Magnetic Inductive Flow Sensors induq. Series VMI

Similar documents
Magnetic Inductive Flow Sensors VMI Series

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Magnetic Inductive Flow Sensor induq

MAGNETIC INDUCTIVE FLOW SENSORS

Magnetic Inductive Flow Sensor

VVX. VVX20 QuickFasten. Technical datasheet BEST BEST. Flow measuring Vortex flow sensors. Your advantages

FMG90 Series Electromagnetic Flow Meter

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Electromagnetic flowmeter in all metal design Model MIM

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

INSERTION paddle wheel flowmeter for continuous flow measurement

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Positive Displacement Flow sensors

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

ph or ORP Transmitter

Digital flow transmitter for continuous flow measurement

Electromagnetic Flow Transmitter

Electromagnetic flowmeters and switches DWM 1000/2000

FMG70B Series Magnetic Inductive Flow Sensor

Conductivity Transmitter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

The transducer component converts the measured signal and displays the actual value.

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Digital batch controller

Technical Information Smartec CLD18

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Digital flowmeter for continuous flow measurement

Technical Information Smartec CLD18

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Condumax W CLS15 and CLS15D

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Inductive conductivity transmitter JUMO CTI-Junior

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Digital flowmeter for continuous flow measurement

OPTIFLUX 5000 Technical Datasheet

DUK. Compact Ultrasonic Flowmeter

Digital inductive conductivity transmitter

NGR. Guided Wave Radar Level Transmitter

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Technical specification FLUXUS F401 H2O

BATCHFLUX 5500 C Technical Datasheet

Magnetic Inductive Flowmeter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

OPTIFLUX 5000 Technical Datasheet

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

OPTIFLUX 1000 Technical Datasheet

2/2 way Proportional Valve (motordriven)

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Digital conductivity transmitter

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Universal process controller econtrol

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Screw-in resistance thermometers with terminal head Form B

Liquid Level Switches

Condumax CLS15 and CLS15D

Inductive angle sensor. 4-wire, analog output. Ri360P1-QR14-ELiU5X2-0,3-RS5. Rectangular, plastic Many mounting possibilities

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Technical Information Condumax CLS15D/CLS15

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Operating Instructions for Microwave Level Switch. Model: LNM

Electronic Pressure Switch Type MEP

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

FHKUK 30 John Guest 3/8 SCAN Arnite Part number: DATA SHEET

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Fluxi 2000/TZ. Turbine Gas Meter

Technical Information Smartec CLD18

Universal process controller econtrol

Protection Class (IEC 529)

LINEAR POTENTIOMETER. LZW Series. Key-Features:

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Universal process controller econtrol

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

KFS. Flap-type flow meter. Design and range of application

Level Sensors Reed Contact Chain

SONO 1500 CT Ultrasonic flow sensor

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Inductive Linear Position Sensor LI200P0-Q25LM0-HESG25X3-H1181

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Inductive Conductivity Meter ILM

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

FLOWave SAW-Flowmeter

FLOMID FX Electromagnetic Flowmeter

Transcription:

Magnetic Inductive Flow Sensors induq Series VMI

Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product line allows a unique and highly reliable measuring technique to be introduced into areas of process control previously considered not possible. The advantages of the induq will convince you: No moving parts No mechanical wear Free pipe cross section No additional pressure drop Insensitive with contaminated liquids Maintenance-free Quick response time (< 500 ms) Minor requirements to the inlet pipe Operational principle The fl ow sensor induq operates on the inductive principle: The measuring pipe is in a magnetic fi eld (B). If an electrically conductive medium with the measured fl ow (Q) passes through the pipe and thus right-angled to the magnetic fi eld, a voltage (U) will be induced into the medium which is proportional to the average fl ow velocity and picked up by the two electrodes. Changes of temperature, density, viscosity, concentration or electrical conductivity of the medium do not affect the output signal. Typical application areas induq can be used in areas where fl ow sensors with moving parts e. g. paddle wheel sensors, cannot be applied due to contaminated media. The sensor is intended for continously measuring of fl ow rates or for dosing / batching of electrically conductive liquids with a minimum conductivity of 50 μs/cm. induq is the ideal fl ow sensor for interference free operation combined with long-life cycle. Output signals The output signal is issued as a fl ow proportional frequency signal. Two options are available for output signals: Frequency output signal (standard) Analog and frequency output signal (option) Materials Electrodes Stainless steel 1.4571 Process connections Stainless steel 1.4571 Measuring pipe PEEK-GF30 Gasket EPDM Housing Aluminium casting induq is a registered trademark of SIKA Dr. Siebert & Kühn GmbH und Co. KG - 2 -

