IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

Similar documents
IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

PORTABLE PARTIAL DISCHARGE MONITORING INSTRUMENT

PARTIAL DISCHARGE MEASUREMENT ON ROTATING MACHINES

A6500-UM Universal Measurement Card

Why partial discharge testing makes good sense

3500/64M Dynamic Pressure Monitor

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Stator Winding Partial Discharge Activity for Air- Cooled Generators

CONTINUOUS ON-LINE SYSTEM FOR PARTIAL DISCHARGE MONITORING FOR HA1 AT CHE ROBEŞTI

Relative Ability of UHF Antenna and VHF Capacitor Methods to Detect Partial Discharge in Turbine Generator Stator Windings

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

PD Solutions. On-Line PD Measurement Devices

The Generators and Electric Motor Monitoring and Diagnostics Systems

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Isolators A3/1. Vibration Transducer Supply Unit Series

EXPERIENCE WITH ON-LINE PARTIAL DISCHARGE MEASUREMENT IN HIGH VOLTAGE INVERTER FED MOTORS

the 3500/44M Aeroderivitive GT Vibration Monitor for the

Ieee Guide For Partial Discharge Testing Of Shielded Power

MIT510/2, MIT520/2 and MIT1020/2

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

Objective Methods to Interpret Partial-Discharge Data on Rotating-Machine Stator Windings

On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

Partial Discharge, Survey or Monitor?

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

DOBLE F6150SV TECHNICAL SPECIFICATIONS

RECENT DEVELOPMENTS IN IEEE AND IEC STANDARDS FOR OFF-LINE AND ON-LINE PARTIAL DISCHARGE TESTING OF MOTOR AND GENERATOR STATOR WINDINGS

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

ICARUS ELECTRONIC GAS VOLUME CONVERTER

DOBLE F6150e TECHNICAL SPECIFICATIONS

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

PARTIAL DISCHARGE MEASUREMENT

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Fisher 646 Electro Pneumatic Transducer

Trendmaster * Dynamic Scanning Module

Diagnostic testing of cast resin transformers

On-line Flux Monitoring of Hydro-generator Rotor Windings

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

II. TRADITIONAL APPROACH OF PD MEASUREMENTS

Binary Output without Power Supply Series 9176

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Current clamps for AC current

Further Experience in the Use of Existing RTDs in Windings of Motors and Generators for the Measurement of Partial Discharges

1587/1577 Insulation Multimeters

Power Quality Solutions

RTD as a Valuable Tool in Partial Discharge Measurements on Rotating Machines

Indeks: WMXXCMM60 Advanced Industrial Multimeter

Advanced, accurate and intelligent monitoring for your transformer

CB Scheme UL508 UL ATEX II3G

Improve asset protection and utilization

Fisher 646 Electro-Pneumatic Transducers

Binary Output Series 9175

Investi ations Into the Use of Temperature Detectors as # tator Winding Partial Discharge Detectors

1 INTRODUCTION ORDER CODE / INFORMATION

MIT510, MIT520 and MIT1020

Dielectric response and partial discharge measurements on stator insulation at varied low frequency. Nathaniel Taylor

Emicon Engineering Consultants L.L.C.

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

The importance of partial discharge testing throughout the development and operation of power transformers

Protection components

4-20 ma Vibration Transmitter, Top connector

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

MINI MCR-SL-UI-I-LP-NC

Partial Discharge Theory, Modeling and Applications To Electrical Machines

Rosemount 702 Discrete Input Transmitter

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Head mounted Temperature Transmitter TF02/TF02-Ex

DM-45 Digital Multimeter

Safety Instructions Nivotester FTC625, FTC325

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Partial discharge diagnostics on very long and branched cable circuits

Low Frequency Velocity Sensor

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

Temperature Input Module for Zone 1 Series 9482/32

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

IP26 Series Current to Pneumatic Converter

EMI Installation Guidelines

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

A1-209 EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS

PD Diagnostic Applications and TechImp solutions

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

A NOVEL APPROACH TO PARTIAL DISCHARGE MONITORING

SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Practical Experience in On-Line Partial Discharge Measurements of MV Switchgear Systems

V P N. Voltage transducer DVM 4200 = 4200 V

79/26 Series III Multimeter

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Fluke Digital Multimeters Solutions for every need

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

Isolators A3/1.

