Chloride. FP-50z 5 160kVA Industrial AC UPS

Similar documents
Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Gutor PxW AC UPS Designed for North American Market

TECHNICAL DATA SHEET B9600FXS kva

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

TOSHIBA International Corp

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

GESS Industrial UPS System. Overview

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

Est Static Frequency Converter. SFX 10kVA - 10MVA

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

R&D TECHNICAL SPECIFI

Power Processor - Series 700F 10KVA to 150KVA

Chloride FP-60Z 5 to 60kVA

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

Dale Power Solutions Ltd

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

B9000 FXS kVA B9600 FXS kVA

Est Static Frequency Converter. SFX 10kVA - 10MVA

MAJORSINE Power Inverter

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

StatiVolt. Inverter UPS Systems. Features. Contents

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC


ALL PRODUCT BROCHURE

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

MGETM EPSTM /625/750/800 kva. Three phase UPS

S11 Adjustable Speed Drive Engineering Specification

SHORE TO SHIP FREQUENCY

The world is changing but our power is constant...

Large-Capacity, High-Efficiency 3-Level UPS for North America 7000HX-T3U

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

EL-AC Electronic Load

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Technical Specifications

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Meduim Voltage Drives

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Uninterruptible Power System (UPS) 20 to 320 kva

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

UPS Uninterruptible Power System

Introduction: TAS PowerTek Ltd. MAVROS

ahead of time SAG Compensator

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load

Please note and refer to warning marks which you will find in the unit.

Introduction DIN rail mounted electricity meters

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

Orbital GFI Inverter Series

22 kw 4Q POWER AMPLIFIER RS232

SPECIFICATIONS. Input Output Approvals

Advanced, accurate and intelligent monitoring for your transformer

UNINTERRUPTIBLE POWER SUPPLY SINGLE MODULE SYSTEM SPECIFICATIONS MODEL 9800AE

Speed and Key Monitor Specifications

N. TEST TEST DESCRIPTION

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

GTI Series Inverters User Manual

SENTINEL XR PLUS 5-10kVA

Programmable AC Power Source Model 9801

RS232. DC POWER SUPPLY 20kW 3 RANGES

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

NGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

N. TEST TEST DESCRIPTION

ND40 - POWER NETWORK ANALYZER /RECORDER

NAME OF (VENDOR/MANUFACTURER) Clause No. Clause Description Comments, if any Remarks, if any

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

MT 560/UMT TRANSDUCER & ANALYZER

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

Series PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10

Transcription:

Chloride FP-50z 5 160kVA Industrial AC UPS

CHLORIDE FP-50Z Features yfully digital UPS solution for industrial applications yrobust design ensure high reliability features yuser-friendly display ydesign and temperature features for industrial Feature-rich Industrial AC UPS system embedded with the latest technologies for optimal power protection and reliability The Chloride FP-50z of Vertiv is an Industrial AC UPS system which is designed to meet a wide array of mission critical continuity needs in an industrial environment. It is embedded with the latest technologies available in the market today to provide your business maximum power protection even in the harshest conditions. yzero Transfer time ygalvanic isolation features ystate of the art mechanical Assembly design for ease of maintenance yparallel redundant configuration yfully customizable yexternal communication capabilities ycustomized designs to suit IP protection requirements APPLICATIONS ymanufacturing: Pharmaceutical, Textile, Retail ypower Generation, yt&d Oil and Gas ytransportation ycement plants ysteel Plants ychemical & Fertilizer 2

A fully digital Industrial UPS system yeasy System configuration through software for on-site modification and retrofitting needs ystate of the art SPWM Technology with digital control ensure low electrical noise for the loads/ appliances ya fast transient response ybetter voltage regulation ylow total harmonic distortion (THD) yeasy navigation yevent log for analysis of fault occurrence and easier maintenance yfp50z-3x1- Input, Battery, Output, Bypass per Group 170, i.e. total 680 event logs; In FP50z-3X3 --:- 254 event logs ypush button system control y2 lines of 20 characters display yenglish & Chinese language display Robust mechanical design for easy maintenance ystate of art front access for a more efficient maintenance yif necessary, side and rear panels are removable yfan replacement from front or top yeasy access to Thyristors, IGBTs, PCBs Connectivity Options yups MON-II (RS232 or ETHERNET based) ysnmp (RJ45) ymodbus (RS 485) yethernet based remote monitoring (i-remote) International standards compliant yiec / EN 62040 1 : Safety yiec / EN 62040 2 : Electromagnetic compatibility yiec / EN 62040 3 : Performance & testing yiso 9001 : 2008 : Quality System High reliability features y15 to 20 years product lifespan, supported by recommend preventive maintenance Design & temperature yfull output rated continuous operating temperature 400C yimproved thermal design with ventilation ensures improve in MTBF of the components Transfer time ysafe transfer to bypass, without a break for the connected load y0 s when synchronized on reserve y<10 ms transfer time in Async mode Galvanic isolation features yany mains disturbance will not be transferred to the DC circuit or to the output yload remains safe all the time irrespective of switching/transient in the Mains and sudden other output load changes in the O/P ACBD ydouble conversion topology provides clean and reliable power Parallel redundant configuration yfor 1 Phase up to 3 units in parallel yimmediate communication between the paralleled systems after connection yno single point of failure yactive load sharing Customization Capability ycustomized UPS configurations offered at pre-sales stage yfully custom built options meet required output power, voltage levels as well as available input power and voltage quality levels ycustomer requirements like color, protection, PFC etc. ycustomized accessories like ACDB, SCVS, Cell Booster yoption of input passive filter for PF & THDi improvement ybattery charging requirements yextended temperature up to 500C yseismic qualification 3

