Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules

Similar documents
Voltage-dependent quantum efficiency measurements of amorphous silicon multijunction mini-modules

Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature

Validation of spectral response polychromatic method measurement of full size photovoltaic modules using outdoor measured data

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

Accessing the performance. light processing projector

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

Determining spectral response of a photovoltaic device using polychromatic filters

Advantages in using LEDS as the main light source in solar simulators for measuring PV device characteristics

Proprietary Calibration Certificate

CHARACTERIZATION OF CPV CELLS ON A HIGH INTENSITY SOLAR SIMULATOR: A DETAILED UNCERTAINTY ANALYSIS

Development of a solar cell spectral response mapping system using multi-lbic excitation

Designing practical on-site. on-site calibration protocols for acoustic systems: key elements and pitfalls.

Performance of high-eciency photovoltaic systems in a maritime climate

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

Project full title: "Nanowire based Tandem Solar Cells" Project acronym: Nano-Tandem Grant agreement no: Deliverable D6.1:

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

1) Solar simulator with I-V measurement setup and software

Large Area Steady State Solar Simulator - Apollo

Bifacial Solar Cells under Single- and Double-Sided Illumination: Effect of Non-Linearity in Short-Circuit Current

Primary Calibration of Solar Photovoltaic Cells At the National Metrology Centre of Singapore

APPLICATION NOTE. The Challenge of Making Reliable Solar Cell Measurements. Technology and Applications Center Newport Corporation

Actual PV module performance including spectral losses in the UK

SHORT TECHNICAL DESCRIPTION

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

IEC : Measurement of current-voltage characteristics of bifacial photovoltaic devices

SOLARONIX. Solixon A-1525-V

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

Solar Cell Parameters and Equivalent Circuit

INDOOR AND OUTDOOR CHARACTERIZAITION OF a-si:h P-I-N MODULES

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

Power Rating of Multi-junction Solar Cells: Focus Thin Film

Review and Adjudication Information. Group: DSSC/OPV Task Force Taiwan PVTC Chapter Date: TBD Aug 6, 2015 Time & Time zone: TBD

Spectrally Selective Sensors for PV System Performance Monitoring

Photovoltaic testing for R&D, DV, and manufacturing

Introduction to Photovoltaics

Actual issues on power measurement of photovoltaic modules

Task Force Review Committee Adjudication Group: Organic and Dye Sensitized Solar Cell Taiwan PV TC Chapter

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources

CES Solar Cell Testing Centre, Pilot Plant Development and Training Institute (PDTI), Thailand 3

Optimising Layer Thickness of Multi-Junction Silicon Devices for Energy Production in a Maritime Climate

I-V, C-V and AC Impedance Techniques and Characterizations of Photovoltaic Cells

Key Questions ECE 340 Lecture 28 : Photodiodes

I-V, C-V and Impedance Characterization of Photovoltaic Cells using Solartron Instrumentation

Background Statement for SEMI Draft Document 5979 NEW STANDARD: SPECIFICATION OF INDOOR LIGHTING SIMULATOR REQUIREMENTS FOR EMERGING PHOTOVOLTAIC

Design, construction and characterization of a steady state solar simulator

OPTIMIZING CPV SYSTEMS FOR THERMAL AND SPECTRAL TOLERANCE

14.2 Photodiodes 411

10/14/2009. Semiconductor basics pn junction Solar cell operation Design of silicon solar cell

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

idonus UV-LED exposure system for photolithography

Characterisation of Photovoltaic Materials and Cells

Cutting tools in finishing operations for CNC rapid manufacturing processes: simulation studies

Updating to remain the same: Habitual new media [Book Review]

Accurate determination of distribution network losses

Performance Loss of PV systems. Giorgio Belluardo

Reconfigurable antenna using photoconducting switches

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

Volume 11 - Number 19 - May 2015 (66-71) Practical Identification of Photovoltaic Module Parameters

Disclosure to Promote the Right To Information

Stitched transmission lines for wearable RF devices

Optically reconfigurable balanced dipole antenna

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

Electrical Characterization

Validation Of The New Automatic System For AC Voltage Comparisons. Umberto Pogliano, Gian Carlo Bosco and Marco Lanzillotti

