Design and Development of a Two Channel Telemedicine System for Rural Healthcare

Similar documents
WIRELESS ELECTRONIC STETHOSCOPE USING ZIGBEE

Sensor, Signal and Information Processing (SenSIP) Center and NSF Industry Consortium (I/UCRC)

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

A Body Area Network through Wireless Technology

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

Noise Cancellation on ECG and Heart Rate Signals Using the Undecimated Wavelet Transform

STM32 microcontroller core ECG acquisition Conditioning System. LIU Jia-ming, LI Zhi

CHAPTER 7 HARDWARE IMPLEMENTATION

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

Patient Monitoring System Using LabVIEW

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

DATA ACQUISITION AND DATA PROCESSING SOFTWARE FOR MAGNETIC MEASUREMENTS FOR NICA MAGNETS

Real-time Data Collections and Processing in Open-loop and Closed-loop Systems

Implementation of wireless ECG measurement system in ubiquitous health-care environment

Robust Wrist-Type Multiple Photo-Interrupter Pulse Sensor

Noise Cancellation on ECG and Heart Rate Signals Using the Undecimated Wavelet Transform

A Design Of Simple And Low Cost Heart Rate Monitor

Keywords: Data Acquisition, ECG, LabVIEW, Virtual instrumentation

LabVIEW Based Biomedical Signal Acquisition and Processing

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

Chest Worn Pulse Oximeter Integrating NI-USRP with GPS Disciplined Clock Transceiver

BIOMEDICAL DIGITAL SIGNAL PROCESSING

6.111 Final Project Proposal HeartAware

DESIGNING A VIRTUAL MACHINE FOR IDENTIFICATION OF CARDIAC ARRHYTHMIAS USING LAB VIEW

A DESIGN OF PORTABLE HEART-RATE MONITORING SYSTEM

ARM BASED WAVELET TRANSFORM IMPLEMENTATION FOR EMBEDDED SYSTEM APPLİCATİONS

Removal of Power-Line Interference from Biomedical Signal using Notch Filter

Keywords Internet, LabVIEW, Smart Classroom-cum-Laboratory, Teaching and Learning process of communication.

Development of 4/16-Channel Data Acquisition System Using Lab VIEW

Wireless Heartbeat Monitoring System Using Android

Removal of Motion Noise from Surface-electromyography Signal Using Wavelet Adaptive Filter Wang Fei1, a, Qiao Xiao-yan2, b

An IoT Based Real-Time Environmental Monitoring System Using Arduino and Cloud Service

Simulation of Analog Modulation and Demodulation Techniques in Virtual Instrumentation and Remote Lab

Faculty of Information Engineering & Technology. The Communications Department. Course: Advanced Communication Lab [COMM 1005] Lab 6.

ENGR 499: Wireless ECG

REVIEW ON-IOT BASED SMART HEALTHCARE SYSTEM

Portable, Low Cost, Low Power Cardiac Interpreter

Analog Circuits and Systems

JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY

Detection of Abnormalities in Fetal by non invasive Fetal Heart Rate Monitoring System

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

City, University of London Institutional Repository

6.101 Introductory Analog Electronics Laboratory

COMPARISON OF VARIOUS FILTERING TECHNIQUES USED FOR REMOVING HIGH FREQUENCY NOISE IN ECG SIGNAL

NEW! AOIP FD5 Advanced Digital Data Logger

Available online at ScienceDirect. Procedia Technology 14 (2014 )

ECG Data Compression

Wireless Cardiac Rhythm Monitoring System

Measurement & Control of energy systems. Teppo Myllys National Instruments

IoT based Heart Attack Detection, Heart Rate and Temperature Monitor

Data acquisition and instrumentation. Data acquisition

Optimized BPSK and QAM Techniques for OFDM Systems

Massachusetts Institute of Technology MIT

Embedded Prototype System for Monitoring Heart Rate

Comparative Analysis of WDR-ROI and ASWDR-ROI Image Compression Algorithm for a Grayscale Image

ARRHYTHMIAS are a form of cardiac disease involving

FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

Real Time Multichannel EMG Acquisition System

Available online at ScienceDirect. Procedia Computer Science 105 (2017 )