FRAX Series Sweep Frequency Response Analyzers

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

Fluke 1587 FC/1577 Insulation Multimeters

Transcription:

IRIS POWER PDTracII Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

We have not found another test method that produces as much decision support data for generator stator maintenance planning based on actual in-service insulation condition... Analysts were able to recommend the needed corrective maintenance before the maintenance outages began. Partial Discharge Is A Leading Symptom Of Failures On Stator Windings and Switchgear Insulation problems are one of the principal causes of forced outages for generators, motors, switchgear and dry type transformers which result in considerable damage and lost revenues. Periodic online monitoring of partial discharge provides a cost effective and proven technique to minimize the risk of unexpected failures. Other 1% Bearing / Shaft 12% Rotor Winding 12% Avoid In Service Failures With Early Detection Of Failure Mechanisms FAILURE MECHANISMS FOR GENERATORS Allianz insurance, Survey 1996-1999 VDE Colloquium, June 28, 2001 Stator Winding 63% Stator Core 12% Partial Discharge monitoring has become an important tool for condition based maintenance by identifying risks of failure caused by abrasion of insulation, loose stator windings, thermal degradation of insulation and manufacturing defects. Global Acceptance Of Online Partial Discharge Monitoring Partial discharges in degrading high voltage stator windings give rise to small current pulses that travel through the stator winding. The magnitude and number of these pulses depend on the degree of insulation deterioration. As the magnitude and number of partial discharge current pulses increase, the amount of electrical insulation deterioration is also increasing. Partial Discharge monitoring has won worldwide acceptance across utilities, major industrial companies and manufacturers. Iris Power has provided products for partial discharge monitoring on over 16,000 assets globally in addition to partial discharge monitoring being recommended in industry standards such as IEEE Standard 1434-2014, IEC TS 60034-27-2:2012 and IEC 62478-2016. Iris Power online partial discharge monitoring instruments have accurately identified problems on many hundreds of generators and motors with hundreds of case studies and dozens of published papers by Iris Power customers that confirm Iris Power partial discharge monitoring instruments can help: Prioritize assets needing immediate maintenance Identify and repair damage at an earlier stage Avoid in-service failures Reduce outage frequency when machine conditions present low risk of failures. Obtain information regarding the type and location of maintenance required prior to outages Reduce overall cost of maintenance

Development Of Iris Power Partial Discharge Monitoring The development of Iris Power partial discharge testing instruments in 1990 s was funded by the North American utility industry (CEA and EPRI) to provide machine owners a method of detecting stator winding insulation problems and obtaining adequate data to make maintenance decisions independent of equipment manufacturers. The PDTracII was designed specifically for monitoring partial discharges under normal electrical, mechanical and thermal machine operating stresses. There are now over 65,000 Iris Power partial discharge Epoxy Mica Capacitive Sensors installed across thousands of motors, generators, dry type transformers and metal glad switchgear globally that are monitored by Iris Power portable and continuous instruments. Sensor Installation and Configuration Iris Power Epoxy Mica Capacitors (EMCs) are 80 pf capacitors that are used to attenuate low frequency from the generator since impedance is inversely proportional to frequency. The 60 Hz or 50 Hz power frequency is filtered with 100 s MΩ impedance while the high frequency partial discharge pulses up to 250 MHz easily pass through the EMC with only 10 s Ω impedance. This allows the PDTracII to monitor small partial discharge pulses of over 2 mv on machines rated over 3.3 kv. Iris Power typically installs two 80pF epoxy mica capacitive couplers per phase on generators. Noise pulses originating outside the machine arrive at the sensor closer to the system first. Pulses originating in the machine winding arrive at the sensor nearest the machine first. This allows Iris Power instruments to automatically distinguish between noise and winding partial discharge. Motors, small generators and transformers connected with over 30 m of cable between the machine and the switchgear can leverage just one epoxy mica capacitive sensor per phase and a PDTracII to automatically analyze the pulse shapes to separate distorted pulses originating from the system and other disturbances from machine partial discharges. Epoxy Mica Capacitors Installed In Motor Termination Enclosure Epoxy Mica Capacitors (80pF) Data Collection Method The online partial discharge tests are run continuously in a simple, safe and non-destructive manner based on sound principles that are recommended by manufacturers and industry standards such as IEEE Std. 1434-2014 and IEC60034-27-2: 2012. Termination Box The PDTracII automatically runs measurements in a sequence across all enabled inputs and sensitivity ranges which takes approximately 20 minutes before repeating the sequence. Iris Power PDTracII Measurement results provided by the Iris Power PDTracII instrument include: Alerts indicating high partial discharge measurements Phase resolved 3D data plots presenting raw data Summary 2D data plots of analyzed Qm results Epoxy Mica Capacitive Sensor Operating condition data Computer Installed with PDTracPro & PDView

