A rated contacts PCB mount - bifurcated terminals. Copper side view

Similar documents
Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

2 or 4 pole changeover contact Plug-in/Faston 187

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

62.22 Copper side view

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

62 Series - Power relays 16 A. Features / /

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

48 Series - Relay interface modules A. Features

38 Series - Relay interface modules A. Features /

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

The power in relays and timers since Catalogue

Relay interface modules A

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

38 Series - Relay interface modules A

38 Series - Relay interface modules A

40 Series - Miniature P.C.B. Relays A

38 Series - Relay Interface Modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

SPST-NO SPDT DPST-NO DPDT

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Modular step relays 16 A

Features. Designation (provided with) style. Contact. Insulation. system. gap. 110A-1AH-F-C 110BA-1AH-F-C 110A-1AH1-F-C 110BA-1AH1-F-C High power type

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

83 Series - Modular timers 16 A. Features

Classification Enclosure rating Contact form Contact material

83 SERIES. 83 Series - Modular timers A. Features

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Multi-voltage Multi-function. Wiring diagram (without control signal)

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

1a/1c/2a/2c/5A/10A power relays for power supply

Compact Relay Family with Forcibly Guided Contacts

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

SPST-NO SPDT DPST-NO DPDT

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

Miniature Power Relay MSR

Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954

Compliant with European standards 1a/1c 6A Slim power relays

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).


EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

16A POWER RELAY FOR MICRO WAVE OVEN

1a 16A power relay for micro wave oven

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

87 Series - Modular timers 5-8 A. Features

COMPACT PC BOARD POWER RELAY

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Song Chuan / Relay Catalog 507

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

1a/1c/2a/2c/5A/10A power relays for power supply

Modular timers A

No-wear isolation of potentials in terminal block design

Electronic timer CT-SDD.22

Electronic timer CT-TGD.22

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

POWER RELAY. FTR-K3-WS Series. 1 POLE - High Capacity 25A Type FTR-K1 SERIES FEATURES

Features. UL Insulation. Sealed type washable 1A (SPNO) H H-1A-C 845H-1A-V 845H-1A-S. system approval Flux tight Sealed type

Output of three-phase motors at 50 Hz and 400 V

Electronic timer CT-SDS.22

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

02/11/2015

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

COMPACT PC BOARD POWER RELAY

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

08/07/2015

PCB relay for DC voltage, polarized, monostable or bistable

02/11/2015

7E Series - Energy meter. Features PTB 1

08/07/2015

Safety Monitoring Relays

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

1a/1c 5A/10A small power relays

27/04/2015

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

Transcription:

66 Power relays 30 66 2 Pole Changeover (DPDT) 30 Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil and contacts according to EN 60335-1; 8 mm creepage and clearance distances C coils & DC coils Cadmium Free option available TEX compliant (EX nc) option available 66.22 66.82 30 rated contacts PCB mount - bifurcated terminals 30 rated contacts Flange mount Faston 250 connections For outline drawing see page 7 For UL ratings see: General technical information page V Copper side view Contact specification Contact configuration 2 CO (DPDT) 2 CO (DPDT) Rated current/maximum peak current 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC) Rated voltage/ Maximum switching voltage V C 250/440 250/440 Rated load C1 V 7500 (NO) - 2500 (NC) 7500 (NO) - 2500 (NC) Rated load C15 (230 V C) V 1200 (NO) 1200 (NO) Single phase motor rating (230 V C) kw 1.5 (NO) 1.5 (NO) Breaking capacity DC1: 30/110/220 V 25/0.7/0.3 (NO) 25/0.7/0.3 (NO) Minimum switching load mw (V/m) 1000 (10/10) 1000 (10/10) Standard contact material gcdo gcdo Coil specification Nominal voltage (U N ) V C (50/60 Hz) 6-12 - 24-110/115-120/125-230 - 240 V DC 6-12 - 24-110 - 125 Rated power C/DC V (50 Hz)/W 3.6/1.7 3.6/1.7 Operating range C (0.8 1.1)U N (0.8 1.1)U N DC (0.8 1.1)U N (0.8 1.1)U N Holding voltage C/DC 0.8 U N / 0.5 U N 0.8 U N / 0.5 U N Must drop-out voltage C/DC 0.2 U N / 0.1 U N 0.2 U N / 0.1 U N Technical data Mechanical life C/DC cycles 10 10 6 10 10 6 Electrical life at rated load C1 cycles 100 10 3 100 10 3 Operate/release time ms 8/15 8/15 Insulation between coil and contacts (1.2/50 µs) kv 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V C 1500 1500 mbient temperature range C 40 +70 40 +70 Environmental protection RT II RT II pprovals (according to type) 1