Development of a Low Cost ECG Data Acquisition Module

Copyright 2007 Year IEEE. Reprinted from ISCAS 2007 International Symposium on Circuits and Systems, May This material is posted here

Real Time Indoor Tracking System using Smartphones and Wi-Fi Technology

THE PENNSYLVANIA STATE UNIVERSITY. Lab 2: Designing Optical Theremin Instrument. EE 300W Section 001. Nathaniel Houtz, Ji Eun Shin, Peter Wu 2/22/2013

Level 6 Graduate Diploma in Engineering Electronics and telecommunications

PROCESSING ECG SIGNAL WITH KAISER WINDOW- BASED FIR DIGITAL FILTERS

Introduction. Research Article. Md Salah Uddin Farid, Shekh Md Mahmudul Islam*

WRIST BAND PULSE OXIMETER

IMPLEMENTATION AND DESIGN OF TEMPERATURE CONTROLLER UTILIZING PC BASED DATA ACQUISITION SYSTEM

Design of PID Control System Assisted using LabVIEW in Biomedical Application

An IoT based Remote HRV Monitoring System for Hypertensive Patients

HTTP Compression for 1-D signal based on Multiresolution Analysis and Run length Encoding

REMOTE HEALTH MONITORING SYSTEM USING PIC MICROCONTROLLER

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Interfacing Industrial Analog Sensors to the Internet of Things Darold Wobschall Esensors Inc.

Remote Monitoring of Heart and Respiration Rate Using a Wireless Microwave Sensor

Filtration Of Artifacts In ECG Signal Using Rectangular Window-Based Digital Filters

A Dynamically Reconfigurable ECG Analog Front-End with a 2.5 Data-Dependent Power Reduction

EKG De-noising using 2-D Wavelet Techniques

Question 1 Draw a block diagram to illustrate how the data was acquired. Be sure to include important parameter values

ELG3336 Design of Mechatronics System

JDSP in Education. NSF Phase 3 J-DSP Workshop, UCy Presenter: Mahesh K. Banavar

The Study of Methodologies for Identifying the Drowsiness in Smart Traffic System: A Survey Mariya 1 Mrs. Sumana K R 2

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Virtual Instrument for FPGA based Spectrum Analyzer

Bird Model 7022 Statistical Power Sensor Applications and Benefits

RF(433Mhz) BASED PROJECTS

The report presents the functionality of our project, the problems we encountered, the incurred costs and timeline for the project development.

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

FPGA implementation of DWT for Audio Watermarking Application

Programmable Wireless Networking Overview

Adaptive Detection and Classification of Life Threatening Arrhythmias in ECG Signals Using Neuro SVM Agnesa.A 1 and Shally.S.P 2

III Lead ECG Pulse Measurement Sensor

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

An EOG based Human Computer Interface System for Online Control. Carlos A. Vinhais, Fábio A. Santos, Joaquim F. Oliveira

DESIGN OF LOW POWER SAR ADC FOR ECG USING 45nm CMOS TECHNOLOGY

2.4GHZ CLASS AB POWER AMPLIFIER FOR HEALTHCARE APPLICATION

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

Transcription:

Engineering, 2013, 5, 579-583 http://dx.doi.org/10.4236/eng.2013.510b119 Published Online October 2013 (http://www.scirp.org/journal/eng) Design and Development of a Two Channel Telemedicine System for Rural Healthcare Mitrra Potheri Ramesh, Shruthi Balasubramanian, Varsha Vijayan *, Geethanjali Balasubramanian, Mahesh Veezhinathan Department of Bio-Medical Engineering, SSN College of Engineering, Kalavakkam, Chennai, India Email: * varsha.bme@gmail.com Received 2013 ABSTRACT In this work, an attempt has been made to design an Electro Cardio Gram (ECG) and Photo Plethysmo Gram (PPG) based telemedicine system for rural health care. In India as per the survey conducted by Indian Medical Society in the year 2009, it has been revealed that only 2% of the qualified doctors practice in rural areas. Also, according to the statistics taken by the World Health Organization, every year an estimated 17 million people die of various cardio vascular diseases. This paper introduces the transmission of ECG and PULSE from remote areas to the specialists office. The ECG and PPG signals are acquired, digitized and processed using LabVIEW for detection of heart and pulse rate. These data are transmitted using two methods namely Web publishing tool and Shared Variables. The results confirm the transfer of data with less than millisecond delay. Keywords: Telemedicine; ECG; LabVIEW; Web Publishing Tool; Shared Variables 1. Introduction Telemedicine is the process of communication of healthcare related information from one place to another in the form of interactive audio visual media. The rapid advancements in information and communication technology can be used to bridge the rural urban divide. This technique proves to be very important during life threatening situations and in places with lack of availability of specialists. Various methods of transmission of physiological data have been carried out previously. One such system uses Time Division Multiplexing (TDM) to transmit data via Bluetooth [1]. Another system uses a wearable vital sign monitor that consists of a transmitter. It transmits the information via a Home Gateway using a proprietary protocol nrf24xx, to the central station [2]. The transmission has also been achieved using RF transmitter and receiver with slotted ALOHA for access by multiple users [3]. This paper deals with the acquisition, processing and transmission of ECG and PPG signals from the remote computer to the client using Web publishing tool and Shared Variables. Hence, the diagnosis of a rural patient can be facilitated by a city doctor with access to a computer installed with LabVIEW and Internet. Further, it eliminates the need for the conventional transmitter-receiver with limited range. The other applications include * Corresponding author. transmission of vital details from ICU to the doctor s cabin and future developments can be done in transmitting the parameters to specialist who is based anywhere in the world. 2. Materials and Methods 2.1. Experimental Setup The ECG-based telemedicine system [4] mainly consists of the following five parts 1) Data acquisition system; 2) Amplification of the acquired signals using hardware modules; 3) Physiological signal reception in computer; 4) Signal processing and display; 5) Web publishing tool and Shared Variables for viewing the signals on a browser at a remote computer. The signals can be viewed and controlled from both the remote computer (server) and the clients side. 2.2. Data Acquisition System The ECG data is acquired from surface electrode using Standard Recording Protocol. The acquired ECG is then amplified using a hardware module with IC AD620. The pulse signal is acquired using a Pulse Oximeter and amplified using IC LM324. The amplified signals are then given as input to the three part NI-ELVIS system, the NI-ELVIS workstation (prototype board) that interfaces with the NI-DAQ (data acquisition) device and Lab- VIEW software. NI ELVIS has a sampling rate of 1.25

580 P. R. MITRRA ET AL. MegaSamples/second for single channel and an aggregate of 1.00 MegaSamples/second [5] for multichannel. The outputs of ECG amplifier and Pulse amplifier channel are AI-0, AI-1 of NI-ELVIS respectively. NI-DAQ captures the ECG and pulse signals for analysis in Lab- VIEW. 2.3. Signal Analysis Instrumentation amplifier AD620 is used for amplifying the acquired ECG. The choice of AD620 for this analysis is due to its low noise, low input bias current and low power and the use of a single external resistor for Gain variation from 1 to 10,000 [6]. The gain-setting resistor (R G ) determines the gain, given by Equation (1). G = 1 + {(49.4) kω/r G } (1) The CMRR for gain = 10 is about 100 db. IC LM324 is used for pulse amplification. The analog signals are then processed in LabVIEW. 2.3.1. ECG Analysis ECG acquired from healthy subjects using surface electrodes is preprocessed prior to detailed analysis. Initially, raw ECG is preprocessed for noise and baseline drift removal. This is done using Wavelet Denoising tool. Daubechies 6 (db6) [7] wavelet is suitable because its shape resembles that of ECG. For better balance between smoothness and accuracy when compared to Discrete Wavelet Transform (DWT), Undecimated Wavelet Transform (UWT) [8] of level 8 is applied. The choice of this level is because the noise removal efficiency is proportional to the increase in levels. In addition, a sampling rate of 1000 Hz is used; level 8 accounts for 7 Hz which falls within QRS complex range. Pan Tompkins [9] algorithm is then implemented for Heart Rate estimation. Finite Impulse Response band pass filter of order 30, with cut off frequency of 5-11 Hz is used for allowing QRS complex. The filtered ECG is then differentiated and squared to enhance the high frequency R-waves present. The peaks are then smoothened using movingwindow integrator which is essential to avoid multiplecounting. Tone measurements block is used to compute the frequency and eventually, the time interval and heart rate are calculated and displayed. Two abnormal conditions prominent in ECG viz. Bradycardia (below 30 beats) and Tachycardia (above 100 beats) are simulated using the rate adjustable ECG simulator Cardiosim. Boolean indicators for these conditions are applied. The flow chart of the process is shown in the Figure 1. 2.3.2. Pulse Measurement Pulse signals are acquired using infrared LED pulse oximetry type sensor. LM 324 amplifier is used for amplifying the pulse signal acquired from subjects. The amplified signal is filtered using Moving Average Rectangular Smoothing filter. Tone measurements tool is used for measuring the amplitude and frequency. Time period and pulse rate are determined from the frequency obtained. Flow chart for pulse analysis is shown in Figure 2. The block diagram of the entire system is as shown in Figure 3. The block diagram of the entire system is as shown in Figure 4. 3. Telemedicine Module The acquired data has been transmitted using two methods, Web Publishing tool and Shared Variables available in Figure 1. Block diagram for heart rate detection. Figure 2. Block diagram for pulse rate detection. Figure 3. Block diagram of telemedicine system.

