PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Accutech GP10. Wireless gauge pressure field unit

Accutech AP10. Wireless absolute pressure field unit

Accutech TC10. Wireless thermocouple temperature field unit

Accutech DP20. Wireless differential pressure field unit

Accutech RT10. Wireless RTD temperature field unit

Accutech FL10. Wireless float level field unit

Accutech AM20. Wireless acoustic monitor field unit

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

XYR 5000 Wireless Differential Pressure Transmitter

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications

Accutech AI10 & AV10. Wireless multi-input field unit

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

0 2 1 â Ó. itemp HART TMT182. Technical Information

Two-Wire Programmable Transmitter for:

Fisher 646 Electro Pneumatic Transducer

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

XYR 5000 Wireless Transmitters SIMPLE. SAFE. SECURE. Honeywell Solutions for Wireless Data Acquisiton and Monitoring

Fisher 646 Electro-Pneumatic Transducers

The Rosemount 848T Wireless Temperature Transmitter

0 2 1 â Ó. itemp HART TMT182. Technical Information

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

Temperature transmitter itemp PCP DIN rail TMT 121

itemp HART DIN rail TMT112

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Accutech AI10 & AV10. Wireless multi-input field unit

Temperature transmitter itemp RTD DIN rail TMT 127

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Fisher 4200 Series Electronic Position Transmitters

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

Temperature Measurement Transmitters for mounting in sensor head

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

Temperature Measurement

itemp PA TMT184 Technical information

Rosemount 702 Discrete Input Transmitter

Rosemount 248 Wireless Temperature Transmitter

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Temperature Input Module for Zone 1 Series 9482/32

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp TC TMT 188

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Measurement Transmitters for mounting in sensor head

Head mounted Temperature Transmitter TF02/TF02-Ex

Rosemount 148 Temperature Transmitter

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Process display RIA 261

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Rosemount 648 Wireless Temperature Transmitter

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Single-Channel Safety Barriers Series 9001

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Technical Specification Datasheet

Accutech BR10. Wireless base radio

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

STT 3000 Smart Temperature Transmitter

SITRANS T measuring instruments for temperature

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Temperature transmitter with local display RIT 261

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Temperature Measurement

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

SmartPower Solutions. Product Data Sheet February , Rev AD

Resistance thermometer Model TR30, compact design

ER WIRELESS TRANSMITTER

Rosemount 148 Temperature Transmitter

Alphaline Temperature Transmitters

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Field IT 2600T Series Pressure Transmitters

Wireless Transmitter Series XYR 6000 Series 100 Gauge Pressure Models Specifications

Smart Pressure Transmitter

Analog Universal Module HART for Zone 2 Series 9468/33

IP26 Series Current to Pneumatic Converter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Coriolis Massflowmeter

Model 264IB. ABB 2600T Series Engineered solutions for all applications

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

General Specifications

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Temperature head transmitter itemp PCP TMT 181

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Rosemount 148 Temperature Transmitter

Transcription:

XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless products. These transmitters are wireless temperature transmitters that can be used to monitor a variety of processes in hazardous and remote areas. Since there are no wires to run, the transmitter can be installed and operational in minutes, quickly providing information about the variable being monitored. The Smart Response Manager allows the transmitter to adapt to changing process conditions, allowing greater visibility to process variation. Smart Response Manager allows the user to set thresholds which, when exceeded, cause the transmitter to increase sampling and data transmission rates. Optional discrete inputs are available for Monitoring process variables Discrete monitoring at the base radio. The transmitter combines an integrated temperature sensor, with a Radio Frequency (RF) transceiver t operating in the 900MHz ISM license-free band. Communication is a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Power is supplied by a C size 3.6 V lithium battery, with an expected lifetime of up to five years. Enjoy the benefits of wireless technology today: Improve Product Quality Ensure High Uptime Reduce Maintenance and Operational Costs Meet Regulatory Requirements Enhance Flexibility Wireless Transmitters Base Radio

