EN 55022: 2006+A1: 2007 EN : 2007 EN 55024: 2010 EN : 2006+A2: 2009 EN : Measurement and Test Report.

Similar documents
FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

EN V1.9.2 EN V Measurement and Test Report YAMAY ELECTRONICS CO., LTD.

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

TABLE OF CONTENTS 1.GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY...4

FCC PART MEASUREMENT AND TEST REPORT

2004/104/EC Measurement and Test Report

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

For. Tzone FCC ID: FCC Part Description: Product TZ-BT04. Report to Tested By: Manager STR I

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

FCC Part 22H & 24E Measurement and Test Report

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

EMC VERIFICATION SUMMARY Report No.: SZHH

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

FCC PART 15 B MEASUREMENT AND TEST REPORT

EMC Test Report. Report Number: M030826

1- GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

FCC PART 15 B MEASUREMENT AND TEST REPORT

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

EMC Test report for LED Panel Light Models , , , , ,

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For Prokits Industries Co., Ltd.

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

RADIO TEST REPORT. For Shenzhen ZD Intelligent Technology Co., Ltd.

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Report No.: BST Y ER 2 RADIO TEST REPORT. For Shenzhen sinocam Technology Co.,LTD.

TEST REPORT... 1 CONTENT...

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

2620 Modular Measurement and Control System

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC test report AU01+E04

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

FCC PART TEST REPORT. Weccan Industrial Limited

Page: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China

PT. SARANA KARYA SOLUSINDO.

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

For Sky. Phone LLC. FCC Part 22H. FCC Rules: 3G Smart Phone. Report No.: By: Tested By: Manager. Prepared. Shenzhen SEM.

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Measurement and Test Report

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

TEST REPORT. Shenzhen, PRC.

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

9. Electrostatic Discharge Immunity Test (ESD)

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Test Report GUANGDONG EAST POWER CO., LTD

CE EMC Test Certification

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Declaration of Conformity

1 SUMMARY OF STANDARDS AND RESULTS

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

King Pigeon Communication Co., Limited

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Transcription:

EN 55022: 2006+A1: 2007 EN 60601-1-2: 2007 EN 55024: 2010 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3: 2008 Measurement and Test Report Report Concerns: Original Report Model: Report No.: For GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA Equipment Type: Power supply GT(-or M)41060(-or CC)-WWVV-X.X(or-FW) series STR11098193E Test Date: 2011-09-22 to 2011-09-27 Issue Date: 2011-09-28 Test Engineer: Jason Jiang / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: SEM.Test Compliance Service Co., Ltd 3/F, Jinbao Commerce Building, Xin'an Fanshen Road, Bao'an District, Shenzhen, P.R.C.(518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by SEM.Test Compliance Service Co., Ltd. REPORT NO.: STR11098193E PAGE 1 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

