A new prime-focus corrector for paraboloid mirrors

Similar documents
Waves & Oscillations

Three-Mirror Anastigmat Telescope with an Unvignetted Flat Focal Plane

Option G 2: Lenses. The diagram below shows the image of a square grid as produced by a lens that does not cause spherical aberration.

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Ch 24. Geometric Optics

Geometric optics & aberrations

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Notation for Mirrors and Lenses. Chapter 23. Types of Images for Mirrors and Lenses. More About Images

Optics Practice. Version #: 0. Name: Date: 07/01/2010

25 cm. 60 cm. 50 cm. 40 cm.

Laboratory 7: Properties of Lenses and Mirrors

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

Chapter 23. Mirrors and Lenses

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

OPTICAL IMAGING AND ABERRATIONS

Magnification, stops, mirrors More geometric optics

Chapter 23. Mirrors and Lenses

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

COURSE NAME: PHOTOGRAPHY AND AUDIO VISUAL PRODUCTION (VOCATIONAL) FOR UNDER GRADUATE (FIRST YEAR)

Lens Design I. Lecture 5: Advanced handling I Herbert Gross. Summer term

Chapter 18 Optical Elements

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Chapter 23. Geometrical Optics: Mirrors and Lenses and other Instruments

CH. 23 Mirrors and Lenses HW# 6, 7, 9, 11, 13, 21, 25, 31, 33, 35

Chapter 36. Image Formation

Chapter 34 Geometric Optics

Lecture 3: Geometrical Optics 1. Spherical Waves. From Waves to Rays. Lenses. Chromatic Aberrations. Mirrors. Outline

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

Converging Lenses. Parallel rays are brought to a focus by a converging lens (one that is thicker in the center than it is at the edge).

1.1 Singlet. Solution. a) Starting setup: The two radii and the image distance is chosen as variable.

Chapter 9 - Ray Optics and Optical Instruments. The image distance can be obtained using the mirror formula:

Aberrations of a lens

Some lens design methods. Dave Shafer David Shafer Optical Design Fairfield, CT #

Chapter 36. Image Formation

System/Prescription Data

Chapter 23. Light Geometric Optics

Astronomy 80 B: Light. Lecture 9: curved mirrors, lenses, aberrations 29 April 2003 Jerry Nelson

Lecture Outline Chapter 27. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Introduction. Geometrical Optics. Milton Katz State University of New York. VfeWorld Scientific New Jersey London Sine Singapore Hong Kong

SIMPLE LENSES. To measure the focal lengths of several lens and lens combinations.

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

TOPICS Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization

Optical Design with Zemax

Chapter Ray and Wave Optics

Lens Design I. Lecture 10: Optimization II Herbert Gross. Summer term

October 7, Peter Cheimets Smithsonian Astrophysical Observatory 60 Garden Street, MS 5 Cambridge, MA Dear Peter:

Spherical Mirrors. Concave Mirror, Notation. Spherical Aberration. Image Formed by a Concave Mirror. Image Formed by a Concave Mirror 4/11/2014

Exam Preparation Guide Geometrical optics (TN3313)

Practice Problems (Geometrical Optics)

2. The radius of curvature of a spherical mirror is 20 cm. What is its focal length?


ECEN 4606, UNDERGRADUATE OPTICS LAB

Classical Optical Solutions

Activity 6.1 Image Formation from Spherical Mirrors

Optical Zoom System Design for Compact Digital Camera Using Lens Modules

Sequential Ray Tracing. Lecture 2

Cardinal Points of an Optical System--and Other Basic Facts

UNIVERSITY OF NAIROBI COLLEGE OF EDUCATION AND EXTERNAL STUDIES

Chapter 29/30. Wave Fronts and Rays. Refraction of Sound. Dispersion in a Prism. Index of Refraction. Refraction and Lenses

OPTICAL SYSTEMS OBJECTIVES


Lens Design I. Lecture 10: Optimization II Herbert Gross. Summer term

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing.

Assignment X Light. Reflection and refraction of light. (a) Angle of incidence (b) Angle of reflection (c) principle axis

REFLECTION THROUGH LENS

Mirrors, Lenses &Imaging Systems

LENSES. a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses.

