Control Cable. 1 Executive Standards. 3 Type and Designation. PVC insulated PVC sheathed control cable. PE insulated PE sheathed control cable

Similar documents
MarineLine YOZp 0,6/1 kv

Kerman & Kavian Cable Industries ( KCI )

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

MV water-proof and water tree retardant power cable

CUSTOM DESIGN COAXIAL CABLES BY SICAB

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

NETWORK CONNECTIVITY SYSTEMS

Tri-Rated Flexible PVC Equipment Wire

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Instrumentation Cable PLTC/ITC and TC Types

CIR (Crush & Impact Resistant) VFD Power Cable

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

14 AWG 2 AWG: 600 Volt

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

TRAXLINE CABLES FOR MOTION

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

SUBMERSIBLE PUMP CABLES

Servo Cable Selection

SAC-5P- 1,5-PUR/M12FS SH

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Medium Voltage Power Cables

EDS KV TRIPLEX CABLE RATING

List Price w.e.f. 02nd January, 2018

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Submersible Pump Cable

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Mineral-insulated resistance thermometers to EN

SAC-3P- 5,0-PUR/M12FR SH

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

CABLES AND WIRES

EDS LV WAVEFORM MAINS CABLE RATINGS

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

FieldLink MC at 20 x outer diameter Torsion

EXCELLENT ELECTRICAL PERFORMANCES

High Temperature Flexible Control Cable

VSD cables in. Working with. industrial & automation applications

Speedflex. Halogen free coaxial cables.

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Fault location on power cables. Fault location on power cables

COPPER + LWL RAW CABLES

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Instrumentation Cables


11-SDMS-03 REV. 02 SPECIFICATIONS FOR

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Armoured Instrumentation Cables to BS6883

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Armoured Power and Control Cables to BS7917

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Selection table for flat & ribbon cables

Armoured Power and Control Cables Fire Resistant

EDS KV SINGLE CORE XLPE CABLES

MULTIMEDIA CABLE H6091ZHB

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Marine Cables General Catalogue

The Quality Connection. Flex Flexible Control Cable

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

Armoured Power and Control Cables to BS6883

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

High Temperature Flexible Control Cable OLFLEX

DNVGL-CP-0400 Edition December 2015

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

SUPERIOR MARINE CABLE SOLUTIONS

Railway products. Edition 2014

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Testing Manual for Electrical Equipment

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

REPORT OF PERFORMANCE TIC

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

Cables for data transmission in industrial automation

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

The Quality Connection. ICON Product Guide

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

T E C H N I C A L D A T A for

RGCoaxials RG, low noise and sub-miniature coaxials

GEXOL WORLD CLASS OIL & GAS CABLES

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

Transcription:

Control Cable 1 Executive Standards GB9330-88 GB/T19666-005 It is manufactured according to GB9330-88 standards The low-smoking low-halogen low-smoking halogen-free flame-retardant cable, it complies with GB/T19666-005standards. Application (Uo/U)450/750V It is used for the signal transmission controlling and measuring system of the electric apparatus and the power distribute apparatus in the field of metallurgy,power and petrochemistry. Its rated voltage (Uo/U)is up to including 450/750V. 3 Type and Designation KVV KYY KYV KYJV KVVP KYYP KYVP KYJVP KVVP KYYP KYVP KYJVP KVVP3 KYYP3 KYVP3 KYJVP3 KVV PVC insulated PVC sheathed control cable PE insulated PE sheathed control cable PE insulated PVC sheathed control cable XLPE insulated PVC sheathed control cable PVC insulated PVC sheathed copper wire braided screen control cable PE insulated PE sheathed copper wire braided screen control cable PE insulated PVC sheathed copper wire braided screen control cable XLPE insulated PVC sheathed copper wire braided screen control cable PVC insulated PVC sheathed copper tape wrapped screen control cable PE insulated PE sheathed copper tape wrapped screen control cable PE insulated PVC sheathed copper tape wrapped screen control cable XLPE insulated PVC sheathed copper tape wrapped screen control cable PVC insulated PVCsheathed Al/plastic wrapped screen control cable PE insulated PE sheathed Al/plastic wrapped screen control cable PE insulated PVC sheathed Al/plastic wrapped screen control cable XLPE insulated PVC sheathed Al/plastic wrapped screen control cable PVC insulated PVC.sheathed double steel tape armoured control cable