P. R. MITRRA ET AL. 581 LabVIEW. The above stated methods utilize TCP/IP to transfer the data via the Internet. 3.1. Web Publishing Tool LabVIEW has a built in Web Server that can be used to publish front panel images by creating a HTML document. This tool produces Joint Photographic Experts Group (JPEG) and Portable Network Graphics (PNG) image formats of the front panel. There are three modes for displaying the images of the front panel, snapshot mode for publishing static images, monitoring mode for publishing animated images with a configurable refresh interval and the embedded mode which enables the viewing and control of the webpage by the end user [10]. The Front Panel of the real time ECG and Pulse monitoring system is selected in the embedded mode in the web publishing tool to allow viewing and control by the end user. Additional information other than the inclusion of front panel can be specified before the generation of the HTML document. The URL of the generated HTML document is then created. This URL can be used in other computers connected via the LabVIEW Web Server to view the front panel. Also, the client can request for access to control the Front panel. 3.2. Shared Variables Shared Variables available in LabVIEW is used to share data across the web using NI Distribution System Manager. This method necessitates the availability of the Shared Variable engine in both the remote and client computer. From among the three types of Shared Variables that can be used viz. Single process, Network and Time Triggered, Network type is used in this work. Network Shared Variables are used to read and write data via Ethernet, using NI Publish and Subscribe Protocol (NI-PSP). Shared variable engine is used to host the variables on network after deployment. The shared variables can be transferred in a local network connected by a LAN and Wi-Fi. Two separate variables are to be created, one on the server side and the other on the client side. The variables can be viewed using NI Distribution System Manager and can be continuously refreshed. Numeric data along with its trend can be shared using the above process. 4. Results and Discussion The ECG and PPG VIs have been combined into a single Telemedicine System using Sub-VIs in LabVIEW. Figure 5 shows the front panel of the consolidated system. Figure 4. Simulation for abnormal condition. Figure 5. Final front panel of telemedicine system (TRAN- SMISSION SIDE).

582 P. R. MITRRA ET AL. Figure 6 shows the output in a web browser obtained using Web Publishing Tool. The client computer displaying the output of numerical value of Heart Rate transmission using Shared Variables is shown in Figure 7. Similarly, the Pulse Rate transmission output using Shared Variables can be seen by altering the view in the same window. The output of Web Publishing Tool is viewed using any web browser with the URL of the VI. The numerical values such as the Heart and the Pulse Rates are transmitted efficiently using Shared Variables, thus saving bandwidth. The results obtained are compared with previously existing systems. One such system [11] uses TCP/IP programming in LabVIEW to transmit a single channel of ECG. This system proves to be more efficient in terms of transmitting multiple parameters with minimum delay. The proposed method deploying Shared Variables saves more bandwidth when compared to the previous system [4]. The range of Wi-Fi used is 100 m radius [12], which is better when compared to Bluetooth [1] range of 10 m. Figure 6. Web browser showing the front panel (RECEIVING SIDE). Figure 7. Transmitting heart rate using shared variables.

