Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Similar documents
Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management Compact Power Transducer Type CPT-DIN Basic version

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy meters Type EM2-DIN

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Modular Smart Power Transducer Type SPT-90

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Analyzer Type EM210

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Analyzer Type EM210 MID

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Energy Management Compact Power Transducer Type CPT-DIN Advanced version

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Modular Smart Power Quality Analyzer Type WM3-96

Energy Management Energy Meter GM3D

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM270-72D

ENGLISH WM3-96. ISE, Inc Royalton Rd. - Cleveland, OH USA - Tel: (440) Fax: (440)

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Smart Modular Power Analyzer Type WM30 96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96

EN61036 EN61268 CARLO GAVAZZI

Energy Management Energy Meter Type EM112

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM111

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Meter Type EM340

Energy Management Modular Power Quality Transducer Type PQT-90

Energy Management Energy Meter Type EM110

emeter1 Single-phase energy meter emeter3 Three-phase energy meter User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM111

ENGLISH WM2 - DIN / EM2 - DIN OPERATING INSTRUCTIONS. General features 2. WM2-DIN Technical features 3. EM2-DIN Technical features 9.

Energy Management Smart Modular Power Analyzer Type WM30 96

Energy Management Smart Modular Power Analyzer Type WM30 96

Energy Management Modular Smart Power Quality Analyzer Type WM5-96

Energy Management Smart Modular Power Analyzer Type WM30 96

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Modular Smart Power Quality Analyzer Type WM5-96

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

ENGLISH. General features 2. Technical features 2. Installation 5. Preliminary operations 7. Front panel description 8.

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Smart Modular Power Analyzer Type WM40 96

Energy Management Smart Modular Power Analyzer Type WM40 96

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Power Meter Series PM3200 Functions and characteristics

EM-72 Electricity Meters for Current Transformers

Multimeter 500CVD21 RTU500 series

ENGLISH OPERATING INSTRUCTIONS. General Features 2. Technical Features 3. Installation 9. Preliminary Operations 11. Front Panel Description 12

Technical Data Sheet. x1000. kwh R Y B

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Monitoring Electric Network Via Internet

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Jewell DPM EINE BEST IN CLASS

Current Clamp. 210

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Measurement and control. Digital instruments and measuring transducers

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

RS Pro ENGLISH. Datasheet

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

ME432 Three-phase Power Meter

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Centrale de mesure Power Meter PM500 Merlin Gerin

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Data Sheet. RISH Master Record %THD

GAMMA 20 DIGITAL MULTIMETER

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Power Meter Series PM9

Transcription:

Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements: W, W dmd, var, VA, VA dmd, PF, V, A, An, Hz A max, W dmd max indication TRMS meas. of distorted sine waves (voltages/currents) Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC Protection degree (front): IP 40 Front dimensions: 6 DIN modules Optional RS422/485 serial output Alarms (visual only) V LN, An Product Description 3-phase multifunction power indicator with built-in programming key-pad. Particularly recommended for displaying the main electrical Type Selection variables. Housing for DIN-rail mounting, (front) protection degree IP40 and optional RS485 serial output. How to order Model Range code System Power supply Option WM12-DIN AV5 3 D X Range codes System Power supply Options AV5: AV6: 400/660V L-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V 100/208V L-L/5(6)AAC VL-N: 45 V to 145 V VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A Input specifications 3 : 1-2-3-phase, unbalanced load, with or without neutral Rated inputs Current 3 (shunt) Voltage 4 Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25 C ±5 C, R.H. 60%) 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL Current 0.25 to 6A: ±(0.5% FS +1DGT) 0.03A to 0.25A: ±7DGT Neutral current 0.25 to 6A: ±(1.5% FS +1DGT) 0.09A to 0.25A: ±7DGT Phase-phase voltage ±(1.5% FS +1 DGT) Phase-neutral voltage ±(0.5% FS + 1 DGT) Active and Apparent power, 0.25 to 6A: ±(1% FS +1DGT); Power factor 0.03A to 0.25A: ±(1% FS +5DGT) Reactive power 0.25 to 6A: ±(2% FS +1DGT); 0.03A to 0.25A: ±(2% FS +5DGT) Frequency ±0.1%Hz (48 to 62Hz) Additional errors Humidity 0.3% FS, 60% to 90% RH Temperature drift 200ppm/ C A: 24VAC B: 48VAC C: 115VAC D: 230VAC 3: 18 to 60VDC Sampling rate Display refresh time Display Type Read-out for the instant. var. Measurements Coupling type Crest factor X: None S: RS485 output 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 9mm 3x3 DGT Current, voltage, power, power factor, frequency TRMS measurement of distorted waves. Direct < 3, max 10A peak Input impedance 400/660V L-L (AV5) 1 MΩ ±5% 100/208V L-L (AV6) 453 KΩ ±5% Current 0.02Ω Frequency Overload protection Continuos voltage/current For 500ms: voltge/current 48 to 62 Hz 1.2 F.S. 2 Un/36A Specifications are subject to change without notice WM12-DINDS0703 1