ELECTRIC WIRES & CABLE KYV3 KYV KYJV KVVR KYYR KYVR KYJVR KVVRP KYYRP KYVRP KYJVRP Z-KVV Z-KYY Z-KYJV Z-KVVP Z-KYVP Z-KYJVP Z-KVVP Z-KYVP Z-KYJVP Z-KVVP3 Z-KYVP3 Z-KYJVP3 Z-KVV Z-KYV Z-KYJV PE insulated PE sheathed double steel tape armoured control cable PE insulated PVC sheathed double steel tape armoured control cable XLPE insulated PVC sheathed double steel tape armoured control cable PVC insulated PVC heathed flexible control cable PE insulated PE sheathed flexible control cable PE insulated PVC sheathed flexible control cable XLPE insulated PVC sheathed flexible control cable PVC insulated PVC sheathed copper wire braided screen flexible control cable PE insulated PE sheathed copper wire braided screen flexible control cable PE insulated PVC sheathed copper wire braided screen flexible control cable XLPE insulated PVC sheathed copper wire braided screen flexible control cable PVC insulated PVC sheathed control cable flame retardant PE insulated PE sheathed control cable flame retardant XLPE insulated PVC sheathed control cable flame retardant PVC insulated PVC sheathed copper wire braided screen control cable flame retardant PE insulated PVC sheathed copper wire braided screen control cable flame retardant XLPE insulated PVC sheathed copper wire braided screen control cable flame retardant PVC insulated PVC sheathed, copper tape wrapped screen control cable flame retardant PE insulated PVC sheathed copper tape wrapped screen control cable flame retardant XLPE insulated PVC sheathed copper tape wrapped screen control cable flame retardant PVC insulated PVC.sheathed Al/plastic wrapped screen control cable flame retardant PE insulated PVC.sheathed Al/plastic wrapped screen control cable flame retardant XLPE insulated PVC sheathed Al/plastic wrapped screen control cable flame retardant PVC insulated PVC sheathed double steel tape armoured control cable flame retardant PE insulated PVC sheathed double steel tape armoured control cable flame retardant XLPE insulated PVC sheathed double steel tape armoured control cable flame retardant

Z-KVVR Z-KYVR Z-KYJVR Z-KVVRP Z-KYVRP Z-KYJVRP DDZ-KVV DDZ-KYV DDZ-KYJV DDZ-KVVP DDZ-KYVP DDZ-KYJVP DDZ-KVVP DDZ-KYVP DDZ-KYJVP DDZ-KVVP3 DDZ-KYVP3 DDZ-KYJVP3 DDZ-KVVP DDZ-KYVP DDZ-KYJVP DDZ-KVVR DDZ-KYVR DDZ-KYJVR DDZ-KVVRP DDZ-KYVRP PVC insulated PVC sheathed flexible control cable flame retardant PE insulated PVC sheathed flexible control cable flame retardant XLPE insulated PVC sheathed flexible control cable flame retardant PVC insulated PVC sheathed copper wire braided screen flexible control cable flame retardant PE insulated PVC sheathed copper wire braided screen flexible control cable flame retardant XLPE insulated PVC sheathed copper wire braided screen flexible control cable flame retardant PVC insulated PVC sheathed control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed control cable low-smoking low-halogen flame retardant XLPE insulated PVC sheathed control cable low-smoking low-halogen flame retardant PVC insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant XLPE insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant PVC insulated.pvc.sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant XLPE insulated PVC sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant PVC insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant PE insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant XLPE insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant PVC insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant XLPE insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant PVC insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant XLPE insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant PVC insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant PE insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant

ELECTRIC WIRES & CABLE DDZ-KYJVRP WDZ-KYJY WDZ-KYY WDZ-KYJYP WDZ-KYYP WDZ-KYJYP WDZ-KYYP WDZ-KYJYP3 WDZ-KYYP3 WDZ-KYJY3 WDZ-KYY3 WDZ-KYJYR WDZ-KYYR WDZ-KYJYRP WDZ-KYYRP XLPE insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant XLPE insulated PO sheathed control cable PO insulated PO sheathed control cable XLPE insulated PO sheathed copper wire braided common shield control cable PO insulated PO sheathed copper wire braided common shield control cable XLPE insulated PO sheathed copper tape wrapped common shield control cable PO insulated PO sheathed copper tape wrapped common shield control cable XLPE insulated PO sheathed Al/plastic wrapped common shield control cable PO insulated PO sheathed Al/plastic wrapped common shield control cable XLPE insulated PO sheathed double steel tape armoured control cable PO insulated PO sheathed double steel tape armoured control cable low-smoking halogenfree flame retardant XLPE insulated, PO sheathed flexible control cable, PO insulated, PO sheathed flexible control cable, XLPE insulated, PO sheathed, copper wire braided common shield flexible control cable, PO insulated, PO sheathed, copper wire braided common shield flexible control cable,

4 Explanation of the code in the type Items Insulation sheathed class of conductor shield Armor Over sheathed Heat-resistance grade Flame-retardant characteristics Code K Y V YJ Y Y V R (Omitted) P P P3 (Omitted) 3 / 90 (Omitted) Z DDZ WDZ control cable PE PVC XLPE PO PE/PO PVC Muti-strands flexible conductor No shield copper wire braided copper tape wrapped Al/plastic wrapped No armour double steel tape armour PVC PE,70 70 ; 90 70 for PE, 70 PVC Or HFPO insulation cable, 90 for XLPE insulation cable 90 The max. long-term operating temperature of conductor is 90 No requirement Bundle Flame-retardant low-smoking&low-halogen flame retardant low-smoking&halogen-free flame retardant 5 Explanation Nominal sectional area(mm ) Core No. Heat-resistance grade Over sheath Armor shield kind of conductor sheathed Insulation senes code Flame-retardant code : ( ) 10mm,A,,B- Remarks :( ) means the class conductor when its nominal area is less than 10mm,A means solid conductor, Can be omitted,b means it is stranded conductor.

