MAINS SIGNAL PROPAGATION THROUGH DISTRIBUTION SYSTEMS. J. Stones*, S. Perera*, V. Gosbell* and N. Browne**

Similar documents
Distribution Network Capacitor Resonance A Case Study

POWER FACTOR CORRECTION AND ITS PITFALLS

Ripple signal amplification in distribution systems: a case study

EE 340 Transmission Lines

Harmonic resonances due to transmission-system cables

EE 741. Primary & Secondary Distribution Systems

A STUDY CASE ON HARMONIC DISTORTION CREATED BY WIND TURBINES

Some aspects regarding harmonic s distortions propagation in large medium voltage distribution system

Frequency Domain Analysis of Capacitor Transient Overvoltages

Harmonic Planning Levels for Australian Distribution Systems

Fatima Michael college of Engineering and Technology

EE 340 Transmission Lines. Spring 2012

Power Quality and Reliablity Centre

INVESTIGATION INTO THE HARMONIC BEHAVIOUR OF MULTIPULSE CONVERTER SYSTEMS IN AN ALUMINIUM SMELTER

Harmonics Issues that Limit Solar Photovoltaic Generation on Distribution Circuits

EE 740 Transmission Lines

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

ELEC Transmission i and

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

Aggregated Rooftop PV Sizing in Distribution Feeder Considering Harmonic Distortion Limit

UNDERSTANDING POWER QUALITY

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

Maximum Allowable PV Penetration by Feeder Reconfiguration Considering Harmonic Distortion Limits

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

SOURCES OF ERROR IN UNBALANCE MEASUREMENTS. V.J. Gosbell, H.M.S.C. Herath, B.S.P. Perera, D.A. Robinson

Harmonic impact of photovoltaic inverter systems on low and medium voltage distribution systems

Solving Customer Power Quality Problems Due to Voltage Magnification

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

Power Quality Requirements for Connection to the Transmission System

Delayed Current Zero Crossing Phenomena during Switching of Shunt-Compensated Lines

ANALYSIS OF ACTIVE POWER FILTER FOR HARMONIC VOLTAGE RESONANCE SUPPRESSION IN DISTRIBUTION SYSTEM

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

Application of Reactive Compensation equipment in industrial systems under aspects of harmonics and switching transients: A study of real case

The development of the SA grid code on Power Quality emission. Dr. Gerhard Botha 2017/08/08

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Power Quality Summary

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Assessment of Saturable Reactor Replacement Options

Effects of Harmonic Distortion I

Exercises on overhead power lines (and underground cables)

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Key-Words: - capacitive divider, high voltage, PSPICE, switching transients, high voltage measurements, atmospheric impulse voltages

Emicon Engineering Consultants L.L.C.

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

Characteristics of power quality disturbances in Australia: voltage harmonics

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

COMPARATIVE INVESTIGATION OF SHUNT ACTIVE POWER FILTERS IN 25kV AC ELECTRIFIED SYSTEMS

Grid Impact of Neutral Blocking for GIC Protection:

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

Experience in the application of IEC/TR to harmonic allocation in transmission systems

Statistical analysis of overvoltages due to the energisation of a 132 kv underground cable

Conventional Paper-II-2013

ASPECTS OF REAL-TIME DIGITAL SIMULATIONS OF ELECTRICAL NETWORKS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

FERRORESONANCE - its Occurrence and Control in Electricity Distribution Networks

Primary Metering. What is Primary Metering?

Sizing the neutral wire cross-section and minimization of neutral currents using microgeneration in low voltage networks

Impact of Distributed Generation on Network Voltage Levels

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

Influence of Switching Elements on Harmonics and Power Factor Improvement

Design and Simulation of PFC Circuit for AC/DC Converter Based on PWM Boost Regulator

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

Power Quality Measurements the Importance of Traceable Calibration

Harmonic Analysis Model Based on 8-port Representation for Korean High Speed Railway

Impact of Distributed Generation on Voltage Regulation by ULTC Transformer using Various Existing Methods

Determination of Optimal Account and Location of Series Compensation and SVS for an AC Transmission System

THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES

Tabor Electronics Signal Amplifiers. Quick Start Guide

The Design of E-band MMIC Amplifiers

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

Harmonic Levels and Television Events

Flicker Attenuation Part II: Transfer Coefficients for Regular Voltage Fluctuations in Radial Power Systems With Induction Motor Loads

POWER QUALITY ASSESSMENT AND MITIGATION AT WALYA-STEEL INDUSTRIES AND ETHIO-PLASTIC SHARE COMPANY

Harmonic Filtering in Variable Speed Drives

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

Hours / 100 Marks Seat No.

