Product Dimensions (Width x Length x Height) (inches)

Similar documents
Thurston County Permitting System Policies &Procedures Page: 1 of 3

On-Site Sewage Disposal Application Packet

SECTION MANHOLES

Onlot System Component Matrix

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422

A. Dewatering observation wells are part of dewatering allowance.

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

Customer Requirements Commercial Secondary Service

9/17/90 (rev.) STATE OF MINNESOTA HINNESOTA DEPARTMENT OF HEALTH

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

City of Malibu Coastal Development Permit Onsite Wastewater Treatment System Submittal Checklist

For crossing under a railroad, contact the specific railroad company's engineering department.

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

Work Type Definition and Submittal Requirements Work Type: Subsurface Utility Engineering (SUE)

Grease Interceptor Design Checklist

Crow Wing County Mound Design

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Town of Skowhegan Application For Development Review

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

PLANNING AND DEVELOPMENT

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

List of Figures. List of Forms

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS

PRELIMINARY PLAT CHECK LIST

Subdivision Application Checklist

Yavapai County Development Services

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Plastibeton Trench System. Installation Packet

SECTION 9: ROOF STRUCTURE, ROOFING MATERIALS AND FLASHING, GUTTER, DOWNSPOUTS, AND SKYLIGHTS. Background

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

Oil-Water Separator Design Checklist

SECTION TRACER WIRE FOR NONMETALLIC PIPE

VINTAGE ORIGINAL ART MURAL REGISTRATION PROCESS

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

580 - NOISE BARRIERS OPSS 580 INDEX

CUTTING THE PIPE: BLUE DUCT Pipe can be easily cut using a Circular Saw or Reciprocal Saw. Trim all edges as necessary.

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

BOOTH CONSTRUCTION & DISPLAY REQUIREMENTS Huntington Convention Center Cleveland, Ohio February 7 9, 2018

Grading, Erosion and Sediment Control (GESC) Checklist

Plastibeton Trench System. Installation Packet

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS

CONSTRUCTION CERTIFICATION PACKAGE

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

ROOFING City of Grand Rapids Building Safety Division

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

Public Works City of Lebanon, Tennessee; Department of Public Works

Washington County Road Engineering Plan Submittal/Review Checklist

APPENDIX K DEPARTMENT OF PLANNING AND CODE ENFORCEMENT SUBDIVISION APPLICATION CENTER SUBMITTAL CHECKLIST

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

City of Colleyville Community Development Department. Site/Landscape Plan Application Packet

2014 Bentley Systems, Incorporated. Industry Futures Dean Bowman, PE Bentley Fellow Bentley Systems

ARTICLE 3: WATERSHED MANAGEMENT PERMIT REQUIREMENTS AND SUBMITTALS

Peters Township Sanitary Authority 3244 Washington Road McMurray, PA 15317

Subsurface Sewage Treatment Systems (SSTS) Technical Advisory Panel (TAP) for Product Registration

INSTALLATION OF PYRAMAT FOR CHANNELS

Information for File # RMM

Appendix C Construction Details

Promontory Architectural Review Committee

Signs and Murals - Definitions:

PROJECT INSTRUCTIONS Roofing

CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS

Denison Sherman. Paris. Gainesville. Denton McKinney. Mount Pleasant. Dallas Fort Worth Arlington Marshall Mansfield. Longview Waxahachie

1 copy of all plans in pdf format and I copy of this form must be submitted, or it will be returned because it is an incomplete submittal.

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

B-PERMIT PLAN CHECK MANUAL

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

PLANNING DEPARTMENT SUBMITTAL REQUIREMENTS FOR CONDITIONAL USE PERMITS CLASS 4 DEVELOPMENT REVIEW PROCESS. A. Written Material

Facility Services Subgroup Preface for Divisions 21` through 28

CONSULTANT ACCREDITATION SCHEME SEWER DESIGN

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Plan Review and Standards

3. The PAC (Permit Application Center) will notify the design professional of plan review results.

Checklist for Tentative Subdivision Map

SECTION III SUBMITTALS AND APPROVALS

Last updated 8/26/2013

Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version -

Customer Connection Guide Updates Effective May 2017

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

SITE PLAN Application Packet (Required For All Non-Residential Development Projects)