PROBE OPTIONS Probe Type RANGE RANGE DEG. F DEG. C Pt100 RTD (DIN.00385) -328 to +900-200 to +482 Type B T/C +212 to +3,272 +100 to +1,800 Type C T/C +32 to +4,208 0 to +2,320 Type E T/C -58 to +1,832-50 to +1,000 Type J T/C -292 to +1,382-180 to +750 Type K T/C -292 to +2,282-180 to +1,250 Type L T/C -328 to +1,652-200 to +900 Type N T/C +32 to +2,192 0 to +1,200 Type R T/C +32 to +2,912 0 to +1,600 Type S T/C +32 to +2,822 0 to +1,550 Type T T/C -238 to +752-150 to +400 Type U T/C -148 to +1,112-100 to +600 WIRELESS GENERAL SPECIFICATIONS Wireless Communication RF Transmit Power Data Rate Antenna Signal Range 902 MHz 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band. Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio. 31 mw, 17.8 mw typical. Configurable: 4.8 Kbps, 19.2 Kbps, or 76.8 Kbps. Omnidirectional Internal 3 omni-directional, ¼ wave, monopole. Up to 2000 feet (600 meters) from Base Radio with clear line of sight.* *Actual range may vary depending on site topography. Yagi Directional Length: 18. Gain: 6 dbd. Weight: 1.5 lbs. Polarization: Vertical. Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.* SITE SURVEY TOOLS RSSI Received Signal Strength Indicator displays the RF signal strength in one of seven ranges. Link Test Link Test measures the wireless link performance of a transmitter running in normal operating mode. This function looks at wireless performance in both directions, from the transmitter to base radio and vice versa and assigns a rating to that performance or quality of signal. FEATURES Automatic Retransmit The field unit checks with the base radio to insure successful receipt of data. If data was not received, the transmitter retries on the next RF cycle. Ensures communication confidence in the harshest of industrial environments. At the maximum transmit rate this feature is inactive. Page 2 of 9

SELF DIAGNOSTICS Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage. OPERATING/STORAGE CONDITIONS Humidity Temperature Ambient Sensor: Ambient Electronics: Process fluid: Display (Full visibility): Display (Reduced visibility): Storage: 95% RH (non-condensing). -40 to +230 F (-40 to +110 C) -40 to +185 F (-40 to +85 C) -40 to +250 F (-40 to +121 C) -4 to +158 F (-20 to +70 C) -40 to +185 F (-40 to +85 C) -58 to +185 F (-50 to +85 C). DISCRETE INPUTS (OPTIONAL) Discrete Input Switch (Dry Contact Only, no Voltage or Current Allowed) Maximum Impedance at Input 1 K ohm. Isolation 110 K ohms between Output (-) and Input (-). Wiring Warning Plug Wire Size 28 to 16 gauge maximum. No external voltage or current shall be applied to input terminals. Page 3 of 9

DEVICE CONFIGURATION Parameter Configuration RF Channel Setup: 1 to 16. Baud Rate: 4.8 Kbps, 19.2 Kbps, 76.8 Kbps. RF ID: 1 to 100. Password. Tag Name (up to 21 characters). Normal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Normal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec, 1 min). Abnormal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Abnormal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec). Temperature Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Temperature Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Engineering Units: Deg C, Deg F, Kelvin, Rankin. Probe Type. (WT531R will accept one RTD probe; WT531T will accept one or two T/C probes). Offset: User defined offset will be transmitted instead of actual value. Trim: Applies a user-defined one- or two-point correction curve to the actual value. Discrete Input parameters configured from the Wireless Management Toolkit Configuration Panel Integrated LCD display with membrane switch buttons for local configuration. LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome. Display cycles between temperature level and RF status. PERFORMANCE Accuracy ± 0.1% of full scale reading at operating conditions. For cold junction compensation (T/C only), add 1.8 F (± 1 C) at reference conditions. Linearization RTD and T/C linearization to ± 0.09 F (± 0.05 C). Custom linearization with 22 point curve. Ambient Temperature Effect RTD - ± 0.002% of reading per C T/C - ± 0.01% of reading per C Long Term Stability Stability deviation per year is less than 0.025%. Page 4 of 9

PHYSICAL SPECIFICATIONS Thermowell Material Electronic Housing Process connections Vibration and Shock Random Vibration Net weight Electromagnetic Compatibility (CE Compliance) 304 SS, 316 SS. GE Lexan. V0 Rating and UV Stable. ½ - NPTM for probe only. ¾ - NPTM for well. Certified per IEC EN00068 2-6 (Vibration) and 2-27 (Shock) Certified to withstand 6 g s, 15 minutes per axis from 9 500 Hz. With Omnidirectional antenna With Yagi directional antenna 1.0 kg (2 lbs) 1.8 kg (3.5 lbs.) Operates within Specifications in fields from 80 to 1,000 MHz with Field Strengths to 10 V/m. Meets EN 50082-1 General Immunity Standard and EN 55011 Compatibility Emissions Standard. APPROVALS Environmental protection NEMA 4, IP 65. Combined FM/CSA FM Explosion proof - Class I, Div. 1, Groups B,C,D, T5,T6, Enclosure 4X Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5,T6, Enclosure 4 CSA - Explosion proof - Class I, Div. 1, Groups B,C,D, T5, Enclosure 4X Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5, Enclosure 4 Combined CE/ATEX CE EMC Conformity, ETSI EN 300 489-1 Intrinsically Safe, Zone 0/1: Ex II 1 G EEx ia IIC T4, T5, T6 Non-Sparking, Zone 2: Ex II 3 G EEx na, IIC T6 Page 5 of 9