Thin Lenses * OpenStax

Optics: Lenses & Mirrors

Downloaded from

Lenses. A transparent object used to change the path of light Examples: Human eye Eye glasses Camera Microscope Telescope

All-spherical catadioptric telescope design for wide-field imaging

Optical Design with Zemax for PhD

Performance Factors. Technical Assistance. Fundamental Optics

Chapter 23. Mirrors and Lenses

Converging and Diverging Surfaces. Lenses. Converging Surface

LIGHT-REFLECTION AND REFRACTION

Algebra Based Physics. Reflection. Slide 1 / 66 Slide 2 / 66. Slide 3 / 66. Slide 4 / 66. Slide 5 / 66. Slide 6 / 66.

Laboratory experiment aberrations

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

30 Lenses. Lenses change the paths of light.

Lens Design I Seminar 1

LIGHT REFLECTION AND REFRACTION

PHYSICS OPTICS. Mr Rishi Gopie

don, G.B. U.S. P. DOCUMENTS spaced by an air gap from the collecting lens. The widths of

A. Focal Length. 3. Lens Maker Equation. 2. Diverging Systems. f = 2 R. A. Focal Length B. Lens Law, object & image C. Optical Instruments

BHARATIYA VIDYA BHAVAN S V M PUBLIC SCHOOL, VADODARA QUESTION BANK

Introductions to aberrations OPTI 517

Chapter 36. Image Formation

Geometric Optics. Ray Model. assume light travels in straight line uses rays to understand and predict reflection & refraction

Dr. Todd Satogata (ODU/Jefferson Lab) Monday, April

Physics 142 Lenses and Mirrors Page 1. Lenses and Mirrors. Now for the sequence of events, in no particular order. Dan Rather

Physics 222, October 25

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Big League Cryogenics and Vacuum The LHC at CERN

PHYSICS FOR THE IB DIPLOMA CAMBRIDGE UNIVERSITY PRESS

Lenses Design Basics. Introduction. RONAR-SMITH Laser Optics. Optics for Medical. System. Laser. Semiconductor Spectroscopy.

Double-curvature surfaces in mirror system design

There is a range of distances over which objects will be in focus; this is called the depth of field of the lens. Objects closer or farther are

CHAPTER 33 ABERRATION CURVES IN LENS DESIGN

Transcription:

2013 THOSS Media & DOI 10.1515/aot-2012-0078 Adv. Opt. Techn. 2013; 2(1): 111 116 Research Article Andrew Rakich* and Norman J. Rumsey A new prime-focus corrector for paraboloid mirrors Abstract: A new form of field corrector for astronomical telescopes with paraboloid primary mirrors is described. Like an earlier design by Wynne, it consists of four spaced lens elements with spherical surfaces only. In commonly occurring circumstances, the new design gives better image sharpness than does Wynne s. The new system outperforms Wynne s system for any probable wavelength range, when the field of view exceeds ~50 arc-minutes. Wynne s original system tends to work better for narrower fields of view with a larger wavelength range. Also, the new system is closer to being telecentric than Wynne s, which is of interest to the developers of multifiber-fed systems. Further, the geometry of the new system should yield a modestly reduced manufacturing cost. The problem can be overcome if one is willing to insert some relatively small optical elements (lenses, mirrors, or both) into the optical path before the light reaches prime focus. It is generally considered that a correcting system using only lenses, usually all made from the same type of glass, is the most convenient and practical, though it introduces small amounts of spherochromatic aberration, chromatic variation of coma, and other chromatic effects that would be absent in a system using only mirrors. In this paper, we describe a recently discovered arrangement of four lens elements that performs well as a prime-focus field corrector for a paraboloid mirror and compare its performance with that of an alternative arrangement of four lens elements that has been known for a long time. Keyword: astronomical optics ; optical design ; prime focus corrector ; telescopes. OCIS codes: 350.1260; 220.0220. Deceased. *Corresponding author: Andrew Rakich, European Southern Observatory, Tech Division, Karl Schwarzschild Strss. 2 Munich Bavaria 85748, Germany, e-mail: arakich@eso.org Norman J. Rumsey: 21 Malone Rd, Lower Hutt, New Zealand 1 Introduction Many reflecting telescopes have a paraboloid primary mirror. This is free from spherical aberration; so in the middle of the field at prime focus, the definition of the image is as near perfection as the manufacturing defects, misalignment, and the atmosphere allows. However, field curvature, coma, and astigmatism are not corrected. This means that the definition becomes increasingly poor as the image point gets further from the centre of the field (and very rapidly so) if the mirror has a fast relative aperture. Thus, the field of acceptably sharp definition delivered by a paraboloid mirror alone is often very much smaller than is desirable. www.degruyter.com/aot 2 The old (Wynne) system Some time ago, Wynne [ 1 ] published a design for a primefocus corrector for a paraboloid mirror that had smaller residual aberrations than those of earlier designs. It consisted of four lens elements spaced apart with spherical surfaces only. The signs of the optical powers of each element were in the order + - - +, counting the first element as that closest to the primary mirror. This facilitated simultaneous correction of the longitudinal and transverse (lateral) chromatic aberrations. The first three lens elements were menisci with the convex surfaces facing the mirror. The last lens element had a convex first surface facing the mirror. Its second surface had a long radius of curvature. It could be convex, plane, or concave depending on the relative aperture and field of view of the system (see Figure 1 ). Wynne s paper included a detailed explanation of the considerations that led to this design and a commentary on the design process. It also included the specification and a cross-section drawing for such a lens system designed for use on the Palomar Observatory 5.08-m (200-inch) telescope. One feature of this system for Palomar deserves comment. In his paper, Wynne stated The thickness of the individual lenses were constrained to be as small as was compatible with manufacture, so as to minimize the