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Aquaflex Universal Soil Moisture Sensor (Model SI.162-Pulse) -User Manual- Pulse Version -

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Application for Site Plan Review

SECTION 2 GENERAL REQUIREMENTS

Installing a COMROD AS1R Whip Antenna with Anchor Post

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges

Conceptual, Preliminary and Final Site Plan Review in Holladay City

Transcription:

Mr. Dennis Hallahan, P.E. Infiltrator Water Technologies 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 RE: Product Registration Renewal #2 Notice of Proprietary Distribution Product Listing Description: Proprietary Distribution Product - Gravelless Distribution Media Manufacturer: Infiltrator Systems, Incorporated Product Name: Arc Chamber Series Numbers: Arc 18, Arc 24, Arc 36, Arc 36 Low Profile, & Arc 36 High Capacity Product File No: 2016-008 Dear Mr. Hallahan: Thank you for your application for product renewal dated November 18, 2012, for the Infiltrator Water Technologies Arc model chamber series, which includes the following models: Arc 18, Arc 24, Arc 36, Arc 36 Low Profile (LP) and Arc 36 High Capacity (HC). In accordance with Minnesota Rules Chapter 7080 through 7083, the Minnesota Pollution Control Agency (MPCA) has reviewed submitted materials for proprietary distribution product registration. Based on the submitted documentation, the MPCA finds the Arc model chamber series is eligible to be registered and meet the requirements for proprietary distribution product registration. As such, the Arc model chamber series is registered for use in trench, seepage bed, at-grade and mound applications, in accordance with Minnesota Rules Chapter 7080.2200 through 7080.2350 and the manufacturer s installation requirements. Gravity and pressure distribution requirements, as described in Minnesota Rules Chapter 7080.2050, shall be met. Table 1 lists registered chamber models and dimensions as presented in the initial application submittal, dated December 21, 2009, and related documents and a second application submitted for the Arc 36 Low Profile (LP) on February 18, 2011. Table 1. ADS Arc Chamber s and Dimensions Product Dimensions Average Open Bottom Width (feet) Average Sidewall Infiltrative Height Arc 18 16 x 60 x 12 1.12 7.6 Arc 24 22 x 60 x 12 1.59 7.6 Arc 36 34 x 60 x 13 2.39 7.1 Arc 36 Low Profile (LP) 34 x 60 x 8 2.45 6.0 Arc 36 High Capacity (HC) 34 x 60 x 16 2.45 10.3 wq-wwists4-65a

wq-wwists4-65a

Page 3 Subject to this determination, the Arc model chamber series will be placed on the List of Registered Subsurface Sewage Treatment System (SSTS) Proprietary Distribution Media Products at the sizing recommended by the Technical Advisory Panel on January 21, 2010, March 17, 2011, May 19, 2011, and reflected in this letter of registration. The product information listed in this Notice of Proprietary Product Listing will be maintained on the MPCA website and may not be altered by the manufacturer without permission from the MPCA. Soil absorption areas using Arc chambers may be sized based on the sizing charts included in this Notice of Proprietary Distribution Product Listing, or may be sized larger at the direction of local regulatory authorities. Product drawings contained in the manufacturer s manual provide information on the open bottom area for each product listed in Table 1. The following design applications for trenches, seepage beds, at-grades and mounds are based on the Registered Sizing as recommended by the Technical Advisory Panel. When the local regulatory authority chooses to size the Arc chamber product based on the chamber inside dimensions, additional calculations will need to be made to determine the number of chambers required in each application. Trench Applications For trench applications, the following shall be the basis for establishing equivalency for nominal chamber width to trench width: A 16-inch-wide chamber is equivalent to an 18-inch-wide trench using drain field rock A 22-inch-wide chamber is equivalent to a 24-inch-wide trench using drain field rock A 34-inch-wide chamber is equivalent to a 36-inch-wide trench using drain field rock Where trench designs are specified, new construction or replacement systems, may utilize the Arc chambers in accordance with Table 2. Trenches must be no more than 36 inches wide. All excavations wider than 36 inches shall be considered seepage beds. Table 2. Trench Sizing Dimensions Sizing in Trenches Arc 18 16 x 60 x 12 Arc 24 22 x 60 x 12 Arc 36 34 x 60 x 13 Arc 36 Low Profile (LP) 34 x 60 x 8 Arc 36 High Capacity (HC) 34 x 60 x 16 Chamber trench length at 1:1 ratio with drainfield rock trench length Backfilling along the chamber sidewall absorption area shall be done in a manner that: 1) maintains the ability of the soil to adequately infiltrate and disperse wastewater and 2) prevents the intrusion of soil into the chamber through the louvered sidewall. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual.