Understanding Potential Induced Degradation for LG NeON Model

CHAPTER-2 Photo Voltaic System - An Overview

Design and operation influences regarding rise and fall time of a photoconductive microwave switch

ECE2019 Sensors, Circuits, and Systems A2015. Lab #1: Energy, Power, Voltage, Current

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

The Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

Measurement of Component Cell Current-Voltage Characteristics in a Tandem- Junction Two-Terminal Solar Cell

Failure modes and effects analysis through knowledge modelling

SILICon IrrADIAnCe SenSor

An acoustic emission slope displacement rate sensor: Comparisons with established instrumentation

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Laboratory 2: PV Module Current-Voltage Measurements

Chapter 1 Introduction

Oriel Sol3A Class AAA Solar Simulators

Simple method for I-V characterization curve for low power solar cell using arduino nano

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

CC1-15: I-V Curve Data Acquisition System Description and features

Wideband blade monopole antenna with sleeved coaxial feed

Solar Cell I-V Characteristics

Calibration of a High Dynamic Range, Low Light Level Visible Source

Characterization and Analysis of Photovoltaic Modules and the Solar Resource Based on In-Situ Measurements in Southern Norway Georgi Hristov Yordanov

Advancements in solar simulators for Terrestrial solar cells at high concentration (500 to 5000 Suns) levels

Performance and Loss Analyses of High-Efficiency CBD-ZnS/Cu(In 1-x Ga x )Se 2 Thin-Film Solar Cells

The European Commission s science and knowledge service

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Characterisation of Photovoltaic Materials and Cells

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Quality Assurance in Solar with the use of I-V Curves

LINEARPYROMETER LP4. Technical Documentation KE November TN

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Transcription:

Loughborough University Institutional Repository Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation: MIHAYLOV, B.V.... et al, 2013. Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules. IN: Hutchins, M., Cole, A. and Watson, T. (eds.). Conference Proceedings C95: 9th Photovoltaic Science, Applications and Technology Conference, PVSAT-9, Swansea University,Swansea, Wales, 10th-12th April. Abingdon : Solar Energy Society, pp.179-182. Additional Information: This is a conference paper. Metadata Record: https://dspace.lboro.ac.uk/2134/15847 Version: Accepted for publication Publisher: c Solar Energy Society and PV-Net UK Rights: This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/ Please cite the published version.