RS485 Serial Output Specifications RS422/RS485 (on request) Type Connections Addresses Protocol Multidrop bidirectional (static and dynamic variables) 2 or 4 wires, max. distance 1200m, termination directly on the instrument 1 to 255, key-pad selectable MODBUS/JBUS Data (bidirectional) Dynamic (reading only) Static (writing only) Data format Baud-rate System and phase variables All configuration parameters 1 bit di start, 8 data bit, no parity, 1 stop bit 9600 bit/s Software functions Password Numeric code of max. 3 digits; 2 protection levels of the programming data 1st level Password 0, no protection 2nd level Password from 1 to 999, all data are protected System selection 3-phase with neutral 3-phase without neutral 3-phase ARON 2-phase Single phase Transformer ratio CT 1 to 999 VT 1.0 to 99.9 Filter Operating range Filtering coefficient 1 to 16 Filter action 0 to 99.9% of the input electrical scale Measurements, alarms, serial output (fundamental variables: V, A, W and their derived ones). Power Supply Specifications Displaying 3-phase system with neutral Alarms Reset Up to 3 variables per page Page 1: V L1, V L2, V L3 Page 2: V L12, V L23, V L31 Page 3: A L1, A L2, A L3 Page 4: An Page 5: WL1, WL2, WL3 Page 6: PF L1, PF L2, PF L3 Page 7: var L1, var L2, var L3 Page 8: VA L1, VA L2, VA L3 Page 9: VA, W, var Page 10: VA dmd, W dmd, Hz Page 11: W dmd MAX Page 12: VL-L, PF Page 13: A MAX Programmable, for the VL and An (neutral current). Note: the alarm is only visual, by means of LED on the front of the instrument. Independent alarm (VL, An) max: A, Wdmd Auxiliary power supply 230VAC 115VAC 48VAC Power consumption 24VAC 18 to 60VDC AC: 4.5 VA DC: 4W General Specifications Operating temperature Storage temperature Installation category Insulation (for 1 minute) 0 to +50 C (32 to 122 F) (RH < 90% non condensing at 40 C) -10 to +60 C (14 to 140 F) (RH < 90% non condensing at 40 C) Cat. III (IEC 60664, EN60664) 4000VAC, 500VDC between mesuring inputs and power supply. 500VAC/DC between mesuring inputs and RS485. 4000VAC, 500VDC between power supply and RS485. Dielectric strength 4000 VAC (for 1 minute) EMC Emissions EN50084-1 (class A) residential environment, commerce and light industry 2 Specifications are subject to change without notice WM12-DINDS0703

General Specifications (cont.) Immunity EN 61000-6-2 (class A) industrial environment. Pulse voltage (1.2/50µs) EN61000-4-5 Safety standards IEC 60664, EN60664 Approvals CE Connections 5(6) A Screw-type Max cable cross sect. area 2.5 mm 2 Housing Dimensions (WxHxD) 107.8 x 80 x 64.5 mm Material Mounting Protection degree Weight ABS self-extinguishing: UL 94 V-0 DIN-rail Front: IP40 Connections: IP20 Approx. 400 g (pack. incl.) Waveform of the signals that can be measured Figure D Sine wave, undistorted Fundamental content 100% Harmonic content 0% A rms = 1.1107 A Figure E Sine wave, indented Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum: 3rd to 16th harmonic Additional error: <1% FS Figure F Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum: 3rd to 16th harmonic Additional error: <0.5% FS Display pages Display variables in 3-phase systems (in a 3-phase system with neutral) No 1 st variable 2 nd variable 3 rd variable Note 1 V L1 V L2 V L3 2 V L12 V L23 V L31 Decimal point blinking on the right of the display 3 A L1 A L2 A L3 4 An AL.n AL.n if neutral current alarm is active 5 W L1 W L2 W L3 Decimal point blinking on the right of the display if generated power 6 PFL1 PFL2 PFL3 7 VAR L1 VAR L2 VAR L3 Decimal point blinking on the right of the display if generated power 8 VA L1 VA L2 VA L3 9 VA system W system VAR system 10 VA dmd W dmd Hz dmd = demand (integration time (system) (system) (system) selectable from 1 to 30 minutes) 11 W dmd MAX Maximum sys power demand 12 V LL system AL.U PF system AL.U= is activated only if one of VLN is not within the set limits 13 A MAX max. current among the three phases Specifications are subject to change without notice WM12-DINDS0703 3

Used calculation formulas Phase variables Instantaneous effective voltage Instantaneous active power Instantaneous power factor Instantaneous effective current Instantaneous apparent power Instantaneous reactive power System variables Equivalent 3-phase voltage 3-phase reactive power 3-phase active power 3-phase apparent power 3-phase power factor Neutral current An = A L1 + A L2 + A L3 Wiring diagrams Fig. 1 Fig. 2 Fig. 3 CT connection 3CT and 3VT connection ARON connection Fig. 4 Fig. 5 RS485 serial connection Fig. 6 ARON and VT connection 2-phase connection [1] [2] [3] 1-Last instrument 2-1...n Instrument 3-SIU-PC 4-wire connection NOTE: the current inputs can be connected to the lines ONLY by means of current transformers. The direct connection is not allowed. 4 Specifications are subject to change without notice WM12-DINDS0703

Front Panel Description 2 1 1. Key-pad To program the configuration parameters and the display of the variables. S Key to enter programming and confirm selections; Keys to: - programme values; - select functions; - display measuring pages. 2. Display LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. Dimensions and Panel Cut-out 90mm 44mm 107,8mm 32,2mm 50,1mm 64,5mm 45mm 108,5mm Specifications are subject to change without notice WM12-DINDS0703 5