Technical Data Accessories MCCBs Ex9M.

Similar documents
UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB

Motor Protection Circuit Breaker Series 8146/5-V27

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

(1,5 modules per pole)

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Contactors and Contactor Assemblies

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h

Page 13-2 Page Page 13-7

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

AEG Low Voltage Component

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Designation CS XX(I th. Thermal Code No. Type, layout and symbol Weight Packaging CS U 10A CS U 16A

3 - Protection components Circuit-breakers

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:


Modular equipment. Presentation, standards. Standard contactors TeSys GC

Miniature Circuit Breakers B4/B6/B10, Residual Current Devices & Isolating Switches

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Overcurrent Protection / 7SJ45

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

Installation- / Monitoring technique

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

PKZ 2 Manual Motor Protectors Technical Data

Protection and safety SQZ3 phase and sequence relay

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Installation / Monitoring Technique

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R

Type: DILEM 10 G(24VDC) Article No.:

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

MCCBs and trip-free switches x160

SPECIFICATION, CONTROLS AND ACCESSORIES

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Maintenance instructions

05/09/2014

Testboy TV 416/432(A) CEE adapter*

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Technical features table for miniature circuit-breakers SH 200 Series

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

11/0 IZM circuit-breakers, IN switch-disconnectors

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Capacitor Switching Contactors

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

Smart Power Relay E I...

PQM3000R Class A network analyzer according to EN for power quality monitoring

Type: DILM40(RDC24) Article No.:

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

TCM-2 Thyristor Control Module DATA SHEET

Electronic Measuring Relays for Current, Voltage and Overfrequency

Pulse Scaler for DIN Rail Attachment

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

RX 3 ->CATALOG PAGES INSIDE. the global specialist

Controls Contactors and Contactor Assemblies Special Applications

PHOENIX CONTACT - 09/2009

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Protection Relays. U-MLEs-PLv. Ultra Line. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Electronic timer CT-SDS.22

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Components for safety applications Preventa safety modules

02/11/2015

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

27/04/2015

Technical data sheet. Technical data. Safety notes

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508

RX 3 ->CATALOG PAGES INSIDE. the global specialist

Easy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays

Supplemental Motor Protection Devices Specifications

Moeller Electric Corporation

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

RoHS. High shaft load capacity. Shock / vibration resistant

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

NS..S contactor relays - with spring terminals AC operated

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Type VDG 13 Undervoltage Relay

Room Temperature Controllers. for heating and cooling systems

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Transcription:

Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit AL21 in the MCCBs M1 and M2 Auxiliary contacts synchronous with main contacts of the circuit breaker Signal contacts active on electrical tripping of the circuit breaker (tripping signal contacts) With connection wires AX21 AL21 Contacts 1 changeover (CO) 1 changeover (CO) Contact function auxiliary signal Tested according to IEC/EN 6094-1, IEC/EN 6094-5-1 Rated op. voltage U 240/4 V AC, 110/220 V DC Rated frequency 50/60 Hz Rated op. current I e AC 5 A (240 V), 2 A (4 V) Rated op. current I e DC 1 A (110 V), 0.25 A (220 V) Rated thermal current I th 5 A Rated op. current I e, ut. cat. AC- 5 A (240 V), 2 A (4 V) Rated op. current I e, ut. cat. DC-13 1 A (110 V), 0.25 A (220 V) Rated insulation voltage U i 500 V AX21 AL21 Suitable for M1, M2 M1, M2 Connection equipped with connection wires Wiring diagrams QF QF AX11 AX14 L1 AL91 AL94 L3 AX12 L2 AL92 L4 AX21 AL21 Ordering data p. 34 63

Shunt trip releases SHT21, SHT22 It is possible to use one unit of shunt trip release SHT21 (SHT22) or one unit of undervoltage release UVT21 (UVT22) for M1 and M2 circuit breakers, respectively Can be used for remote switch off SHT21 for MCCBs of frame size M1 SHT22 for MCCBs of frame size M2 With connection wires SHT21 Tested according to IEC/EN 6094-1, IEC/EN 6094-5-1 Rated operating voltage U (according to type) 48 V AC 110 V AC 220 240 V AC 3 4 V AC 24 V DC 48 V DC 110 V DC 120 V DC 220 V DC SHT22 48 V AC 110 V AC 220 240 V AC 3 4 V AC 24 V DC 48 V DC 110 V DC 120 V DC 220 V DC Rated frequency 50/60 Hz DC Rated insulation voltage U 500 V Tripping time < 20 ms < 20 ms SHT21 SHT22 Suitable for M1, M2 M1, M2 Connection equipped with connection wires Wiring diagrams shut release coil K inside the dash internal accessories A1 A2 power SHT21, SHT22 Ordering data p. 34 64

