BAT-Series Grid Inverter. Battery Charger.

Similar documents
/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1)

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface

PV Grid-connected Inverter

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

FRONIUS IG PLUS TRANSFORMER INVERTER

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS ULTRA CORE PLUS

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS CENTRALIZED MODELS PLUS

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

TECHNICAL DATA SHEET B9600FXS kva

Technical Data Sheets

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

Orbital GFI Inverter Series

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

GE+ Grid Emulator Plus

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

The future-proof inverter for small self-consumption systems

DCPS Programmable DC Power Supply

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

Gutor PxW AC UPS Designed for North American Market

GE+ Grid Emulator. Key features. Highlights. High-Resolution and Dynamics. Efficiency and Flexibility. Smooth Integration. Harmonics Generation

Growatt 4000 UE / 5000 UE / 6000 UE

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

PV Grid-connected Inverter

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

200W DIN Rail Programmable Output Voltage Power Supply

Installation requirements

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

EL-AC Electronic Load

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

UMG 96RM Basic Device

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets

StatiVolt. Inverter UPS Systems. Features. Contents

This Chapter contains:

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

English 8 P EN.01/01.


3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Technical Information Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

ahead of time Static Digital Voltage Stabilisers

Power Quality and Energy Measurement PEM533

MAJORSINE Power Inverter

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

StacoDVR-4 Digital Voltage Regulator Electromechanical three-phase kVA

FRONIUS ESPAÑA, S.L.U. Parque Industrial La Laguna. Calle Arroyo del Soto, Leganés. Madrid. SPAIN. PV inverters PRIMO-1

GE-AC&DC AC&DC Voltage Source

Inverter MICROMASTER 410

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Automatic capacitor banks with detuned filters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Power Quality and Energy Measurement PEM575

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

SX (400 V) System configuration

SX (690 V) System configuration

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Technical Information Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL

SM2000 TECHNICAL DESCRIPTION

Automatic capacitor banks with detuned filters

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

PowerFlex 400 Submittal

The new Yaskawa Varispeed G7 Inverter

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Phoenix DX Clean Power (18 Pulse) AC Drive

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

SUPPLY NETWORK ANALYZER CVM-96 SERIES

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

Fluke 3540 FC Three-Phase Power Monitor

Power IT LV Active Filters PQFA - PQFL - PQFT

R&D TECHNICAL SPECIFI

PEM353. Universal measuring device

Transcription:

BAT-Series Grid Inverter. Battery Charger. With the BAT-series, WSTECH offers a wide range of power converters for small to large energy storage applications. The BAT-series inverters offer a power range from 20 kva up to 1800 kva with the following options and features: Modbus TCP interface that operates all control values, monitoring of all status values and overall configuration of the device. Modbus TCP is a wide-spread Ethernet-based fieldbus. EtherCAT interface (Ethernet-based real time field bus) prepared for active exchange of selected control and status values (configurable) in very fast control applications (millisecond-range). Touch Display for monitoring of selected status and configuration data, error messages review and on/off machine operation for maintenance work. Internal Data Logger capable of recording all status and control values with a sample time of 10 s for up to 1 year on the integrated USBmemory. Grid stabilization in compliance with local grid code. Supply of reactive power for different applications. Outdoor models available for demanding weather conditions. 1/20

