IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS. Web Cast May 17, 2007

Similar documents
IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS. Web Cast November 30, 2006

Instructions for the WG Chair The IEEE-SA strongly recommends that at each WG meeting the chair or a designee:

Instructions for the WG Chair The IEEE-SA strongly recommends that at each WG meeting the chair or a designee:

Instructions for the WG Chair The IEEE-SA strongly recommends that at each WG meeting the chair or a designee:

Ad Hoc Call Agenda. IEEE P802.3cb CU4HDD Task Force. Dan Smith, Chair Seagate Technology February 25, Page 1

IEEE Working Group on Broadband Wireless Access (BWA)

IEEE 1722a/ Weekly Call. Dave Olsen

Stray Voltage and Swimming Pools

Electrical Interface Ad-hoc Meeting

AGENDA AND GENERAL INFORMATION IEEE P802.3CK GB/S, 200 GB/S, AND 400 GB/S ELECTRICAL INTERFACES TASK FORCE

INSULATED CONDUCTORS COMMITTEE

Standardized Measurements for Elevated NEV and Energized Object Concerns Doug Dorr, Charles Perry, Mark McGranaghan Arindam Maitra, Wes Sunderman

Contact Voltage Detection

IEEE Session #14 Opening Plenary Presentation

EPRI Contact Voltage R&D Program Update Doug Dorr EPRI

Webinar: An Effective Arc Flash Safety Program

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

Boat Dock Exposure Voltage Mitigation

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Offshore production installations Basic surface process safety systems

IEEE Broadband Wireless Access Working Group < Proposed PAR to convert P802.16d from Amendment to Revision

Test 1: What is the effect on cattle drinking water from an insulated water trough if an electric fence is within inches of the water tank?

Network Management Study Group Closing Plenary Report

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES

ECE 528 Understanding Power Quality

Title: LE Task Group Report - Session #45

Revision of C Guide for Application of Monitoring Equipment to Liquid Immersed Transformers and Components. Mike Spurlock Chairman

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

Grounding for Power Quality

Selection of PPE Practical experience of different arc assessment methods and their comparison

IEEE Broadband Wireless Access Working Group <

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Prepared by Mick Maytum

INTERNATIONAL STANDARD

Technique for Accurate Voltage Measurement of Energized Street Level Objects

INTERNATIONAL STANDARD

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Arc Flash Analysis and Documentation SOP

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

Options to Improve the MEN System into the 21 st Century

Earthing of Electrical Devices and Safety

TS RES - OUTSTANDING ISSUES

Industrial and Commercial Power Systems Topic 7 EARTHING

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

SWITCHING SAFETY & RELIABILITY CONFERENCE

IEEE Broadband Wireless Access Working Group < Working Group Review of Working Document IEEE 802.

Recommended Practice for Flexible Pipe

Guide for Conducting a Stray Voltage Evaluation Under the MPSC Stray Voltage Rule 1

PC IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases

The Standards Development Process. Substations Committee Erin Spiewak IEEE SA May 20, 2012

IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program. Venue: Operator. Speaker Travel: Stantec

... avoid using constructionstyle generators that have master GFCIs.

Light Pole Safety Testing Mark Voigtsberger VP of Operations Power Quality Testing

Exhibit DD Specific Standards for Transmission Lines. Boardman to Hemingway Transmission Line Project

Summary of the Impacts of Grounding on System Protection

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

The CCSA IPR Policy. China Communications Standards Association. October 31, 2007