Review of Uncertainty Sources in Indoor PV Calibration of c-si and Thin Film Single-Junction and Multi-Junction Cells and Modules B. Mihaylov*, M. Bliss, T.R. Betts, R. Gottschalg Centre for Renewable Energy Systems Technology, School of Electronic, Electrical and Systems Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK *Tel.: +44 1509 635342, Email: B.V.Mihaylov@lboro.ac.uk Abstract The calibration of PV devices requires an uncertainty analysis. However, the benefits of such analysis are not limited to calibration procedures. It can be useful for all PV device measurements since it increases the validity of the results. The sources of uncertainty in indoor PV device calibration are outlined. The uncertainties are discussed for different measurement setups and technologies. Indoor secondary calibration uncertainty in P max can range from less than 1.5% for c-si cells to more than 10% for large TF modules. The paper highlights the importance of understanding the uncertainty sources and conducting specific uncertainty calculations for a given measurement setup. The implications for research laboratories are that excessively large uncertainty in measurements can make comparison between results misleading and the conclusions questionable. 1 Introduction Every measurement is an estimation of the true value of the measurand. The uncertainty associated with measurements is an indication of the quality of a test method and its results. It is fundamentally important to researchers and their publications and it is essential to laboratories and their stakeholders. Other indicators such as repeatability and reproducibility give confidence in the results, but do not necessarily imply accuracy due to possible systematic effects. This is applicable to all PV devices performance indicators such as I sc, P max, efficiency and Fill Factor. A comparison between laboratories or even different sets of measurements is only meaningful when accompanied with a robust uncertainty analysis. The key difference between calibration and measurement is the accompanying traceability to SI units with the associated uncertainty. Even though uncertainty analysis is not a requirement for most measurements, it can improve the test method and the validity of the results. Based on calibration laboratories uncertainty analysis the general sources of uncertainty are outlined. These are the same for all solar simulator I-V measurements, but the relative contribution of each is setup specific. Consideration of these factors can help minimise both the random and systematic errors and thus improve routine I-V measurements in research laboratories. In this paper a general overview of the uncertainty sources in indoor I-V measurements is presented as well as detailed examples that can affect the measurement results and lead to wrong conclusions. 2 Estimation and calculation of measurement uncertainty The ISO Guide to the expression of uncertainty in measurement [1] prescribes a framework for estimating uncertainty and a method for combining the contributions into an overall uncertainty. In summary, it involves assigning different probability density functions and range of values to all the contributing influences and approximating them to equivalent Gaussian distributions. Based on a Taylor approximation of the model equations these are combined into a single output Gaussian distribution as shown in Figure 1 below. The standard deviation of that distribution is the uncertainty of the measurement. For more complicated, non-linear and correlated contributors a Monte Carlo method can be used [2]. Figure 1 Propagation of distributions of input qualities based on [2]. 3 Sources of uncertainty in I-V measurements and calibration The procedure for I-V measurements under simulated sunlight is detailed in IEC 60904-1[3]. Secondary reference cells are mostly calibrated against primary reference cells using the same method but with more stringent requirements in order to minimise uncertainty. The method uses a solar simulator as the light source and a Ref- for PVSAT-9, Swansea

erence Cell (RC) to adjust the irradiance level by matching the measured I sc with the calibrated value. Relative spectral response measurements of the RC and Device-under-test (DUT) are required for the mismatch factor correction. A range of solar simulators and data acquisition systems are used in different laboratories. Usually continuous solar simulators are used for cells and mini-modules and large area flash solar simulators are used for large modules. The Differential Spectral Responsivity [4] calibration method involves measuring the relative spectral response of the DUT for the whole wavelength range and the absolute spectral response for specific wavelengths. The result is then scaled and integrated and the I sc calculated for a reference spectrum. This method has similar uncertainty sources to External Quantum Efficiency (EQE) measurement systems and is not in the scope of this paper. A generalised list of uncertainty sources for the solar simulator method is outlined in Table 1. A detailed description of these sources along with the uncertainty calculations can be found in [5] and [6]. The uncertainty values cannot be read across since they are setup specific. Uncertainty sources in the Standard Test Conditions (STC) in Irradiance intensity Reference cell calibration uncertainty Reference cell drift Biasing of the reference cell near I sc Irradiance non-uniformity at the target Orientation of Device-under-test and RC Position of Device-under-test and RC in Irradiance spectrum Mismatch factor (spectral response + irradiance spectral distribution) Filter deterioration and lamp aging in Junction temperature Sensor calibration uncertainty Measurement resolution Distance between the sensor and junction Temperature non-uniformity Temperature drift during measurement Uncertainty sources in the Data acquisition (DAQ) DMM/DAQ offset and range Series resistance due to connectors and packaging Room temperature effect on the measuring equipment Shunt resistors calibration and temperature effect Parameter extraction uncertainty Uncertainty sources in measuring the Area Area definition Light piping/total Internal Reflection Measurement resolution Edge interpretation Table 1 Source of uncertainty in indoor solar simulator calibration. The relative contribution of each of these depends on the specific setup and DUT. For example, the irradiance distribution of a continuous simulator is easier to determine with lower uncertainty than that of a pulsed simulator and thus the mismatch factor uncertainty is lower. Furthermore, large area simulators have the reference cell next to the test sample. Continuous simulators have mostly the reference in place of the test sample (irradiance monitor is used during the changeover between the RC and DUT). As a result contributions due to the relative position and orientation in combination with the higher inhomogeneity increase the measurement uncertainty when large area simulators are used. This is one of the reasons why module measurements generally have a larger associated uncertainty than cells. The second is that calculating the mismatch factor for modules is more difficult since most laboratories are not capable of measuring the spectral response of specific modules under test with low uncertainty. The overall uncertainty for indoor secondary calibration, i.e. using a primary reference cell as the working standard, varies between 1.5% in P max for cells and 4% for large modules for c-si and other stable technologies [5,6]. The overall uncertainty is higher for thin film, dye-sensitized and organic technologies. The reasons for the higher uncertainties are mainly due to the nonuniformity of the device during manufacturing and due to some of the challenges in characterising these devices [7-9]. These include: sweep effects with pulsed simulators, metastability of the devices, preconditioning effects, current limiting with multi-junction devices, etc. The measurement artefacts may vary, but the most significant change in the uncertainty for all is due to the mismatch factor correction. This is because reference cells with a matching spectral response are not available due to stability issues, thus filtered c-si cells are used instead. In the regions where there is no overlap between the response of the device-under-test and the filtered reference cell the mismatch factor uncertainty is excessively high [10]. With multi-junction devices the difference between the AM1.5G [11] and the irradiance spectral distribution forces one of the junctions to be current limiting. A more involved procedure using a multi-source solar simulator is required as for PVSAT-9, Swansea

