Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Similar documents
Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Solid-state Twin Timer

NPN PNP NPN PNP NPN PNP

Inductive Proximity Sensor

Self-powered Counter

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

CompoBus/D-type Digital Controller

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

High-precision Optical Switch

Distance-setting Photoelectric Sensor

Capacitive Proximity Sensor

Rectangular Proximity Sensor

3. Contact Form A: SPST-NO

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Count/Time Totalizers

Distance-setting Photoelectric Sensor

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

SPST-NO SPDT DPST-NO DPDT

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Safety Relay Unit. OFF-delay time

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Photoelectric Sensor

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

SPST-NO SPDT DPST-NO DPDT

Solid-state Timer H3DE

Solid-state Timer H3DS

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Phase-sequence Phase-loss Relay

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Process Meter. Applicable

Model Number Structure

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Surface-mounting Relay

Self-Powered Counters H7ET

Ultraminiature Photoelectric Switches with Self-contained Amplifier

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

EE-SX770/771/772/870/871/872(A/P/R)

Details on the New G2RS

Model Number Structure

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

A W - A 2A R - 24D - 1

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Built-in Amplifier Photoelectric Sensor

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

LED Displacement Sensor

Single-phase Voltage Relay

Built-in Amplifier Photoelectric Sensor

Model Number Structure

Model Number Structure

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Solid-state Timer H3DE

Solid-state Timer H3DS

Laser Displacement Sensor

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

FA Wireless SS Terminals

Model Number Structure

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

EE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes

onlinecomponents.com

Solid State Pressure Sensors D8M

Absolute Rotary Encoder E6C2-A

Model Number Structure

Remote Sensor Amplifier Terminal

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min


Single-phase Current Relay

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Long Range Metal Body Sensor

OMRON MK-I / -S RELAY

Multi-point Temperature Controller

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Transcription:

Digital Panel Meter Subminiature Digital Panel Meter that Accepts DC Input Ultra-compact DIN-size (48 x 24 (W x H)) body. Mounting thickness of only 2 mm required. Highly visible display with 10.2-mm-high LEDs. 5-VDC power supply for control. Water-resistant (IP51) construction (optional). Ordering Information Input Range Range Measuring ranges Supply voltage DC voltage +199.9 mv -V117 Model Number Legend - 1 2 3 4 1, 2. Input Code V1: +199.9 mv V2: +1.999 V V3: +19.99 V V4: +199.9 V +1.999 V -V217 +19.99 V -V317 +199.9 V -V417 Accessories (Order Separately) 5 VDC (not internally insulated) 3. Series No. 1: Current series 4. Supply Voltage 7: 5 VDC (not internally insulated) Name Appearance Model Water-resistive Soft Front Cover K32-L24SC 11

Application Examples High DC Voltage Measurement When voltage exceeding the maximum voltage in the standard range is measured (for example: more than 200 V), a divider is connected externally. Hi Divider Hi Input Lo R 1 E 1 R 2 E 2 Lo Digital panel meter DC (V) E 2 E 1 R 2 R 1 R 2 Specifications Ratings Supply voltage Operating voltage range Power consumption Insulation resistance Dielectric withstand voltage Noise immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity Ambient atmosphere 5 VDC (not internally insulated) 5% to +5% of supply voltage 0.3 W (at max. DC load) 10 MW min. (at 500 VDC) between external terminal and case 2,000 VAC min. for 1 min between external terminal and case +200 V on power supply terminals in normal mode +500 V on power supply terminals in common mode Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Malfunction: 100 m/s 2 (approx. 10G) for 3 times each in 6 directions Destruction: 300 m/s 2 (approx. 30G) for 3 times each in 6 directions Operating: 10% to 55%C (with no icing) Storage: 20% to 65%C (with no icing) Operating: 35% to 85% (with no condensation) Must be free of corrosive gas Characteristics Input signal A/D conversion method Sampling period Display refresh period DC voltage Double integral method 2.5 times/s 2.5 times/s Max. displayed digits 3 1/2 digits (+1999) Display Decimal point display position Sign display 7-segment LED By short-circuiting terminals Overflow/underflow display Overflow: 1 Underflow: 1 External control Enclosure ratings is displayed automatically with a negative input signal. Process value hold (terminals on rear panel short-circuited) Front panel: IEC IP51 (see note) Case: IEC IP20 Terminals: IEC IP00 IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive accessories. 12