The Confusion Surrounding Stray Voltage

IEEE Major Revision of Interconnection Standard

A Mixed OFDM Downlink and Single Carrier Uplink for the 2-11 GHz Licensed Bands

Upgrading Your Electrical Distribution System To Resistance Grounding

AES standard for acoustics Digital interface for microphones. Preview only

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

AC Voltage- Pipeline Safety and Corrosion MEA 2015

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

INTERNATIONAL STANDARD

I. Introduction to Animal Sensitivity and Response

ISO INTERNATIONAL STANDARD

7P Series - Surge Protection Device (SPD) Features 7P P P

In late 2011, The International Standards

Harmonic Distortion Levels Measured at The Enmax Substations

Doing It Right. Phasor Labs. March voice fax

IEEE 1547: Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces

SE-502 MANUAL GROUND-FAULT GROUND-CONTINUITY DETECTOR

IEEE C802.16h-07/013. IEEE Broadband Wireless Access Working Group <

Los A LA-UR Los Alamos National Laboratory Los Alamos, New Mexico 87545

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Floating Circuits - Protection against electric shock

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

CONSOLIDATED VERSION IEC TR Code of practice for hearing-loop systems (HLS) colour inside. Edition

Final draft ETSI EN V2.1.1( )

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Protecting Large Machines for Arcing Faults

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Progressing Cavity Pump Systems for Artificial Lift Surface-drive Systems

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

INTERNATIONAL STANDARD

Electrical Severity Measurement Tool Revision 4

TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) IPR AND STANDARDIZATION

IEEE le-04/04. IEEE Broadband Wireless Access Working Group <

Preface...x Chapter 1 Electrical Fundamentals

Underground System Design TADP 547

DESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN

CONTINUING EDUC ATION

Power Over Ethernet (PoE) Part 1 What is it?, How is it used?, and Lightning Field Failure Analysis

Grounding System Theory and Practice

Wisconsin Contractors Institute Continuing Education

Transcription:

IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS Web Cast May 17, 2007 CHAIR CHUCK DENARDO (414) 221-3073 (chuck.denardo@we-energies.com) VICE CHAIR JIM BOUFORD (508) 421-7648 (james.bouford@us.ngrid.com) SECRETARY RUSS EHRLICH (302) 283-6097 (russ.ehrlich@pepcoholdings.com) Working Group Web Site: (http://grouper.ieee.org/groups/td/dist/stray/)

IEEE-SA Standards Board Bylaws on Patents in Standards 6. Patents IEEE standards may include the known use of essential patents and patent applications provided the IEEE receives assurance from the patent holder or applicant with respect to patents whose infringement is, or in the case of patent applications, potential future infringement the applicant asserts will be, unavoidable in a compliant implementation of either mandatory or optional portions of the standard [essential patents]. This assurance shall be provided without coercion. The patent holder or applicant should provide this assurance as soon as reasonably feasible in the standards development process. This assurance shall be provided no later than the approval of the standard (or reaffirmation when a patent or patent application becomes known after initial approval of the standard). This assurance shall be either: a) A general disclaimer to the effect that the patentee will not enforce any of its present or future patent(s) whose use would be required to implement either mandatory or optional portions of the proposed IEEE standard against any person or entity complying with the standard; or b) A statement that a license for such implementation will be made available without compensation or under reasonable rates, with reasonable terms and conditions that are demonstrably free of any unfair discrimination. This assurance is irrevocable once submitted and accepted and shall apply, at a minimum, from the date of the standard s approval to the date of the standard s withdrawal.

Inappropriate Topics for IEEE WG Meetings Don t discuss the validity/essentiality of patents/patent claims Don t discuss the cost of specific patent use Don t discuss licensing terms or conditions Don t discuss product pricing, territorial restrictions, or market share Don t discuss ongoing litigation or threatened litigation Don t be silent if inappropriate topics are discussed do formally object. If you have questions, contact the IEEE-SA Standards Board Patent Committee Administrator at patcom@ieee.org or visit http://standards.ieee.org/board/pat/index.html This slide set is available at http://standards.ieee.org/board/pat/pat-slideset.ppt

