TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

Similar documents
INSTRUMENT TRANSFORMERS INSTRUMENT TRANSFORMERS OUTDOOR TYPES

Medium-voltage transfomers

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

W DATA SHEET Current Transformer 40 x 10, A

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

Voltage Instrument Transformer Medium Voltage Block Type 7,2 kv - 24 kv

VT guard Frequntly Asked Questions

Capacitive voltage transformers

Type CP-S, CP-C & CP-A Switch mode

High voltage engineering

On-Load Tap Changer Type M

Primary Metering. What is Primary Metering?

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

A Special Ferro-resonance Phenomena on 3-phase 66kV VT-generation of 20Hz zero sequence continuous voltage

Three-phase monitoring relays CM-PFE and CM-PFE.2

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Ferroresonance in MV Voltage Transformers: Pragmatic experimental approach towards investigation of risk and mitigating strategy

Capacitive voltage transformers

Substation Preventive Maintenance

7P Series - Surge Protection Device (SPD) Features 7P P P

Tab 8 Surge Arresters

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Current and Voltage (potential) Instrument transformers Instruction for installation, use and maintenance

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

38 Series - Relay interface modules A. Features /

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

MINISTRY OF ELECTRICITY

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Earthing of Electrical Devices and Safety

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

ON LOAD TAP CHANGERS RS 9.3 / RS 9 TECHNICAL DATA

Earth fault protection for isolated neutral systems with frequency converters

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

LED Driver Compact fixed output

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

3. COMBINED TRANSFORMERS Oil-paper insulation

48 Series - Relay interface modules A. Features

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Resistive capacitive voltage divider

Current / residual current and voltage transformers. Current / residual current and voltage transformers

I -limiter The world s fastest switching device

Relay interface modules A

Fuse Links NV/NH gg with Striker Pin Dimensions

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

Three-phase monitoring relay CM-PFS

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

FERRORESONANCE SIMULATION STUDIES USING EMTP

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Utility System Lightning Protection

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

BOX TRANSDUCER TYPE CODE DESIGNATION

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Three-phase monitoring relay CM-PVE

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

MEDIUM & HIGH VOLTAGE

Resistive capacitive voltage divider

High Performance Current Transducer ITL 900-T = A

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Liquid level monitoring relay CM-ENS.2x

On-load tap-changer VACUTAP VRD, VRF, VRG

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

VI 3 - i TABLE OF CONTENTS

Swiss quality combined with global experience

Specialists in HV and MV test and diagnostics. Testing in Substations

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

Transcription:

VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

INFORMATION ABOUT THE SAFE OPERATION OF VOLTAGE TRANSFORMERS OPERATION CONDITIONS FOR POTENTIAL TRANSFORMERS 1. When the secondary terminals are connected to the measuring or protection devices, one of the terminals should be earthed for safety as seen in FIGURE VT-1 2. The base plate must be earthed. 3. The secondary circuits must not be short-circuited during operation. Otherwise the voltage transformers will be thermally destroyed. 4. If any of the secondary windings of a voltage transformer, used for the purpose of measuring, will not be used then it must be left open with one terminal connected to earth as seen in FIGURE VT-2. However, even if the open-delta windings are not to be used for detection of earth faults, they must be connected in an open delta circuit and an appropriate resistor (depending on the voltage and thermal power rating of the secondary) must be connected and open-delta circuit must be earthed only at one point as seen on FIGURE VT-4. Please refer to the technical recommendations below. 5. For single phase transformers, the neutral terminal of the primary N must be earthed in the earthed (neutral) systems as seen in FIGURE VT-3 Other important points and notes When using single pole insulated inductive voltage transformers, it is very important to be aware that, if a circuit is being closed or during the decaying period of an earth fault, ferroresonance may occur. Ferroresonance can lead to the overheating and thermal destruction of the voltage transformer or high levels of voltages may be induced. In general, ferroresonance can be eliminated by the use of an appropriate resistor. The resistor is placed as a burden in open-delta circuit formed by three voltage transformers delta windings. The open-delta circuit must always be earthed only at one point as seen in FIGURE VT-4. The open-delta connection can also be used for earth-fault monitoring with appropriate devices. As the number of cable systems is increasing in the energy distribution systems, the protection of voltage transformers have become very important for the uninterrupted operation of the system without any failure and/or down time. For that reason, ALCE is always recommending the use of open-delta windings in single phase inductive voltage transformers. The use of open-delta windings may not be sufficient for the protection of voltage transformers by itself in some cases. An energy systems design engineer shall always use proper surge arresters, avalanche diodes, limiters and/or their combinations for the survivability of the distribution system after a fault or disturbance.

01 PRODUCT OVERVIEW ASSEMBLY R S A B A N a b a n V FIGURE VT-1 FIGURE VT-3 A B da dn dn da a b Earth fault winding resistor da dn FIGURE VT-2 FIGURE VT-4 Test Voltages Highest voltage for equipment Um (r.m.s.) Rated power-frequency withstand voltage (r.m.s.) Rated lightning impulse withstand voltage (peak) [kv] [kv] [kv] 12 28 75 17,5 38 95 24 50 125 36 70 170

VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS 12-24-36kV Touch Proof Type Single pole insulated For switchgears insulated with SF6 gas TECHNICAL DATA Type VEI-24 VEG-36 Rated data Highest voltage for equipment, Um [r.m.s.] [kv] 12-24 24-36 Test voltages [kv] 28/75-50/125 50/125-70/170 Rated frequency [Hz] 50 or 60 Rated primary voltage, Un[max.] [kv] 12/ 3 24/ 3 24/ 3 36/ 3 Secondary voltage [V] 100 / 3 or 110 / 3 or 120 / 3 Rated burden in class 0.2-0.5-1.0 Maximum rated burder for protection purpose in class 3P/6P Thermal limiting current for earth fault detection winding Rated voltage factor [8h] [VA] 5-10-15-20-30-40-50-60... [VA] 100 [A] 6 1,9 Un Weight [approx.] [kg] 24 36

03 PRODUCT OVERVIEW DIMENSIONS VEI-24A 279 Interface A type see drawing 110282_1201 148 max.um : 24kV 20 M8 218 304 202 347 Ø12 125 148 Secondary terminals, M6 max. 4 terminal 270 130 15 SCREW M5 M6 M8 TORQUE Nm 2-2.5 2.5-3.5 16-20 NOTE: N terminal of primary winding connected to base plate

VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS VEG-36B max. Um: 36kV Interface B Type see drawing 110282_1201 365 185 Secondary terminals, M6 up to 4 terminals, M5 for 6 terminals 294 428 242.5 432.5 Ø12 165 186 300 150 40 SCREW TORQUE Nm M5 2-2.5 M6 2.5-3.5 M8 16-20 NOTE: N terminal of primary winding connected to base plate

05 PRODUCT OVERVIEW DIMENSIONS VEG-36N max. Um: 36kV Interface N Type see drawing 110282_1201 365 185 Secondary terminals, M6 up to 4 terminals, M5 for 6 terminals 294 402 242.5 432.5 Ø12 TECHNICAL DATA 165 186 300 150 40 SCREW M5 M6 M8 TORQUE Nm 2-2.5 2.5-3.5 16-20 NOTE: N terminal of primary winding connected to base plate

ALCE Elektrik Sanayi ve Ticaret A.Ş. Ramazanoğlu Mah. Transtek Cad. No:6 Pendik 34906 İstanbul, TURKEY T +90-216- 585 42 00 F +90-216- 378 23 27 www.alce-elektrik.com.tr info@alce-elektrik.com.tr K_EN_VT-GIS_OG_14R01