DIMENSIONS 97.5 3.84 97.5 3.84 97.5 3.84 97.5 189 116 4.59 297.6 11.72 mm inches 584mm 23 322.5mm 12.7 Page 6 of 9

Model Selection Guide Model Selection Guide 34-XY-16-02 Issue 10 Instructions Select the desired key number. Key Number I (Options) II (Approvals) - - KEY NUMBER Description Wireless Temperature Transmitter - Split Architecture with Omni Directional Antenna Single input - 4-wire RTD required (4-wire RTD supplied by customer) Wireless Temperature Transmitter - Split Architecture with Omni Directional Antenna Thermocouple(s) supplied by customer Wireless Temperature Transmitter - Split Architecture with Yagi Antenna Single input - 4-wire RTD required (4-wire RTD supplied by customer) Wireless Temperature Transmitter - Split Architecture with Yagi Antenna Thermocouple(s) supplied by customer Selection WT531R WT531T WT534R WT534T Availability TABLE I - OPTIONS No Discrete input/output switches XX Discrete Inputs (Note 1) DA Note 1 - no voltage or current allowed; dry contact only TABLE II - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Nonincendive CL II, III, Div 2, Groups F,G, T4; Combined CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X AG FM & CSA Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T3; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Nonincendive CL II, III, Div 2, Groups F,G, T3; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 ATEX* Int. Safe, Zone 0/1, or Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 3G Non-Sparking, Zone 2 Enclosure IP 65 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [?] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. b b RESTRICTIONS Restriction Letter Available Only With Not Available With Table Selection Table Selection b Mutually exclusive - select one Page 7 of 9

Model Selection Guide 34-XY-16-02 Issue 10 Instructions Select the desired key number. The arrow to the right marks the selection available. Make six selections from Table I. Key Number I II (Approvals) _ - _ - KEY NUMBER Description Wireless Temperature Transmitter - Integrated Complete Selection WT532 Availability TABLE I - PROBE Probe Type RTD R _ c Thermocouple T _ d Process connection Spring Loaded Fitting Direct Insertion Weld _ S _ D Probe Lag Hardware Nipple Nipple/Union/Nipple N _ Length (Select From Enter Length (y) From Sizing Table 1 Sizing Table I) Probe Type (Select From Enter Probe Type (z) from Probe Table 2 Probe Table 2 Thermowell (3/4" NPT) (Insertion Length = Probe Length minus 1.5") Example: WT532-RSNJPA 304 SS 316 SS No well TABLE II - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Combined FM & CSA Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Gp F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X b Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Gp F,G, T4; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 ATEX* Int. Safe, Zone 0/1, or Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 Non-Sparking, Zone 2 Enclosure IP 65 U Y Z A _ B _ C AG 3G * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [?] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. Page 8 of 9

RESTRICTIONS Restriction Letter c d b Table Ic & ld Available Only With Selection P Mutually exclusive - select one Table lc & ld Not Available With Selection P Sizing Table 1 Probe Table 2 Select option based on required Select option based on required probe length and enter option probe type and enter option in Table Ic in Table Id Probe length Option Probe type Option 2.5 y = A RTD z = P 3.0 y = B T/C 3.5 y = C B z = B 4.0 y = E C z = C 4.5 y = F E z = E 5.0 y = G J z = J 5.5 y = H K z = K 6.0 y = J L z = L 6.5 y = K N z = N 7.0 y = L R z = R 7.5 y = M S z = S 8.0 y = N T z = T 8.5 y = P U z = U 9.0 y = R 9.5 y = S 10.0 y = T 10.5 y = U 11.0 y = V 11.5 y = W 12.0 y = Y Industrial Measurement and Control Honeywell International Inc. 2500 West Union Hills Drive Phoenix, Arizona 85027 Honeywell International Inc. Page 9 of 9