THE USE OF BU SERIES ACCELEROMETERS

Similar documents
Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Accelerometer ACH-01. Piezoelectric Accelerometer Wide Bandwidth; AC Coupled Ultra Low Power High G Ranges

AN5E Application Note

Wide Bandwidth, Low Noise, Precision Top Port SiSonic Microphone

CERAMIC SHEAR TUBE CONTACT TRANSDUCER MICROPHONE TECHNICAL MANUAL

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

INTER PLANT STANDARD STEEL INDUSTRY

MEASURING PSRR AND PSR+N ON THE APx525

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SE 120. Piezoresistive accelerometer

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Operating Manual. Model 832 & 832M1 Accelerometer

Product Specification for Reference Only

BOTTOM PORT SISONIC MICROPHONE

IPC-TM-650 TEST METHODS MANUAL

Model 526T Series II Super Punch Microphone User Guide

Models Z7, Z11, Z602WA and Z820WA Impedance head operating guide

TECHNICAL MANUAL ULTRASONIC TEST SET MODEL 42A12D JUNE 15, 1998 REV 00 SEACOM DIVISION

SCS SERIES INTRODUCTION

SiSonic TM Microphone

731A seismic accelerometer and P31 power unit/amplifier Operating guide

Piezo contact mic amplifier (original article)

26 Endevco Isotron accelerometers

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

A Simple Notch Type Harmonic Distortion Analyzer

Low Cost 100 g Single Axis Accelerometer with Analog Output ADXL190*

Current Transducer CTSR 1-P = 1A

Acceleration Sensor AS - 022

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276

Studio. PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SINGLE TURN COPAL ELECTRONICS S T T A Ω ( 1 2 ) FEATURES PART NUMBER DESIGNATION

Principles of Vibration Measurement and Analysis. Dr. Colin Novak, P.Eng July 29, 2015

THE ZEN TRIODE EXPIREMENTERS AMPLIFIER KIT MODEL SE84CDIYMONO

Accelerometer Sensors

Precision Top Port SiSonic TM Microphone

ICS High SPL Analog Microphone with Extended Low Frequency Response

Current Probes. User Manual

TABELA DE PREÇOS JANEIRO 2018

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

MXD6235Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial Charge Accelerometers Types 4326-A and 4326-A-001

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Zero Height Ultra Mini SiSonic Microphone Specification With MaxRF Protection Halogen Free PRELIMINARY

Knowles Acoustics 1151 Maplewood Drive Itasca, IL 60143

FL283. Dual 8 inch Subcardioid Line Array Module. product specification. Performance Specifications 1

ADXL311. Ultracompact ±2g Dual-Axis Accelerometer FEATURES FUNCTIONAL BLOCK DIAGRAM APPLICATIONS GENERAL DESCRIPTION

Capacitive Versus Thermal MEMS for High-Vibration Applications James Fennelly

The Aleph 2 is a monoblock 100 watt audio power amplifier which operates in single-ended class A mode.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MXD6125Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES

HIGH PERFORMANCE CAR AMPLIFIER

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

Marchand Electronics Inc.

A Custom Vibration Test Fixture Using a Subwoofer

NDT1-220K Ultrasonic Transducer

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

SEIKA SB2i-B. SB2i-B1 /B2 & B3 DC Acceleration. 4-20mA DC Acceleration

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

SCM-660 USER S GUIDE. Table of Contents:

Introduction to LIVM Accelerometers

Voltage transducer DVL 50

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM

SOLDERING TO TRANSDUCERS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MULTIMODE DIGITAL BOTTOM PORT SISONIC MICROPHONE

Application Specification Accelerometer ACH AUG 98 Rev A

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

9 db/oct, variable bass boost

ICS Ultra-Low Noise Microphone with Differential Output

G6ALU 20W FET PA Construction Information

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Knowles Acoustics 1151 Maplewood Drive Itasca, IL 60143

EXPERIMENT 2: STRAIN GAGE DYNAMIC TESTING

MEAS Silicon MEMS Piezoresistive Accelerometer and its Benefits

Very High Frequency Calibration of Laser Vibrometer up to 350 khz

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SMA100. Top Port Analog MEMS Microphone. Datasheet. Rev. 2.0

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Piezoelectric multilayer triaxial accelerometer

Bill of Materials: General Purpose Alarm, Pulsed PART NO

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements. Endevco technical paper 334

OPERATING GUIDE MODEL 3093M32 MINIATURE HIGH SENSITIVITY TRIAXIAL LIVM ACCELEROMETER WITH SINGLE 4-PIN CONNECTOR INTERNALLY CASE GROUND ISOLATED

VXR S SERIES 1.0 DESCRIPTION 1.1 FEATURES 1.2 COMPLIANCE 1.3 PACKAGING 1.4 SIMILAR PRODUCTS AND ACCESSORIES

± 10g Tri-Axis Accelerometer Specifications

Transcription:

