DIGITAL PANEL METER N24 AND N25 METER SERIES

Similar documents
N24, N25 DIGITAL PANEL METER

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

SEPARATOR P20G TYPE USER S MANUAL

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

TEMPERATURE CONTROLLER RE21 TYPE

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

POWER CONTROLLER RP1 type

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

TRANSDUCER OF NETWORK PARAMETERS P43 TYPE

TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL

TEMPERATURE CONTROLLER. MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL

High power radio transmission module MR03 type

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

N E W functions! Modbus. Wireless transmission - SM ma TCP IP ma. NA5 meter with bargraph. k *

N30P DIGITAL PANEL METER

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

THREE-PHASE POWER CONTROLLER RP3 Type

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

RE92. CHECKMATE. Dual loop controller for industry purpose.

4-CHANNEL MODULE OF ANALOG INPUTS SM2 TYPE

OPTITEMP TT 20 Technical Datasheet

POWER NETWORK PARAMETER METER N13 SERVICE MANUAL

DIGEM f 96 x 48 EK. Applications. Description

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Thermocouple - Transducer

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

AC/DC Current Oscilloscope Probe Model SL261

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

TEMPERATURE CONTROLLER 48 x 48 mm RE70 TYPE USER S MANUAL

SINEAX V 604s Programmable multifunctional transmitter

Operating Manual MU2000K

Process displays For standard signals, temperature, resistance measurement

DM-45 Digital Multimeter

I Pr I P I OUT R L. Applications. Standards

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

P5201 Universal Programmable Transmitters with Galvanic Isolation

OPTITEMP TT 10 C/R Technical Datasheet

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Paperless Recorder PR20

UNIVERSAL CONTROLLER RE62

EA16, EB16, EA17, EA19

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Temperature transmitter itemp PCP DIN rail TMT 121

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Temperature Input Module for Zone 1 Series 9482/32

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

USER S MANUAL. Rail-mounted temperature transmitter ATL

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX U 553 Transducer for AC Voltage

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

High-precision process calibrator Model CED7000

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

AMM-1022 Digital Multimeter USER`S MANUAL

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Temperature measurement TMD 832 head transmitter

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

DIGITAL PANEL INSTRUMENTS

itemp PA TMT184 Technical information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

installation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)

METRAClip87 and 88 Clamp Multimeters

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Operating Instruction

Temperature head transmitter itemp PCP TMT 181

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ANALOG PANEL METERS. Moving-iron meters EB16 EA16 EA17 EA19 EA12. Moving-coil meters with rectifiers MA17P MA19P MA12P. 3-phase voltmeters

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting

CLAMP-ON METER 670. User Manual

MINI MCR-SL-UI-I-LP-NC

Digital indicator for panel mounting With multi-function input Model DI25

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Isolators A3/1.

BENNING. CM7 Electrical Tester. Service Information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

itemp HART DIN rail TMT112

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Computer-14d - xx - 144a

AC/DC Current Probes Model MR411 Model MR521

Temperature Measurement

VariTrans P V. Safe and Sound.

B850 Boiler House Energy Monitor

GAMMA 10 DIGITAL MULTIMETER

Transcription:

DIGITAL PANEL METER N24 AND N25 METER SERIES USER S MANUAL

Contents 1. APPLICATION...5 2. METER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1 Fixing Way...7 4.2 External Connection Diagrams...8 5. SERVICE...10 5.1 Display Description...10 5.2 Messages after Switching the Supply on...10 5.3 Meter Configuration by Means of LPCon Program...11 5.4 Manufacturer s Parameters of N24S, N25S...12 5.5 Manufacturer s parameters of N24T, N25T...12 5.6 Manufacturer s Parameters of N24Z, N25Z...13 5.7 Manufacturer s Parameters of N24H, N25H...14 6. ERROR CODES...15 7. TECHNICAL DATA...15 7.1 Technical Data of N24S, N25S...15 7.2 Technical Data of N24T, N25T...16 7.3 Technical Data of N24Z, N25Z...17 7.4 Technical Data of N24H, N25H...17 7.5 Common Technical Data for the Whole N24 and N25 Series...18 8. ORDER CODES...20 9. SERVICE AND MAINTENANCE...23

