Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015

Similar documents
Νέες Τεχνολογίες Σάρωσης Σώματος για Ασφαλείς Διελεύσεις. 5o SECURITY PROJECT Μαΐου 2017 Αθήνα, Divani Caravel

Test & Measurement. Technical Information. R&S ZV-WR10 / -WR12 / -WR15 Calibration Kits

Unique Applications of microwave VNA technology. Ben Maarleveld - Sales Manager T&M - Rohde & Schwarz Benelux B.V.

A True Differential Millimeter Wave System with Port Power Control. Presented by: Suren Singh

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

THz Vector Network Analyzer Development & Measurements

Beamforming measurements. Markus Loerner, Market Segment Manager RF & microwave component test

Testing Millimeter-Wave Mixers Using Converters of the R&S ZVA Family

Waveguide Calibration with Copper Mountain Technologies VNA

R&S NRP Power Meter Family Specifications

Millimeter Wave Solutions from R&S

Testing S-Parameters on Pulsed Radar Power Amplifier Modules

Vector Network Analyzer Application note

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

High Performance, Broadband Network Analysis Solutions

Vector Network Analyzer

Calibration and Accuracy in Millimeter Systems. Keith Anderson

R&S NRP USB and LAN Power Sensors Specifications

PLANAR 814/1. Vector Network Analyzer

E-band and mmwave Components & Sub-Assemblies testing Challenges New Technology. VNA Roadshow Budapest 17/05/2016

Optoelectronic Components Testing with a VNA(Vector Network Analyzer) VNA Roadshow Budapest 17/05/2016

Configuration of PNA-X, NVNA and X parameters

Technologies Vector Reflectometers

Ultra High Frequency Measurements

Network Analysis Basics

Vector Network Analysis

Emission of mm-wave and THz Scanners

PLANAR S5048 and TR5048

Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense

Antenna Measurement using Vector Network Analyzer. Jong-hwan Keum Agilent Technologies

SERIES PLS PHASE LOCKED SYNTHESIZER. FEATURES: Small Size, Low Cost, Simple to use Low Phase Noise Auto-sensing Internal or External 10MHz Reference

Spectrum and signal analyzers for every requirement an overview

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

LA Techniques Ltd

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

R&S ZVT Vector Network Analyzer Specifications

Spurious and Stability Analysis under Large-Signal Conditions using your Vector Network Analyser

Keysight Technologies Gustaaf Sutorius

The path from 4G to 5G: Technology development from the test & measurement perspective. Dr. Taro Eichler. 5G Tokyo Bay Summit July 23 rd, 2015

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

R&S NRP-Zxx Power Sensors Specifications

5 ESSENTIAL HINTS TO IMPROVE Millimeter-wave Network Analysis

FieldFox Handheld Education Series Part 3: Calibration Techniques for Precise Field Measurements

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

RF power measurement in. three-mixer method

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

EXTEND YOUR REACH. Copper Mountain Technologies USB VNAs. S-parameter measurement solutions from 9 khz to 110 GHz Measured parameters from S 11

Panel Session: 5G Test and Measurement

Millimeter Signal Measurements: Techniques, Solutions and Best Practices

Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs)

Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 1.1 THz. Technical Overview

Keysight Technologies Techniques for Precise Cable and Antenna Measurements in the Field

PLANAR R54. Vector Reflectometer KEY FEATURES

International Journal of Engineering & Computer Science IJECS-IJENS Vol:13 No:03 1

Technical Information

Holography Transmitter Design Bill Shillue 2000-Oct-03

Novel Method for Vector Mixer Characterization and Mixer Test System Vector Error Correction. White Paper

Enabling autonomous driving

S3602A/B Vector Network Analyzer Datasheet

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer

Harmonic Mixers And their application with Spectrum Analysers Application Note Revision: February 2009

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Agilent 8360B/8360L Series Synthesized Swept Signal/CW Generators 10 MHz to 110 GHz

Calibration and Validation for Automotive EMC

Optical Delay Line Application Note

[APP NOTE TITLE] Application Profile. Challenges

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Impact of mm-wave Range and Large Bandwidth on RF System Design. R&S Taiwan Feiyu Chen

FEASIBILITY STUDY ON FULL-DUPLEX WIRELESS MILLIMETER-WAVE SYSTEMS. University of California, Irvine, CA Samsung Research America, Dallas, TX

EXTEND YOUR REACH GHz 60-90GHz GHz

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

PM Series Microwave Power Calibration System

CobaltFx Series EXTEND YOUR REACH. Frequency Extender System from. Frequency bands from: GHz, GHz, GHz