Data Analysis and Information Output Iris Power is foremost focused on providing a clear, reliable and repeatable result that allows the user to understand the true condition of the motor or generator and to make educated decisions for operations and maintenance. The PDTracII instrument has been designed to autonomously collect partial discharge data on a continuous basis and output the relevant information needed to provide a decisive means of: Identifying Partial Discharge Severity Identifying Probable Causes of Deterioration Comparing Relative Health Across Equipment Peak Partial Discharge Magnitude Peak pulse magnitude (Qm) values are automatically evaluated by the PDTracII instrument and output to help understand the relative health of each asset. The Qm value is defined in IEEE 1434 and IEC 60032-27-2 to allow several means of comparison including the following: Trending of Qm to show any major change in the rate of deterioration of the stator winding insulation. Peak Partial Discharge Magnitude (Qm) Trend Graph Showing Increasing Rate of Partial Discharge Severity Comparison of generator condition against similar machines using the freely available Iris Partial Discharge Severity Tables which are composed of over 550,000 test results collected across most makes and sizes of machines. Machine Partial Discharge Electrical disturbances including partial discharges in the busbar or transformer as well as sparking of overhead cranes or on-site welding can create pulses similar to partial discharges. It is important to be able to understand the difference between power system disturbances and machine partial discharges to avoid false positive indications, to prevent unnecessary shut-downs and to avoid in-service failures. Phase Resolved Partial Discharge Plot showing pulse magnitude (mv) and frequency (pulses per second) by phase angle in the machine The Iris Power PDTracII is designed specifically for equipment with at least 30 m of power cable between the machine and the switchgear. If this is not the case, Iris Power recommends the use of two epoxy mica capacitors per phase and the use of the GuardII monitor or a portable TGA-B instument to ensure machine partial discharges are viewed and analyzed separately from system disturbances. Pulse Frequency 60 Low Frequency Noise Blocked by 80pF Sensor 50 40 30 20 10 High Frequency Partial Discharges Measured by PDTracII 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 40 MHz High frequency partial discharges above 40 MHz are automatically separated from low frequency noise by the PDTracII Separation of System Noise Iris Power provides a solution that separates electrical noise similar to partial discharge and other disturbances in the power system from the asset partial discharges. In cases where there is 30 m or more of power cable to the generator, high frequency system noises that resemble machine partial discharges are attenuated by the power cable. The remaining low frequency disturbances from the power system are are eliminated using the Iris Power 80 pf capacitive sensors. The sensors attenuate all low frequency electrical noises below 40MHz leaving only the machine partial discharges to be analyzed. Pulse shape is then automatically analyzed to ensure only machine partial discharges are presented in the data output. Low frequency solutions like those using 1000 pf couplers do not block these frequency ranges.