112 A. Rakich and N.J. Rumsey: Prime-focus corrector for paraboloid mirrors 2013 THOSS Media & Figure 1 Wynne-type prime-focus corrector with detail of the corrector lens (inset). absorption at short wavelengths. A comment made subsequently by Wynne to one of the authors of this paper (N.J.R.) suggests that he was not at all happy with the very small thickness that astronomers were demanding. The thin meniscus lens elements flex perceptibly under a much smaller applied force than most people would expect. This causes them to be very difficult to manufacture with the desired precision. The readers of Wynne s paper should not assume that the thickness used for the first three lens elements of the corrector described there would be acceptable to a manufacturer of such systems. Wynne subsequently published another paper [ 2 ] giving the specifications for three more four-lens-element Wynnetype correctors for various relative apertures and fields of view with more nearly reasonable lens thicknesses. There is a peculiarity shared by almost all the designs for the prime-focus field correctors (including the popular three-lens types, which are not discussed here). The principal rays of oblique pencils, after reflection from the mirror, are in general diverging at small angles from the axis seldom exceeding 1. However, after passing through the field corrector, these same rays emerge into the image space converging toward the axis at angles that are considerably larger than those at which they were diverging after the reflection from the mirror. This angular magnification averaged to ~5.5 for a number of Wynne-type field correctors designed to work with an f/2.5 paraboloid mirror, where the correctors investigated worked over different fields (ranging from 40 to 60 arc-minutes) and wavelength ranges. Before fiber-fed multi-object spectroscopy was developed, this peculiarity was of little concern to anyone. However, optical fibers have a limiting numerical aperture. While all rays for the axial pencil may fall within this limit for a given system, as the obliquity of the principal ray increases, the maximum angle of a marginal ray entering the fiber increases correspondingly. Therefore, a non-telecentric system will have a reduced maximum-permissible image-space numerical aperture when compared to that of a telecentric system. Also, if the light emerging from an optical fiber is to have the minimum possible f-number, it is necessary that the cone of light converging onto the input end of the fiber has an axis that coincides with that of the fiber in the direction as well as in the lateral position. This can be achieved most easily if the optical system is telecentric in the image space; that is, the principal rays of the oblique pencils are parallel to the axis where they meet the image plane. In general, a prime focus corrector can be forced to be telecentric, but if this is done without introducing new degrees of freedom, the result will, in general, be a loss of image sharpness, and any loss of image sharpness is intolerable. Thus, we should like to find a design for a field corrector that has uncompromised image sharpness (at least as good as the Wynne system) and, at the same time, is naturally closer to being telecentric in the image space, than the Wynne-type system. 3 The new system In November 2002, an author of this paper (A.R.) had been designing a Wynne-type corrector when he thought of trying the effect of reversing the third lens element, as part of a more general effort to improve the performance of the Wynne design. This was a meniscus negative lens element, which, after reversal, had its concave surface facing the mirror. During reoptimization, it moved close to the positive fourth (last) lens element (see Figure 2 ). There, it could be decidedly smaller in diameter than in its original position. This is the first advantage of the new system. Next, the image sharpness was somewhat better than that of the Wynne-type designed for the same relative aperture, wavelength range, and field of view. Both authors have consistently found this to be the case for the systems of interest to them. However, we have recently discovered that there are circumstances in which this is not the case. This is discussed below.