well as a well-matched reference cell for each junction [12]. Figure 2 below shows the relative contribution of the sources of uncertainty in c-si devices. The major sources are the Mismatch factor, the non-uniformity and the uncertainty of the calibration of the primary reference cell. However this is only the case if all other source are minimised due to a careful design of the measuring setup. Figure 2 Relative contribution of the uncertainty sources to the overall uncertainty in Isc of c-si cells a) at ESTI [5]; b) at NREL [6]. 4 Uncertainty sources implications in routine Solar Simulator measurements. 4.1 Temperature control I-V measurements are particularly sensitive to the change in junction temperature. Not all laboratories have custom designed measurement chucks for temperature measurement and control (Figure 3). Thin film devices with contacts at the back, e.g. CdTe cells, are particularly difficult to measure while the temperature of the junction is controlled. Measuring the temperature at the back of the photovoltaic devices is essential to validate the test results. This can be done with a PT100 during a quick I-V measurement indicating if the results should be rejected. A good thermal contact between the sensor and the test device is essential. The device should be stabilised at 25 C prior to and during any measurements. 4.2 Irradiance inhomogeneity, relative position and orientation of the DUT and RC. Low-cost solar simulators have poor light intensity homogeneity at the target plane and often the non-uniformity is not measured. It is falsely assumed that this is equal to the classification of the simulator. Typically lamps are not properly adjusted after installation introducing significant systematic effects into the measurements. The significance and the effect of this depend on the size of the sample and the relative position and orientation of the test device and the working reference cell or calibrated photodiode. Irradiance inhomogeneity is one of the dominant uncertainty sources and since the current is proportional to the irradiance level, a 5% inhomogeneity can introduce an excessively large systematic error. Measuring the inhomogeneity or at least comparing the I sc of a reference cell or calibrated diode at different positions can help estimate the systematic error due to the inhomogeneity. 4.3 Irradiance spectral distribution and spectral response of the DUT and RC Some laboratories cannot perform mismatch factor correction due to the difficulty of measuring the EQE of the device and the irradiance distribution of the light source. This is particularly difficult for large devices and pulsed solar simulators. The uncertainty sources of measuring the irradiance spectrum and lamp aging effects are discussed in [13]. Even though the irradiance spectral distribution is not known, reference cells are still used for setting up the irradiance level of the simulator. It is important to consider that a significant systematic error is possible due to the poor match of low-cost simulators to AM1.5G and between the spectral response of the device and the RC. For example, a CdTe device with a higher spectral response at the peaks of unfiltered Xenon source will seem more efficient during measurements but can be less efficient under AM1.5G. Figure 3 Temperature controlled, vacuum chuck for c-si solar cells. Figure 4 Xenon irradiance distribution and SR of Si reference cell and CdTe devices. for PVSAT-9, Swansea