1. APPLICATION Meters of the N24 and N25 series are digital instruments destined for the measurement of d.c. voltage or d.c. current: uni or bipolar, temperature through J, K thermocouples, Pt100 resistance thermometers and for the measurement of a.c. voltage and a.c. current. A LED display (4 digits for N24 and 5 digits for N25 meter series) constitutes the readout field. The LPCon program is destined for the configuration of N24 and N25 meter series. One must connect the meter with the PC computer through the PD14 programmer. Following parameters can be reprogrammed: - thresholds of displayed overflows, - precision of the displayed result (decimal point), - measurement averaging time, - counting of indications (individual characteristic), - automatic or manual compensation: cold junction temperature for measurements with thermocouples, or wire resistance for Pt100 measurements (only in N24T and N24S meters). All meters are galvanically separated between the supply, measuring inputs and the programmer input Protection grade from the frontal side: IP65. Meter overall dimensions: 96 x 48 x 64 mm (with terminals). 2. METER SET The set is composed of: Meter types: N24 or N25...1 pc User s manual...1 pc Guarantee card...1 pc Clamps to fix in the panel...4 pcs Seal...1 pc When unpacking the meter, please check whether the type and execution code on the data plate correspond to the order. If equipment is

incomplete or appears to be damaged, file immediately a claim with the carrier and notify the sender at once. 3. BASIC REQUIREMENTS, OPERATIONAL SAFETY In the safety service scope, the meter meets the requirements of the EN 61010-1 standard. Meaning of the symbol: Caution: risk of hazard. Observations concerning the operational safety All operations concerning transport, installation, and commissioning as well as maintenance, must be carried out by qualified, skilled personnel, and national regulations for the prevention of accidents must be observed. The programming of N24 and N25 meter series parameters must be carried out after disconnecting measuring circuits Before switching the meter on, one must check the correctness of connections to the network. Do not connect the meter to the network through an autotransformer. Before removing the meter housing, one must switch the supply off and disconnect measuring circuits. The removal of the meter housing during the guarantee contract period may cause its cancellation. The meter fulfills requirements related to electromagnetic compatibility and can be used in the industrial electromagnetic environment When connecting the supply, one must remember that a switch or a circuit-breaker should be installed in the building. This switch should be located near the device, easy accessible by the operator, and suitably marked as an element switching the meter off. Non-authorized removal of the housing, inappropriate use, incorrect installation or operation, creates the risk of injury to personnel or meter damage. For more detailed information, please study the User s Manual.

4. INSTALLATION 4.1. Fixing Way The meter has separable strips with screw terminals which enable the connection of external wires of 2.5 mm 2 cross-section. In execution for current measurement, the plug enables a permanent fixing to the socket by means of screws. The meter is adapted to be mounted in a panel by means of clamps, acc. to the fig. 1. One must prepare a hole of 92 +0,6 45 +0,6 mm in the panel which the thickness should not exceed 6 mm. The meter must be introduced from the panel front with disconnected supply voltage. Before the insertion into the panel, one must check the correct placement of the seal. After the insertion into the hole, fix the meter by means of clamps (fig.1). Fig. 1. Meter fixing Fig. 2. Overall dimensions

4.2. External Connection Diagrams 4.2.1 Electrical Connections of the N24S and N25S Meters Fig. 3. Electrical connection of the N24S, N25S meters 4.2.2 Electrical Connection of the N24T and N25T Meter Fig. 4. Electrical connection of the N24T, N25T meters

Resistance thermometer in a two-wire system and with manual compensation Resistance thermometer in a three-wire system and with automatic compensation Thermocouple J, K Fig. 5. Connections of the N24T and N25 T measuring inputs 4.2.3 Electrical Connections N24Z, N24H and N25Z, N25H Meters Fig. 6. Electrical connections of N24Z, N24H and N25Z, N25H meters for the measurement of voltage (and frequency measurement only for the N24Z and N25Z meters) Fig. 7. Electrical connections of N24Z, N25Z and N24H, N25H meters for the current measurement.