2013 THOSS Media & A. Rakich and N.J. Rumsey: Prime-focus corrector for paraboloid mirrors 113 Figure 2 Modified Wynne prime-focus corrector with detail of the corrector lens (inset). Last, the new system is somewhat closer to being tele centric in the image space than is the Wynne type. The average angular magnification of the principal rays for an array of modified Wynne-type systems matching the array of Wynne-type systems described above is ~3.73 times. This is about 68% of the corresponding figure for the Wynne-type systems. This is a substantial step toward the ideal system, but still falls well short of it. The figure we would like to see is zero. An example of a modified Wynne-type corrector was constructed for a 1.8-m diameter paraboloid mirror and is discussed by Hearnshaw et al. [ 3 ]. 4 Effects of wavelength and field of view The range of wavelengths and the field of view over which the field corrector is required to maintain good image sharpness can vary considerably. We are inclined to think of a range of wavelengths from 0.365 to 0.852 μ m and a total field of view of 1 as normal. In these circumstances, with a paraboloid mirror of relative aperture f/2.5, and with the first lens surface at 10% of the focal length of the mirror ahead of the prime focus, the modified Wynne type gives somewhat better image sharpness than the Wynne type does. On the other hand, for the 4.2-m William Herschel telescope [ 4 ], the choices were for a wider range of wavelengths: 0.33 to 1.00 μ m and a smaller field of view: 40 arc-minutes. In this case, it turns out that the Wynne-type system gives better image sharpness than the modified Wynne type. We had not expected this, but a careful examination of the residual aberrations of the two systems explains it. The Wynne-type system has less spherochromatic aberration than the modified Wynne type, which gives the Wynne type an advantage when the range of wavelengths is large, but the Wynne type has more coma varying zonally with field and more chromatic variation of coma than the modified Wynne type, which gives the modified Table 1 Constructional parameters for the Wynne system from section 5. System/prescription data Surface data summary Surf Type Radius Thickness Glass Diameter Conic OBJ Standard Infinity Infinity 0 0 STO Standard Infinity -25 1000 0 2 Standard 5000 2250 Mirror 1000-1 3 Standard 117.984 10 N-BK7 133.3363 0 4 Standard 142.208 43.17684 129.9094 0 5 Standard 193.74 8 N-BK7 110.7898 0 6 Standard 129.223 62.69359 104.6961 0 7 Standard 131.084 7 N-BK7 81.3703 0 8 Standard 70.2407 80.89863 75.77558 0 9 Standard 115.2B 10 N-BK7 67.54992 0 10 Standard -1822.B 39.91074 66.25796 0 IMA Standard Infinity 47.93528 0 Table 2 Constructional parameters for the modified Wynne system from section 5. System/prescription data Surface data summary Surf Type Radius Thickness Glass Diameter Conic OBJ Standard Infinity Infinity 0 0 STO Standard Infinity -25 1000 0 2 Standard 5000 2250 Mirror 1000-1 3 Standard 96.89674 10 N-BK7 131.4426 0 4 Standard 108.946 60.9832 127.4426 0 5 Standard 295.4358 8 N-BK7 103.1096 0 6 Standard 119.9538 130.5481 96.60712 0 7 Standard -76.58673 7 N-BK7 64.57311 0 8 Standard -113.9346 1.02 65.94145 0 9 Standard 125.2086 10 N-BK7 64.97223 0 10 Standard -637.617 35.31912 63.75507 0 IMA Standard Infinity 47.76872 0

114 A. Rakich and N.J. Rumsey: Prime-focus corrector for paraboloid mirrors 2013 THOSS Media & Figure 3 Comparison of spot diagrams for the original Wynne system (upper) and the modified Wynne system (lower) from the systems defined in Tables 1 and 2. Wynne type an advantage when the field of view is large. Thus, we can say: If the range of wavelengths is large and the field of view is small, the Wynne type gives the better image sharpness. If the range of wavelengths is small and the field of view is large, the modified Wynne type gives the better image sharpness. This does not tell the reader where the boundary lies between the two regions of interest, so we have carried

