Lab 3: AC Low pass filters (version 1.3)

Similar documents
Lab 9: Operational amplifiers II (version 1.5)

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

ECE 2274 Lab 2 (Network Theorems)

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

PHASES IN A SERIES LRC CIRCUIT

Lab 10: Oscillators (version 1.1)

BME 3512 Bioelectronics Laboratory Two - Passive Filters

Experiment 8: An AC Circuit

Experiment 9 AC Circuits

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

AC Magnitude and Phase

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE

Experiment 1: Instrument Familiarization (8/28/06)

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Frequency Response and Filters

NI ELVIS II+ Tips and Tricks

EK307 Active Filters and Steady State Frequency Response

EE 210: CIRCUITS AND DEVICES

LRC Circuit PHYS 296 Your name Lab section

Lab: Operational Amplifiers

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

BME/ISE 3511 Laboratory One - Laboratory Equipment for Measurement. Introduction to biomedical electronic laboratory instrumentation and measurements.

PHY203: General Physics III Lab page 1 of 5 PCC-Cascade. Lab: AC Circuits

PHYS 3322 Modern Laboratory Methods I AC R, RC, and RL Circuits

AC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )

Lab #5 Steady State Power Analysis

ECE 201 LAB 8 TRANSFORMERS & SINUSOIDAL STEADY STATE ANALYSIS

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

Physics 310 Lab 2 Circuit Transients and Oscilloscopes

ECE 2274 Lab 1 (Intro)

ENG 100 Lab #2 Passive First-Order Filter Circuits

The Series RLC Circuit and Resonance

PHY 132 Summer 2000 LAB 9: LRC Circuit (Phases) 1

EE 2274 RC and Op Amp Circuit Completed Prior to Coming to Lab. Prelab Part I: RC Circuit

Experiment 1: Instrument Familiarization

Lab 9 - INTRODUCTION TO AC CURRENTS AND VOLTAGES

University of Pennsylvania Department of Electrical and Systems Engineering. ESE 206: Electrical Circuits and Systems II - Lab

PHYSICS 221 LAB #6: CAPACITORS AND AC CIRCUITS

ET1210: Module 5 Inductance and Resonance

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

OPERATIONAL AMPLIFIERS (OP-AMPS) II

Name: First-Order Response: RC Networks Objective: To gain experience with first-order response of RC circuits

Lab E5: Filters and Complex Impedance

INTRODUCTION TO AC FILTERS AND RESONANCE

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

Lab Session 4 Hardware

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

ECE 2201 PRELAB 6 BJT COMMON EMITTER (CE) AMPLIFIER

Lab 4: Analysis of the Stereo Amplifier

NI Elvis Virtual Instrumentation And Prototyping Board

Non-ideal Behavior of Electronic Components at High Frequencies and Associated Measurement Problems

Department of Electrical & Computer Engineering Technology. EET 3086C Circuit Analysis Laboratory Experiments. Masood Ejaz

Electronics and Instrumentation ENGR-4300 Spring 2004 Section Experiment 5 Introduction to AC Steady State

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

Lab 1: Basic RL and RC DC Circuits

Laboratory Exercise 6 THE OSCILLOSCOPE

LAB 8: Activity P52: LRC Circuit

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

SINUSOIDS February 4, ELEC-281 Network Theory II Wentworth Institute of Technology. Bradford Powers Ryan Ferguson Richard Lupa Benjamin Wolf

University of Pennsylvania Department of Electrical and Systems Engineering ESE319

LAB 1: Familiarity with Laboratory Equipment (_/10)

Theory: The idea of this oscillator comes from the idea of positive feedback, which is described by Figure 6.1. Figure 6.1: Positive Feedback

ECE212H1F University of Toronto 2017 EXPERIMENT #4 FIRST AND SECOND ORDER CIRCUITS ECE212H1F

Lab 13 AC Circuit Measurements

Pre-Lab. Introduction

EE-2302 Passive Filters and Frequency Response

Resonance in Circuits

Operational Amplifiers 2 Active Filters ReadMeFirst

Electric Circuit Fall 2017 Lab10. LABORATORY 10 RLC Circuits. Guide. Figure 1: Voltage and current in an AC circuit.