TABLE OF CONTENTS 1.GENERAL INFORMATION...4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...4 1.2 TEST STANDARDS...4 1.3 TEST METHODOLOGY...5 1.4 TEST FACILITY...5 1.5 EUT EXERCISE SOFTWARE...6 1.6 ACCESSORIES EQUIPMENT LIST AND DETAILS...6 1.7 EUT CABLE LIST AND DETAILS...6 1.8 PERFORMANCE CRITERIA...6 2. SUMMARY OF TEST RESULTS...7 3. CONDUCTED EMISSIONS...8 3.1 MEASUREMENT UNCERTAINTY...8 3.2 TEST EQUIPMENT LIST AND DETAILS...8 3.3 TEST PROCEDURE...8 3.4 BASIC TEST SETUP BLOCK DIAGRAM...8 3.5 ENVIRONMENTAL CONDITIONS...9 3.6 SUMMARY OF TEST RESULTS/PLOTS...9 3.7 CONDUCTED EMISSIONS TEST DATA...9 4. RADIATED EMISSION...14 4.1 MEASUREMENT UNCERTAINTY...14 4.2 TEST EQUIPMENT LIST AND DETAILS...14 4.3 TEST PROCEDURE...14 4.4 CORRECTED AMPLITUDE & MARGIN CALCULATION...15 4.5 ENVIRONMENTAL CONDITIONS...15 4.6 SUMMARY OF TEST RESULTS/PLOTS...15 5. EN 61000-3-2 HARMONIC CURRENT EMISSIONS...20 5.1 TEST EQUIPMENT LIST AND DETAILS...20 5.2 TEST PROCEDURE...20 5.3 TEST STANDARDS...20 5.4 EN 61000-3-2: HARMONIC CURRENT EMISSIONS TEST DATA...20 6. EN 61000-3-3 VOLTAGE FLUCTUATION AND FLICKER...21 6.1 TEST EQUIPMENT LIST AND DETAILS...21 6.2 TEST PROCEDURE...21 6.3 TEST STANDARDS...21 6.4 EN 61000-3-3: VOLTAGE FLUCTUATION AND FLICKER TEST DATA...21 7. ELECTROSTATIC DISCHARGE IMMUNITY (ESD)...25 7.1 TEST EQUIPMENT LIST AND DETAILS...25 7.2 TEST PROCEDURE...25 7.3 EN61000-4-2: ELECTROSTATIC DISCHARGE IMMUNITY TEST DATA...25 8. CONTINUOUS RADIATED DISTURBANCES...27 8.1 TEST EQUIPMENT LIST AND DETAILS...27 8.2 TEST PROCEDURE...27 8.3 EN61000-4-3: CONTINUOUS RADIATED DISTURBANCES TEST DATA...27 9. ELECTRICAL FAST TRANSIENTS...28 9.1 TEST EQUIPMENT LIST AND DETAILS...28 9.2 TEST PROCEDURE...28 9.3 EN61000-4-4: ELECTRICAL FAST TRANSIENTS TEST DATA...28 10. SURGE...29 10.1 TEST EQUIPMENT LIST AND DETAILS...29 10.2 TEST PROCEDURE...29 10.3 EN61000-4-5: SURGE TEST DATA...29 11. CONTINUOUS CONDUCTED DISTURBANCES...30 11.1 TEST EQUIPMENT LIST AND DETAILS...30 REPORT NO.: STR11098193E PAGE 2 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

11.2 TEST PROCEDURE...30 11.3 EN61000-4-6: CONTINUOUS CONDUCTED DISTURBANCES TEST DATA...30 12. POWER-FREQUENCY MAGNETIC FIELD...31 12.1 TEST EQUIPMENT LIST AND DETAILS...31 12.2 TEST PROCEDURE...31 12.3 EN61000-4-8: VOLTAGE DIPS AND INTERRUPTIONS TEST DATA...31 13. VOLTAGE DIPS AND INTERRUPTIONS...32 13.1 TEST EQUIPMENT LIST AND DETAILS...32 13.2 TEST PROCEDURE...32 13.3 EN61000-4-11: VOLTAGE DIPS AND INTERRUPTIONS TEST DATA...32 EXHIBIT 1- PRODUCT LABELING...33 PROPOSED CE LABEL FORMAT...33 PROPOSED LABEL LOCATION ON EUT...33 EXHIBIT 2 - EUT PHOTOGRAPHS...34 EXHIBIT 3 - TEST SETUP PHOTOGRAPHS...37 EXHIBIT 4 - SCHEMATICS...40 EXHIBIT 5 - USERS MANUAL...40 REPORT NO.: STR11098193E PAGE 3 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