WE ENERGIES - Host of Today s Web Meeting Serves about 2.3 million people in a service area of 12,600 sq. miles in Wisconsin and Michigan s Upper Peninsula Electric and gas utility 1,026,000 electric service customers Service area of 12,600 square miles Generating capability of 5900 MW Peak demand of 6,400 MW Urban & rural service areas Voltages from 4kV through 34.5kV 28,000 miles of primary power lines 30,000 miles of secondary/service power lines Number of employees: 5,800

This Web cast will have two parts: Shashi Patel (NEETRAC): Swimming Pool Equipotential Bonding - Proposed Changes to NEC 680.26 Chuck DeNardo: Trial Use Guide - Outline Draft ***Please mute your phones when not speaking.***

NEETRAC Presentation

OUTLINE DRAFT Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations From the Standards Board Operations Manual: Guides: documents in which alternative approaches to good practice are suggested but no clear-cut recommendations are made. Trial-Use documents: publications that are effective for not more than two years.

Voltages at Publicly and Privately Accessible Locations (a.k.a. Stray Voltage, Contact Voltage, Neutral-to-Earth Voltage, Urban Stray Voltage, Metallic Object to Earth Voltage, Animal Contact Voltage, Tingle Voltage, etc.) Technically Complicated Publicly Misunderstood Controversial & Emotional Litigious

P1695 PURPOSE There is presently no industry wide guide or standard that describes the variety of publicly and privately accessible voltages resulting from the delivery and use of electrical energy. This guide will help dispel misinformation surrounding this topic and enhance public safety.

P1695 SCOPE This guide addresses the normal and abnormal voltages that exist at publicly and privately accessible locations as a result of the delivery and use of electrical energy (often referred to as stray voltage). It focuses primarily on the presence of power frequency related voltages, and discusses definitions, causes, impacts, testing techniques, mitigation strategies, and hazard levels.

A Few Important Points (Based On Working Group Discussions To Date) There are publicly accessible voltages related to normal system operation that must be present, and there are publicly accessible voltages related to abnormal system operation that should not be present. These are two very different things that should be defined and discussed separately. Human and animal exposure to conducted current is well understood. We want the reader to learn something about the science behind existing exposure standards; where to find, and how to apply these standards. This is necessary so that informed decisions can be made regarding the degree of hazard that exists and what, if anything, should be done about it. We want to provide the reader with the knowledge and tools necessary to make meaningful measurements. This will enable identification of sources and, if necessary, aid in selection of appropriate mitigation alternatives.

Outline Draft (05/17/2007) IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 1. Overview (Required) 2. Normative References (Required) 3. Definitions/Acronyms/Abbreviations (Required) 4. General Discussion 5. Human and Animal Sensitivity to Conducted Current 5.1 Sensitivity in terms of voltage exposure 6. Publicly and Privately Accessible Voltages Related to Abnormal System Operation ( Contact Voltage ) 6.1 General 6.2 Contact Voltage Sources 6.3 Contact Voltage Investigation 6.3.1 Test and Measurement Equipment 6.3.2 Investigation Protocol 6.4 Contact Voltage Mitigation 6.5 Case Studies

7. Publicly and Privately Accessible Voltages Related to Normal System Operation ( ( Stray Voltage ) 7.1 General 7.2 Stray Voltage Sources 7.2.1 Return Current 7.2.2 Induced Current 7.3 Stray Voltage Investigation 7.3.1 Test and Measurement Equipment 7.3.2 Investigation Protocol 7.3.2.1 Confined Livestock 7.3.2.2 Swimming Pools 7.3.3.3 Outdoor and Basement Showers 7.4 Stray Voltage Mitigation 7.5 Case Studies 8. Previously Established Voltage Exposure Standards 9. Existing Regulation Annex A: Flow Charts Annex B: Sample Data Collection Forms Annex C:???

Outline Draft (05/17/2007) IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 1. Overview (Required) Scope and Purpose of the Guide 2. Normative References (Required) Documents necessary to understand and use the Guide (e.g. USDA Handbook 696) 3. Definitions/Acronyms/Abbreviations (Required) 4. General Discussion Reasons for confusion surrounding the issue, some amount of measurable voltage will always be present, contact voltage v. stray voltage, sources are both primary (utility) and secondary (customer), grounded v. ungrounded systems, etc.