Improved Measurement of Passive Intermodulation Products

R&S ZVT Vector Network Analyzer Specifications

Banded Milimeter Wave Network Analysis TECHNICAL OVERVIEW

Agilent Technologies Gli analizzatori di reti della serie-x

S3602C Vector Network Analyzer Datasheet

Confidence. on the Cutting Edge. Vector Network Analyzer Portfolio Brochure. In the Lab On the Manufacturing Floor In the Field. Anritsu Since 1895

Ultra Wideband Indoor Radio Channel Measurements

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

Overcoming Mixer Measurement Challenges

Improving Amplitude Accuracy with Next-Generation Signal Generators

Frequency Extender Systems Frequency bands from: GHz, GHz, GHz, GHz FEV Frequency Extender System in Collaboration with

E/O and O/E Measurements with the 37300C Series VNA

Frequency Extension Systems Frequency bands from: GHz, GHz, GHz, GHz FEV Frequency Extenders in collaboration with

Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 1.1 THz. Technical Overview

Compact MIMO Antenna with Cross Polarized Configuration

X-Parameters with Active and Hybrid Active Load Pull

Double-Ridged Waveguide Horn

Broadband Millimeter-wave FMCW Radar for Imaging of Humans

SAGE Millimeter, Inc.

Exercise 5: Power amplifier measurement

Keysight Technologies UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Microwave/Millimeter-Wave RCS Test System

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

EXHIBIT 10 TEST REPORT. FCC Parts 2 & 24

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Transcription:

Amplifier Characterization in the millimeter wave range Tera Hertz : New opportunities for industry 3-5 February 2015

Millimeter Wave Converter Family ZVA-Z500 ZVA-Z325 Y Band (WR02) ZVA-Z220 J Band (WR03) ZVA-Z170 G Band (WR05) ZVA-Z140 D Band (WR06) ZVA-Z110E F Band (WR08) ZVA-Z110 ZVA-Z75 ZVA-Z90 E Band (WR12) W Band (WR10) Manual Attenuator Electronic Attenuator V Band (WR15)

Converter block diagram (ZVA-Z110, WR10 band) REF LNA +20dB Legend: Waveguide WR10 N = 8 Coaxial (PC3,5/SMA) Attenuator (manual) M = 6 TEST PORT x3 x2 RF LO N = 8 +10dB LNA +20dB MEAS

Rohde & Schwarz ZVA-Z110 RF, LO, IF parameters ı Source Input (from VNA): Frequency Range: 12.5 GHz to 18.333334 GHz (x6) Input power range: +4 dbm to +10 dbm ı Local Oscillator Input (from VNA/ext source) Frequency Range: 9.3375 GHz to 13.74875 GHz (x8) Input power Range: +5 dbm to +10dBm ı Measurement/Reference Output (to VNA) Frequency Range: 10 MHz to 300 MHz

Material measurements in the millimeter wave range 5

Amplifier Characterization Compression point measurement, e.g. 1dB CP ı Requires power sweep capability ı For accurate compression measurements we need A flat input power @ DUT input A defined (calibrated) power level @ DUT input ı Consequence : Power calibration is a must 6

ZVA-Z110E with electronic power control ı 75 to 110GHz with electronic power control ı 0 to 25 db attenuation ı Allows power sweep and compression point measurement on amplifiers

Electronic power control Full automatic compression point measurement at 110 GHz To R&S ZVA-Z110E 25dB Electronic Power Sweep Range Option R&S ZVA-B8

Power Sweep by RF input variation Example WR10 band ı Power sweep range of 70dB by RF input power variation ı Frequency dependency can be calibrated out by software tool Output power relative to max output power / db @ 75, 80, 85, 90, 95, 100, 105 and 110 GHz RFin power / dbm

Power Calibration in the millimeter wave range

Precise power calibration up to 110GHz Unique power measurements from DC up to 110GHz with 1.0mm connector First millimeterpower sensor that is traceable to a national metrology institute S-Parameters of waveguide transition can be loaded directly into sensor for accurate power measurements USB interface means the power sensor can be used directly with the ZVA or PC running the free NRP analysis software. Lowest uncertainty 0.040 to 0.318dB Highest Linearity 0.010dB @110GHz 30% faster than competition

Power calibration above 110GHz Compatibility for power measurements up to 220GHz with the ELVA DPM power meter. Compatibility with VDI (Erickson) PM4/5 Calorimeter power meter for use from 75GHz to 2 THz. Flexible ZVA external device implementation allows customer developed drivers

Power Calibration on the Wafer WR10 Wafer

Challenges for accurate Power Levels On-Wafer Goal : Power calibration in the reference plane of the DUT (amplifier) Problem : No access with coaxial power meter possible Solution: ı Characterization of the S-parameter between coaxial interface and the wafer prober tip ı Correction of the coaxial power calibration with this loss list

Power Correction with Loss List Coax plane Loss list Wafer

Power Calibration in Reference Plane on the Wafer 1st Step: UOSM calibration to characterize the connection between coaxial interface and onwafer reference plane Power loss list for each port Alternatively Delta Calibration between coaxial plane and On-Wafer plane 1 mm Match ISS-Match Unknown Through 2nd Step: Power calibration at the coaxial interfaces using the power loss list from the 1st step.