Page 4 Vertical inspection pipes must be properly installed in the distribution medium of all trenches as per Minnesota Rules Chapter 7080.2210, subp. 4(B). The inspection pipe must be located at the end opposite from where the effluent enters the distribution medium. The manufacturer s installation instructions for trench systems shall illustrate this requirement. Seepage Bed Applications Seepage bed designs shall be sized based on bottom area only with no additional credit given to sidewall. When a seepage bed is specified with a design width of less than or equal to 12 feet, gravity distribution may be utilized. Seepage bed designs greater than 12 feet and up to 25 feet in width shall require pressure distribution. Table 3 provides Arc chamber configurations for seepage bed applications using the Registered Sizing. Table 3. Seepage Bed Sizing Nominal Dimensions Arc 24 Arc 36 Arc 36 Low Profile (LP) Arc 36 High Capacity (HC) 22 x 60 x 12 34 x 60 x 13 34 x 60 x 8 34 x 60 x 16 Number of Chambers Bed Design Width Spanning Bed Width (feet) 2 4 3 6 4 8 5 10 5 15 5 15 5 15 Backfilling along the chamber sidewall absorption area shall be done in a manner that prevents the intrusion of soil into the chamber through the louvered sidewall. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual. Vertical inspection pipes must be properly installed in the distribution medium of all seepage bed systems as per Minnesota Rules Chapter 7080.2210, subp. 4(B). The inspection pipe must be located at the end opposite from where the effluent enters the medium. The manufacturer s installation instructions for seepage bed systems shall illustrate these requirements. One inspection pipe per seepage bed is sufficient; it is not necessary to install an inspection pipe in each run of chambers. At-Grade Applications Arc chambers are registered for use in at-grade systems on both flat sites and on sloping sites. At-grade designs shall be sized based on bottom area only with no additional reduction given to sidewall.

Page 5 At-grades should be long and narrow, with individual contour loading rates ranging between two and eight gallons per lineal foot per day. Proper scarification of the absorption area is required before Arc chamber products are installed in at-grade systems. The maximum allowable width for at-grade distribution media beds is 15 feet. Table 4 provides Arc chamber configurations when utilized in atgrade systems applications using the Registered Sizing. Backfilling along the chambers shall be done in a manner that prevents the intrusion of soil into the chamber through the louvered sidewall. The required backfill material includes six inches of sandy cover material over the chambers, extending at least five feet beyond the ends of the chambers, and six inches of topsoil. The backfill material shall be properly sloped to divert surface water away from the system. The method of soil placement over the at-grade shall be done as specified by the manufacturer in the installation manual. One vertical inspection pipe must be properly installed along the down slope portion of at-grade absorption beds as per Minnesota Rules Chapter 7080.2230, subp. 3(G). The manufacturer s installation instructions for at-grades shall illustrate this requirement. Table 4. At-Grade Sizing Arc 24 Arc 36 Arc 36 Low Profile (LP) Arc 36 High Capacity (HC) Mound Applications Dimensions 22 x 60 x 12 34 x 60 x 13 34 x 60 x 8 34 x 60 x 16 Number of Chambers Spanning At-Grade Width At-Grade Design Distribution Media (feet) 2 4 3 6 4 8 Mound designs shall be sized based on bottom area only with no additional reduction given to sidewall. Mounds should be long and narrow, with contour loading rates ranging between one and twelve gallons per lineal foot per day. The maximum allowable width for mound distribution media beds is nine feet.