66 66 Power relays 30 2 Pole NO (DPST-NO) 30 Power relay 66.22-x300 PCB mount 66.82-x300 Faston 250 connections - Flange mount Reinforced insulation between coil and contacts according to EN 60335-1; 8 mm creepage and clearance distances C coils & DC coils Cadmium Free option available TEX compliant (EX nc) option available 66.22-x30x 30 rated contacts PCB mount - bifurcated terminals 66.82-x30x 30 rated contacts Flange mount Faston 250 connections For outline drawing see page 7 For UL ratings see: General technical information page V Copper side view Contact specification Contact configuration 2 NO (DPST-NO) 2 NO (DPST-NO) Rated current/maximum peak current 30/50 30/50 Rated voltage/ Maximum switching voltage V C 250/440 250/440 Rated load C1 V 7500 7500 Rated load C15 (230 V C) V 1200 1200 Single phase motor rating (230 V C) kw 1.5 1.5 Breaking capacity DC1: 30/110/220 V 25/0.7/0.3 25/0.7/0.3 Minimum switching load mw (V/m) 1000 (10/10) 1000 (10/10) Standard contact material gcdo gcdo Coil specification Nominal voltage (U N ) V C (50/60 Hz) 6-12 - 24-110/115-120/125-230 - 240 V DC 6-12 - 24-110 -125 Rated power C/DC V (50 Hz)/W 3.6/1.7 3.6/1.7 Operating range C (0.8 1.1)U N (0.8 1.1)U N DC (0.8 1.1)U N (0.8 1.1)U N Holding voltage C/DC 0.8 U N / 0.5 U N 0.8 U N / 0.5 U N Must drop-out voltage C/DC 0.2 U N / 0.1 U N 0.2 U N / 0.1 U N Technical data Mechanical life C/DC cycles 10 10 6 10 10 6 Electrical life at rated load C1 cycles 100 10 3 100 10 3 Operate/release time ms 8/10 8/10 Insulation between coil and contacts (1.2/50 µs) kv 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V C 1500 1500 mbient temperature range C 40 +70 40 +70 Environmental protection RT II RT II pprovals (according to type) 2