2013 THOSS Media & A. Rakich and N.J. Rumsey: Prime-focus corrector for paraboloid mirrors 115 out lengthy calculations, which provide the following information: If the wavelength range is 0.33 1.00 μ m, then, the boundary is at a total field of 58 arc-minutes. If the wavelength range is 0.365 0.852 μ m, then, the boundary is at 53 arc-minutes. If the wavelength range is 0.405 0.656 μ m, then, the boundary is at 50 arc-minutes. 5 Example To illustrate the differences between the two systems, details are given here for each of the Wynne type and modified Wynne-type correctors, as illustrated in Figures 1 and 2. Both of these systems use a 1-m diameter primary mirror of f/2.5, a wavelength range of 0.365 to 0.852 μ m, and both work over a field of view of 1 diameter with a final working f-number of 2.70. Table 1 details the constructional parameters of the Wynne system, Table 2 for the modified Wynne-type system. Figure 3 shows comparative spot diagrams. The Wynne system given here produces RMS spot sizes for off-axis field points, on average 20%, larger than the modified Wynne-type system. The Wynne system given here has a 23% greater departure from telecentricity than the modified Wynne-type system. 6 Comments The reader should not take the boundary values given above to be highly precise. A differently structured defect function, a relative aperture of the mirror other than f/2.5, and a position of the first lens surface other than 10% of the focal length of the mirror ahead of the prime focus may all contribute to somewhat different results. To investigate these matters in a thorough manner would require more computing time than we are willing to spare at present. If the field corrector is feeding light to an array of optical fibers, it may well be considered that the somewhat closer approach of the modified Wynne type to the ideal telecentric system should give it precedence over the Wynne type, even in cases where image sharpness alone favors the latter. 7 Conclusions There are combinations of wavelength range and field for which the new modified Wynne-type field corrector gives better image sharpness than the old Wynne type. If the total field is 1 or larger, the modified Wynne type is better for almost any likely range of wavelengths. If the total field is < 50 arc-minutes, the Wynne type is better for almost any likely range of wavelengths. For an intermediate field, some guidance is given in the discussion of the effects of wavelength range and field above. Note that these figures were derived for systems with just one relative aperture for the mirror and just one position for the first lens surface. Both systems suffer from the convergence of principal rays toward the axis in the image space. For feeding light into an extended array of optical fibers, we should prefer a telecentric system, that is, the principal rays of the oblique pencils are parallel to the axis in image space. For the modified Wynne-type system, the departure from the ideal is about 68% that for the Wynne-type system. This makes the modified Wynne-type system decidedly the preferred type in this respect. The reduced diameter of the third lens element and its closeness to the fourth (final) lens element give the modified Wynne-type system a manufacturing advantage. Author contributions: Andrew Rakich did the original optical design, wrote the paper, and produced ~ ½ the analysis. Norman Rumsey provided the rest of the analysis. Acknowledgment: Andrew Rakich would like to acknowledge Sue Worswick for her helpful suggestions and comments. Received November 29, 2012; accepted January 8, 2013 References [1] C. G. Wynne, Appl. Opt. 6, 1227 (1967). [2] C. G. Wynne, M.N.R.A.S. 165, 1P (1973). [3] J. B. Hearnshaw, et al., in Proceedings of the 9th Asia-Pacific Regional IAU Meeting, Ed. by W. Sutantyo et al., (Bali, 2005) pp. 272 273. [4] R. N. Wilson, Reflecting Telescope Optics I, Revised 2nd Edition (Springer, 2007), pp. 348 372.

116 A. Rakich and N.J. Rumsey: Prime-focus corrector for paraboloid mirrors 2013 THOSS Media & Andrew Rakich is an optical designer, currently employed by the European Southern Observatory. Andrew s particular professional interests are the analytical approaches to optical design, geometrical optical aberration theory, and the history of geometrical optical aberration theory. Norman Rumsey was an optical designer employed by the D.S.I.R., New Zealand, from 1946 until his retirement in 1987. Norman died in 2007.