As seen in Figure 4 under AM1.5G there is a dip at around 825nm instead of a peak as under Xenon illumination. This coincides with the relatively large difference in spectral response of the two CdTe devices. Considerations for organic cells are described in [9]. 4.4 Series resistance The series resistance introduced when connecting the test sample can greatly affect the Fill Factor results and it should be done with a 4-wire Kelvin connection. A number of measurements should be made reconnecting the same sample to estimate the random error. If the standard deviation of the results is high a better connection scheme is required. 4.5 Data acquisition system range Low irradiance level measurements can be misleading on one hand due to the non-linearity of the device and on the other due to using the same shunt resistor for measuring the short circuit current. This will change the voltage measuring range of the data acquisition system introducing high uncertainty due to the resolution and offset of the measuring equipment. This can be avoided by selecting an appropriate shunt resistor or selecting a lower measurement range. 4.6 Area calculation The definition of the area can vary at different institutions for different technologies. Therefore It should be explicitly stated how the area was measured. The uncertainty in the area calculation is subjected to the resolution of the equipment used and the edge interpretation by the operator. For small samples this can have an excessively large effect on the efficiency calculation. Depending on the device, total internal reflection within the encapsulation can increase the effective device area due to increased light collection. The effect can be minimised or even eliminated by using a fixed aperture mask with bevelled edges. 5 Conclusions There are numerous sources of uncertainty in secondary reference cell calibration. The careful consideration of these sources in any solar simulator measurement setup can minimise both random and systematic errors and increase the validity of the results. The paper summarises the general sources of uncertainty and details the implications of these on solar simulator measurements in research laboratories. The key sources to consider are the light inhomogeneity at the target plane and the relative position of the device-under-test and reference cell, the mismatch factor and temperature monitoring and control during the measurement. Finally care should be taken to minimise the series resistance of the connection and to calculate and report the area correctly. Acknowledgements This work has been supported in part by the PV-SuperGen project Supersolar (contract no: EP/J017361/1) funded by the Research Councils UK s (RCUK) Energy Programme. References [1] JCGM 100: "Evaluation of measurement data - Guide to the expression of uncertainty in measurement." 2008. [2] JCGM 101: Supplement 1, 2008. [3] IEC 60904-1: "Measurement of photovoltaic current-voltage characteristics", 2006. [4] J. Metzdorf, "Calibration of solar cells. 1: The differential spectral responsivity method," Appl. Opt., vol. 26, pp. 1701-1708, May 1, 1987. [5] H.Müllejans et al, "Analysis and mitigation of measurement uncertainties in the traceability chain for the calibration of photovoltaic devices," Meas. Sci. and Tech., vol. 20, 2009. [6] K. Emery, "Uncertainty analysis of certified photovoltaic measurements at the National Renewable Energy Laboratory," NREL/TP-520-45299, 2009. [7] Y. Hishikawa, "Traceable performance characterization of state-of-the-art PV devices," in 27 th EUPVSEC, Frankfurt, 2012. [8] W. Herrmann et al, "PV module output power characterisation in test laboratories and in the PV industry - results of the european PER- FORMANCE project," in 25 th EUPVSEC, Valencia, 2010. [9] V. Shrotriya et al, "Accurate Measurement and Characterization of Organic Solar Cells," Adv. Funct. Mater., vol.16, pp.2016-2023, 2006. [10] J. Hohl-Ebinger and W. Warta, "Uncertainty of the spectral mismatch correction factor in STC measurements on photovoltaic devices," Prog PV: Res Appl, vol. 19, pp. 573-579, 2011. [11] ASTM Standard G173: "Standard Tables for Reference Solar Spectral Irradiances..." 2003. [12] K. Emery et al, "A comparison of the errors in determining the conversion efficiency of multijunction solar cells by various methods," Solar Cells, vol. 24, pp. 371-380, 0, 1988. [13] M. Bliss et al, "Spectral changes of solar simulator xenon flash bulbs over lifetime and its effects on measurement uncertainty," in PVSAT, Swansea, 2013. for PVSAT-9, Swansea