Distributed Active Filter Systems (DAFS): A new approach to power system harmonics

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM

Ferroresonance Experience in UK: Simulations and Measurements

Conventional Paper-II-2011 Part-1A

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

New Methods to Mitigate Distribution System Harmonics

Published in: IECON 2016: The 42nd Annual Conference of IEEE Industrial Electronics Society

Voltage and Current Waveforms Enhancement using Harmonic Filters

Chapter 2 Shunt Active Power Filter

POWER QUALITY IMPACTS AND MITIGATION OF DISTRIBUTED SOLAR POWER

An Audio Frequency Model of a 2x25 kv Traction Line for High Speed Railway Systems

Chapter 2. The Fundamentals of Electronics: A Review

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

Efficient Hybrid Shunt Active Power Filter for Improvement of Power Factor and Harmonic Suppression using MATLAB

Endeavour Energy Power Quality & Reliability Centre Voltage Sag Mitigation

Design and Analysis of Resonant Harmonic Filter

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

BAKISS HIYANA BT ABU BAKAR JKE,POLISAS

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Transcription:

ABSTRACT MAINS SIGNAL PROPAGATION THROUGH DISTRIBUTION SYSTEMS J. Stones*, S. Perera*, V. Gosbell* and N. Browne** *School of Electrical, Computer and Telecommunications Engineering University of Wollongong **Integral Energy This paper looks at a power quality problem termed Racing Clocks caused by the amplification of ripple frequency signals in distribution networks. A study of this problem has been undertaken on two kv feeder systems within the Sydney area. These two particular feeder systems were chosen as they have caused problems in the past. The purpose of this study was to determine whether the problem still exists in the areas supplied by these feeders. The present and ultimate configurations of these two feeder systems are examined and the resonance frequencies and ripple signal voltage levels are determined. Modelling techniques that were adopted in the simulation are also described. The study showed that for certain ratios of overhead to underground cable, the resonance point might occur near a problematic frequency.. INTRODUCTION Off-peak hot water systems are controlled in most areas using ripple signals. A common frequency which is used is 5Hz. Resonance frequencies exist in all electricity networks and for pure overhead systems these resonance points lie well away from 5Hz. By adding underground cables to the network, which is the current trend in developing areas, the additional capacitance which is introduced to the system becomes significant enough that the resulting resonance point can decrease to a problematic frequency. When this occurs, the 5Hz signal, which is usually around 5Vrms at the point of injection, may be amplified to a much higher level. When the ripple signal is amplified to a critical level, the number of zero crossings of the resultant voltage waveform can increase to more than the normal two per cycle. A typical waveform capture at a padmount substation when a ripple signal is being applied can be seen in Figure. The increased number of zero crossings can cause some types of digital clocks to gain time as they use zero crossings for timing purposes. This phenomenon is known as 'Racing Clocks'. The 'Racing Clock' phenomenon has been a problem in electricity distribution networks for a number of years. Several studies have been undertaken in this area to analyse the problem and attempt to find solutions. A recent study [] examined a feeder system and looked at modelling techniques adopted in PSCAD /EMTDC TM to simulate the network. Results from this study indicated high ripple signal levels. Since the above stated study, the network has been reconfigured and a fresh study was required to determine whether the unacceptable signal levels still exist. It was also required to examine another feeder system where the possibility of signal amplification was suspected. New modelling techniques were investigated in the new study, relating in particular to high frequency correction.. MODEL DEVELOPMENT. System Description voltage Figure Voltage waveform with Ripple Signal The operating characteristics of two feeder systems were investigated in this study. The two feeder systems are different in their overhead to underground cable ratio. The first feeder system, the "underground" system, contains 6.5km of overhead lines and.8km of underground cables, with an underground to overhead ratio of two thirds. The second feeder system, the "equally weighted" system, contains 4km of overhead lines and 6km of underground cables. Both feeder systems are in developing residential

