ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Similar documents
ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

WD WD7000 Series

Installation Instructions FE6800 Series Multi-Point Lock

1530(F) Mortise Exit Devices Installation Instructions

Installation Instructions

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

MORTISE LOCK INSTALLATION INSTRUCTIONS

ED8000 Series. Pushpad Exit Devices Parts Manual

INSTALLATION INSTRUCTIONS CRL JACKSON

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Installation Instructions For Profile Series v.g1 Exit Device

7130(F) Series Mortise Exit Devices Installation Instructions

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

1500(F) Rim Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

ED5200(A) Series Rim Exit Devices

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

Installation Instructions

98/ Customer Service # Dogging Key (use to lock down pushbar)

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

ED3000 Series. Exit Device Parts Manual

Passage Mortise Lock Set Lever to Lever

Installing Your Electronic Deadbolt

Installation Instructions for 45H & 47H Mortise Locks

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Entry Mortise Lock Set Lever to Lever

Melamine Plastic Laminate. Toilet Partition Installation Manual

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

Hardware Installation. Do this first:

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Entry Mortise Handleset

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

8800 Series Mortise Lockset Knob, Lever, Reflections and Security Trims Installation Instructions

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

LATCHBOLT FILLER PLATE ASA FILLER PLATE A. SINGLE DOOR B. DOUBLE DOOR WITH MULLION C. DOUBLE DOOR WITHOUT MULLION END COVER MOUNTING BRACKET

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

This is a printable pdf document. For Smartphone-friendly version, tap or click here.

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

FOLDING DOOR INSTRUCTIONS

OFFSET PIVOTS STOREFRONT HARDWARE

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

BEFORE STARTING INSTALLATION

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

DC3210. Recommended Closer Size

INTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:

Installation Instructions For The 8850FL Series Mortise eboss

Installation Instructions

Installation Instructions

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

MORTISE LOCK INSTALLATION INSTRUCTIONS

Installation Instructions ENGLISH

INSTALLATION INSTRUCTIONS

Bravura. UL Listed Commercial Locksets FORGED. Designs from Great European Homes. Fall 2009

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

WOOD DOOR INSTALLATION

Gared Pro-S Portable Backstop

INSTRUCTIONS FOR HIT TEMPLATE FOR ALARM LOCK DL3500 MORTISE LOCK

Installation Instructions. Installation Type

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

SSRLS-3 / SSRLU-3 Installation Instructions

MobileTrak5 Installation Instructions

FLAVESCO ELEVATOR GUARDING USER MANUAL

Installation Instructions. Installation Type

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

1800 Series. Flatbar Exit Devices. An ASSA ABLOY Group brand

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

Door Hardware Installation Instructions. For Assistance Call:

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

Item # Thanks for shopping with Improvements!

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

EUROLINE CLASSIC SOLID SURFACE Installation Instructions

M O R T I S E L O C K S

INSTRUCTION SHEET U19

Transcription:

Installation Instructions MP9800 Series Multi-Point Lock MP9800 Series Multi-Point Lock, the global leader in door opening solutions 1 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

Table of Contents 1 2 3 4 5 Warnings... 2 General Description... 3 MP9800 Series Multi-Point Lock Installation Instructions...4-6 M55 Series Installation Instructions...7-9 Classroom Intruder (*52) Function Series...10-11 1 Warnings Changes or modifications to this unit could void the user s authority to operate the equipment. Important: Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (authority having jurisdiction) to ensure compliance with all applicable codes and ratings Copyright 2016 Corbin Russwin Inc., an Group company. 2 of 12, the global leader in door opening solutions

2 General Description The MP9800 Series Multi-Point Lock is ideal for security applications and joins the Corbin Russwin line of multi-point door security solutions. Eliminating the need for automatic flushbolts and coordinators, the MP9800 Series provides flexibility, simplicity, strength, durability, aesthetics and innovation and is perfect for a wide variety of applications including conference rooms, commercial office buildings, convention centers, upscale condominiums and residential applications, medical and educational institutions where exit devices are not required. MP9800 Series Vertical Rod locks are available for aluminum, wood and metal doors. Single point top latching can also be specified, eliminating the bottom strike and the additional installation work required with a bottom bolt. The single point lock is specified with the M55- option. Rods are retracted by dual mounted controls with a variety of functions available. The MP9800 Series is available for fire rated openings for wood or metal doors. Thermal pin requirements for fire rated doors: - Double doors with two point latching on each do not require thermal pins - Double doors with single point latching (M55-) on each require a total of 2 thermal pins, one thermal pin (supplied) for each lock See the Corbin Russwin MP9800 Series Catalog for more information, call 1-800-438-1951, or visit www.corbinrusswin.com Tools Required - (Same for all Series Products) Phillips screw driver Slotted screw driver Drill with bits, the global leader in door opening solutions 3 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