66 Power relays 30 66 2 Pole NO (DPST-NO), 1.5 mm contact gap 30 Power relay 66.22-x600 PCB mount 66.22-x600S PCB mount - 5 mm gap between PCB and relay base 66.82-x600 Faston 250 connections - Flange mount 1.5 mm contact gap (according to VDE 0126-1-1 for solar inverter applications) Reinforced insulation between coil and contacts according to EN 60335-1; 8 mm creepage and clearance distances Wash tight version (RT III) available DC coils Cadmium Free option available TEX compliant (EX nc) option available 66.22-x60x 66.22-x60xS 66.82-x60x PCB mount - bifurcated terminals PCB mount - bifurcated terminals 5 mm gap between PCB and relay base Flange mount Faston 250 connections For outline drawing see page 7 For UL ratings see: General technical information page V Copper side view Copper side view Contact specification Contact configuration 2 NO (DPST-NO) 2 NO (DPST-NO) 2 NO (DPST-NO) Rated current/maximum peak current 30/50 30/50 30/50 Rated voltage/ Maximum switching voltage V C 250/440 250/440 250/440 Rated load C1 V 7500 7500 7500 Rated load C15 (230 V C) V 1200 1200 1200 Single phase motor rating (230 V C) kw 1.5 1.5 1.5 Breaking capacity DC1: 30/110/220 V 25/1.2/0.5 25/1.2/0.5 25/1.2/0.5 Minimum switching load mw (V/m) 1000 (10/10) 1000 (10/10) 1000 (10/10) Standard contact material gcdo gcdo gcdo Coil specification Nominal voltage (U N ) V C (50/60 Hz) V DC 6-12 - 24-110 -125 Rated power C/DC V (50 Hz)/W /1.7 /1.7 /1.7 Operating range C DC (0.8 1.1)U N (0.7 1.1)U N (0.8 1.1)U N Holding voltage C/DC /0.5 U N /0.5 U N /0.5 U N Must drop-out voltage C/DC /0.1 U N /0.1 U N /0.1 U N Technical data Mechanical life cycles 10 10 6 10 10 6 10 10 6 Electrical life at rated load C1 cycles 100 10 3 100 10 3 100 10 3 Operate/release time ms 15/4 15/4 15/4 Insulation between coil and contacts (1.2/50 µs) kv 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V C 2500 2500 2500 mbient temperature range C 40 +70 40 +70 40 +70 Environmental protection RT II RT II RT II pprovals (according to type) 3

66 66 Power relays 30 Ordering information Example: 66 series relay, Faston 250 (6.3x0.8 mm) with top flange mount, 2 CO (DPDT) 30 contacts, 24 V DC coil. B C D 6 6. 8 2. 9. 0 2 4. 0 0 0 0 Series Type 2 = PCB 8 = Faston 250 (6.3 x 0.8 mm) with top flange mount No. of poles 2 = 2 pole 30 (versions 0, 1) 2 = 2 pole 25 (version 3) Coil version 8 = C (50/60 Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version B C D 66.22 C-DC 0-1 0-3 0 0-1 DC 0-1 6 0 0-1 66.22.S DC 0-1 6 0 0-1 - 3 66.82 C-DC 0-1 0-3 0 0-1 - 3 DC 0-1 6 0 0-1 - 3 : Contact material 0 = Standard gcdo 1 = gni B: Contact circuit 0 = CO (npdt) 3 = NO (npst) 6 = NO (npst), 1.5 mm contact gap S = PCB version with 5 mm gap between PCB and relay base (only 66.22) D: Special versions 0 = Standard 1 = Wash tight (RT III) 3 = TEX compliant (Ex nc) C: Options 0 = None Technical data Insulation according to EN 61810-1 Nominal voltage of supply system V C 230/400 Rated insulation voltage V C 400 Pollution degree 3 Insulation between coil and contact set Type of insulation Reinforced (8 mm) Overvoltage category III Rated impulse voltage kv (1.2/50 µs) 6 Dielectric strength V C 4000 Insulation between adjacent contacts Type of insulation Basic Overvoltage category III Rated impulse voltage kv (1.2/50 µs) 4 Dielectric strength V C 2500 Insulation between open contacts 2 CO 2 NO, 1.5 mm (x60x version) Type of disconnection Micro-disconnection Full-disconnection* Overvoltage category II Rated impulse voltage kv (1.2/50 µs) 2.5 Dielectric strength V C/kV (1.2/50 µs) 1500/2 2500/3 Conducted disturbance immunity Burst (5 50)ns, 5 khz, on 1-2 EN 61000-4-4 level 4 (4 kv) Surge (1.2/50 µs) on 1-2 (differential mode) EN 61000-4-5 level 4 (4 kv) Other data Bounce time: NO/NC ms 7/10 Vibration resistance (10 150)Hz: NO/NC g 20/19 Shock resistance g 20 Power lost to the environment without contact current W 2.3 with rated current W 5 Recommended distance between relays mounted on PCB mm 10 * Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. 4