5. SERVICE 5.1. Display Description Measured value Fig. 8. Frontal panel 5.2. Messages after Switching the Supply on After switching the supply on, the meter displays the meter name appropriate to the kind of measured signal: N24e, N25E where E is the appropriate execution of the s,t,2,h. meter and next, the program version in the shape r x.xx where x.xx is the number of the current program version or the number of a custom-made execution. Till the time to obtain the required number of correct measurements (acc. to the table 1 for N24S, N24T, N24H, N25S, N25T, N25H meters or acc. to the table 2 for N24Z and N25Z meters) the arithmetical mean value from until now measurements is displayed. The measurement of a value 10

from behind the measuring range causes the setting of the overflow and the beginning of the counting of correct measurements again. The time is set by the manufacturer on 1 sec. Table 1 Averaging time 0,5 s 1 s 3 s 5 s 10 s 15 s 20 s Number of averaged measurements Updating of the value on the display 2 7 20 33 67 100 133 0,5 s 0,5 s 0,5 s 0,5 s 0,5 s 0,5 s 0,5 s Table 2 Averaging time 0,5s 1s 3s 5s 10s 15s 30s 1 m 2 m 5 m 7 m 12 m 15 m Number of averaged measurements Updating of the value on the display 1 2 6 10 20 30 60 100 100 100 100 100 100 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 0,5s 9,1s In case of any error occurrence or exceeding of the range value, one of the message described in the section 6 will be displayed. 5.3. Meter Configuration by Means of the LPCon Program The free delivered LPCon program, available on the www.lumel.com.pl page, is destined for the N24 and N25 meter series configuration. The configuration user s manual for N24 and 25 meters by means of the LPCon program is also available on the www.lumel.com.pl page. The PD14 programmer is required for the configuration. CAUTION! The programming of meter parameters must be carried out when measuring circuits are switched off! 11

5.4. Manufacturer s Parameters of N24S and N25S Meters Table 3 Parameter description Range/value (N24/N25) Manufacturer s value N24S Manufacturer s value N25S Decimal point Averaging time Individual characteristic Parameter a of the individual characteristic Parameter b of the individual characteristic Upper overflow of the measurement Lower overflow of the measurement 0000, 000.0, 00.00, 0.000/00000, 0000.0, 000.00, 00.000, 0.0000 0.5 s; 1 s; 3 s; 5 s; 10 s; 15 s; 20 s; 00.00 for U,I unipolar; 000.0 for U bipolar; 000.00 for U,I unipolar; 0000.0 for U bipolar; 1 s 1 s disabled, enabled disabled disabled -99999...99999 1 1-99999...99999 0 0-1999...9999/ -19999...99999-19999...9999/ -19999...99999 9999 99999-1999 -19999 5.5. Manufacturer s Parameters of N24T and N25T Meters Parameter description Decimal point Averaging time Individual characteristic Parameter a of the individual characteristic 12 Range/value (N24/N25) 0000, 000.0, 00.00, 0.000/00000, 0000.0, 000.00, 00.000, 0.0000 0.5 s; 1 s; 3 s; 5 s; 10 s; 15 s; 20 s; Manufacturer s value N24T 0000 for J and K thermocouples, 000.0 for Pt100 Table 4 Manufacturer s value N25T 00000 for J and K thermocouples, 0000.0 for Pt100 1 s 1 s disabled, enabled disabled disabled -99999...99999 1 1

Parameter b of the individual characteristic Automatic compensation of terminal temperature/wire resistance Value of manual compensation: terminal temperature/wire resistance Upper overflow of the measurement Lower overflow of the measurement -99999...99999 0 0 disabled, enabled disabled disabled -20...60 C/0...20 W 40 C/0 W 40 C/0 W -1999...9999/ -19999...99999-1999...9999/ -19999...99999 9999 99999-1999 -19999 5.6. Manufacturer s Parameters of N24Z and N25Z Meters Parameter description Range/value (N24/N25) Manufacturer s value N24Z Table 5 Manufacturer s value N25Z Decimal point Averaging time Individual characteristic Parameter a of the individual characteristic Parameter b of the individual characteristic Upper overflow of the measurement Lower overflow of the measurement 0000, 000.0, 00.00, 0.000/00000, 0000.0, 000.00, 00.000, 0.0000 0.5 s; 1 s; 3 s; 5 s; 10 s; 15 s; 30 s; 1 min; 2 min; 5 min; 7 min; 12 min; 15 min 000.0 for U,f 0.000 for I 0000.0 for U,f 0000.0 for I 1 s 1 s disabled, enabled disabled disabled -99999...99999 1 1-99999...99999 0 0-1999...9999/ -19999...99999-19999...9999/ -19999...99999 9999 99999-1999 -19999 13