TECHNICAL BULLETIN TB-26 THE USE OF BU SERIES ACCELEROMETERS These notes are intended as a guide to the use of BU series accelerometers and not as a substitute for BU model specifications. OVERVIEW The BU is a small, single-axis low mass piezo-ceramic accelerometer with audio bandwidth. The most common usage is as a contact microphone picking up vocal vibrations through bone conduction. The inbuilt FET amplifier and high mechanical shock resistance also make this device, if mechanically protected, suitable for industrial applications. VBU-32500-000 Below 5 khz, the transverse sensitivity is at least 20 db below the main axis sensitivity. The outer casing is type 305 stainless steel, epoxy sealed and with solder pad terminations for attaching lead wires. It may be safely potted with epoxy if required (provided that the temperatures resulting from exothermic reactions are maintained below 100 C). BU is available in standard sensitivity or with mass added to the piezo element for increased sensitivity. MECHANICAL For bone-conducted voice pick-up: Resilient mounting is required to provide predictable contact force yet still allow vibration. Various techniques may be employed to achieve this goal. One method situates the BU on the end of a cantilevered arm that acts as a spring. The arm provides some decoupling from the primary structure (headset or helmet). Another is a trampoline structure where the BU resides in the center and the perimeter is secured to the headset or helmet such that the contact force is repeatable typically via a strap or cushion. A demonstrator assembly VBU-32500-000 is available as an example of a trampoline structure for evaluating performance. Contact Knowles field application engineering to request demonstrator and instructions. For general lightweight structures: Examples circuit boards, body panels, windows, medical, etc. Use BU without encapsulation to maintain low mass. It may be necessary to strengthen lead wire connections at terminals with epoxy. For use up to 5 khz, double-sided tape is adequate for attach. Above 5 khz, may use cyanoacrylate adhesive or epoxy. At room temperature, beeswax is sufficient. For machinery monitoring: BU should be encapsulated in bubble-free epoxy within a metal housing to accommodate fastener. It is highly recommended that the source-follower mode is used for high accelerations. The external circuit components should be encapsulated along with the BU within secondary metal housing which may be earthed. The BU element in this application must be electrically insulated from the secondary housing. 1

EFFECTS OF TEMPERATURE The BU will operate at 70 C with a nominal 1% increase in sensitivity. It may be stored at up to 120 C without permanent degradation (it will not operate at this temperature), but care should be taken to avoid rapid temperature changes because these may set up stresses in the piezo beam which will affect sensitivity. ELECTRICAL The ceramic piezo-electrical element is connected internally to a FET amplifier as shown below. Hi-meg 22 K ohm The case is connected to terminal 1 via resistance less than 1000 ohms. The transducer requires an external power supply which must be free of electrical noise. For the FET to operate, the voltage between terminals 1 and 3 must be greater than 1.1 V. It may be destroyed by voltages in excess of 20 V. The power input requirement is low, and may be supplied by a battery. The output impedance of BU depends on the mode of operation, but generally it is low enough to drive several feet of cable without special amplifiers. The three common methods of use are: 3-wire mode 2-wire mode Source-follower mode Simple connection of DC supply across terminals 1 and 3, then output taken from terminal 2. This connection provides high sensitivity. Uses only terminals 1 and 3, for situations where only two connecting wires to the transducer are available For measurements of high accelerations Some BU models are specified with 2-wire connection, some with 3-wire connection. Sensitivity and spread in sensitivity will change with different modes of operation. 2

3-WIRE MODE TYPICAL PERFORMANCE Supply voltage: 1.5 V DC (range 1.1-20 V). Current drain: 30 ua DC (range 20 50 ua) impedance: 13 k ohm (range 8 22 k ohm) Sensitivity: -37 db re 1 V/g (about 14 mvrms) Typical minimum g: about 0.003 g for 6 db S/N at 1 khz Typical maximum g: about 10 g at 1 khz / about 0.1 g at resonance Phase: acceleration in the direction of the arrow results in positive output 2-WIRE MODE TYPICAL PERFORMANCE R F < 2 k ohm, C F > 1 uf, R L < 20 k ohm (typically 4 k ohm) A change to R L will alter the sensitivity of the circuit. R F and C F decouple the power supply and are not necessary if battery powered, or supply ripple is very low. 3

FFECT OF ACOUSTIC RESISTANCE INCREASED WITH DISTANCE FROM MICROPHONE 3-WIRE MODE TYPICAL PERFORMANCE Supply voltage: 1.5 V DC (range 1.1-20 V) Current drain: 30 ua DC (range 20 50 ua) impedance: 5.2 k ohm (range 4.9 5.5 k ohm) Response: see Response section of this note Sensitivity: -45 db re 1 V/g (about 5.6 mvrms) Typical minimum g: about 0.003 g for 6 db S/N at 1 khz Typical maximum g: about 17 g at 1 khz / about 0.17 g at resonance For load resistor of 5.6 k ohm Phase: acceleration in the direction of the arrow results in positive output SOURCE-FOLLOWER MODE TYPICAL PERFORMANCE This method of connection overcomes the problem of electrically limiting the output due to the operating point of the FET amplifier. Two examples are: Dual Supply (Case earthed) Voltage Divider (case not earthed) Adjust R 2 until half of the DC supply volts appear at terminal 3. R 1 is typically 47 k ohm 4

FOR VOLTAGE DIVIDER HOOK-UP Supply voltage: 20 V DC (range 1.1-20 V) R 1 = 47 k ohm When 10 V at terminal 3, R 2 ~ 20 k ohm Response: see Response section of this note Sensitivity: -45 db re 1 V/g (about 5.6 mvrms) Typical noise from transducer ~7 uv, but take care with shielding as case is not earthed Typical maximum g: about 1780 g at 1 khz / about 17 g at resonance FREQUENCY RESPONSE Typical response shape shown below for 2-wire mode. Response conformity relative to 1 khz actual sensitivity: +/- 1.5 db at 300 Hz +2.0/-1.0 db at 3 khz 5 Knowles Corporation 1151 Maplewood Drive Itasca, Illinois 60143 Phone: 1 (630) 250-5100 Fax: 1 (630) 250-0575 sales@knowles.com Model/Reference Number: TECHNICAL BULLETIN TB-26 2017, Knowles Electronics, LLC