P. R. MITRRA ET AL. 583 Also, Web Publishing tool output can be published on any system with LabVIEW Web Server. Since the proposed system uses LabVIEW for signal processing, it is easy to use and maintain with low energy consumption, unlike the system [2] which uses a high end ARM processor. 5. Conclusion The ECG and Pulse signals were successfully acquired, preprocessed and transmitted using the transmission methods available in LabVIEW viz. Web Publishing tool and Shared Variables. The output of Web Publishing Tool is viewed using any web browser and numerical values such as the Heart and the Pulse Rates are transmitted efficiently, thus saving bandwidth. The potential usefulness of this two channel low-cost, low-power telemedicine system is aimed for improving rural health monitoring. Further enhancement of this work would be to extend it to a multiple physiological parameter transmission module with provision for storage of waveforms and other data. REFERENCES [1] M. J. Deghani, A. R. Shahabina and A. A. Safari, Implementation of wireless based Bluetooth technology for Biosignal Monitoring, World Applied Sciences Journal, Vol. 3, 2010,pp. 287-293. [2] X. B. Shen, J. P. Zeng and T. D. Hin, Remote Healthcare Monitoring System, International Conference on Biomedical Engineering and Informatics, Vol. 3, 2010, pp. 1901-1905. [3] H.-L. Chan, C.-Y. Lu, C.-H. Liu and M.-A. Lin, Low- Power Wireless Transmission of Biosignals Using the Stotted ALOHA Mechanism, IEEE International Conference on Systems, Man and Cybernetics, Vol. 1, 2006, pp. 513-517. [4] X. Tan, X.-M. Guo, M. Cheng, Y. Yan, College of Bioengineering, Chongqing University, Chongqing, Wireless Telemedicine Physiological Monitoring Center Based on Virtual Instruments, The 1st International on Bioinformatics and Biomedical Engineering, Wuhan, 6-8 July 2007, pp. 1157-1160. [5] National Instruments, Integrated Suite of 12 Instruments for Interative, Cost-Effective, Multidisciplinary, Hands- On Learning [Data File], 2008. http://www.addlink.es/pdf/agdweb1711.pdf [6] Low Cost Low Power Instrumentation Amplifier AD620 [Data File]. 1999. http://www.stanford.edu http://www.stanford.edu/class/ee122/parts_info/datasheet s/ad620.pdf [7] P. Sauravh and M. Madhuchhanda, Detection of ECG Characteristic Points Using Multiresolution Wavelet Anaylsis Based Selective Coefficient Method, Elsevier Measurement, Vol. 43, No. 2, 2010, pp. 255-261. [8] N. Akshay, N. A. V. Jonnabhotla, N. Sadam and N. D. Yeddanapudi, ECG Noise Removal and QRS Complex Detection Using UWT, IEEE International Conference on Electronics and Information Engineering (ICEIE), Kyoto, 1-3 August 2010, pp. 438-442. [9] M. R. Rangaraj, Biomedical Signal Analysis A Case Study Approach, IEEE Press, Calgary, 2002, pp. 187-190. [10] P. F. Li and L. H. Nie, Remote control Laboratory based on LabVIEW, 2nd International Conference on Intelligent Computation Technology and Automation, Vol. 4, 2009, pp. 84-87. [11] H. Shekhar, J. S. J. Kumar, V. Ashok and A. V. Juliet, Applied Medical Informatics Using LabVIEW, 2nd International Conference on Intelligent Systems, Modelling and Simulation, Vol. 2, 2010, pp. 198-203. [12] B. Sidhu, H. Singh and A. Chhabra, Emerging Wireless Standards WiFi, ZigBee and WiMAX, World Academy of Science, Engineering and Technology, Vol. 25, 2007, pp. 1345-1349.