5.7. Manufacturer s Parameters of N24H and N25H Meters Table 6 Parameter description Range/value (N24/N25) Manufacturer s value N24H Manufacturer s value N25H Decimal point Averaging time Individual characteristic Parameter a of the individual characteristic 0000, 000.0, 00.00, 0.000/00000, 0000.0, 000.00, 00.000, 0.0000 0.5 s; 1 s; 3 s; 5 s; 10 s; 15 s; 20 s; 0000 for U or 00.00 for I bipolar 000.0 for U unipolar 0000.0 for U or 000.00 for I 1 s 1 s disabled, enabled disabled disabled -99999...99999 1 1 Parameter b of the individual characteristic -99999...99999 0 0 Upper overflow of the measurement Lower overflow of the measurement -1999...9999/ -19999...99999-19999...9999/ -19999...99999 9999 99999-1999 -19999 14

6. ERROR CODES After switching the meter to the network on, messages about errors can appear. Messages about errors and their reasons are presented below.,, ErCA ErEE Overflow of the upper value of programmed indication range. In the option with Pt100, this message also signals incorrect connections of the wire to the terminal 4. Overflow of the lower value of programmed indication range. Loss of meter calibration values. In such a case, one must contact the service workshop. Incorrect values in the meter configuration data. One must set up again meter parameters by means of the LPCon program. 7. TECHNICAL DATA 7.1. Technical Data of N24S and N25S Meters Measuring range: INPUTS: Measuring range of voltage Un: -11 mv...-10 mv...60 mv...66 mv -66 mv...-60 mv...60 mv...66 mv -0.5 V...0 V...10 V...11 V -11 V...-10 V...10 V...11 V input resistance > 1 MΩ Measuring range of current In: -1 ma...0 ma...20 ma...22 ma input resistance 10 Ω ± 1% 3.6 ma...4 ma...20 ma...22 ma input resistance 10 Ω ± 1% Basic error (at manufacturer s settings): ± (0.2% of the range + 1 digit) 15

Output for supply external transducers Sustained overload Short duration overload (1 s): 24 V ± 5% 30 ma 110% Un, 110% In voltage input 10 Un current input 5 In 7.2. Technical Data of N24T and N25T Meters Measuring range: INPUTS: Pomiar temperatury Pt100: -50 C...150 C -50 C...400 C Resistance of wires connecting the resistance: Temperature measurement by thermocouple of J type: Temperature measurement by thermocouple of K type: Basic error (at manufacturer s settings): Additional errors in rated operating conditions: - compensation of cold junction temperature changes - compensation of wire resistance changes Output for the supply of external transducers Short duration overload (1 s): 16 current flowing through the sensor < 300 ma 5 W by wire for the automatic compensation 10 W by wire for the manual compensation - 50 C...1200 C - 50 C...1370 C ± (0.2% of the range + 1 digit) ± 0.2% of the range ± 0.2% of the range 24 V ± 5% 30 ma inputs of sensors: 30 V