30 280 kva (I) TECHNICAL DATA BATI 20 BAT 50 BAT 100 BAT 280 COMMENTS GRID SIDE Maximum AC-power (S max ) 30 kva (for 10 s) 55 kva 120 kva (2 h) 280 kva At rated grid voltage Rated AC-power (P N (AC) ) 20 kw 50 kw 100 kw 280 kw At ( cos ϕ ) = 1.0 Rated grid voltage (U N (AC) ) 1 x (400 V, 3~ + neutral, TN) Other values on request Rated grid frequency (f) 50 Hz Other values on request Maximum AC-current (I max (AC) ) 30 A 79 A 173 A 404 A Short circuit level (I SC (AC) ) 6 ka 36 ka Power factor (cos ϕ) > 0.98 At > 20 % of rated power AC-current distortion (THD) < 3 % BATTERY SIDE Nominal voltage (U N (DC) ) - 750 V DC Voltage range (U range (DC) ) 120 375 V DC 530 890 V DC 450 890 V DC Currents (I range (DC) ) + / - 130 A + / - 110 A + / - 250 A + / - 630 A Maximum short circuit current (I SC (DC) ) 200 ka 40 ka Current THD < 3 % Number of DC inputs 1 GENERAL Control strategy Efficiency in % - CC-CV, power controlled, island mode ( 94.0 96.5 96.5 96.0 95.2 ) % ( 93.9 96.9 97.1 97.0 96.7 ) % ( 92.2 97.1 97.2 96.8 96.4 ) % At ( 10 30 50 75 100 ) % power Standby losses at night < 6 W < 30 W Maximum auxiliary power < 120 W < 250 W < 600 W Plus heating power MEASURING ACCURACY Grid Frequency +/- 20 mhz +/- 40 mhz Average value of 8 grid periods 2/20

600 1200 kva (II) TECHNICAL DATA BATI 600 BATI 720 BATI 900 BATI 1200 COMMENTS GRID SIDE Maximum AC-power (S max ) 600 kva 720 kva 900 kva 2 x (600 kva) At rated grid voltage Rated AC-power (P N (AC) ) 500 kw 615 kw 770 kw 2 x (500 kw) At ( cos ϕ ) = 1.0 Other values on request Recommendation of vector group: Rated grid voltage (U N (AC) ) 1 x (270 V, 3~, IT) 1 x (300 V, 3~, IT) 1 x (380 V, 3~, IT) 2 x (270 V, 3~, IT) -Medium-voltage connection: Dd -Low-voltage connection: YNd or Yd -d: delta connection of inverter Rated grid frequency (f) 50 Hz Other values on request Maximum AC-current (I max (AC) ) 1283 A 1385 A 1367 A 2 x (1283 A) Short circuit level (I SC (AC) ) 50 ka Power factor (cos ϕ) > 0.98 At > 20 % of rated power AC-current distortion (THD) < 3 % BATTERY SIDE> Nominal voltage (U N (DC) ) 750 V DC Voltage range (U range (DC) ) 450 890 V DC 500 890 V DC 630 890 V DC 2 x (450 890 V DC ) Currents (I range (DC) ) + / - 1136 A + / - 1360 A + / - 1400 A 2 x (+/- 1136 A) Maximum short circuit current (I SC (DC) ) 6,4 ka Current THD < 3 % Number of DC inputs 1 2 3/20

600 1200 kva (III) TECHNICAL DATA GENERAL Control strategy Efficiency in % BATI 600 BATI 720 BATI 900 BATI 1200 COMMENTS ( 97.1 97.5 97.5 97.3 97.1 ) % CC-CV, power controlled, island mode ( 97.4 97.9 97.9 97.7 97.5 ) % ( 97.6 98.0 98.0 97.8 97.6 ) % ( 97.1 97.5 97.5 97.3 97.1 ) % At ( 10 30 50 75 100 ) % power Standby losses at night < 30 W < 60 W Maximum auxiliary power < 1000 W < 2000 W Plus heating power MEASURING ACCURACY Grid Frequency +/- 40 mhz Average value of 8 grid periods 4/20