Product Overview The Iris Power PDTracII system provides automated, continuous partial discharge (PD) monitoring with configurable alarms that initiate on high partial discharge levels. PDTracII works with permanently installed epoxy mica capacitive sensors on motors, generators, dry type transformers and switchgear over 3.3 kv The PDTracII continuously collects partial discharge data to produce phase resolved plots and summary numbers (Qm and NQN) for trending and comparison. The PDTracII uses pulse shape analysis to reliably distinguish partial discharges from electrical interference (noise) in order to prevent false alarms when the monitored equipment is connected to the power system by >30 m of power cable. The test frequency range is from 40 MHz to 350MHz while working with 80 pf Epoxy Mica Capacitors (EMCs) and 2 MHz to 350 MHz with 1-2 nf capacitive couplers. Partial Discharge Pulse Measurement Frequency Bandwidth Phase Windows Pulse Amplitude Range Data Acquisition Time Resolution Ambient Sensors Recommended Sensors 0.1 MHz - 350 MHz 24 phase windows per cycle 2 mv - 34,000 mv 10 Sensitivity Range Settings 5 s per magnitude window 6 ns for EMCs Ambient Temperature Sensor Ambient Humidity Sensor Synchronization Frequency 20 Hz to 120 Hz Operating Conditions 80 pf EMC (6.9 kv - 35 kv) 3 Sensor Inputs, IEC 60034-27-2 and IEEE 1434 Compliant Operating Temperature 0 o C to 55 o C ( 32 o F to 131 o F ) Relative Humidity Up to 95% non-condensing Size 559 mm x 451 mm x 229 mm 22 x 17.75 x 9 Dimensions PDTracII Standard PDTracII Hazardous Location Options For Hazardous Locations Stainless Steel IP66 Enclosure with Available Certifications: ATEX / IECex Options 410mm W x 421mm H x 257mm D 15 W x 16.5 H x 10.14 D 550mm W x 740 mm H x 10mm D 21.5 W x 29.13 H x 10.29 D II 3G Ex na nc IIC T4 Gc in compliance with EN 60079-0:2012/A11:2013 EN 60079-15:2010 IEC 60079-0:2011 Ed. 6 IEC 60079-15:2011 Ed. 4 C-US Class I, Division 2, Groups A, B, C, D T4 Ex na nc IIC T4 Gc Class I, Zone 2, AEx na nc IIC T4 Gc based on CAN/CSA C22.2 No. 61010-1-12 CSA Std. C22.2 No. 213-16 CAN/CSA-C22.2 No. 60079-0:15 CAN/CSA-C22.2 No. 60079-15:16 ANSI/UL 61010-1, 3rd Ed ANSI/ISA-12.12.01-2015 ANSI/UL 60079-0:13 ANSI/UL 60079-15:13 INMETRO Ex na nc IIC T4 Gc In compliance with ABNT NBR ISO IEC 60079-0:2013 ABNT NBR ISO IEC 60079-15:2012 Data Download and Networking Controlling Computer Details Available On Request Networking Capability Manual Data Download Software PDTracPro and PDView PDView Advanced Edition Modbus over Ethernet (TCP/IP) USB Memory Stick Included Optional Remote Outputs Remote Inputs 6 Analog Remote Outputs: 2 Outputs Proportional to the level of PD activity (+Qm and Qm) per phase. 8 Remote Analog Inputs: Recording and Trending of equipment temperature, Voltage, Current, or Power.

IRIS POWER LP 3110 American Drive Mississauga, ON, Canada, L4V 1T2 Phone: +1.905.677.4824 Toll Free: +1.888.873.4747 Sales.iris@qualitrolcorp.com www.irispower.com QUALITROL COMPANY LLC 1385 Fairport Road Fairport, NY, USA 14450 www.qualitrolcorp.com The PDTracII is a Trademark of Iris Power LP - a Qualitrol Company VER 9-5 / 18