3 MP9800 Series Installation Instructions Note: For auxiliary controls and MELR (Electric Latch Retraction) Option: Ensure all required door preparation has been completed prior to hardware installation. Figure 1: Handing A) Door Preparation 1. Verify Hand and Bevel of Door -(Figure 1) Check hand of door. The Multi-Point lock may be handed. Door should be fitted and hung. Verify box label for size of the Multi-Point lock, function and hand. Change handing if necessary. LH- Left Hand Door 2. Door Preparation If door is not pre-drilled, prepare door according to template T31243. Refer to templates at www.corbinrusswin.com. RH- Right Hand Door 3. Hardware Supplied: AA Top Chassis & Bottom Plate Mounting Screw- (6) #12-2" Phillips Flat Head Wood Screws Lever Mounting Screw- (2) 1/4" -20 x 3" Phillips Oval Head Machine Screws Mounting Screw- (2) #10 x 1-1/4" Phillips Flat Head Wood Screws Bottom Strike Mounting Screw- (2) 1/4" -20 x 2" Phillips Head Machine Screws and (2) Anchor Nuts LHRB- Left Hand Reverse Bevel RHRB- Right Hand Reverse Bevel Copyright 2016 Corbin Russwin Inc., an Group company. 4 of 12, the global leader in door opening solutions

3 MP9800 Series Installation Instructions - Continued B) Installation 1. Measure gap between top of door & frame and bottom of door & floor before removing door from hinges. (See Steps 5-6). 2. Attach inner chassis (B) to door with (2) #10 x 1-1/4" Phillips flat head wood mounting screws (). (See Figure 2). 3. Screw top rod (A) and bottom rod (D) into inner chassis (B) from top and bottom of door. 4. Place trim backplates between lever trim and door surfaces with unfinished side toward the door surface. Insert spindle thru 1-1/4" hole. Spindle cams must be UNDER inner chassis platform (C). Insert lever trim mounting screws, 1/4"-20 x 3" () through trimplate and tighten. 5. Use inside trim to adjust top bolt and rod assembly (A). - For 1/8" GAP OR LESS between top of door and door frame, rotate bolt even with top of door. - For 1/8" GAP OR GREATER between top of door and door frame, rotate bolt to gap space minus 1/8" above door. B A Figure 2: MP9800 x MPWD Assembly Top Bolt & Rod Assembly Outside Lever (2) 1/4" - 20 x 3" Lever Mounting Screws Inside Lever Inside Spindle Cam Outside C Platform 6. Use inside trim to adjust bottom bolt and rod assembly (D). - For 1/8" GAP OR LESS between door bottom and high point of floor, rotate bolt to make even with bottom of door. (2) #10 x 1-1/4" Phillips Flat Head Wood Screws- Mounting Screws D Bottom Bolt & Rod Assembly - For 1/8" GAP OR GREATER between door bottom and high point of floor, rotate bolt to gap space minus 1/8" below door., the global leader in door opening solutions 5 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

