidelines; 30% lower losses than DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 standards; when measured under a linear load profile. Non-Linear Load K-Factor Transformers - HPS Synergy & HPS SuperSynergy Energy efficient K-factor transformers are designed to tolerate heating due to harmonics associated with non-linear loads. They have become a popular means of addressing these related overheating problems where electronic ballasts, drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations. Harmonics can indicate their presence in a number of ways: overheating, device malfunctions, telephone interference, equipment vibration, and breakers tripping. These non-linear loads generate harmonic currents which can substantially increase transformer losses. The K-rated transformer has a more rugged design intended to prevent failure due to overheating, a 200% rated neutral and full electrostatic shield. K-factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 60Hz. It is used to specify transformers for non-linear loads. Standard K-factor ratings are 4, 13, 20 and other ratings are available. HPS Synergy (part number prefix nmt) Meets DOE 10 CFR Part 431/TP1 and C802.2 efficiencies at 35% of rated load. Efficiencies are calculated under a linear load profile. HPS SuperSynergy (part number prefix smt) Efficiency performance will meet the NEMA Premium guidelines; 30% lower losses than DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 efficiency standards; when measured under a linear load profile at 35% of rated load. Efficiency will meet or exceed DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 efficiency standards for linear load even at 50% of rated load when measured under a non-linear load up to K13.

Harmonic Mitigating Transformers - HPS Centurion & HPS SuperCenturion Harmonic Mitigating transformers are superior to K-rated and general purpose transformers in that they reduce voltage distortion (flat-topping) and power losses due to current harmonics created by single-phase, non-linear loads such as computer equipment. Secondary windings are arranged to cancel zero sequence fluxes and eliminate primary winding circulating currents. They treat zero sequence harmonics (3rd, 9th and 15th) within the secondary windings and 5th and 7th harmonics upstream with appropriate phase shifting. Dual output, phase shifting Harmonic Mitigating Transformers provide extremely low output voltage distortion and input current distortion even under severe non-linear load conditions (Data Centers, Internet Service Providers, Telecom Sites, Call Centers, Broadcasting Studios, etc.). Combining zero sequence flux cancellation with phase shifting treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. Features of Harmonic Mitigating Transformers: Prevents voltage flat-topping caused by non-linear loads Reduces upstream harmonic currents Eliminates transformer overheating and high operating temperatures Eliminates primary winding circulating current Saves energy by reducing harmonic losses Maintains high energy efficiency even under severe non-linear loading conditions Electrostatic shielding for high frequency noise attenuation Reduces voltage distortion to prevent premature equipment failure Increases ride-through capability of computer equipment Treats power quality harmonic issues which K-rated transformers do not address Suitable for high K-factor loads Reduces current distortion at UPS, generator or Utility service Improves Upstream Total Power Factor Helps meet IEEE Standard 519 harmonic limits HPS Centurion (part number prefix h1em or h2em) Meets DOE 10 CFR Part 431/TP1 and C802.2 efficiencies at an operating range from 35% to 65% of rated linear load. Meets DOE 10 CFR Part 431/TP1 and C802.2 efficiency standards when measured under a non-linear load profile up to K20 in an operating range from 35% to 50%. HPS SuperCenturion (part number prefix s1em or s2em) Exceeds DOE 10 CFR Part 431/TP1 and (if applicable) C802.2 efficiencies at 35% of rated load. Efficiency performance will meet NEMA Premium guidelines; 30% lower losses than DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 efficiency standards when measured under a linear load profile. Efficiencies will exceed DOE 10 CFR Part 431/TP1 and (if applicable) CSA C802.2 standards at an operating range from 35% to 65% of rated load when measured under a non-linear load profile up to K20. * For a complete listing of HPS Energy Efficient part numbers, please refer to the HPS online catalog.

The following chart illustrates the standard features of HPS Energy Efficient Low Voltage Distribution transformers for General Purpose, K-Factor and Harmonic Mitigating Transformers. Distribution Transformer Standard Features Chart Standard Features/Options Description Sentinel Series (General Purpose - for linear loads) Synergy Series (K-Factor - for non-linear loads) Centurion Series (Harmonic Mitigating - for linear & non-linear loads) STANDARD FEATURES kva Range Single Phase: 15kVA - 333kVA Three Phase: 15kVA - 1000kVA Frequency 60 Hertz Winding Material Aluminum Copper Shielding Single Shield OPT Double Shield OPT OPT OPT Primary Taps Meet or Exceed NEMA Custom Primary Taps OPT OPT OPT Enclosure Rating Type 3R Type 3RE, Type 4, Type 4X (HPS standard is stainless steel), Type 12 OPT OPT OPT Enclosure Finish ANSI 61 Grey, UL50 Custom Sprayed-On Water Based Paint OPT OPT OPT Custom Baked-On Enamel Paint OPT OPT OPT Stainless Steel (304 or 316) OPT OPT OPT Insulation System 15 to 30kVA Cu 130 C Temperature Rise, 200 Insulation Class 15 to 30kVA Cu 115 C Temperature Rise, 200 Insulation Class OPT OPT OPT 15 to 30kVA Cu 80 C Temperature Rise, 200 or 220 Insulation Class OPT OPT OPT 15 to 30kVA Al 150 C Temperature Rise, 220 Insulation Class 15 to 30kVA Al 80 C, 115 C, 130 C Temperature Rise, 220 Insulation Class OPT OPT 45 to 750kVA Cu & Al 150 C Temperature Rise, 220 Insulation Class 45 to 750kVA Cu & Al 130 C Temperature Rise, 220 Insulation Class OPT OPT 45 to 750kVA Cu & Al 80 C, 115 C Temperature Rise, 220 Insulation Class OPT OPT OPT