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

AC Measurements with the Agilent 54622D Oscilloscope

Experiment 2: Transients and Oscillations in RLC Circuits

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

E84 Lab 3: Transistor

Lab Exercise # 9 Operational Amplifier Circuits

RLC Frequency Response

Integrators, differentiators, and simple filters

UNIVERSITY OF CALIFORNIA, BERKELEY. EE40: Introduction to Microelectronic Circuits Lab 1. Introduction to Circuits and Instruments Guide

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

EE 1210 Op Amps, Gain, and Signal Integrity Laboratory Project 6

Study of Inductive and Capacitive Reactance and RLC Resonance

Instructions for the final examination:

Laboratory Project 1: AC Circuit Measurements and Simulation

EK307 Passive Filters and Steady State Frequency Response

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

Week 4: Experiment 24. Using Nodal or Mesh Analysis to Solve AC Circuits with an addition of Equivalent Impedance

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

Physics 364, Fall 2014, reading due your answers to by 11pm on Sunday

AC Circuits INTRODUCTION DISCUSSION OF PRINCIPLES. Resistance in an AC Circuit

Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor)

Series and Parallel Resonance

Exercise 1: Inductors

1.0 Introduction to VirtualBench

Lab 2: Capacitors. Integrator and Differentiator Circuits

Transcription:

Lab 3: AC Low pass filters (version 1.3) WARNING: Use electrical test equipment with care! Always double-check connections before applying power. Look for short circuits, which can quickly destroy expensive equipment. Partial list of equipment needed: Digital oscilloscope Function generator ELVIS board Scope probes Resistors: 200 Ω and 1 kω (not critical) Capacitor: 100 nf (not critical, substitute as needed) Inductor: 3.9 mh (not critical, substitute as needed) Introduction to the Elvis board The National Instruments Elvis board is a powerful platform for circuit development. One of its many functions is measurement of complex impedance, including the pure reactance of capacitors and inductors. Acquire a capacitor with a value around 100 nf and an inductor in the range of 3 5 mh. Turn on the main Elvis board power with the switch located behind it. Turn on the 2nd power switch at upper right. Insert the desired component (capacitor or inductor) in the DMM/Impedance analyzer using pins OUT+ and OUT. Start the NI ELVISmx Instrument Launcher program on the adjacent PC (found under the National Instruments menu). Select the DMM; an I/O device should be identified (this can take several seconds). Select the appropriate circuit diagram element for capacitor or inductor and push the run button to measure the capacitance or inductance. Record both values. Resistors are measured with the V Ω and COM connections located on the far left side of the Elvis board. Frequency response and complex impedance The following measurements will explore the frequency response of an R C and L R circuit. They will show the frequency dependent behavior of a circuit element (capacitor or inductor) and the importance of phase shift on AC signals. This behavior can be conveniently modeled using complex impedance. For example, assuming a steady state periodic input such as a sinusoidal wave Vosin(wt), the impedance of a capacitor (C) in the same circuit can be written: Z C = 1/jwC, where j = 1. You will be building a voltage divider network as in the previous experiments, but one of the resistors is replaced by a capacitor or inductor. First, test your scope probes on CH 1 and CH 2 to make sure they are operating properly. Consult the previous lab instructions if needed. Setup the function generator to produce

a 1 Volt p p sine wave at 1 khz. Note 1: The oscilloscope amplitude may differ from the function generator setting by a factor of 2. This is because the output impedance of the function generator is set to 50 Ω. Change it to high impedance (High Z) using the Utility menu. Using the same guidelines as in the previous experiments, build the following circuit on the breadboard using the resistor and capacitor measured above (nominally R = 200 Ω and C = 0.1 µf): Vin is supplied by the function generator and Vout is the voltage across the capacitor. Measure Vin on CH 1 of the scope. You can use a scope probe connected to R; clip the reference lead to ground. The less cluttered option is to use a BNC T connector to route the function generator signal directly to the CH 1 input (i.e. scope probe not needed) and to the circuit with a BNC/EZ hook cable. Connect a scope probe to CH 2 and clip it across C to measure Vout. Measurement of the signal waveforms Measure the amplitude and phase of Vout relative to the Vin as a function of frequency. The amplitude response is simply the ratio of peak to peak voltage for the two channels. A frequency range between 1 and 30 khz should provide enough data to map out the response, depending on the choice of R and C. The absolute frequency start and end points are not critical; take enough data (8 10 points is adequate, more is better) to show the drop off in signal with increasing frequency. Increase the frequency high enough to make Vout/Vin less than 0.1. The frequency dependent voltage amplitude change at Vout is a straightforward measurement, but determining the voltage phase difference is more challenging. You are displaying two waveforms and can use the adjustable cursors to measure the time delay between key points. This time delay can be directly converted to a phase difference because the period of the waveforms is known. In addition, many modern digital scopes can measure the phase difference directly, displaying the result in degrees of phase. This can be accessed in the measurement menu. If your scope has this capability, perform both measurements and confirm they agree.