1440 1800 kva (IV) TECHNICAL DATA BATI 1440 BATI 1800 COMMENTS GRID SIDE Maximum AC-power (S max ) 2 x (720 kva) 2 x (900 kva) At rated grid voltage Rated AC-power (P N (AC) ) 2 x (615 KW) 2 x (770 kw) At ( cos ϕ ) = 1.0 Other values on request Recommendation of vector group: Rated grid voltage (U N (AC) ) 2 x (300 V, 3~, IT) 2x (380 V, 3~, IT) -Medium-voltage connection: Dd -Low-voltage connection: YNd or Yd -d: delta connection of inverter Rated grid frequency (f) 50 Hz Other values on request Maximum AC-current (I max (AC) ) 2 x (1385 A) 2 x (1367 A) Short circuit level (I SC (AC) ) 50 ka Power factor (cos ϕ) > 0.98 At > 20 % of rated power AC-current distortion (THD) < 3 % BATTERY SIDE Nominal voltage (U N (DC) ) 750 V DC Voltage range (U range (DC) ) 2 x (500 890 V DC ) 2 x (630 890 V DC ) Currents (I range (DC) ) 2 x (+/- 1360 A) 2 x (+/- 1400 A) Maximum short circuit current (I SC (DC) ) 6,4 ka Current THD < 3 % Number of DC inputs 2 5/20

1440 1800 kva (V) TECHNICAL DATA BATI 1440 BATI 1800 COMMENTS GENERAL Control strategy CC-CV, power controlled, island mode Efficiency in % ( 97.4 97.9 97.9 97.7 97.5 ) % ( 97.6 98.0 98.0 97.8 97.6 ) % At ( 10 30 50 75 100 ) % power Standby losses at night < 60 W Maximum auxiliary power < 2000 W Plus heating power MEASURING ACCURACY Grid Frequency +/- 40 mhz Average value of 8 grid periods 6/20

BAT-Series Outdoor 120 280 kva (I) TECHNICAL DATA BAT 100-400 BAT 100-480 BAT 280-400 BAT 280-480 COMMENTS GRID SIDE Maximum AC-power (S max ) 120 kva (2 h) 280 kva At rated grid voltage Rated AC-power (P N (AC) ) 100 kw 280 kw At ( cos ϕ ) = 1.0 Rated grid voltage (U N (AC) ) 1 x (400 V, 3~ + neutral, TN) 1x (480Y / 277 V, solidly grounded wye, 3 phase, 4 wire) 1 x (400 V, 3~ + neutral, TN) 1x (480Y / 277 V, solidly grounded wye, 3 phase, 4 wire) Other values on request Rated grid frequency (f) 50 Hz 60 Hz 50 Hz 60 Hz Maximum AC-current (I max (AC) ) 173 A 144 A 404 A 337 A Short circuit level (I SC (AC) ) 36 ka 35 ka 36 ka 35 ka Power factor (cos ϕ) > 0.98 At > 20 % of rated power AC-current distortion (THD) < 3 % BATTERY SIDE Nominal voltage (U N (DC) ) 750 V DC Voltage range (U range (DC) ) 450 890 V DC Currents (I range (DC) ) + / - 250 A + / - 266 A + / - 630 A + / - 600 A Maximum short circuit current (I SC (DC) ) 40 ka 5 ka 40 ka 10 ka Current THD < 3 % Number of DC inputs 1 GENERAL Control strategy Efficiency in % ( 93.9 96.9 97.1 97.0 96.7 ) % CC-CV, power controlled, island mode ( 93.9 96.9 97.1 97.0 96.7 ) % ( 92.2 97.1 97.2 96.8 96.4 ) % ( 92.2 97.1 97.2 96.8 96.4 ) % At ( 10 30 50 75 100 ) % power Standby losses at night < 30 W Maximum auxiliary power < 250 W < 600 W Plus heating power 7/20

BAT-Series Outdoor 120 280 kva (II) TECHNICAL DATA MEASURING ACCURACY DC-voltage - BAT 100-400 BAT 100-480 BAT 280-400 BAT 280-480 COMMENTS 1% of maximum DC-voltage - 1% of maximum DC-voltage AC-voltage - 1% of rated voltage - 1% of rated voltage DC-current - 1% of maximum DC-current - 1% of maximum DC-current AC-current - 1% of rated current - 1% of rated current Active Power (AC) - Apparent Power (AC) - Reactive Power (AC) - Active Power (DC) - 2% of maximum AC-power 2% of maximum AC-power 2% of maximum AC-power 2% of maximum DC-power - - - - 2% of maximum AC-power 2% of maximum AC-power 2% of maximum AC-power 2% of maximum DC-power Grid Frequency +/- 40 mhz Average value of 8 grid periods 8/20