7.3. Technical Data of N24Z and N25Z meters Measuring range: INPUTS: Measuring range of voltage Un: 1...100...120 V a.c. 2.5...250...300 V a.c. input resistance > 2 MΩ 4...400...600 V a.c. Measuring range of current In: 0.01...1...1,2 A a.c. input resistance 10 mω ±10% 0.05...5...6 A a.c. input resistance 2 mω ±10% Measurement of frequency 20...500 Hz (in voltage range 24...480 V) input resistance > 2 MΩ Basic error (at manufacturer s settings): - voltage and current: ± (0.5% of the range + 1 digit) in frequency interval 20...500 Hz - frequency: ± (0.02% of the range + 1 digit) Sustained overload Short duration overload (1 s) 150% Un (only for 400 V input), 120% Un (for other Un), 120% In voltage input 2 Un (< 1000 V), current input 10 In 7.4. Technical Data of N24H and N25H Meters Measuring range: INPUTS: Measuring range of unipolar voltage Un: 0...100...110 V d.c. 0...250...275 V d.c. input resistance > 2 MW 17

Measuring range of bipolar voltage Un: -120...-100...100...120 V d.c. -300...-250...250...300 V d.c. input resistance > 2 MW -600...-400...400...600 V d.c. Measuring range of bipolar current In: -1.2...-1...1...1.2 A d.c. input resistance 10 mω ±10% -6...-5...5...6 A d.c. input resistance 2 mω ±10% Basic error (at manufacturer s settings): - voltage and current: ± (0.2% of the range + 1 digit) Sustained overload: 150% Un (only for ± 400 V input), 120% Un (for other Un), 120% In Short duration overload (1s) voltage input 2 Un (<1000 V) current input 10 In 7.5. Common Technical Data for the Whole N24 and N25 Series Rated operating conditions: - supply voltage 230 V ± 10% a.c. (45...65 Hz) 110 V ± 10% a.c. (45...65 Hz) 24 V ± 10% a.c. (45...65 Hz) 85...253 V a.c. (45...65 Hz) or d.c. 20...40 V a.c. (45...65 Hz) or d.c. - ambient temperature -10...23...55 C - storage temperature - 25...+85 C - humidity < 95% (condensation inadmissible) - work position any 18

Additional errors in rated operating conditions: - from ambient temperature changes (50% of basic error/10 K) Averaging time (programmable) ³ 0.5 s (by default 1 s) Preheating time 30 minutes Readout field: 4-digit LED display (N24 series) 5-digit LED display (N25 series) - digit height 20 mm (N24)/14 mm (N25 series) - colour red - indication range: -1999...9999 (N24 series) -19999...99999 (N25 series) Ensured protection grade from the frontal side: IP 65 acc. to EN 60529 Overall dimensions: 96 x 48 x 64 mm (with terminals) Weight: < 0.25 kg Input power < 6 VA Galvanic isolation between: - supply-measuring input 3.2 kv d.c. Electromagnetic compatibility: - noise immunity acc. to EN 61000-6-2 - noise emission acc. to EN 61000-6-4 Safety requirements acc. to EN 61010-1: isolation between circuits: basic, installation category III (for the 400 V option category II), pollution grade: 2, maximal phase-to-earth working voltage: - for the supply circuit: 300 V, - for the measuring input 600 V category II (300 V cat. III) - for the programming input: 50 V altitude above sea level: < 2000 m, 19

8. ORDER CODES 20 Table 7 DIGITAL PANEL METER N2X X- X X XX XX X X Number of display digits: four (N24 series)... 4 five (N25 series)... 5 Kind of input signal: standard: voltage, current...... S temperature: thermocouples, resist. thermometers... T a.c. signals...... Z d.c. signals: high voltage, high current... H Input: see table 8...... X Supply: 230 V a.c.......... 1 110 V a.c.......... 2 24 V a.c.......... 3 85...253 V a.c./d.c. with supply output: 24 V/30 ma*... 4 20...40 V a.c./d.c. with supply output: 24 V/30 ma*... 5 Units: see table 9............ XX Version: standard............... 00 non-standard settings.................. NS custom-made **.................. XX Language: Polish.................. P English.................. E other**..................... X Acceptance tests: without extra quality inspection requirements........................ 0 with an extra quality inspection certificate..................... 1 acc. to customer s request **..................... X * This output is only in N2XS, and N2XT meters ** The code number is established by the manufacturer