1.GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) Client Information Applicant: Address of applicant: Manufacturer1: Address of manufacturer1: Manufacturer2: Address of manufacturer2: General Description of E.U.T Items EUT Description: Trade Name: Model No.: Description Power supply GlobTek Rated Voltage: AC 100-240V Rated Current: 0.6A GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA GlobTek (Suzhou) Co., Ltd Building 4, No. 76, Jin Ling East Rd., Suzhou Industrial Park, Suzhou, JiangSu 215021, China GT(-or M)41060(-or CC)-WWVV-X.X(or-FW) series For more information refer to the circuit diagram form and the user s manual. GT(-or M)41060(-or CC)-WWVV-X.X(or-FW) series: (-or M):M=Medical -=Information Technology (-or CC): - =Constant Voltage Model, CC=Constant Current Model WW is the rated output wattage designation, with a maximum value of "25"; VV is the standard rated output voltage designation, with a maximum value of "30"; -X.X is optional or blank and denotes the output voltage differentiator, subtracting or adding X.X volts forom standard output voltage VV in 0.1 increments -FW=Open Frame which is optional. The test data is gathered from a production sample, provided by the manufacturer. The other model listed in the report has different appearance only of GT(-or M)41060(-or CC)-WWVV-X.X(or-FW) series without circuit and electronic construction changed, declared by the manufacturer 1.2 Test Standards The following report is prepared on behalf of the GlobTek, Inc. in accordance with EN55022, Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement, and EN55024, Immunity characteristics Limits and methods of measurement. and EN61000-3-2: 2006+A2: 2009, Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase). EN61000-3-3: 2008, Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply REPORT NO.: STR11098193E PAGE 4 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection. EN60601-1-2: 2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance Collateral standard: Electromagnetic compatibility Requirements and tests. The objective of the manufacturer is to demonstrate compliance with EN55022 Class B limits for Information Technology Equipment and and EN55024, Immunity characteristics Limits and methods of measurement. And EN60601-1-2: 2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance Collateral standard: Electromagnetic compatibility Requirements and tests. Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product maybe which result in lowering the emission/immunity should be checked to ensure compliance has been maintained. 1.3 Test Methodology All measurements contained in this report were conducted with EN 55022, Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement, and EN55024, Immunity characteristics Limits and methods of measurement. And EN60601-1-2: 2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance Collateral standard: Electromagnetic compatibility Requirements and tests. The equipment under test (EUT) was configured to measure its highest possible emission/immunity level. The test setup was adapted accordingly in reference to the Operating Instructions. 1.4 Test Facility FCC Registration No.: 994117 SEM.Test Compliance Services Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files and the Registration is 994117. Industry Canada (IC) Registration No.: 7673A The 3m Semi-anechoic chamber of SEM.Test Compliance Services Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 7673A. REPORT NO.: STR11098193E PAGE 5 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

CNAS Registration No.: L4062 Shenzhen SEM.Test Electronics Service Co., Ltd. is a testing organization accredited by China National Accreditation Service for Conformity Assessment (CNAS) according to ISO/IEC 17025. The accreditation certificate number is L4062. All measurement facilities used to collect the measurement data are located at 3/F, Jinbao Commerce Building, Xin an Fanshen Road, Bao an District, Shenzhen, P.R.C (518101) 1.5 EUT Exercise Software The EUT exercise program used during radiated and conducted testing was designed to exercise the system components. The test software is started while the EUT is on to simulate the normal work. 1.6 Accessories Equipment List and Details Description Manufacturer Model Serial Number / / / / 1.7 EUT Cable List and Details Cable Description Length (M) Shielded/Unshielded With Core/Without Core DC Cable 1.5 Unshielded Without Core 1.8 Performance Criteria All the test data has been collected, reduced, and analyzed within this report in accordance with Immunity requires the following as specific performance criteria: A. The apparatus shall continue to operate as intended during and after the test. The manufacturer specifies some minimum performance level. The performance level may be specified by the manufacturer as a permissible loss of performance. B. The apparatus shall continue to operate as intended after the test. This indicates that the EUT does not need to function at normal performance levels during the test, but must recover. Again some minimal performance is defined by the manufacture. No change in operating state or loss or data is permitted. C. Temporary loss of function is allowed. Operation of the EUT may stop as long as it is either automatically reset or can be manually restored by operation of the controls. REPORT NO.: STR11098193E PAGE 6 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

2. SUMMARY OF TEST RESULTS Description of Test Result EN55022 Conducted Emission Compliant EN55022 Radiated Emission Compliant EN61000-3-2 Harmonic Current Emission Compliant EN61000-3-3 Voltage Fluctuation And Flicker Electrostatic Discharge Immunity (ESD) in accordance with EN55024&EN60601-1-2&EN 61000-4-2 Radiated RF-Electromagnetic Field Immunity in accordance with EN55024&EN60601-1-2&EN 61000-4-3 Electrical Fast Transient/Burst (EFT/B) immunity in accordance with EN55024&EN60601-1-2&EN 61000-4-4 Surge immunity test immunity in accordance with EN55024&EN60601-1-2&EN 61000-4-5 Immunity to conducted disturbances in accordance with EN55024&EN60601-1-2&EN 61000-4-6 Voltage Dips/Interruptions immunity test in accordance with EN55024&EN60601-1-2&EN 61000-4-11 Compliant Compliant Compliant Compliant Compliant Compliant Compliant REPORT NO.: STR11098193E PAGE 7 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