30 280 kva (I) GENERAL DATA BATI 20 BAT 50 BAT 100 BAT 280 COMMENTS GENERAL Ambient temperature 0 C 40 C 0 C... 50 C Other values on request Maximum humidity < 95 % Not condensing Ambient storage temperature - -25 C... 60 C Storage relative humidity - < 90 % Not condensing Maximum operating altitude 1500 m above sea level Without power derating Cooling type Forced air Air cooling volume 360 m 3 /h 800 m 3 /h 1500 m 3 /h 3000 m 3 /h Class 3S2 (EN60721-3-3) Protection class IP20 Dimensions (Length x Width x Height) 19 inch rack, 7 RU 611 x 647 x 1902 1009 x 862 x 1903 1409 x 846 x 1906 In mm Weight < 60 kg < 800 kg < 1050 kg < 1600 kg Color Aluminum RAL7035 Others on request Noise Level < 70 dba < 80 dba EMI EN61000-6-2, EN61000-6-4 Medium voltage directive - BDEW Others on request Low voltage directive VDE-AR-N 4105 CE-conformity Comply 9/20

600 1200 kva (II) GENERAL DATA BATI 600 BATI 720 BATI 900 BATI 1200 COMMENTS GENERAL Ambient temperature 0 C... 50 C Other values on request Maximum humidity < 95 % Not condensing Ambient storage temperature -25 C... 60 C Storage relative humidity < 90 % Not condensing Maximum operating altitude 1500 m above sea level Without power derating Cooling type Forced air Air cooling volume 3600 m 3 /h 2 x (3600 m 3 /h) Class 3S2 (EN60721-3-3) Protection class IP20 Dimensions (Length x Width x Height) 1813 x 867 x 2172 3260 x 867 x 2172 In mm Weight < 1600 kg < 2950 kg Color RAL7035 Others on request Noise Level < 80 dba EMI EN61000-6-2, EN61000-6-4 Medium voltage directive BDEW Others on request Low voltage directive - CE-conformity Comply 10/20

1440 1800 kva (III) GENERAL DATA BATI 1440 BATI 1800 COMMENTS GENERAL Ambient temperature 0 C... 50 C Other values on request Maximum humidity < 95 % Not condensing Ambient storage temperature -25 C... 60 C Storage relative humidity < 90 % Not condensing Maximum operating altitude 1500 m above sea level Without power derating Cooling type Forced air Air cooling volume 2 x (3600 m 3 /h) Class 3S2 (EN60721-3-3) Protection class IP20 Dimensions (Length x Width x Height) 3260 x 867 x 2172 In mm Weight < 2950 kg Color RAL7035 Others on request Noise Level < 80 dba EMI EN61000-6-2, EN61000-6-4 Medium voltage directive BDEW Others on request Low voltage directive - CE-conformity Comply 11/20

BAT-Series Outdoor 120 280 kva GENERAL DATA GENERAL Ambient temperature -20 C... 50 C BAT 100-400 BAT 100-480 BAT 280-400 BAT 280-480 COMMENTS -10 C... 50 C (14 F... 122 F) -20 C... 50 C -10 C... 50 C (14 F... 122 F) Other values on request Maximum humidity 100 % Not condensing Ambient storage temperature -25 C... 60 C Storage relative humidity < 90 % Not condensing Maximum operating altitude 1500 m above sea level Without power derating Cooling type Forced air Air cooling volume 1500 m 3 /h 3000 m 3 /h Class 3S2 (EN60721-3-3) Protection class IP44 NEMA 3R IP44 NEMA 3R Dimensions (Length x Width x Height) 1152 x 1250 x 2249 1597 x 1353 x 2249 In mm Weight < 950 kg < 2000 kg Color RAL7035 Others on request Noise Level < 80 dba EMI EN61000-6-2, EN61000-6-4 - EN61000-6-2, EN61000-6-4 Medium voltage directive BDEW - BDEW - Others on request Low voltage directive VDE-AR-N 4105 - VDE-AR-N 4105 - CE-conformity Comply - Comply - UL 1741:2010 + SA:2016 - Comply - Comply CSA Standard, C22.2 No. 107.1-01: 2011 - Comply - Comply CEC Guideline - Comply - Comply - 12/20