Technical data Type VMI 07 VMI 10 VMI 20 Flow range 1...20 l/min 2...40 l/min 10...200 l/min Accuracy ±2 % of reading ±2 % of reading ±2 % of reading Signal output starting from approx. 0.5 l/min approx. 1 l/min approx. 5 l/min Repeatability 1 % 1 % 1 % Medium / min. conductivity of medium Water and other conductive liquids / 50 μs/cm (lower conductivity affects the accuracy) Max. medium temperature 90 C Ambient temperature 5...70 C Storage and transport temperature -40...90 C Nominal pressure PN16 Diameter DN 7 DN 10 DN 20 Process connection ½ BSP male thread ½ BSP male thread 1 BSP male thread Flow indication LED green, fl ow proportional blinking Output signals Frequency output signal Pulse rate** Resolution Signal shape Standard: 855 pulses/l, Optional: 1...2 000 pulses/l Standard: 1.2 ml/pulse, Optional: 1 000...0.5 ml/pulse Square wave signal NPN, internal pull-up resistor 2 k pulse duty ratio 50:50 Standard: 855 pulses/l, Optional: 1...1 000 pulses/l Standard: 1.2 ml/pulse, Optional: 1 000...1 ml/pulse Square wave signal NPN, internal pull-up resistor 2 k pulse duty ratio 50:50 Standard: 200 pulses/l, Optional: 1...200 pulses/l Standard: 5 ml/pulse, Optional: 1 000...5 ml/pulse Square wave signal NPN, internal pull-up resistor 2 k pulse duty ratio 50:50 Signal current Max. 20 ma, current limited Max. 20 ma, current limited Max. 20 ma, current limited Analog output signal (optional) 4...20 ma proportional to 0...20 l/min* 4...20 ma proportional to 0...40 l/min* 4...20 ma proportional to 0...200 l/min* Current limitation approx. 26 ma approx. 26 ma approx. 26 ma Max. burden 250 to GND 250 to GND 250 to GND General data Response time < 500 ms Electrical connection Plug connector M12x1 Power supply 24 VDC ±10 % Current consumption Max. 80 ma Electr. protection measures Short-circuit proof (up to 30 V) and polarity protection (up to -30 V) Protection class IP 65 *others on request **optional output signal with lower frequency, designed specifi cally for connection to digital PLC input modules - 3 -

Order code Order number Diameter DN 7 DN 10 DN 20 Output signal Frequency output signal Analog and frequency output signal VMI0720K7 VMI1040K7 VMI2011K7 2PT0 BPT0 A3 A3 A5 Accessory Accessory part Length Order code Connection cable with 4 pin cable socket M12x1, angle type molded lead, sheathing material PUR, screened, (Tmax = 80 C) UL-approval 3 m 5 m 10 m XVT 2053 XVT 2009 XVT 2070-4 -

Dimensions VMI 07 and VMI 10 Pressure drop VMI 07 and VMI 10 VMI 07 VMI 10 Dimensions VMI 20 Pressure drop VMI 20 VMI 20-5 -

Our Production and Sales Range Flow Sensors without moving Parts Turbine Flow Sensors Flow Switches Pressure Gauges and Pressure Sensors Industrial Thermometers Electronic Digital Thermometers, Dial Thermometers Measuring Instruments Temperature Sensors Your competent partner for measurement and control Calibrators, DKD-Laboratory...measurement...control...calibration Phone: 0700 CALL SIKA Phone: +49 5605 803-0 Fax: +49 5605 803-54 E-Mail: info@sika.net Internet: http://www.sika.net Struthweg 7-9, 34260 Kaufungen P. O. Box 1113, 34254 Kaufungen Germany DB_VMI_e 08/2011