Page 6 Table 5 provides Arc chamber configurations when utilized in mound applications using the Registered Sizing. The area around the Arc chambers, and in-between the chambers in mounds, shall be filled with clean sand up to the top of the louvered sidewall. The manufacturer s installation manual shall provide a detailed drawing showing this requirement. Backfilling along the chambers shall be done in a manner that prevents the intrusion of soil into the chambers through louvered sidewalls. Backfill material type and method of placement shall be done as specified by the manufacturer in the installation manual. One vertical inspection pipe must be properly installed at the end of each mound, terminating at the mound sand and chamber interface, per Minnesota Rules Chapter 7080.2220, subp. 3(O). The manufacturer s installation instructions for mounds shall illustrate this requirement. Table 5. Mound Sizing Arc 36 Arc 36 Low Profile (LP) Arc 36 High Capacity (HC) Side Port Coupler (SPC) Product Dimensions 34 x 60 x 13 34 x 60 x 8 34 x 60 x 16 Number of Chambers Spanning Mound Distribution Mound Width Media Width (feet) Each Arc chamber model listed includes, as an accessory, Side Port Coupler (SPC) parts. The SPC may be used in three ways: 1) placed at the end of the chamber line and used in conjunction with the universal end cap; 2) installed by itself between individual Arc chambers; and 3) installed in series between individual Arc chambers. Although these SPC parts provide some bottom absorption area, this area is not included as part of the absorption area for trench, seepage bed, at-grade or mound system designs, unless specifically allowed by the local permitting authority. The manufacturer s manual shall describe each of these applications, and specify the recommended absorption area for each Arc chamber SPC. General Requirements The registration of products in Minnesota is contingent upon compliance with the following conditions: 1. The manufacturer shall have readily accessible information, specific to a product's registered use in Minnesota, for designers, installers, regulators, system owners, and service providers for the following items: a) product manual; b) design instructions; c) installation instructions; d) information regarding operation and maintenance; e) homeowner instructions and f) list of manufacturercertified service providers, if any, as required by Minnesota Rules Chapter 7083.4040 (H).

Page 7 2. Distribution of sewage by means of gravity and pressure are permissible, in accordance with Minnesota Rules Chapter 7080.2050 and the manufacturer s installation requirements. The distribution of effluent shall be done in a manner that does not scour or excessively pit the soil s infiltrative surface or cause sealing from fines at the soil s infiltrative surface. 3. Soil loading rates shall be as specified in Minnesota Rules Chapter 7080.2150, subp.3. Tables IX and IXa and in Minnesota Rules Chapter 7080.2350. 4. No additional consideration shall be given to the Arc chamber Side Port Coupler (SPC) to size trench, seepage bed, at-grade and mound systems, unless specifically allowed by the local permitting authority. 5. The minimum depth of soil cover, including six inches of topsoil borrow, over Arc chamber products used in trenches, seepage beds, at-grades and mounds is 12 inches. 6. Any excavation into the absorption area must be in a manner that maintains soil structure in an unsmeared and un-compacted condition. Excavation and placement of Arc chamber products are allowed when: 1) the soil moisture is less than the plastic limit and 2) the soil is not frozen or freezing per Minnesota Rules 7080.2150, subp. 3(G). 7. Placement of Arc chamber products shall be performed in a manner that minimizes soil compaction due to foot traffic related to the installation of chamber products. 8. Arc chamber products shall be installed so they do not: 1) sink, 2) separate, 3) allow for the intrusion of soil into the chambers through the louvered sidewalls and 4) provide a home for burrowing animals, which partially or completely fills the chamber system with soil. 9. Training shall be provided to practitioners in the proper application and use of the Arc chamber products registered for use in Minnesota. 10. During the period of product registration and as part of the renewal process, systems using registered distribution products are subject to an audit established by the MPCA. Please be advised that this registration expires on December 31, 2018. Manufacturers desiring to continue product registration beyond this date must obtain MPCA renewal according to the requirements in Minnesota Rules 7083.4080, subp. 5. If the MPCA finds the product has changed in any way that may affect performance, it may not be renewed and must meet the requirements for initial registration. The MPCA is in no way endorsing these products or any advertising, and is not responsible for any situation which may result from its use or misuse. The MPCA is not liable for any product failure and these statements are not intended and cannot be relied upon to establish any substantive or procedural rights with the state of Minnesota or the MPCA, either express or implied, that can be enforced in litigation or any administrative proceeding.

Page 8 If you have any question, please contact Aaron S. Jensen at 651-757-2544 or by email at Aaron.S.Jensen@state.mn.us. Sincerely, Aaron S. Jensen SSTS Coordinator SSTS Section Municipal Division ASJ:wgp cc: File