30 600 kva (I) FEATURES AND OPTIONS BATI 20 BAT 50 BAT 100 BAT 280 BATI 600 FEATURES Overvoltage protection - X X X X Earth leakage monitor with adjustable limit - X X X X Enable switch - X X X X DC-disconnector X - - - X DC-circuit breaker - X X X - DC-contactor with fuses X - - - - AC-circuit breaker - X X X X Modbus TCP interface - X X X X CAN interface X - - - - Internal data logger - X X X X OPTIONS Island grid function O O O O O Interface for SBB16-10 - O O O - Cabinet heating - O O O O EtherCAT interface - O O O O Graphical display (HMI) - O O O - X = included - = not included / not available O = optional 13/20

720 1800 kva (II) FEATURES AND OPTIONS BATI 720 BATI 900 BATI 1200 BATI 1440 BATI 1800 FEATURES Overvoltage protection X X X X X Earth leakage monitor with adjustable limit X X X X X Enable switch X X X X X DC-disconnector X X X X X DC-circuit breaker - - - - - DC-contactor with fuses - - - - - AC-circuit breaker X X X X X Modbus TCP interface X X X X X CAN interface - - - - - Internal data logger X X X X X OPTIONS Island grid function O O O O O Interface for SBB16-10 - - - - - Cabinet heating O O O O O EtherCAT interface O O O O O Graphical display (HMI) - - - - - X = included - = not included / not available O = optional 14/20

BAT-Series Outdoor 120 280 kva FEATURES AND OPTIONS BAT 100-400 BAT 100-480 BAT 280-400 BAT 280-480 FEATURES Overvoltage protection X X X X Earth leakage monitor with adjustable limit X X X X Enable switch X X X X DC-disconnector - - - - DC-circuit breaker X X X X DC-contactor with fuses - - - - AC-circuit breaker X X X X Modbus TCP interface X X X X CAN interface - - - - Internal data logger X X X X Cabinet heating X X X X OPTIONS Island grid function O O O O Interface for SBB16-10 - - - - EtherCAT interface O O O O Graphical display (HMI) - - - - X = included - = not included / not available O = optional 15/20

30 120 kva (I) MECHANICAL DRAWINGS BATI 20 BAT 50 BAT 100 16/20

280 900 kva (II) MECHANICAL DRAWINGS BAT 280 BATI 600 / BATI 720 / BATI 900 17/20

1200 1800 kva (III) MECHANICAL DRAWINGS BATI 1200 / BATI 1400 / BATI 1800 18/20

BAT-Series Outdoor 120 280 kva MECHANICAL DRAWINGS BAT 100-400 / BAT 100-480 BAT 280-400 / BAT 280-480 19/20

CONTACT SALES DEPARTMENT GERMANY WSTECH GmbH Eckernfoerder Landstrasse, 78 D-24941 Flensburg Germany Phone +49 (0) 461 430 1220 E-Mail info@wstech.com SALES DEPARTMENT WORLDWIDE WSTECH (Spanish office) Carrer de l'enginy, Nave 7 E-08840 Viladecans (Barcelona) Spain Phone +34 936 334 416 E-Mail info@wstech.com Datasheet version Datasheet_BAT-Series_V24_eng. Copyright 2018. All rights reserved. Specifications subject to change without notice. WSTECH assumes no liability for typographical or other errors. 20/20