66 Power relays 30 66 Contact specification F 66 - Electrical life (C) v contact current 250 V (normally open contact) F 66 - Electrical life (C) v contact current 440 V (normally open contact) Cycles Resistive load - 250 V C cosϕ = 1 Inductive load - 250 V C cosϕ = 0.4 Cycles Resistive load - 440 V C cosϕ = 1 Inductive load - 440 V C cosϕ = 0.4 H 66 - Maximum DC breaking capacity H 66 - Maximum DC breaking capacity, x60x versions (> 1.5 mm contact gap) DC breaking current () DC breaking current () DC voltage (V) DC voltage (V) When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100 10 3 can be expected. In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. Coil specifications DC coil data C coil data Nominal voltage Coil code Operating range Resistance Rated coil Consumption U N U min U max R I at U N V V V Ω m 6 9.006 4.8 6.6 21 283 12 9.012 9.6 13.2 85 141 24 9.024 19.2 26.4 340 70.5 110 9.110 88 121 7000 15.7 125 9.125 100 138 9200 13.6 R 66 - DC coil operating range v ambient temperature Nominal voltage Coil code Operating range Resistance Rated coil Consumption U N U min U max R I at U N (50 Hz) V V V Ω m 6 8.006 4.8 6.6 3 600 12 8.012 9.6 13.2 11 300 24 8.024 19.2 26.4 50 150 110/115 8.110 88 126 930 32.6 120/125 8.120 96 137 1050 30 230 8.230 184 253 4000 15.7 240 8.240 192 264 5500 15 R 66 - C coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 3 - Min. pick-up voltage with coil at ambient temperature (66.22-x60xS) 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 5

66 66 Power relays 30 Features compliant variant TEX, II 3G Ex nc IIC Gc MRKING Specific marking of explosion protection II Component for surface plant (different from mines) 3 Category 3: normal level of protection G Explosive atmosphere due to presence of combustible gas vapour or mist Ex nc Sealed device (type of protection for category 3G) IIC Gas group Gc Equipment Protection Level 40 C Ta +70 C mbient temperature EUT 14 TEX 0150 U EUT: laboratory which issues the CE type certificate 14: year of issue of certificate 0150: number of CE type certificate U: TEX component GS Electrical characteristics Characteristics of terminals Rated current/maximum peak current 25/50 (NO) - 10/20 (NC) Rated voltage/maximum switching voltage V C 250/400 Rated load C1 V 6250 (NO) - 2500 (NC) Rated load C15 V 1200 (NO) Capacity for single phase motor (230 V C) kw 1.5 (NO) Breaking capacity DC1: 30/110/220 V 25/0.7/0.3 (NO) Characteristics of coil Rated voltage (U N ) V C (50/60 Hz) 6-12 - 24-110/115-120/125-230 - 240 V DC 6-12 - 24-110 - 125 Rated Power C/DC V (50 Hz)/W 3.6/1.7 Operating range C/DC (0.8 1.1)U N General characteristics mbient temperature C 40 +70 Special condition for safe use The component must be placed inside an enclosure that meets the general requirements for enclosures as per clause 6.3 of EN 60079-15. The connections must be made in compliance with the requirements of clause 7.2.4 or 7.2.5 of EN 60079-15. Wiring The cross-section of conductors connected to the terminals, must be at least 4 mm 2 for the Type 66.82. Layout pcb The minimum cross-section of the tracks of the printed circuit board must be 0.58 mm 2, while the width must be at least 4 mm for Types 66.22 and 66.22.S. 6

66 Power relays 30 66 Outline drawings Type 66.22 Type 66.82 Type 66.22-0300 Type 66.82-0300 Type 66.22-0600 Type 66.82-0600 Type 66.22-0600S ccessories Top 35 mm rail (EN 60715) mount for types 66.82.xxxx.0x00 066.07 066.07 066.07 with relay 066.07 066.07 with relay 7