USER MANUAL. GOLDMUND Metis 5 Analog Integrated Amplifier

Similar documents
USER MANUAL. GOLDMUND METIS 2 Analog Preamplifier

USER MANUAL. Goldmund TELOS 390 INTEGRATED AMPLIFIER

USER MANUAL. GOLDMUND MIMESIS 27.5 Analog Preamplifier

USER MANUAL. GOLDMUND TELOS 2500 NextGen Universal Power Amplifier

USER MANUAL. GOLDMUND TELOS 590 NextGen Integrated Amplifier

USER MANUAL. GOLDMUND SR150 2-CHANNEL Universal Power Amplifier

USER MANUAL. GOLDMUND SRM250 Power Amplifier

USER MANUAL GOLDMUND TELOS 600 Universal Power Amplifier

USER MANUAL. GOLDMUND TELOS 1000 Universal Power Amplifier

USER MANUAL. GOLDMUND TELOS Universal Power Amplifier

GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER

USER MANUAL GOLDMUND MIMESIS 29M Millennium Edition Power Amplifier

You have acquired the best multi-usage Preamplifier ever made for professional and domestic uses. Please take some

Opus 21 s80 Integrated Amplifier Owner's Manual

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

REF1000. Mono Audio Power Amplifier

Boulder W Class A Stereo Power Amplifier

S500 Dual Mono Audio Amplifier

ECI 6D. Balanced Integrated Amplifier. Owner's Manual. (with a built-in DAC) ENGLISH

AELIUS YPSILON POWER AMPLIFIER. OWNERS MANUAL V1 01/01/20010 All rights reserved

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

Owner s manual. SDA 2175 Semi Digital Amplifier

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

3050 Stereo Power Amplifier

Phono3. Two Channel Analog RIAA MM/MC Pre-Amplifier

Hegel H2A High End Power Amplifier

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

AW 2x120 BALANCED POWER AMPLIFIER

Boulder W Mono Power Amplifier

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

PST 100 YPSILON PRE AMPLIFIER MKII. OWNERS MANUAL V2 01/01/2010 All rights reserved

IMPORTANT SAFETY INSTRUCTIONS

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

TABLE OF CONTENTS. 1) Introduction 2. 2) Unpacking your preamplifier 2. 3) Installing the preamp into your system 3

EC 4.6 REMOTE CONTROLLED BALANCED LINE PREAMPLIFIER

Model 112 Stereo Power Amplifier Owner s Manual

F O R T H E L O V E O F M U S I C LP100 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

AMP-150 integrated amplifier. User Manual

plifier D-501 otion Am Tactile M

M-300 Mono power amplifier User s guide

Registration 3. Owners Record Setup 4. Unit Connections 6. Front Panel Controls 8. Remote Control 9. Unit Care Technology 10. Designer s Note 12.

Illustration 1 Back panel. Illustration 2 Front panel

audionet AMP 1 V2 User s Manual Stereo - Amplifier

MUSICA C101 preamplifier

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

Jeff Rowland Design Group, Inc. Welcome to the Jeff Rowland Design Group family and congratulations on your purchase of what is

AW-250 DUAL MONO BALANCED POWER AMPLIFIER

1160 Stereo Power Amplifier

The Alpha Omega 900 amplifies the best qualities of one of the most powerful and distinct Darkglass pedals ever made.

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

SA 125 mixer amplifier. user manual

Owner s Manual. MOON Series. Titan HT-200. Multi-Channel Power Amplifier

AW-120 DUAL MONO FTT BALANCED POWER AMPLIFIER

User Manual (English)

RUBBER BANDS USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

FORTE MONO POWER AMPLIFIER OWNER S MANUAL

S 1500 MULTI-CHANNEL INSTRUCTIONS FOR USE AMPLIFIER. Owner s Reference

Emotiva BasX A300 Stereo Power Amplifier

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

22A3 Monaural Amplifier Owner s Manual

FEATURES FRONT PANEL. INPUT : Use this jack to connect your instrument via a standard ¼ mono cable.

FEATURES FRONT PANEL. INPUT : Use this jack to connect your instrument via a standard ¼ mono cable.

Installer Guide. Read Me First... PA 8 ELITE PA 8 ULTRA ELITE PA 16 ELITE. Multi-Channel Power Amplifiers. If you need help...