3 MP9800 Series Installation Instructions - Continued B) Installation- Continued 7. Slide top chassis (E) over top bolt (A) on top of door. Secure with (4) #12-2" flat head wood screws (AA). (See Figure 3). 8. Install bottom plate (H) over bottom bolt (D) on bottom of door. Secure with (2) #12-2" flat head wood screws (AA). 9. Install door into the frame using hinges. 10. Attach 764F577 Top Strike to door frame, (2) #10-24 x 1/2" Phillips flat head machine screws (Reference template T31241). (See below). 11. Attach bottom strike to floor under bottom bolt (Reference template T31241). 764F577 Bottom Strike, MP9800 x MPWD or 764F587 Bottom Strike, MP9800B x MPWD. 12. BEFORE CLOSING DOOR, ensure the following: (Adjust bolts per Step 5 as needed): a) Either lever retracts both bolts. b) Bolts stay retracted (in hold back). c) Bolts release when door closes; button inside top of door hits frame. d) Bolts engage strikes by 1/4"- 5/16". E A AA (4) #12-2" Flat Head Wood Screws Top Chassis Top Bolt & Rod Assembly Outside Lever B C) Strikeplates Lever Mounting Screws Inside 764F577 Top Strikeplate 764F577 Top Strike (2) #10-24 x 1/2" Phillips Flat Head Machine Screws Outside 764F587 Bottom Strikeplate 764F587 Bottom Strike STRIKE PACK, MP9800 x MPWD: 764F567 Strike (2), Top and Bottom strikes. Top: #10-24 x 1/2" PH FL HD MS (2); Bottom: 1/4-20 x 2" PH FL HD MS (2) and anchor nuts (2) Mounting Screws Figure 3: MP9800 x MPWD Assembly D Bottom Bolt & Rod Assembly STRIKE PACK, MP9800B x MPWD: 764F577 Top Strike (1), #10-24 x 1/2" PH FL HD MS (2); 764F587 Bottom Strike (1), 1/4-20 x 2" PH FL HD MS (2) and anchor nuts (2) H Bottom Plate AA (2) #12-2" Flat Head Wood Screws Copyright 2016 Corbin Russwin Inc., an Group company. 6 of 12, the global leader in door opening solutions

4 M55 Series Installation Instructions (Less Bottom Rod) Note: For auxiliary controls and MELR (Electric Latch Retraction) Option: Ensure all required door preparation has been completed prior to hardware installation. MP9800B Wood Door x M55 Fire-rated locks require installation of thermal pins for fire rating. Pairs of doors ONLY. NOT AVAILABLE for single door application. Figure 4: Handing A) Door Preparation 1. Verify Hand and Bevel of Door -(Figure 4) LH- Left Hand Door Check hand of door. The Multi-Point lock may be handed. Door should be fitted and hung. Verify box label for size of the Multi-Point lock, function and hand. Change handing if necessary. 2. Door Preparation If door is not pre-drilled, prepare door according to template T31243. Refer to templates at www.corbinrusswin.com. RH- Right Hand Door 3. Hardware Supplied: AA Top Chassis Mounting Screw- (4) #12-2" Phillips Flat Head Wood Screws Lever Mounting Screw- (2) 1/4" -20 x 3" Phillips Oval Head Machine Screws LHRB- Left Hand Reverse Bevel Mounting Screw- (2) #10 x 1-1/4" Phillips Flat Head Wood Screws RHRB- Right Hand Reverse Bevel, the global leader in door opening solutions 7 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

4 M55 Series Installation Instructions (Less Bottom Rod) - Continued B) Installation 1. Measure gap between top of door & frame and bottom of door & floor before removing door from hinges. (See Steps 5-6). 2. Attach inner chassis (B) to door with (2) #10 x 1-1/4" Phillips flat head wood mounting screws (). (See Figure 5). 3. Screw top rod (A) into inner chassis (B) from top of door. 4. Place trim backplates between lever trim and door surfaces with unfinished side toward the door surface. Insert spindle thru 1-1/4" hole. Spindle cams must be UNDER inner chassis platform (C). Insert lever trim mounting screws, 1/4"-20 x 3", () through trimplate and tighten. 5. Use inside trim to adjust top bolt and rod assembly (A). - For 1/8" GAP OR LESS between top of door and door frame, rotate bolt even with top of door. - For 1/8" GAP OR GREATER between top of door and door frame, rotate bolt to gap space minus 1/8" above door. B Figure 5: MP9800 x MPWD x M55 Assembly A Top Bolt & Rod Assembly Outside Lever (2) 1/4" - 20 x 3" Lever Mounting Screws Inside Lever Inside Outside C Platform (2) #10 x 1-1/4" Phillips Flat Head Wood Screws- Mounting Screws Copyright 2016 Corbin Russwin Inc., an Group company. 8 of 12, the global leader in door opening solutions