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 5. Human and Animal Sensitivity to Conducted Current Research summary, nerve stimulation model discussion, factors affecting sensitivity, sensitivity versus frequency and/or duration of exposure, people versus animals, etc. 5.1 Sensitivity in terms of voltage exposure Characteristics and importance of the exposure circuit (e.g. source impedance, contact impedance, body impedance, etc.), why it s difficult to create a voltage exposure standard, etc.

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 6. Publicly and Privately Accessible Voltages Related to Abnormal System Operation ( Contact Voltage ) 6.1 General Potentially hazardous nature of contact voltage, degree of hazard dependent on exposure circuit not measurement circuit, number of incidents (i.e. putting the issue in perspective), existing proactive programs, etc. 6.2 Contact Voltage Sources Fault current (i.e. shorts and opens), fault current availability, insulation degradation, wiring errors, broken conductors, voltages induced during fault conditions, etc.

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 6.3 Contact Voltage Investigation 6.3.1 Test and Measurement Equipment Electric field detection (e.g. proximity detectors, mobile platforms, etc.), multi-meters, load resistors, safety gear, etc. 6.3.2 Investigation Protocol Safety precautions, understanding remote earth, measurement location, measurement technique, data analysis, false positives, etc. 6.4 Contact Voltage Mitigation Insulation failure, wiring errors, open conductors, etc. 6.5 Case Studies Street light, manhole, etc.

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 7. Publicly and Privately Accessible Voltages Related to Normal System Operation ( Stray Voltage ) 7.1 General Historically considered a nuisance voltage. Generally associated with animal exposures, swimming pool & shower shocks. Primary (utility) and secondary (customer) sources. Harmonics, transients, etc. 7.2 Stray Voltage Sources 7.2.1 Return Current Systems with a neutral conductor, systems without a neutral conductor, SWER, etc. 7.2.2 Induced Current Transmission Source, Primary Source, Secondary Source, etc.

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 7.3 Stray Voltage Investigation 7.3.1 Test and Measurement Equipment Recording devices, load boxes, copper plates, etc. 7.3.2 Investigation Protocol 7.3.2.1 Confined Livestock 7.3.2.2 Swimming Pools 7.3.3.3 Outdoor and Basement Showers 7.4 Stray Voltage Mitigation Bad neutral connections, undersized conductors, poor grounding, phase balance, system voltage, etc. 7.5 Case Studies

Outline Draft (05/17/2007) Continued IEEE Trial Use Guide for Assessing Voltages at Publicly and Privately Accessible Locations 8. Previously Established Voltage Exposure Standards IEEE, IEC, NEC, etc. 9. Existing Regulation Wisconsin, Idaho, Michigan, New York, etc. Annex A: Flow Charts Annex B: Sample Data Collection Forms Annex C:???

The Next Meeting of the Working Group on Voltages at Publicly and Privately Accessible Locations will be at the 2007 PES General Meeting in Tampa, Florida from 1:00 4:00 p.m on Monday June 25 th (Marriott Room 6). For Meeting and Room Reservations: (http://ewh.ieee.org/r3/floridawc/pesias/) Tentative Agenda: Electric Field Detection Power Survey Corporation Working Group Procedures Outline Draft

IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS Web Cast May 17, 2007 CHAIR CHUCK DENARDO (414) 221-3073 (chuck.denardo@we-energies.com) VICE CHAIR JIM BOUFORD (508) 421-7648 (james.bouford@us.ngrid.com) SECRETARY RUSS EHRLICH (302) 283-6097 (russ.ehrlich@pepcoholdings.com) Working Group Web Site: (http://grouper.ieee.org/groups/td/dist/stray/)