Measuring Ranges Input range Measuring range Max. resolution Input impedance Accuracy Max. permissible load DC voltage +199.9 mv 100 mv 100 MW +0.1%rdg +1 digit +250 V +1.999 V 1 mv 100 MW +0.1%rdg +1 digit +250 V +19.99 V 10 mv 10 MW +0.1%rdg +1 digit +250 V +199.9 V 100 mv 10 MW +0.1%rdg +1 digit +350 V The above accuracy is at an ambient temperature of 25+5%C. Nomenclature PV display Select the decimal position with terminal 5, 6, or 7 on the rear panel. 10 3 10 2 10 1 Dimensions All units are in millimeters unless otherwise indicated. 45 45 24 21 48 2 70 Panel Cutouts 45 +0.6 0 LED Indicator Size 22.2 +0.3 0 38 min. 10.2 mm 5.6 mm 60 min. 13

Installation External Connections External Connection (Connector and connector screws are provided with the model.) 1 2 3 4 5 6 7 8 9 10 Unused + COM HOLD 10 3 10 2 10 1 Signal input Decimal position DC power supply 1. Terminals 2 and 3 and 10 are not internally insulated. Connect a relay with high contact reliability and insulation (with a minimum load current of 0.3 ma) or a photocoupler with high insulation (with a residual voltage of 1 V max. and a current leakage of 0.1 ma max.) to these terminals for external control. The use of an independent power supply is recommended for the Digital Panel Meter. 2. Terminal 8 is not used. Do not use this terminal for transmission of signals. Precautions Mounting Recommended panel thickness is 1 to 3.2 mm. Mount the Digital Panel Meter by attaching the mounting bracket supplied as an accessory from the rear of the Digital Panel Meter, hook the mounting bracket to the Digital Panel Meter securely, and tighten the mounting screws by turning them clockwise with a tightening torque of 4 kgf $ cm (0.39 N $ m). For dismounting, loosen the screws and widen the hooks. Always attach the Mounting Bracket before wiring the terminals. Also, always remove the wiring before removing the Mounting Bracket. Mount the Digital Panel Meter as horizontally as possible. Never use the Digital Panel Meter in locations where corrosive gas (particularly sulfureted or ammonia gas) is generated. As much as possible avoid use of the Digital Panel Meter in a location subject to severe shock or vibration, excessive dust, or excessive moisture. Select a mounting location where the Digital Panel Meter can be used at an ambient operating temperature 10% to 55%C. Calibration Calibrate the Digital Panel Meter regularly so that the Digital Panel Meter can maintain processing accuracy. Use a standard signal generator with an accuracy of 99.99% min. for calibration. For the precise calibration methods, refer to the Instruction Sheet for the Digital Panel Meter. Control Power Supply Use a control power supply with a ripple rate of 10% max. Accessories (Order Separately) Water-resistive Soft Front Cover Before mounting the Digital Panel Meter to a panel, attach the water-resistive soft front cover and mounting bracket to the Digital Panel Meter properly so that the Digital Panel Meter will maintain IP51 water-resistive standards. Mounting Adapter Soft Cover Be sure to use the Water-resistive Soft Front Cover and mounting bracket together. 14

K3TE/F/G K3TE/F/G ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. N74 E1 1 OMRON Corporation Supervisory Control Devices Division 29th Fl., Crystal Tower Bldg. 1 2 27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6075 Fax: 06-949-6084 16 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0592 1M (0592)