Impedance Standard Features/Options Description Sentinel Series (General Purpose - for linear loads) Synergy Series (K-Factor - for non-linear loads) Centurion Series (Harmonic Mitigating - for linear & nonlinear loads) Typically 2.5% to 6.5% Custom Impedance OPT OPT OPT Sound Level Meets NEMA ST-20 Options below NEMA ST-20 available OPT OPT OPT K-Factor Nameplate Rating K-Factor 4 (Load Profile up to K9) K-Factor 13 (Load Profile up to K20) K-Factor 20 (Load Profile up to K30) OPT Other OPT OPT Neutral 100% of Nameplate under linear loads 200% Neutral Internal Phase Shifting 0 30 0 & 30 or 15 & 45 OPT Other Secondary Output Single Dual Duty Standard Duty Drilling Duty OPT OPT OPT Marine Duty OPT OPT OPT Accessories Many accessories available, please consult factory for details OPT OPT

Nema Premium Savings versus Standard Efficiency Transformers The graph below illustrates the difference between the standard energy efficiency levels (DOE/TP1 and C802.2) and the NEMA Premium efficiency levels for three phase kva ratings: 100.0% 99.5% 99.0% NEMA Premium DOE/TP1 and C802 Efficiency Level 98.5% 98.0% 97.5% 97.0% 96.5% 15 30 45 75 112.5 150 225 300 500 750 1000 kva Rating HPS has an Energy Savings Calculator available on the HPS Tool Box website (www.hpstoolbox.com) designed to help calculate energy cost savings using HPS Energy Efficient Distribution Transformers. The table below demonstrates the savings for a typical Industrial plant with a 75kVA transformer (operating 300 days/year and loading at 100% 16hrs/day and 50% 8hrs/day) using the HPS Energy Savings Calculator. Transformer Energy Consumption (kwh) Annual Energy Costs Energy Savings DOE (TP1)/C802.2 Compliant Transformer HPS Sentinel Energy Efficient General Purpose NEMA Premium Transformers 12808.5 $1,280.85 $885.57 (vs. Non-DOE/C802.2) HPS SuperSentinel Super Energy Efficient General Purpose 9017.3 $901.73 $1,264.69 (vs. Non-DOE/C802.2) $344.33 (vs. DOE/C802.2) Visit the HPS Tool Box (www.hpstoolbox.com) Energy Savings Calculator to find out how HPS can help reduce your energy consumption, and costs for your application.

HPS Standard Features Plus Benefits Equals Cost Savings These standard options save contractors time and labor: Features Primary Terminal Lugs* Secondary Terminal Lugs* Standard Conduit Knock Outs* Drip Shield Benefits Primary Terminal Lugs included with most kva ranges. Purchase of separate lugs to install at additional cost not required. Secondary Terminal Lugs included with most kva ranges. Purchase of separate lugs to install at additional cost not required. Save installation time by eliminating the need to punch conduit entry holes. Additional protection for the transformer from falling water. Drip shield included. Purchase and installation of Drip Shield not required. Contractor Savings Cost ($) Time (min.) $25 to $100 30 min. $25 to $100 30 min. $45 to $75 20 min. $50 to $200 15 to 30 min. Wall Mounting Brackets* Base Mounting Holes Pointed Outward* Horizontal Vent Screens Laminated High Efficiency Steel Core Coils - VPI Polyester Resin Helps to save space. Wall mounting brackets included on units up to 45kVA. $50 to $150 15 to 30 min. Easy access for mounting. $10 to $50 5 to 15 min. Added cooling effect. Optimum energy efficiency. Improved performance. Exhibits much higher dielectric strength and bonding properties than any varnishes previously used, or other encapsulations including oil modified epoxies. Longevity of life at maximum transformer temperatures. Heavy-Duty Mounting Feet or Base Channel Standard NEMA 3R Rated Enclosure Loop Taps Aluminum or Copper Windings Provides superior support in all mounting conditions and decreases possibility of shipping damage. May be used for either indoor or outdoor use (also available in a non-ventilated version). No assembly required. Does not require additional brazing during construction and eliminates brazed joints. More options based on budget. Reduces returns due to freight damage. No special order or additional parts required. * see HPS catalog for range ~ Estimated Total Savings ~ Time: 1 hrs 55 min to 2 hrs 35 min Material & Labor Cost: $205 to $675

CANADA 595 Southgate Drive Guelph, Ontario N1G 3W6 Tel: (519) 822-2441 Fax: (519) 822-9701 Toll Free: 1-888-798-8882 cdnsales@hammondpowersolutions.com UNITED STATES 1100 Lake Street Baraboo, Wisconsin 53913-2866 Tel: (608) 356-3921 Fax: (608) 355-7623 Toll Free: 1-866-705-4684 Compton, CA Baraboo, WI Granby, Quebec Guelph, ON Walkerton, ON ussales@hammondpowersolutions.com Monterrey, MX Scan this QR code to check out our HPS Tool Box, or go to www.hpstoolbox.com Distributed by: www.hammondpowersolutions.com Literature No.: ENEDIS Issue Date: May 2013