3. CONDUCTED EMISSIONS 3.1 Measurement Uncertainty Base on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any conducted emissions measurement is + 2.88 db. 3.2 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date EMI Test Receiver Rohde & Schwarz ESPI 101611 2010-12-20 2011-12-19 L.I.S.N Schwarz beck NSLK8126 8126-224 2010-12-20 2011-12-19 Pulse Limiter Rohde & Schwarz ESH3-Z2 100911 2010-12-20 2011-12-19 AMN EMCO 3825/2 11967C 2010-12-20 2011-12-19 Power Divider Weinschel 1506A PM204 2010-12-20 2011-12-19 Current Probe FCC F-33-4 091684 2010-12-20 2011-12-19 3.3 Test Procedure Test is conducting under the description of EN 55022 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement 9. 3.4 Basic Test Setup Block Diagram LISN EUT Load 10m To Receiver 1.5 0.8m Non-conduction table above Ground Plane 1. 5 m REPORT NO.: STR11098193E PAGE 8 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

3.5 Environmental Conditions Temperature: 22 C Relative Humidity: 55 % ATM Pressure: 1015 mbar 3.6 Summary of Test Results/Plots According to the data in section 3.7, the EUT complied with the EN55022 Conducted margin for a Class B device, with the worst margin reading of: -6.33 dbμv at 2.994 MHz in the Neutral mode GTM41060CC2530, Average detector, 0.15-30MHz 3.7 Conducted Emissions Test Data REPORT NO.: STR11098193E PAGE 9 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Plot of Conducted Emissions Test Data Conducted Disturbance EUT: Power supply M/N: GT-41060-1505 Operating Condition: Full Load Test Specification: N Comment: AC 230V dbµv 1 PK MAXH 2 AV MAXH 100 90 80 70 0 -QP 60 -AV 50 40 30 20 10 Att 10 db AUTO RBW 9 khz MT 100 ms 1 MHz 10 MHz 150 khz 30 MHz Trace1: Trace2: EDIT PEAK LIST (Prescan Results) -QP -AV Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 1 Max Peak 154 khz 47.14-18.63 2 Average 154 khz 36.42-19.35 TDF 6DB REPORT NO.: STR11098193E PAGE 10 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EUT: Power supply M/N: GT-41060-1505 Operating Condition: Full Load Test Specification: L Comment: AC 230V dbµv 1 PK MAXH 2 AV MAXH 100 90 80 70 -QP 60 -AV 50 40 30 20 10 0 Att 10 db AUTO RBW 9 khz MT 5 ms 1 MHz 10 MHz 150 khz 30 MHz EDIT PEAK LIST (Prescan Results) Trace1: -QP Trace2: -AV Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 1 Max Peak 154 khz 47.03-18.75 2 Average 154 khz 37.76-18.01 2 Average 17.774 MHz 31.96-18.03 1 Max Peak 17.87 MHz 40.04-19.95 TDF 6DB REPORT NO.: STR11098193E PAGE 11 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Plot of Conducted Emissions Test Data Conducted Disturbance EUT: Power supply M/N: GTM41060CC2530 Operating Condition: Full Load Test Specification: N Comment: AC 230V dbµv 1 PK MAXH 2 AV MAXH 100 90 80 70 60 50 40 30 20 10 0 -QP -AV Att 10 db AUTO RBW 9 khz MT 5 ms 1 MHz 10 MHz 150 khz 30 MHz Trace1: Trace2: EDIT PEAK LIST (Prescan Results) -QP -AV Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 1 Max Peak 562 khz 39.25-16.74 2 Average 562 khz 35.45-10.54 1 Max Peak 622 khz 39.59-16.40 2 Average 2.058 MHz 38.61-7.38 1 Max Peak 2.994 MHz 40.21-15.78 2 Average 2.994 MHz 39.66-6.33 2 Average 18.19 MHz 33.20-16.79 TDF 6DB REPORT NO.: STR11098193E PAGE 12 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EUT: Power supply M/N: GTM41060CC2530 Operating Condition: Full Load Test Specification: L Comment: AC 230V dbµv 1 PK MAXH 2 AV MAXH 100 90 80 70 -QP 60 -AV 50 40 30 20 10 0 Att 10 db AUTO RBW 9 khz MT 5 ms 1 MHz 10 MHz 150 khz 30 MHz EDIT PEAK LIST (Prescan Results) Trace1: -QP Trace2: -AV Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 2 Average 310 khz 30.24-19.72 2 Average 1.618 MHz 32.54-13.46 1 Max Peak 2.986 MHz 36.49-19.50 2 Average 2.986 MHz 34.27-11.72 2 Average 14.866 MHz 35.06-14.93 TDF 6DB REPORT NO.: STR11098193E PAGE 13 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

