Accutech GP10. Wireless gauge pressure field unit

Similar documents
Accutech AP10. Wireless absolute pressure field unit

Accutech AM20. Wireless acoustic monitor field unit

Accutech DP20. Wireless differential pressure field unit

Accutech FL10. Wireless float level field unit

Accutech TC10. Wireless thermocouple temperature field unit

Accutech RT10. Wireless RTD temperature field unit

Accutech BR10. Wireless base radio

Accutech AI10 & AV10. Wireless multi-input field unit

Accutech AI10 & AV10. Wireless multi-input field unit

Technical Specification Datasheet

Accutech BR20. DIN rail mounted base radio

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

XYR 5000 Wireless Temperature Transmitters Model WT530 Specifications - Europe

Trio K-Series. License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240

Two-Wire Programmable Transmitter for:

Wireless Base Radio. Wireless Transmitters

XYR5000 Series Wireless Transmitters

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro-Pneumatic Transducers

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

ER WIRELESS TRANSMITTER

The wireless alternative to expensive cabling...

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

The Rosemount 848T Wireless Temperature Transmitter

XYR 5000 Wireless Differential Pressure Transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

LST100 Ultrasonic level transmitter for upstream oil and gas

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery

ER WIRELESS TRANSMITTER

Temperature Input Module for Zone 1 Series 9482/32

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Operating Manual. isolate501

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Analog Universal Module HART for Zone 2 Series 9468/33

MICROCOR ER WIRELESS TRANSMITTER

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications

Fisher 4200 Series Electronic Position Transmitters

02/11/2015

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

02/11/2015

CAT-1 TM Transmission Line Monitoring Systems

and ClearSCADA s custom EFM object the SOLARPack 410 becomes a complete electronic flow measurement system. Chart Recorder Replacement

High Temperature Velocity and Acceleration Sensor

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Pressure transmitter AKS 32 and AKS 33

ED701 General Industry Pressure Transmitter

Your Global Automation Partner. PT2000 Pressure Transmitter

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Positioner with HART Communication Type 3780

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

The wireless alternative to expensive cabling...

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

XYR 5000 Wireless Transmitters SIMPLE. SAFE. SECURE. Honeywell Solutions for Wireless Data Acquisiton and Monitoring

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

IP26 Series Current to Pneumatic Converter

MICROCOR WIRELESS TRANSMITTER

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Coriolis Massflowmeter

Pressure Transmitter SIL

Head mounted Temperature Transmitter TF02/TF02-Ex

Resistance thermometer Model TR30, compact design

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

PAD - Heavy Duty Differential Pressure Trasmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

WIRELESS MODBUS GATEWAY WGW410

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Relative and absolute pressure transmitter type 528

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Relative and absolute pressure transmitter type 528

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Rosemount 702 Discrete Input Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

FOUNDATION Fieldbus Junction Box

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

Transcription:

Accutech GP10 Wireless gauge pressure field unit

1 The Accutech GP10 wireless gauge pressure field unit provides pressure data in a variety of ranges from 250 to 10000 PSIG. With its integrated and highly sensitive sensor design, the product may be configured to sample and transmit updates between once per second and once per minute. Transmit rate changes can also be triggered based on events that are defined in terms of measurement limits or rates of movement. This function allows for maximisation of battery life while ensuring that all important process events are monitored. All Accutech field units automatically report field data to a centralised Accutech base radio over distances of up to 3000ft (~1000m). Each field unit is self contained, featuring an integrated 900MHz or 869MHz (license-free band), frequency hopping, spread-spectrum transceiver and antenna, and long-lasting battery that offers 3+ years of maintenance-free service (up to 10 years depending on data rates and battery options). Accutech networks are highly scalable with the possibility of 100 field units per base radio and 256 base radios per installation. Accutech field units are housed within a compact and weather-proof NEMA 4 enclosure with options for a remote sensor and remote antenna on select models. Field units are available in a wide range of certifications and are protected by an industry-leading 3-Year warranty (parts and labor).