C L areas in Sydney and are essentially radial. In the earlier study [], the underground feeder system was modelled using PSCAD /EMTDC TM. Reconfiguration of the system involved the movement of open points and the transfer of some loads to other feeder systems. Opportunities were taken in the new study to examine new modelling techniques relating in particular to high frequency correction in the models. Two models were developed to investigate the present operational conditions of the two feeder systems. Two further models were developed to examine the future configurations. In the ultimate configuration of the two feeder systems, approximately half of the load from underground system will be switched over to another feeder system. The underground system will therefore become a very lightly loaded system with equal amounts of overhead line and underground cable. The equally weighted system will become an almost entirely underground system in the ultimate configuration.. Modelling Details The models developed in PSCAD /EMTDC TM were single phase representations of the kv network. Underground cables were represented by the lumped π network as shown in Figure. Overhead conductors were represented with a similar model, but the capacitance was assumed to be negligible. Three different skin effect factors were applied to the resistance of each section of line. These factors were applied to compensate for skin effect at the ripple signal frequency. The factors which were used are seen in Table I. For a system with a 5Hz ripple signal, h =. Skin effect factors were tested to see the preliminary effect they had on the results when incorporated into the model. None of the factors tested applies directly to a kv system for the st harmonic. Further studies are required in determining more accurate skin effect correction factors. R Figure Underground Cable Representation C Table I Skin Effect Factors applied to line resistances (h = harmonic order) Skin Effect Correction Notes Factor.67 +. 485 h Applied in the range 75kV 4kV for any harmonic order System loads were represented at each MV/LV substation by a hybrid model of the type shown in Figure. In this model, R sh represents purely resistive loads whereas the series R se - L se branch represents motor type loads. Allocation of real power to the two parallel branches is an issue for which a clear cut answer is not available. Thus, it was necessary to trial different allocation factors to apportion the total real power at MV/LV substations. The allocation factor was termed x and values for x =.4,.5,.6 were observed. A load factor, x, was incorporated into the load model to allow the system to be modelled under both light and heavy load conditions. Light load was modelled as x =.8 and heavy load was modelled as x =.7. The values used to simulate light and heavy load were specific for the systems being modelled in this study and were estimated from field measurements. The shunt resistance of the load, R sh, is calculated by = Ω MDI x x pf R sh above 7.6 []. Applied to kv systems []..646 h + 9 +.58 h Used as a basis for comparison Voltage nominal voltage given in kv MDI Maximum demand (MVA) x allocation factor for real power x proportion of MDI at a load point pf total power factor R sh L se R se Figure Load Representation

Table II Skin Effect Factors applied to load resistances 4.5 Skin Effect Correction Notes Factor.5 h [] Used as a basis for.5.54 comparison.4.5 The series inductance of the load, L se, is calculated by 5 5 45 65 85 5 L se = H MDI sin(cos ( pf )) πf Sub A Sub B The series resistance of the load, R se, is calculated by = MDI ( x ) x R se Ω pf For all load points the overall power factor was assumed to be.9 lagging. As there is the possibility of skin effect influencing the load resistances, further correction factors were also adopted which are given in Table II. Figure 4 Resonance curves for the present configuration of the underground system. The underground system will not be a problem in its ultimate configuration, however in the transition period to its ultimate configuration, the resonance point may move to be close to 5Hz. In such a situation, the "Racing Clock" problem will re-surface. Therefore care needs to be taken to ensure that as the network is altered, the resonance point never moves to 5Hz. 4. RESULTS In the underground system, the simulation results showed that the resonance frequency is 8Hz. The amplification of the ripple signal was therefore found to be acceptable. The resonance curves for two different substations in the underground system can be seen in Figure 4 and the amplification levels at 5Hz are indicated. Sub A is closer to the point of injection of the ripple signal than Sub B. These curves were obtained from simulation results under heavy load conditions with an x of.5 and with no line or load correction factors. In the earlier study [], the resonance point was found to be at 95Hz. Since the last study, the resonance point has effectively moved further to the left of 5Hz. In the ultimate configuration of the underground system, the system contains equal amounts of overhead and underground cable. The resonance point moves across to the right of 5Hz to 6Hz. The resonance curve for one substation can be seen in Figure 5 and the amplification at 5Hz is indicated. This substation is one that is in the underground system in both the present and the ultimate configuration. This curve was obtained from simulation results under heavy load conditions with an x of.5 and with no line or load correction factors In the equally weighted system the resonance frequency is 7Hz. The amplification of the ripple signal was therefore found to be acceptable. The resonance curves for two different substations in the equally weighted system can be seen in Figure 6 and the amplification at 5Hz is indicated. Sub C is closer to the point of injection of the ripple signal than Sub D. These curves were obtained from simulation results under heavy load conditions with an x of.5 and with no line or load correction factors. The simulation results showed that under light load conditions the ripple signal levels increase in 5 4.57 5 45 75 5 5 65 Sub A Figure 5 Resonance curve for the ultimate configuration of the underground system.