4. RADIATED EMISSION 4.1 Measurement Uncertainty Base on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any radiation emissions measurement is + 5.10 db. 4.2 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Spectrum Analyzer R&S FSP 836079/035 2010-12-20 2011-12-19 EMI Test Receiver R&S ESVB 825471/005 2010-12-20 2011-12-19 Positioning Controller C&C CC-C-1F N/A 2010-12-20 2011-12-19 RF Switch EM EMSW18 SW060023 2010-12-20 2011-12-19 Pre-amplifier Agilent 8447F 3113A06717 2010-12-20 2011-12-19 Pre-amplifier Compliance Direction PAP-0118 24002 2010-12-20 2011-12-19 Trilog Broadband Antenna SCHWARZBECK VULB9163 9163-333 2011-01-09 2012-01-08 Horn Antenna ETS 3117 00086197 2011-01-09 2012-01-08 4.3 Test Procedure Test is conducting under the description of EN 55022 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement 10 Antenna Tower EUT SYS Turntable Table 0.8m 3m 1m-4m To EMI Receiver Ground Plane REPORT NO.: STR11098193E PAGE 14 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

4.4 Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor, and subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as follows: Corr. Ampl. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain The Margin column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of -6dBμV means the emission is 6dBμV below the maximum limit for Class B. The equation for margin calculation is as follows: Margin = Corr. Ampl. EN55022& Class B Limit 4.5 Environmental Conditions Temperature: 23 C Relative Humidity: 53% ATM Pressure: 1011 mbar 4.6 Summary of Test Results/Plots According to the data in section 4.6, the EUT complied with the EN55022 Class B standards, and had the worst margin is: -3.03 dbμv at 30.4238 MHz in the, Vertical polarization, Model GTM)41060CC2505, Quasi peak mode, 30 MHz to 6 GHz, 3Meters REPORT NO.: STR11098193E PAGE 15 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Plot of Radiation Emissions Test Data Radiated Emission EUT: Power supply M/N: GT-41060-1505 Operating Condition: Full Load Test Specification: Horizontal & Vertical Comment: AC 230V Horizontal No. Frequency Reading Correct Result Limit Margin Degree Height Remark (MHz) (dbuv/m) db/m (dbuv/m) (dbuv/m) (db) ( ) (cm) 1 31.9546 20.21 6.77 26.98 40.00-13.02 360 100 peak 2 105.2718 18.91 7.99 26.90 40.00-13.10 360 100 peak REPORT NO.: STR11098193E PAGE 16 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Vertical: No. Frequency Reading Correct Result Limit Margin Degree Height Remark (MHz) (dbuv/m) db/m (dbuv/m) (dbuv/m) (db) ( ) (cm) 1 30.4238 30.20 6.77 36.97 40.00-3.03 360 100 QP 2 35.0048 29.25 6.77 36.02 40.00-3.98 360 100 peak 3 42.8998 25.18 8.20 33.38 40.00-6.62 360 100 peak Note: emissions are only the base noise in frequency 1GHz~6GHz. REPORT NO.: STR11098193E PAGE 17 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Radiated Emission EUT: Power supply M/N: GTM41060CC2530 Operating Condition: Full Load Test Specification: Horizontal & Vertical Comment: AC 230V Horizontal No. Frequency Reading Correct Result Limit Margin Degree Height Remark (MHz) (dbuv/m) db/m (dbuv/m) (dbuv/m) (db) ( ) (cm) 1 30.8535 20.56 6.77 27.33 40.00-12.67 360 100 peak 2 54.0711 16.36 7.80 24.16 40.00-15.84 360 100 peak 3 104.5361 15.88 8.04 23.92 40.00-16.08 360 100 peak REPORT NO.: STR11098193E PAGE 18 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Vertical: No. Frequency Reading Correct Result Limit Margin Degree Height Remark (MHz) (dbuv/m) db/m (dbuv/m) (dbuv/m) (db) ( ) (cm) 1 32.4059 27.38 6.77 34.15 40.00-5.85 360 100 peak Note: emissions are only the base noise in frequency 1GHz~6GHz. REPORT NO.: STR11098193E PAGE 19 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