ELECTRIC WIRES & CABLE 6 Indication Examples,, (B), : The indication of plastic insulated control cable consists of type,number of cores,nominal sectional area of conductor,when the same type product is made of different class of conductor, the more flexible one is indicated with (B) following the specitication.for exampies : 6.1, 16,,.5mm, : :KVV 16.5 :KVV 16.5(B) PVC insulated PVC sheathed control cable, 16 cores, nominal sectional area is.5mm is indicated with: The harder one: KVV 16.5 The more flexible one: KVV 16.5(B) 6., 1, 4mm, : Z-KYJV 1 4 XLPE insulated PVC sheathed double steel tape armoured control cable, flame retardant, 1cores, nominal sectional area is 4mm, is indicated with: Z-KYJV 1 4 7 Using feature &Main Technical Performances 7.1 (U O /U):450/750V Rated voitage(u O /U): 450/750V; 7. : : 70 : 90 The Max. long-term operating temperature of conductor: PEinsulated cable:70 XLPE insulated cable: 90 :70 90 ( ); PVC insulated cable: 70 90 (according to the grade of heat proof after the type) : 70,90 ( ); PO insulated cable: 70 90 (according to the grade of heat proof after the type) 7.3 :- 0 : :0 ( ) The Min.laying temperature is: - 0 for PE sheathed cable; 0 for PVC or HFPO sheathed cable. (It should be preheated if it is below the Min.laying temperature). 7.4 : 1 ; 6 The permitted bending radius: No less than 1 times of the overall diameter of the cable for which has armor or copper tape wrapped shield.no less than 6 times of the overall diameter of the cable for the others. 7.5 Flame characteristics GB/T 19666-005 The cable flame-retardant low-smoking low halogen flame retardant low-smoking halogen-free flame retardant should be adopted with GB/T19666-005.

Nominal section area mm 0.5 0.75 1.0 1.5.5 4 6 10 Nominal section area mm 0.5 0.75 1.0 1.5.5 4 6 10 7.6 3; 4 The D.C resistance of conductor is show in table 3 and the insulation resistance is show in table 4. 3 table 3 0 D.C. resistance of conductor at 0 Ω/km Untinned Tinned Kind A B Kind B Flexible Kind A 36.0 36.0 39.0 36.7 4.5 4.5 6.0 4.8 18.1 18.1 19.5 18. 1.1 1.1 13.3 1. 7.41 7.41 7.98 7.56 4.61 4.61 4.70 3.08 3.08 3.11 1.83 70 90 Insulation resistance at 70 or 90 MΩ km B Kind B 36.7 4.8 18. 1. 7.56 4.70 3.11 1.84 Flexible 40.1 6.7 0.0 13.7 8.1 4 table 4 PEor XLPE insulated PVCorHFPO insulated Kind A B Kind B Flexible Kind A B Kind B Flexible 0.1400 0.1300 0.1300 0.014 0.014 0.013 0.100 0.1100 0.1100 0.01 0.014 0.011 0.1100 0.1000 0.1000 0.011 0.013 0.010 0.1100 0.1000 0.1000 0.011 0.010 0.010 0.1000 0.0900 0.0900 0.010 0.009 0.009 0.0850 0.0700 0.0085 0.0077 0.0700 0.0650 0.0070 0.0065 0.0650 0.0065 8 Manufacturing scope Type mm Conductor nominal cross-section area mm 0.5 0.75 1.0 1.5.5 4 6 10 Core No. KVV KYY KYJV KYV Z-KVV Z-KYV Z-KYJV DDZ-KVV DDZ-KYV DDZ-KYJV WDZ-KYY WDZ-KYJY KYYP KVVP KYJVP KYVP Z-KVVP Z-KYJVP Z-KYVP DDZ-KVVP Z-KYVP Z-KYJVP WDZ-KYYP WDZ-KYJYP ~61 ~14 ~10 KVVP KVVP3 KYYP KYYP3 KYVP KYVP3 KYJVP KYJVP3 Z-KVVP Z-KVVP3 Z-KYVP Z-KYVP3 Z-KYJVP Z-KYJVP3 DDZ-KVVP DDZ-KVVP3 DDZ-KYVP DDZ-KYVP3 DDZ-KYJVP DDZ-KYJVP3 WDZ-KYYP3 WDZ-KYYP WDZ-KYJYP WDZ-KYJYP3 4~61 4~14 4~10 KVV KVV3 KYV3 KYJV KYJV3Z-KVV Z-KVV3Z-KYV Z-KYJV3 WDZ-KYY3 WDZ-KYJY3 4~61 4~14 4~10 KVVR KYYR KYJVR KYVR Z-KVVR Z-KYJVR WDZ-KYVR 4~ 61 WDZ-KYYR WDZ-KYJYR KVVRP KYYRP KYVRP KYJVRP Z-KVVRP Z-KYVRP Z-KYJVRP Z-KVVRP DDZ-KYVRP DDZ-KYJVRP WDZ-KYYRP WDZ-KYJYRP 4~61 4~48