.5.5.8.5 5 55 5 55 5.5.5.5.75.5 5 55 5 55 5 Sub C comparison to what is obtained under heavy load. The high frequency correction applied to aggregate loads tends to increase the signal levels whereas when applied to lines the signal levels decrease. As expected, the resonance frequencies did not change when these factors were applied to the resistive components of the models. Determining the combination of factors which produces the most accurate model requires further studies. The simulation results indicate that problems do not currently exist in either of the two feeder systems which were modelled. The voltage levels were deemed acceptable based on the Meister Curve which is given in the CENELEC standard [] Measurements were carried out in the field to verify the accuracy of the models and to check the status of ripple signal problem. These measurements were carried out using PM POWERMonic monitors on a warm but not excessively hot summer day. Light load measurements were made at 4pm and heavy load measurements were made at 7pm. The results indicated an overall reduction in the signal levels both under light and heavy loads conditions when compared to what was observed in the previous study in relation to one of the feeders. The signal levels were found to be acceptable for both of the feeder systems investigated. There was generally a good correlation between the simulation results and the field results as can be seen in Table III. 5. CONCLUSIONS Sub D Figure 6 Resonance curves for the present configuration of the equally weighted system. In general it was shown that the modelling techniques adopted had a degree of accuracy which was acceptable for this study. This study showed that for the systems containing approximately equal amounts of overhead and underground cable, the resonance point was not at a Sub C Sub D Figure 7 Resonance curves for the ultimate configuration of the equally weighted system. problematic frequency and to the right of 5Hz. However, for a system where two thirds is underground, the resonance point was seen to be to the left of 5Hz. Therefore in a system where more than half and less than two thirds is underground, the resonance point may be at a problematic frequency. It was also observed that for an entirely underground system, the resonance point is to the right of 5Hz and not at a problematic frequency. This study has not taken into consideration the effect of power factor correction capacitors on the overall capacitance of the system. After examining the field and simulation results of the two kv feeder systems, it would appear that at present "Racing Clocks" is not a problem in these areas. This does not mean that the problem does not or cannot exist in other areas of a network. It is therefore recommended that during planning and development stages of new distribution networks, the ratio of underground and overhead cables be taken into consideration and the resonance frequency be given due attention. In terms of developing a more accurate model for simulating the "Racing Clock" problem, future research efforts are required. Further work could be Table III of Simulation Ripple Signal vs Field Ripple Signal of Ripple Signal in Simulation of Ripple Signal in Field % Difference Sub A.4.97-6.79 Sub B.54.85-5.4 Sub C.8.57 -.4 Sub D.8.98 6.

done to determine appropriate high frequency correction factors applicable to lines and loads. Further work also could be done on the modelling of loads to incorporate the effects of non-linear type loads. 6. REFERENCES. S. Perera, K. Nguyen, V. Gosbell, N. Browne, J. Stones, S. Elphick, Ripple Signal in Distribution Systems: A Case Study, IEEE th International Conference on Harmonics and Quality of Power, (To be presented). J Arillaga, BC Smith, NR Watson, AR Wood, Power System Harmonic Analysis, John Wiley, 997. EN56 Standard, "Voltage characteristics of electricity supplied by distribution systems", 996