5. EN 61000-3-2 HARMONIC CURRENT EMISSIONS 5.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Digital Power Em Test Analyzer AG/Switzerland Em Test Source AG/Switzerland 5.2 Test Procedure Test is conducting under the description of EN61000-3-2: 2006+A2: 2009 5.3 Test Standards EN61000-3-2: 2006+A2: 2009 Limit: Clause 7 Environmental Conditions Temperature: 22 C Relative Humidity: 48% ATM Pressure: 1022 mbar DPA 500 V0745103095 2010-12-20 2011-12-19 ACS 500 V0745103096 2010-12-20 2011-12-19 5.4 EN 61000-3-2: Harmonic Current Emissions Test Data According to Clause 7 of EN 61000-3-2:2006+A2: 2009, the EUT (rate power is 25W) is less than 75W, belong to equipment with a rated power of 75W or less, therefore limits are not specified in this edition of the standards. It is deem to full fit the requirements of the standards. Test Result: Pass REPORT NO.: STR11098193E PAGE 20 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

6. EN 61000-3-3 VOLTAGE FLUCTUATION AND FLICKER 6.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Digital Power Em Test Analyzer AG/Switzerland Em Test Source AG/Switzerland 6.2 Test Procedure Test is conducting under the description of EN61000-3-3: 2008 6.3 Test Standards EN61000-3-3: 2008 Limit: Clause 5 Environmental Conditions Temperature: 22 C Relative Humidity: 48% ATM Pressure: 1022 mbar DPA 500 V0745103095 2010-08-12 2011-08-11 ACS 500 V0745103096 2010-08-12 2011-08-11 6.4 EN 61000-3-3: Voltage Fluctuation and Flicker Test Data Flicker Test Summary per EN/IEC61000-3-3 (Run time) EUT: GT-41060-1505 Tested by: JASON J Test category: All parameters (European limits) Test Margin: 100 Test date: 2011-9-24 Start time: 03:51:39 PM End time: 04:01:55 PM Test duration (min): 10 Comment: FULL LOAD Customer: Customer Test Result: Pass Data file name: F-000094.cts_data Status: Test Completed Pst i and limit line European Limits REPORT NO.: STR11098193E PAGE 21 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

1.00 0.75 Pst 0.50 0.25 16:01:54 Plt and limit line 0.50 Plt 0.25 0.00 16:01:54 Parameter values recorded during the test: Vrms at the end of test (Volt): 230.60 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass REPORT NO.: STR11098193E PAGE 22 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Flicker Test Summary per EN/IEC61000-3-3 (Run time) EUT: GTM41060CC2530 Tested by: JASON J Test category: All parameters (European limits) Test Margin: 100 Test date: 2011-9-24 Start time: 03:36:17 PM End time: 03:46:33 PM Test duration (min): 10 Data file name: F-000093.cts_data Comment: FULL LOAD Customer: Customer Test Result: Pass Status: Test Completed Pst i and limit line European Limits Pst 1.00 0.75 0.50 0.25 15:46:32 Plt and limit line Plt 0.50 0.25 0.00 15:46:32 Parameter values recorded during the test: Vrms at the end of test (Volt): 230.65 REPORT NO.: STR11098193E PAGE 23 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass Test Result: Pass REPORT NO.: STR11098193E PAGE 24 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