Table 8 METER TYPE Item N24S/N25S N24T/N25T N24Z/N25Z N24H/N25H 1 0...20 ma PT100: -50...150 C 100 V a.c. +/- 100 V d.c. 2 4...20 ma PT100: -50...400 C 250 V a.c. +/- 250 V d.c. 3 0...60 mv 4 0...10 V Thermocouple J: -50... 1200 C Thermocouple K: -50... 1370 C 400 V a.c. +/- 400 V d.c. 1 A a.c. +/- 1 A d.c. 5 ± 60 mv 5 A a.c. +/- 5 A d.c. 6 ± 10 V frequency 20...500 Hz 0...100 V d.c. 7 0...250 V d.c. Codes of printed units Table 9 Code Unit Code Unit 00 without unit 08 kv 01 o C 09 Hz 02 % 10 turns 03 A 11 rpm 04 V 12 bar 05 mv 13 kpa 06 ma 14 MPa 07 ka XX on order 1) 1) After agreeing with the manufacturer. 21

EXAMPLES OF ORDER: Example 1 The code: N24Z - 2 1 04 00 E 0 means: N24Z digital meter with four digits for a.c. signals, 2 input signal: 250 V a.c. (acc. to the table 8), 1 supply voltage: 230 V a.c., 04 with the unit: V (acc. to the table 9), 00 standard version, E English language, 0 without extra quality inspection requirements. Example 2 (custom-made version) The code: N25S - 1 4 02 XX E 1 means: N25S digital meter with 5 digits for d.c. signals 1 input signal: 0 20 ma (acc. to the table 8), 4 supply voltage: 85 253 V a.c., with the 24 V/30 ma supply input for external transducers, 02 with the unit: % (acc. to the table 9), with display indications: 0 100.0, XX custom-made, mentioned in the table 10, E English language, 1 with an extra quality inspection certificate. Example of additional information for non-standard settings Parameter Range/value Decimal point 000.00 Averaging time 1 s Upper measurement overflow 99999 Lower measurement overflow -19999 Individual characteristic enabled Parameter a of the individual characteristic 5 Parameter b of the individual characteristic 0 Table 10 22

9. MAINTENANCE AND GUARANTEE The N24 and N25 digital panel meter series do not require any periodical maintenance. In case of some incorrect operations: 1. During the Guarantee Period Defined in the Guarantee Card: One should take the meter down from the installation and return it to the Manufacturer s Quality Control Dept. If the meter has been used in compliance with the instructions, the Manufacturer warrants to repair it free of charge. 2. After the Guarantee Period: One should turn over the meter to repair it in a certified service workshop. The disassembling of the casing causes the cancellation of the granted guarantee. Our policy is one of continuous improvement and we reserve the right to make changes in design and specifications of any products as engineering advances or necessity requires and revise the above specifications without notice. 23

SALES PROGRAM MEASUREMENT DIGITAL and BARGRAPH PANEL METERS CONTROL MEASURING TRANSDUCERS RECORDING ANALOG PANEL METERS (DIN INSTRUMENTS) INDUSTRIAL PROCESS and POWER CONTROLLERS CHART and PAPERLESS RECORDERS 1-PHASE and 3-PHASE WATT-HOUR METERS LARGE SIZE DISPLAY PANELS ELEMENTS OF INTEGRATION SYSTEMS ACCESSORIES for MEASURING INSTRUMENTS (SHUNTS) CUSTOM-MADE PRODUCTS ACCORDING CUSTOMER S REQUIREMENTS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF: ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING and THERMOPLASTICS PARTS SUBCONTRACTING of ELECTRONIC DEVICES (SMT) PRESSURE CASTINGS and OTHER TOOLS QUALITY PROCEDURES: According ISO 9001 and ISO 14001 international requirements. All our instruments have CE mark. For more information, please write to or phone our Export Department. Lubuskie Zak³ady Aparatów Elektrycznych LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Góra - Poland tel.: (48-68) 329 51 00 (exchange) fax: (48-68) 329 51 01 e-mail: lumel@lumel.com.pl http://www.lumel.com.pl 24 Export Department: Tel.: (48-68) 329 53 02 or 53 04 Fax: (48-68) 325 40 91 e-mail: export@lumel.com.pl N24-07B/1