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

Model 12 Mono Power Model Amplifier 12 Owner s Manual

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Dodecahedron Speaker Set

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

EL34 CLASS AB PUSH-PULL INTEGRATED AMPLIFIER

Boulder 810 Preamplifier

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

This Level 3 amplifier features Audio Note copper and silver wiring and Audio Note capacitors. UNPACKING AND INSTALLATION

PROFESSIONAL SMPS STEREO AMPLIFIERS USER GUIDE

Model 301 New Version Serial Numbers Ma MA0161 Mono Power Amplifier

LL1.1 Signature preamplifier

Owner s Manual. Model: SP-120MKII KT88 Ultra-linear Integrated Stereo Tube Amplifier

E-400 power amplifier. user manual

OWNER S MANUAL THE SONIC FRONTIERS SFL-1 & SFL-1 SIGNATURE PREAMPLIFIER

Professional Power Amplifier

PROFESSIONAL SOUND EQUIPMENT MANUAL MPA

Sterling. Power Amplifiers User Manual. Models Covered

F O R T H E L O V E O F M U S I C SERIES 218 DPS200 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

CIRCUIT-TEST ELECTRONICS

Amplifier Series BASIC. Installation & Operations Manual

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

Owner s manual & Installation manual Mode d emploi et manuel d installation Manual de instrucciones y de instalación XC6210 XC6410

Thank you very much for choosing Shuguang Audio Classic Series vacuum tube amplifier

S 275 Stereo Power Amplifier THE LEADER IN AUDIO ENGINEERING. Instructions for Use. Owner s Reference

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

audionet 4 Channel Amplifier Owner's Manual

SA-103. Power Amplifier Instruction Manual. The heart of music

User Manual. imix 63 Stereo mixing preamplifier

OWNER S MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES

L-7000 LINE STAGE PREAMPLIFIER OWNER S MANUAL

Instruction Manual

2BSST POWER AMPLIFIER OWNER S MANUAL

E-800 power amplifier. user manual

10/12/15 inches 2-way amplified speakers with bass reflex

Transcription:

USER MANUAL GOLDMUND Metis 5 Analog Integrated Amplifier

Thank you for purchasing the Goldmund METIS 5 Analog Integrated Amplifier. The Goldmund Metis line amplifiers fully incorporate the technological expertise developed by our company throughout many years. Please take some time to read this manual. It will provide you with useful information to make your pleasure of listening to the Metis 5 even higher. INTRODUCTION GOLDMUND METIS 5 Analog Integrated Amplifier Goldmund was founded in 1978 and has ever since been dedicated to the accurate reproduction of sound and image. At Goldmund, we strive to lead in the creation, development and manufacture of the industry s most advanced technologies, including audio and video systems. The guiding principle at Goldmund is to produce a precise sound with the least possible loss of quality through the different stages. Goldmund will never adopt a technology before it is sufficiently developed to satisfy the high quality standards we set. This is why Goldmund has often rejected mainstream technologies and developed its own.

Table of Contents 1 UNPACKING 5 2 AMPLIFIER LOCATION & COOLIN 5 3 CONNECTIONS & LINE VOLTAGE 6 4 AMPLIFIER CONTROLS 7 5 SOUND QUALITY OPTIMIZATION 8 6 MAINTENANCE AND CLEANING 8 7 TECHNICAL SPECIFICATIONS 9 8 BACK PANEL PICTURE 12 GOLDMUND METIS 5 - Integrated Amplifier - 3

W A R N I N G! This high quality amplifier possesses new technical features such as ultra-high band width and computer linking which are necessary for accurate transcription within today s best audio systems. Only careful use can provide all the satisfaction you are expecting. All handling must be performed according to the following instructions to avoid impairing the amplifier s performance. Nevertheless, if the instructions are perfectly carried out, you will notice that the use of the GOLDMUND METIS 5 is quite simple and convenient. IMPORTANT PLEASE DO NOT CONNECT ANY CABLES OR MOVE ANY PARTS BEFORE READING THE FOLLOWING INSTRUCTIONS. GOLDMUND METIS 5 - Integrated Amplifier - 4

1 UNPACKING You will find within the custom packaging: - The Metis 5 amplifier, - The remote control & batteries (to be fitted before use), - The power cord, - This owner's manual. Unpack the above-mentioned parts carefully. Keep all packaging for future use. WARNING If you need to return the Metis 5 to the factory or to your local representative for a warranty repair, please note that it must be repacked in the original packaging. This packaging has been designed specifically to protect your Metis 5 in transit. Use of alternative packaging is likely to result in damage, invalidating warranty cover. 2 AMPLIFIER LOCATION & COOLING The Metis 5 amplifier, like all high quality amplifiers, generates a lot of heat when driven at high levels and therefore must be vented properly. It is mandatory to allow proper cooling of the heat sinks. Do not put temperature sensitive equipment on top of the amplifier. GOLDMUND METIS 5 - Integrated Amplifier - 5

3 CONNECTIONS & LINE VOLTAGE Connect the power cord to the back of the amplifier and plug it into the nearest wall plug. For safety reasons, use only a 3 lugs grounded plug. To get the best sound from the amplifier, avoid any multi-way plugs or extension cords. Connect the speaker cables to the binding posts on the rear panel. Connect the interconnects from any analog sources to line inputs 1 to 5. AT T E N T I O N A residual high frequency noise may remain audible in some circumstances if an input is left open and is selected. This disturbance has no effect on the amplifier but may be avoided easily through the application of short-circuit plugs on all unused inputs. LINE VOLTAGE The Goldmund Metis 5 integrated amplifier is preset at the factory for your country's voltage. It functions with AC voltages between either, 211V and 257V, or, 105V and 129V. If your AC line is usually out of these tolerances, please consult your local Goldmund dealer. Please check the value of the mains line fuse. This fuse is located in the power cord receptacle. The lid can be removed with a small screwdriver when the cord is removed. Use a 5A slow-blow fuse. GOLDMUND METIS 5 - Integrated Amplifier - 6