7. Electrostatic Discharge Immunity (ESD) 7.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date ESD Generator TESQ AG NSG 437 161 2010-12-20 2011-12-19 7.2 Test Procedure Test is conducting under the description of EN 61000-4-2. Test Performance Performance Criterion: B Environmental Conditions Temperature: 26 C Relative Humidity: 55% ATM Pressure: 1011 mbar 7.3 EN61000-4-2: Electrostatic Discharge Immunity Test Data Table 1: Electrostatic Discharge Immunity (Air Discharge) EN 61000-4-2 Test Levels (kv) Test Points -2 +2-4 +4-6 +6-8 +8-15 +15 Slots A A A A A A A A Table 2: Electrostatic Discharge Immunity (Direct Contact) EN 61000-4-2 Test Levels (kv) Test Points -2 +2-4 +4-6 +6-8 +8-15 +15 DC Port A A A A REPORT NO.: STR11098193E PAGE 25 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP) EN 61000-4-2 Test Levels (kv) Test Points -2 +2-4 +4-6 +6-8 +8-15 +15 Front Side A A A A Top Side A A A A Back Side A A A A Left Side A A A A Right Side A A A A Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP) EN 61000-4-2 Test Levels (kv) Test Points -2 +2-4 +4-6 +6-8 +8-15 +15 Front Side A A A A Top Side A A A A Back Side A A A A Left Side A A A A Right Side A A A A Test Result: Pass REPORT NO.: STR11098193E PAGE 26 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

8. Continuous Radiated Disturbances 8.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Signal Generator Rohde & Schwarz SMT03 100059 2010-12-20 2011-12-19 Voltage Probe Rohde & Schwarz URV5-Z2 100013 2010-12-20 2011-12-19 Power Amplifier AR 150W1000 300999 2010-12-20 2011-12-19 Power Amplifier AR 25S1G4AM1 305993 2010-12-20 2011-12-19 Trilog Antenna SCHWARZBECK VULB9163 9163-333 2011-01-09 2012-01-08 Anechoic chamber Albatross Projects MCDC ---- 2010-03-20 2012-03-19 8.2 Test Procedure Test is conducting under the description of EN 61000-4-3. Test Performance Performance Criterion: A Environmental Conditions Temperature: 25 C Relative Humidity: 52% ATM Pressure: 1010 mbar 8.3 EN61000-4-3: Continuous Radiated Disturbances Test Data Frequency step: 1% of fundamental Dwell time: 1 second Frequency Range (MHz) 80-2500 Test Result: Pass Front (3 V/m) Rear (3 V/m) Left Side (3 V/m) Right Side (3 V/m) VERT HORI VERT HORI VERT HORI VERT HORI A A A A A A A A REPORT NO.: STR11098193E PAGE 27 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

9. Electrical Fast Transients 9.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Transient 2000 EMC PARTNER TRA2000 863 2010-12-20 2011-12-19 Couple Clamp EMC PARTNER CN-EFT1000 513 2010-12-20 2011-12-19 9.2 Test Procedure Test is conducting under the description of EN 61000-4-4. Test Performance Performance Criterion: B Environmental Conditions Temperature: 22 C Relative Humidity: 53% ATM Pressure: 1011 mbar 9.3 EN61000-4-4: Electrical Fast Transients Test Data Power Supply Power Line of EUT EN 61000-4-4 Test Levels (kv) Test Points +0.5-0.5 +1.0-1.0 +2.0-2.0 +4.0-4.0 L1 A A B B / / / / L2 A A B B / / / / Earth / / / / / / / / L1+L2 A A B B / / / / L1 + Earth / / / / / / / / L2 + Earth / / / / / / / / L1+L2+Earth / / / / / / / / Signal ports / / / / / / / / Test Result: Pass REPORT NO.: STR11098193E PAGE 28 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

10. Surge 10.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Transient 2000 EMC PARTNER TRA2000 863 2009-10-09 2010-10-08 Couple Clamp EMC PARTNER CN-EFT1000 513 2009-10-09 2010-10-08 10.2 Test Procedure Test is conducting under the description of EN 61000-4-5. Test Performance Performance Criterion: B Environmental Conditions Temperature: 25 C Relative Humidity: 53% ATM Pressure: 1011 mbar 10.3 EN61000-4-5: Surge Test Data Level Voltage Poll Path Pass Fail 1 0.5kV ± L-N A / 2 1kV ± L-N A / 3 2kV ± L-PE, N-PE / / 4 4kV ± L-N, L-PE, N-PE / / Test Result: Pass REPORT NO.: STR11098193E PAGE 29 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