Millimeter Wave Imaging Systems Phase Error Sensitivity Tera Hertz : New opportunities for industry 3-5 February 2015

Technology choices + technology reuse + sufficient RF power + high bandwidth + mm resolution + good penetration + 3D Images + Compact Planar 2D-Array + feasible + Reduce cost + Reduce power + faster E-Band Multistatic sparse array + high dynamic range + indoor operation Active system Digital- Beamforming + synthetic focusing + high flexibility + adjustable illumination 18

Multistatic imaging - Focusing 2D-Array x z Tx Rx y Reconstruction in space domain 19

Principle of Operation ı Person is illuminated by microwaves with very low intensity (No X-rays non ionizing radiation) ı Waves penetrate the clothing (but not the skin) ı Scanner detects the reflected (backscattered) signal from the skin or concealed objects ı Unique technique analysing reflections from floor mirror ı Automatic evaluation and analysis of image data by an automatic detection software (algorithm) metallic and non-metallic plastics ceramics explosives liquids and gels powder Incident wave Reflected wave 20

Technical Overview Panel Cluster 94 receive antennas ı Aperture 2 m x 1 m ı 3008 Tx & 3008 Rx elements in 32 Clusters ı Data acquisition time 16 ms for QPS100 (per scan) 64 ms for QPS200 (single) ı Frequency 70 to 80 GHz (λ 4 mm) 94 transmit antennas ı High resolution < 2 mm ı Image dynamic range > 30 db ı Processing time 7 sec (QPS100, result of front scan) 10 sec (QPS100, complete result) 7 sec (QPS200, complete result) 21

System Block Diagram 22

Digital Signal Processing Chain digitized IF signals DDC, lowpass filter correct for system drift system error correction image reconstruction automatic detection algorithm detection result 23

Sources of Noise ı Various sources of errors within the system ı Dominant errors: Thermal noise of receiver Phase noise of signal source Temperature drift (phase drift of received signal), compensated by referencing Antenna crosstalk, compensated by system error correction ı Noise affects performance of compensation 24

Cross-coupling ı As a systematic signal, residual cross-coupling shows up as artifact within the microwave image 25

Test scenario ideal image ı Resolution test chart ı Dynamic range test ( bed of nails ) ı Heavy averaging used for best available data quality more than 40 db noise and artifact free image dynamic range ı This data is used as reference data set and modified by adding systematic and random phase errors ı The modified data are reconstructed and effects of phase errors on image quality are examined 26

Test scenario systematic phase drift added (e.g. temperature drift) ı Systematic phase drift of 20 degree added to raw data ı Cross-coupling is not compensated completely shows up as artifact ı Dynamic range is decreased to 27 db ı When omitting channels with high cross-coupling from adjacent transmitters, dynamic range is 33 db complete dataset high-cc omitted 27

Systematic Phase Errors - Summary ı Normally the cross coupling between the antennas is calibrated out (Match calibration) ı But if temperature drift (= phase error, phase drift) happens the cross coupling can not be fully eliminated ı Consequence : Artifacts come up in the picture ı Measures : Omitting channels with high cross coupling 28

Test scenario random phase added (e.g. source phase noise) complete dataset ı Random phase drift, standard deviation 20 degree added to raw data ı Random error no systematic artifacts, but significant increase in noise level ı Dynamic range is decreased to 33 db ı When omitting channels with high cross-coupling from adjacent transmitters, dynamic range is 36 db high-cc omitted 29

Random Phase Errors - Summary ı Noise level increases ı No artifacts ı Consequences : Decrease in dynamic range Unclear picture ı Measures : Reference channels near Tx/Rx antennas Omitting channels with high cross coupling 30

Other application areas for microwave imaging Non-Destructive Test with 3D-Pictures (QPS100) 31

Thank you for your attention 1950 : World s first Vector Network Analyzer - made by R&S Direct display of S-Parameters in a complex plane > 50 years of experience in network analysis