Undervoltage releases UVT21, UVT22 It is possible to use one unit of shunt trip release SHT21 (SHT22) or one unit of undervoltage release UVT21 (UVT22) for M1 and M2 circuit breakers, respectively To switch connected breaker off in case of voltage drop UVT21 for MCCBs of frame size M1 UVT22 for MCCBs of frame size M2 With connection wires UVT21 220-240V AC UVT21 3-4V AC UVT22 220-240V AC UVT22 3-4V AC Tested according to IEC/EN 6094-1, IEC/EN 6094-5-1 Rated operating voltage U n 220 240 V AC 3 4 V AC 220 240 V AC 3 4 V AC Rated frequency 50/60 Hz Rated insulation voltage U 500 V Tripping time < 20 ms < 20 ms < 20 ms < 20 ms Making treshold 85 % U n 85 % U n 85 % U n 85 % U n Tripping treshold 35 % U n 35 % U n 35 % U n 35 % U n UVT21 UVT22 Suitable for M1 M2 Connection equipped with connection wires Wiring diagrams X P1 P2 P3 P4 P5 P6 AC 400V AC 2V AC 110V UVT21, UVT22 Ordering data p. 35 65

Technical Data Accessories MCCBs Ex9M. Can be locked in ON and OFF position with up to three padlocks (not in a scope of delivery) 3.5 RHD21 for MCCBs of frame size M1 RHD21 IEC/EN 6094-3 IP40 1 5.6 3.5 Suitable for RHD21 5 RHD22 M1 M2 connected breaker status ON-OFF-TRIP grey Dimensions RHD21 5.6 66 1 Ordering data p. 35 1 RHD22 5 3.5 Toggle colour directly onto breaker Mounting 3 Indication IK0 Mechanical shock resistance Degree of protection 1 RHD22 Tested according to 1.2 RHD22 for MCCBs of frame size M2 5 Scope of delivery: mechanism block, rotary handle Rotary handle for direct mounting onto breaker 1 Direct rotary handles RHD21, RHD22 5 3.5

Technical Data Accessories MCCBs Ex9M. Extended rotary handles ERH21, ERH22 Rotary handle with etension shaft Scope of delivery: mechanism block, extension shaft, rotary handle Can be locked in ON and OFF position with up to three padlocks (not in a scope of delivery) Extension shaft can be shortened RHD21 for MCCBs of frame size M1 RHD22 for MCCBs of frame size M2 5 ERH21 ERH22 IEC/EN 6094-3 Degree of protection IP54 Tested according to Length of the extension shaft ERH21 ERH22 M1 M2 0 mm Indication Mounting grey Toggle colour Dimensions 5.6 1.3 1.3 1.2 1.2 1 5.6 ERH21 5 0 mm IK08.5 connected breaker status ON-OFF-TRIP directly onto breaker Mechanical shock resistance 1.2 Suitable for 1.3 3.5 5.6 5.6 6 Ordering data p. 36 1

NN Technical Data Accessories MCCBs Ex9M. Extended rotary handles ERH21, ERH22 Dimensions ERH22 NN NN Ordering data p. 36 68

Remote motor operators MOD21, MOD22 Motor drives for electrical and remote control of MCCBs MOD21 for MCCBs of frame size M1 MOD22 for MCCBs of frame size M2 MOD21 MOD22 Tested according to IEC/EN 6094-1, IEC/EN 6094-5-1 Rated operating voltage U s (according to type) 2 V AC 110 V AC 220 V DC 110 V DC 24 V DC 2 V AC 110 V AC 220 V DC 110 V DC 24 V DC Rated frequency 50/60 Hz DC Power consumption 0 VA 0 VA Total time to switch ON 5 ms 5 ms Total time to switch OFF 500 ms 500 ms Min. pulse duration for ON 0 ms 0 ms Min. pulse duration for OFF 0 ms 0 ms MOD21 MOD22 Suitable for M1 M2 Terminals lift lift Terminal capacity 0.2 1.5 mm 2 0.2 1.5 mm 2 Mechanical service life 10 000 operation cycles 10 000 operation cycles Maximum frequency of switch. cycles 120 operating cycles per hour 120 operating cycles per hour Wiring diagram MOD21, MOD22 P1 P2 S1 S2 S3 S4 U c Power supply UC ON OFF Ordering data p. 36 69

Remote motor operators MOD21, MOD22 Dimensions MOD21 90 81 190.4 16 11.5 88 118.5 88 0.5 88 MOD22 105 81 200 18 0.5 88 Ordering data p. 36 0