11. Continuous Conducted Disturbances 11.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Immunity simulator 11.2 Test Procedure EMTEST MV500 0800-44 2010-12-20 2011-12-19 Test is conducting under the description of EN 61000-4-6. Test Performance Performance Criterion: A Environmental Conditions Temperature: 25 C Relative Humidity: 53% ATM Pressure: 1011 mbar 11.3 EN61000-4-6: Continuous Conducted Disturbances Test Data Sweep frequency range: 150kHz~80MHz Frequency step: 1% of fundamental Dwell time: 1 second Voltage Level Level (e.m.f.) U 0 Modulation: Pass Fail 1 1 AM 80%, 1kHz sinewave / / 2 3 AM 80%, 1kHz sinewave A / 3 10 AM 80%, 1kHz sinewave / / X Special / / / Test Result: Pass REPORT NO.: STR11098193E PAGE 30 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

12. Power-Frequency Magnetic Field 12.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date EMCPRO KEYTEK EMCPro 0509124 2010-12-20 2011-12-19 Coil KEYTEK F-1000-4-8 0533 2010-12-20 2011-12-19 12.2 Test Procedure Test is conducting under the description of IEC 61000-4-8:2009. Test Performance Performance Criterion: A Environmental Conditions Temperature: 25 C Relative Humidity: 50% ATM Pressure: 1011 mbar 12.3 EN61000-4-8: Voltage Dips And Interruptions Test Data Level Magnetic Field Strength Frequency Induction Coil (r.m.s) Hz Postion A/m Pass Fail 1 1 50 X, Y, Z / / 2 3 50 X, Y, Z A / 3 10 50 X, Y, Z / / X Special / / / Test Result: Pass REPORT NO.: STR11098193E PAGE 31 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

13. Voltage Dips And Interruptions 13.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Transient 2000 EMC PARTNER TRA2000 863 2010-12-20 2011-12-19 Couple Clamp EMC PARTNER CN-EFT1000 513 2010-12-20 2011-12-19 13.2 Test Procedure Test is conducting under the description of EN 61000-4-11. Test Performance Performance Criterion: B/C Environmental Conditions Temperature: 25 C Relative Humidity: 50% ATM Pressure: 1011 mbar 13.3 EN61000-4-11: Voltage Dips And Interruptions Test Data Level U2 td Phase Angle N Pass Fail 1 >95% 10ms 0/90/180/270 3 A / 2 30% 500ms 0/90/180/270 3 B / 3 60% 100ms 0/90/180/270 3 C / 4 >95% 5000ms 0/90/180/270 3 C / Test Result: Pass REPORT NO.: STR11098193E PAGE 32 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EXHIBIT 1- PRODUCT LABELING Proposed CE Label Format Specifications: Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT CE Label Location REPORT NO.: STR11098193E PAGE 33 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EXHIBIT 2 - EUT PHOTOGRAPHS EUT View 1 EUT View 2 REPORT NO.: STR11098193E PAGE 34 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EUT Housing and Board View 1 Solder Board-Component View 1 REPORT NO.: STR11098193E PAGE 35 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

Solder Board-Component View 2 REPORT NO.: STR11098193E PAGE 36 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EXHIBIT 3 - TEST SETUP PHOTOGRAPHS Conduction Emission Test View Radiation Emission Test View REPORT NO.: STR11098193E PAGE 37 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

IEC 61000-4-2 IEC 61000-4-3 REPORT NO.: STR11098193E PAGE 38 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

IEC 61000-4-4/-5/-11 IEC 61000-4-6 REPORT NO.: STR11098193E PAGE 39 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3

EXHIBIT 4 - SCHEMATICS EXHIBIT 5 - USERS MANUAL ***** END OF REPORT ***** REPORT NO.: STR11098193E PAGE 40 OF 40 EN 55022/24 EN 60601-1-2 EN 61000-3-2/3