4 M55 Series Installation Instructions (Less Bottom Rod) - Continued B) Installation- Continued 6. Slide top chassis (E) over top bolt (A). Secure with (4) #12-2" flat head wood screws (AA). (See Figure 6). 7. Install door into the frame using hinges. 8. Attach 764F577 Top Strike to door frame, (2) #10-24 x 1/2" Phillips flat head machine screws (Reference template T31241). (See below). 9. BEFORE CLOSING DOOR, ensure the following: (Adjust top bolt per Steps 5 as needed): a) Either lever retracts bolt. b) Bolt stays retracted (in hold back). c) Bolt releases when door closes; button inside top of door hits frame. d) Bolt engages strike, 1/4"- 5/16". Figure 6: MP9800 MPWD x M55 Assembly E AA Top Chassis (4) #12-2" Flat Head Wood Screws- Top Chassis Mounting Screws C) Strikeplate 764F577 Top Strikeplate 764F577 Top Strike, Strike Pack A Top Bolt & Rod Assembly (2) #10-24 x 1/2" Phillips Flat Head Machine Screws Outside Lever B Inside Lever Mounting Screws Outside Mounting Screws, the global leader in door opening solutions 9 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

MP9800 Series Multi-Point Lock 5 M55 Series CLASSROOM FUNCTION Installation Instructions A) Installation 1. Through bolt the trim as described in Step 4 on Page 8. Ensure that the inside cylinder tailpiece engages the auxiliary cam on the outside trim. Figure 7: MP9800 Wood Door Assembly 2. Check for smooth locking and unlocking via cylinder on both sides of the door. 3. Remove components shown below in order to replace outside cylinder. 4. Reinstall removed components after cylinder is installed. Hardware Supplied: Figure 8: MP9800 Wood Door Assembly AA Top Chassis Mounting Screw- (4) #12-2" Phillips Flat Head Wood Screws Lever Mounting Screw- (2) 1/4" -20 x 3" Phillips Oval Head Machine Screws Mounting Screw- (2) #10 x 1-1/4" Phillips Flat Head Wood Screws Auxiliary Cam DD Aux Control Mounting Screw- (2) 10-24 x 2-1/8" Phillips Oval Head Machine Screws Inside Cylinder Tailpiece Copyright 2016 Corbin Russwin Inc., an Group company. 10 of 12, the global leader in door opening solutions

5 M55 Series CLASSROOM FUNCTION Installation Instructions - Continued B) Auxiliary Control Product Installation On Wood Door 1. Slide the extension, with reduced diameter facing down, through the cut out for the inner chassis on the door. 2. Insert inner chassis into the door cutout and insert reduced end of extension in top threaded bushing on inner chassis. Secure with (1) #8-32 x 7/16" Phillips oval head machine screw. (Only on aux control devices), (See Figure 9). FOR AUXILIARY CONTROL: 3a. Install plate onto extension going from the outside of door through the cutout. FOR MELR CONTROL: 3b. Install plate onto extension going from the inside of door through the cutout. 4. Attach inner chassis mounting plate to inner chassis assembly with (2) #10 x 1-1/4" flat head screws (). 5. Attach Auxiliary Control to door with (2) #10-24 x 2-1/8" Phillips oval head machine screws (DD). (Only on aux control devices). Figure 9: MP9800 Wood Door Assembly Extension Plate Auxiliary Control Device Lever Mounting Screws (2) 1/4" -20 x 3" Phillips Oval Head Machine Screws Inside Lever DD (2) #10-24 x 2-1/8" Phillips Oval Head Machine Screws Inside Outside Lever Assembly Outside Mounting Plate (2) #10 x 1-1/4 Phillips Oval Head Machine Screws (1) #8-32 x 7/16" Phillips Oval Head Machine Screws, the global leader in door opening solutions 11 of 12 Copyright 2016 Corbin Russwin Inc., an Group company.

Corbin Russwin 225 Episcopal Road Berlin, CT 06037 Phone: 800-810-WIRE Fax: 800-447-6714 corbinrusswin.com Copyright 2016 Corbin Russwin Inc., an Group company. 12 of 12, the global leader in door opening FM436 solutions (08/16)