Product Data Sheet Accutech GP10 Specifications 2 Functional Sensor Type Location Frequency Range Power Network Capacity Features Remote Configuration Interface Local Configuration Interface Sensor Accuracy Stability Output Resolution Gauge Pressure Ranges RF Characteristics Self-Diagnostics General Operating Ambient Environment Materials of Construction Power Operating Shock and Vibration Random Vibration Characteristics Electromagnetic Compatibility Safety Certifications Accutech GP10 Gauge Pressure Field Unit 900MHz and 869MHz (Europe) license-free bands Integrated battery Max. 100 field units per base radio Max. 256 base radios per network Accutech Manager, Windows TM -based GUI software, providing network-wide fault and performance-management features and field unit configuration capabilities Integrated LCD with membrane-switch buttons Display provides pressure reading and error messages, if applicable Configure sampling and RF parameters locally using membrane-switch buttons. ± 0.1% of sensor URL including the combined effects of linearity, hysteresis, repeatability and temperature (applies to standard unit without isolating seals). Combined zero and span stability: less than ± 0.1% of sensor URL per year at 21 C (70 F) 24-bit Analog to Digital conversion 250, 1000, 5000, 10000PSIG (17, 70, 350, 700BAR) 902MHz - 928MHz band (FCC/IC) 915MHz - 928MHz band (Australia) 915MHz - 921MHz band (New Zealand) 869MHz (Europe) Up to 3000ft (~1000m) typical range with obstructions The RF module in each field unit is individually tested and calibrated over the full temperature range to ensure reliable wireless operation Transmit Power: +13dBm Receive Sensitivity: -113dBm Adjacent Channel Rejection: 48dBc Alternate Channel Rejection: 62dBc Low battery alarm indicates the need to replace the battery (approximately one month warning) Contains extensive self-checking software and hardware that continuously monitors operation. Any sensor or device parameter that is out of spec is identified and reported -40 C to +121 C (-40 F to +250 F), process temperature, steady-state -40 C to +110 C (-40 F to +230 F) ambient temperature sensor -40 C to +85 C (-40 F to +185 F) electronics -20 C to +70 C (-4 F to +158 F) display (full visibility) -40 C to +85 C (-40 F to +185 F) display (with reduced visibility) Humidity: 0 to 95%, non-condensing Base Plate: 304 Stainless Steel Cover: GE Lexan, V-0 rating and UV stable Process Connection: 1/2 MNPT Self-contained power 1: C Cell Standard Accutech field units include a single C-Cell lithium battery that offers 3+ years of maintenance-free service (up to 10 years depending on data rates and battery options). Certified per IEC 60068-2-6 (vibration) and 2-27 (shock) Certified to withstand 6 g s, 15 minutes per axis from 9 500Hz Operates within specification in fields from 80 to 1,000MHz with field strengths to 30V/m. Meets EN 50082-1 General Immunity Standard and EN 55011 compatibility emissions standard North America HAZLOC: ccsaus Intrinsically Safe: Exia IIC; AEx ia IIC Class I, Div. 1, Groups A, B, C & D, T3 Class II, Div. 1, Groups E, F and G, T3 Class III, T3 Class 1, Zone 0, AEx ia IIC, T3 Class I, Div. 2, Groups A, B, C & D, T4 Class II, Div. 2, Groups F and G, T4 Class III, T4 ATEX/IECEx HAZLOC: LCIE Intrinsically Safe: Ex ia IIC T3 EMC & Radio: North America: FCC, IC Europe: CE Mark (R&TTE) Australia/New Zealand: C-Tick Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.

Product Data Sheet Accutech GP10 Model 3 Model TBUAGP T D N E J Q P N TBUAGPTJPN00S005A represents a typical part number. Type Wireless Gauge Pressure Field Unit Select: RF Module Type 902MHz - 928MHz band (FCC / IC) 915MHz - 928MHz band (Australia) 915MHz - 921MHz band (New Zealand) 869MHz (Europe) Select: Safety Rating ccsaus: Intrinsically safe protection: see specifications page ATEX/IECEx: Intrinsically safe protection: see specifications page Select: Housing & Battery Pack NEMA 4 Polycarconate Housing with 1 Cell (Available with Intrinsically Safe Rating) Select: Future Option None Select: Integral Antenna or Cable & Connector Interface 00 Integral Antenna with Antenna Cover 01 External YAGI Antenna, 6db, attached to base of unit 10 10ft. (3.05m) cable with N-Male connector for remote antenna configurations 25 25ft. (7.62m) cable with N-Male connector for remote antenna configurations S R Select: Sensor Mounting Integral Remote Sensor with 10ft. (3.05m) cable Select: Sensor Range Upper Range Overload Overload Safety Safety Limit (URL) Limit Limit PSIG (BAR) PSI (BAR) PSI (BAR) 005 5 (0.345) 10 (0.69) 30 (2) 015 15 (1) 30 (2) 500 (34) 030 30 (2) 60 (4) 500 (34) 100 100 (7) 200 (14) 500 (34) 250 250 (17) 500 (34) 1500 (103) 1K0 1000 (70) 2000 (138) 10000 (689) 2K5 2500 (170) 5000 (350) 10000 (689) 5K0 5000 (350) 12000 (827) 20000 (1279) 10K 10000 (700) 12000 (827) 20000 (1279) A Select: Junction Box No Junction Box

NEXT Accutech ENTER NEXT Accutech ENTER NEXT Accutech ENTER Product Data Sheet Accutech GP10 Dimensions 4 Internal OMNI Antenna & Integral Sensor Internal OMNI Antenna & Remote Sensor Option 6.85 (174.1mm) 6.49 (165.1mm) 1/2 NPT Male 5.80 (147.5mm) Remote YAGI Antenna & Remote Sensor Options 23.03 (584.8mm) Telemetry & Remote SCADA Solutions www.schneider-electric.com Document Number TBULM08002-37 2011 Schneider Electric. All rights reserved - August 2011