4 AMPLIFIER CONTROLS POWER The METIS 5 integrated amplifier is powered on using the switch located on the back panel. In regular use this switch should be left ON at all times (see sound quality optimization). The standby function of the remote control should be used to mute the signal for safe removal of cables. When in standby mode the front panel operation LED will stay lit. The amplifier is powered OFF by switching the back panel switch to the OFF position. A safety circuit switches the unit to mute to avoid any disturbance reaching the speakers. MUTING To mute the preamplifier output, press the "MUTE" key. The same operation repeated brings back the amplifier to normal operation at the same volume as in operation at the point the mute function was activated. VOLUME ADJUSTMENT The level control may be adjusted manually using the front panel knob or by using the + and - buttons on the remote control. SELECTOR The selector now selects one of five available inputs. Each step clockwise selects the next input in sequence. Selection may also be made using the remote control by pressing the key corresponding to the input on the remote control. GOLDMUND METIS 5 - Integrated Amplifier - 7

5 SOUND QUALITY OPTIMIZATION WARM UP SONIC EFFECT If the amplifier has been powered off for some time, the optimum sound quality is only reached a f t e r some time. It may take 15 minutes for the amplifier to reach optimum operating temperature, as the circuits have to warm up to around +55 degrees Celsius (=131degrees Fahrenheit). 6 MAINTENANCE AND CLEANING The Metis 5 amplifier usually requires no maintenance. Please contact your Goldmund approved dealer if any maintenance should be required. Always turn the power OFF before cleaning your amplifier. To clean the external metal of the amplifier, always use a clean, soft, damp cloth. Dampen it with water or a mild detergent solution. Avoid abrasive or harsh cleansers (e.g. products containing sodium carbonate). The identification plates are plated with precious metal. Simply clean them with a soft cloth, without any chemical solution. GOLDMUND METIS 5 - Integrated Amplifier - 8

7 TECHNICAL SPECIFICATIONS FRONT PANEL CONTROLS Volume Control Selector Input Switch IR Receiver for Remote Display of playback level Display of input selected Power led BACK PANEL CONTROLS On/Off switch Power cord socket 3 lugs Inputs Outputs INPUTS 5 pairs of RCA inputs (right and left) Input impedance: 50 kohms Maximum input level (unbalanced): 3.6 V RMS OUTPUTS 2 pairs of output Speaker connectors (right and left) POWER SUPPLY 3 toroidal transformers 3 separated power supply Power cord socket (3 lugs) Mains fuse (5A slow-blow) GROUNDING Separated ground and earth signal Connection between earth and ground to cancel all ground loops SAFETY FEATURES Automatic switching to MUTING if the AC line drops or is interrupted GOLDMUND METIS 5 - Integrated Amplifier - 9

7 TECHNICAL SPECIFICATIONS (Ctd.) POWER Power RMS (Goldmund FPP Standard): 150W on 8 Ohms Peak Power/Maximum voltage: 225W on 8 Ohms Nominal line voltage: 117 or 234 V Input voltage range: +/- 10 %. Maximum mains consumption at 234V: 70 W Power consumption in standby: 27 W CIRCUIT SPEED Rise time: < 800 ns. FREQUENCY RESPONSE These values for any level to maximum output level +/- 0.15 db, 10-20 khz +/- 0.6 db, 10 100 khz +/- 1.2 db, 10 200 khz DISTORTION With 1 Vrms output level, 80 khz measurement bandwidth, 600 ohms termination impedance THD unbalanced in to balanced out 0.01 % flat with frequency IMD unbalanced in to balanced out 0.01 % NOISE Signal-to noise ratio on line input: > 80 db (0.01 Hz - 10 Mhz) Weighted ASA A: > 90 db OPERATING TEMPERATURE Room temperature: -30 to +40 degrees Celsius ( -22 to +104 degrees Fahrenheit) Internal temperature: +45 to +65 degrees Celsius ( +113 to +149 degrees Fahrenheit) GOLDMUND METIS 5 - Integrated Amplifier - 10

7 TECHNICAL SPECIFICATIONS (Ctd.) SIZE AND WEIGHT 370 mm (14.56") W x 342 mm (13.46") D x 60 mm (2.36") H Total weight: 9 Kg WARRANTY 3 years, parts and labor. Information and product specifications contained in this manual are subject to change without prior notice. Updated versions of this manual will be posted on our website at www.goldmund.com. Please visit our support page at http://www.goldmund.com/support/register to register your Goldmund product for warranty. GOLDMUND METIS 5 - Integrated Amplifier - 11

8 BACK PANEL PICTURE GOLDMUND METIS 5 - Integrated Amplifier - 12