Note 2: When measuring phase, it is critical to keep track of what is being measured relative to what. For example, the phase difference φ = 45 o could be interpreted as φ = +315 o depending on the perspective. Just as with voltage, phase is always a relative measurement. It has a point of reference and it must be correctly accounted for in your analysis. Note 3: The R C circuit is one of the most important concepts in electronic instrumentation. An experimentalist must be constantly aware of it because there is always stray capacitance present, i.e. unintentional capacitance that can affect the integrity of a measurement. The cutoff frequency of an R C circuit is defined as f c = w c /2π = 1/2πRC. The circuit shown above is a low pass filter because the output signal is reduced as the frequency increases in the neighborhood of f c. If the resistor and capacitor are exchanged, the circuit becomes a high pass filter. If you look at the input connection of any oscilloscope, the input impedance associated with it will be labeled. A typical scope may have a 1 MΩ input resistance in parallel with 20 pf of stray (unintentional but unavoidable) capacitance. This means the scope may act as a low pass filter with a cutoff frequency of around 8 khz. The cutoff can be increased to nearly 160 MHz by using a 50 Ω BNC terminator, which will be in parallel with the internal 1 MΩ resistance. This value is chosen because it is comparable with the characteristic impedance of coaxial cable. When a 50 Ω terminator is used, however, the measured voltage levels will drop accordingly. Low pass filter with inductor The low pass filter can also be implemented with an inductor and resistor arranged as follows: Build this circuit with the second resistor having a value of around 1000 Ω and the inductor measured previously (in the range 3 5 mh) to produce a cutoff frequency near 40 khz (not critical) according to the formula f c = w c /2π = R/2πL. Perform the same set of measurements as with the R C filter, but adjust your data range to account for the higher cutoff frequency. The goal is to show the frequency response rolloff with data points

above and below the cutoff frequency. Get data for both amplitude and phase. Note 4: The L R circuit is rarely a concern in electronic design except at radio frequencies (rf) and higher. This is because stray inductance is usually negligible. If the inductor and resistor are exchanged, the circuit becomes a high pass filter. Analysis and writeup The voltage measured at the output of the R C circuit is given by: and for the L R circuit: To model the experimental response, you will need to put the right hand side of the above equations in the form a + jb, where a and b are the real and imaginary parts of the complex number. The frequency dependent amplitude response is then: and the phase response is: Don't forget that the function generator frequency display (Hz) is related to the angular frequency (radians/sec) by the following equation: f = ω / 2π. The lab writeup requires the following: 1) Plot Vout/Vin for the R C circuit. Because this is a complex response, you will need to plot the amplitude and phase data on separate graphs. The amplitude response is a voltage ratio and is dimensionless on the y axis. Display the phase data in degrees (not radians). The x axis of both plots should be frequency (f) in units of Hz or khz. 2) Repeat the analysis described in 1) for the R L circuit.

3) The four data sets generated in 1) and 2) have corresponding theoretical curves. These continuous curves are obtained with the equations described above and using your measured values for R, L, and C. Add the theory curves to the four plots from 1) and 2) (i.e. you should produce two amplitude curves and two phase curves). List the measured component values. Include your equation formulas on each plot. There is no additional writing or explanation required. Your assignment is to generate four graphs (2 amplitude graphs, 2 phase graphs with your data compared to theory) corresponding to the two circuits. The report is due before the next class. E mail your 4 graphs as a single electronic file (.pdf preferred) to the instructor.