CHLORIDE FP-50Z Technical Specifications MODEL STANDARD OFFERINGS OPTIONAL INPUT Nominal Voltage 415 VAC, 3 Phase, 3 wire ( +10 %, -20 % ); Input Voltage range of 380/400 220 VAC 3 Phase 3 wire (+ 10 %, -15 % ) Nominal Frequency 50 Hz (± 10 %) 60 Hz (± 6 %) Input Power factor Input Fault Level RECTIFIER 0.88 up to 7.5 kva and 0.92 for 10 kva and above 0.96 10 ka y50 ka (MCCB) yinput Isolation Transformer (1) Type Full Wave, A-PFC Rectifier 12 Pulse, above 20 kva Rating CHARGER Type Nominal Voltage Regulation Ripple (without Battery) Charging Method BATTERY Battery Voltage Type yigbt based Dual mode of charging ysuitable to charge VRLA-SMF, Lead Acid, Ni-Cd battery ± 1 % - < 2 % - Constant Voltage Constant Current (CVCC) Auto & Manual with 0 to 24 Hr programmable timer y240 VDC for 5 to 15 kva 200-320V y300 VDC for 20 kva 255V - 350VDC y360 VDC for 30-120 kva 290V - 460VDC Note : +2 Blocks of 12 V and -1 Block of 12V possible Ni-Cd / Tubular / VRLA y110 VDC (5-15 kva UPS) 94V - 160V y220 VDC (20-120 kva UPS) 189V - 292V Battery Charging Capacity 5 to 10 kva Up to 15 A 15 to 20 kva Up to 20 A 30 to 40 kva Up to 30 A 50 & 80 kva Up to 40 A 60 kva Up to 55 A 100 to160 kva Up to 60 A 2 to 20 kva 40 A at 110 VDC 2 to 20 kva 20 A at 220 VDC 25 to 80 kva 60 A at 220 VDC As per Customer request (2) Protection Battery Breaker, Reverse Battery Indication Reverse Polarity, Battery Earth Fault

OUTPUT Nominal Voltage Load PF Support Capacity 220V / 230V / 240V AC (Step less Adjustable) 0.6 to Unity (within its kva / kw rating) 110V / 115V / 120V AC Voltage Regulation ± 1 % for 230 VAC ± 2 % for 110 VAC Frequency Waveform Total Harmonic Distortion Overload Capacity Duty Inverter Philosophy Dynamic Response Crest Factor 3 : 1 STATIC SWITCH Frequency Synchronisation Slew Rate Transfer (Inverter to Bypass) Re-transfer (Bypass to Inverter) Overload Capacity Manual Bypass Operation System Configuration y50 Hz (± 0.1 Hz) in Free Running Mode y± 5 % (± 1 to 5 % adjustable) in Synchronous mode True Sine Wave < 2 % Max. for 100 % Linear Load < 5 % Max. for 100 % Non-Linear Load ( IEC 62040 3 ) 110% for 60 min, 125% for 10 min., 150% for 1 min Continuous IGBT based PWM with INSTANTANEOUS sine wave control For 0 to 100 % step load change, the output shall remain within ± 5 % and recover to 98 % within 1 cycle ( IEC 62040 3, Class 1 ) ± 2.5 Hz 0.2 Hz/Sec yin Sync mode No break in transfer yin ASync mode < 10 ms yin Sync mode No break in re-transfer yin ASync mode Not applicable 1000 % for 100 ms Make Before Break Standalone 60 Hz (± 0.1 Hz) yparallel Redundant with separate batt bank yhot Stand by

CHLORIDE FP-50Z PHYSICAL Enclosure Protection IP 41 IP 42 Colour Paint Thickness & Type Cooling RAL 7021 Structure Finish 90 micron (± 10 micron ) Epoxy Powder Coated Forced Air Cable Entry Bottom Top Wound Components GENERAL SPECIFICATIONS Operating Temperature Relative Humidity Storage Temperature Utility Socket Class of Insulation Class H (Transformer / Inductor) 0 to 45 0 C (5-20 kva) 0 to 40 0 C (30-120 kva) 0 to 95% (Non-condensing) 0 to 50 0C 230 V / 5 A RAL 7021 / RAL 7032 / IS 5 631/ RAL 9001 Structure or as per customer requirement Up to 50 0 C (2) Illumination Lamp 11 W CFL Space Heaters Earth Busbar (Ref.IS 3043) PFCs Remote Panel UPS Monitoring Software y5-20 kva: 3 x 25 mm CU 3 x 25 mm CU y30-40 kva: 3 x 25 mm CU 3 x 25 mm CU (Earth bus bar running along the panel) y50-120 kva: 6 x 50 mm copper (Earth bus bar running along the panel) One relay contact for each (Rating 250 VAC, 1 A) ypfc with 250 V, 2 A / 6 A rating ytransducer 4 to 20 ma (As per Customer Specifications) With LCD (Ethernet Connectivity) yupsmon II ysnmp, MODBUS Connectivity RS 232 / RS 485 Ethernet / RS 485

VertivCo.com 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. Chloride-FP50z-BR-EN-ASIA-v2