E3 Modulevel. Displacer operated level transmitter. Worldwide level and flow solutions. D E S C R I P T I O N

Similar documents
E3 Modulevel. Displacer operated level transmitter A G E N C Y A P P R O VA L S. For continuous level, density or liquid-liquid interface

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Guided Wave Radar Liquid-Liquid Interface Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

Kotron Sentinel Model 804 RF Level Transmitter

ECHOTEL 961/962 LINE POWERED

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Echotel Model 911/921 Ultrasonic Level Switches

Echotel Model 910 Ultrasonic Level Switch

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

ECHOTEL 961/962 LINE POWERED

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Echotel Trident 91S/92S Ultrasonic Level Switches

Solitel Vibrating Rod Level Switch

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions

Solitel Vibrating Rod Level Switch

THERMATEL MODEL TG1/TG2

Field indicator for current loops with HART communication Models DIH50, DIH52

Guided Wave Radar Level Transmitter

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Guided Wave Radar Level Transmitter

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

SITRANS T measuring instruments for temperature

Coriolis Massflowmeter

Design and applications

SALES SERVICE +358 (0)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Smart Displacer Level (Interface) Transmitter DLT100 Series

Level Measurement Continuous level measurement Radar transmitters

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

KFS. Flap-type flow meter. Design and range of application

Temperature Transmitter itemp RTD DIN rail TMT 127

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

OEM radar transmitter, for aggressive media level measurement

Positioner with HART Communication Type 3780

Level gauges Series LT Level indicator, switch and transmitter for liquids

Head mounted Temperature Transmitter TF02/TF02-Ex

Field indicator for current loops with HART communication Models DIH50, DIH52

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Coriolis Massflowmeter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

H O R I Z O N G U I D E D W A V E R A D A R

OPTIWAVE 1010 Technical Datasheet

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Advanced Guided Wave Radar Transmitter for Level Measurement and Control

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

IP26 Series Current to Pneumatic Converter

Analog Universal Module HART for Zone 2 Series 9468/33

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Submersible pressure sensor For oils and fuels Model LF-1

General Specifications

Level Measurement Continuous level measurement Radar transmitters

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Electro-Magnetic Flowmeters COPA-XE

Coriolis Mass Flow Meter Model TM

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Radar Level Measurement micropilot FMR 130 for stilling wells

Rod probe With coaxial tube reference probe

Rosemount 3101, 3102, and 3105

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Two-Wire Programmable Transmitter for:

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

SITRANS P. Transmitters for level. Introduction 1/42. Application

Fisher 646 Electro Pneumatic Transducer

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

0 2 1 â Ó. itemp HART TMT182. Technical Information

Echotel Model 961/962 Ultrasonic Level Switches

Level measurement Radar

SATRON VB Pressure Transmitter

Submersible pressure sensor For superior applications Model LF-1

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Submersible pressure sensor For water and wastewater Model LW-1

OPTIMASS 1000 Technical Datasheet

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

2-Wire. Level Gauge BM 702

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Transcription:

E3 Modulevel Displacer operated level transmitter www.modulevel.magnetrol.com D E S C R I P T I O N E3 Modulevels are 2 wire, loop powered level transmitters utilising buoyancy principle to detect and convert liquid level changes into a stable output signal. The linkage between the level sensing element and output electronics greatly simplifies mechanical design and construction. The in-line vertical design of the transmitter reduces instrument weight and the effects of process vibration on electronic circuitry components while simplifying installation. For continuous level, density or liquid-liquid interface F E AT U R E S Operation functions include: - interface measurement and detection - continuous level measurement - density measurement 2 line x 8 characters LCD and 3 button keypad. Easy bench configuration. No need for level simulation. Two-wire, intrinsically safe loop powered level transmitter. 360 rotatable housing can be dismantled without depressurizing the vessel. Special options, materials and custom engineered features. Suited for SIL 1 and SIL 2 loops. SFF of 92,3 % (full FMEDA report available). SAFETY INTEGRITY LEVEL A G E N C Y A P P R O VA L S A P P L I C AT I O N S MEDIA: liquids with a S.G. as low as 0,23 up to 2,2 and interfaces with a minimum density difference of 0,10 kg/dm 3. VESSELS: most process vessels up to 315 C (600 F) process temperature and pressures up to 355 bar (5150 psi) or storage vessels e.g: - feedwater heaters - condensate Drip Pots - scrubbers - separators - receivers - flash tanks - knock out drums - boilers Agency ATEX FM explosion proof FM intrinsically safe LRS RosTech/FSTS Approval II 1G Ex ia II C T4, intrinsically safe II 1/2G Ex d II C T6, explosion proof Class I Div.1, Groups B,C,D Class II Div.1, Groups E,F,G Class III, Type 4X T5, IP66 Class I Div.1, Groups A,B,C,D Class II Div.1, Groups E,F,G Class III, Type 4X T4, IP66 Lloyds Register of Shipment (marine applications) Russian Authorisation Standards Worldwide level and flow solutions

P R I N C I P L E O F O P E R AT I O N Level Liquid level change acts upon the range spring supported displacer causing vertical motion of a core within a linear variable differential transformer (LVDT). The enclosing tube acts as a static isolation barrier between the LVDT and the process media. As core position changes with liquid level, voltages are induced in the secondary windings of the LVDT. These signals are processed in the electronic circuitry and used to control the output signal. Interface E3 Modulevel is capable of tracking the interface level of two immiscible liquids with different densities. Each unit is custom-made with a displacer specially designed for the userʼs application. This allows it to detect the position of a clean interface or an emulsion layer and convert it into a stable output signal. Contact the factory for assistance in specifying an E3 for interface service. Note that for proper interface detection, the entire displacer must always be immersed in liquid. LVDT Moving LVDT Core Enclosing tube Range spring Spring protection cap Displacer External cage Electronics incl. digital display / 3 button key pad Density Yet another capability of E3 Modulevel is to track the changing density of a liquid over a known density range and convert that into a stable output signal. As the density of the liquid changes, so does the mass of the liquid displaced by the specially designed displacer. The resulting change in buoyancy force on the displacer causes the movement of the LVDT core necessary to convert the density change to the output signal. PA C T w a r e P C S O F T WA R E P R O G R A M FDT technology provides an open communication interface between field instruments of various communication protocols and the host/ DCS system. The DTM driver is typical for one type of instrument and delivers the full functionality of the device added with graphical user interface via a laptop or PC. Magnetrol transmitters use the free shareware PACTware software to support DTM drivers and the FDT functionality. Via PACTware it becomes easy to configure, monitor and diagnose a Magnetrol transmitter from distance or even to call for factory assistance over the internet via the supply of screenshots of on-line parameters and trending graphs. Magnetrol DTM library HART has passed the dtminspector, the official FDT interoperability test and certification tool. The Magnetrol DTMʼs are free of charge and can be downloaded from www.magnetrol.com/products/software/pactware or obtained via CD Rom from your nearest Magnetrol contact. PACTware CD with DTM drivers Magnetrol recommends the VIATOR USB HART Interface from MACTek Corporation. 2

M O U N T I N G -40 C to +70 C (-40 F to 160 F) E31/E32 Max 355 bar (5150 psi) Oil Water E33/E34 E35/E36 Max 315 C (600 F) - non steam Max 260 C (500 F) - steam E X P E D I T E S H I P P L A N ( E S P ) Several E3 Modulevel devices are available for quick shipment, within max. 4 weeks after factory receipt of purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently grey coded in the selection data charts. To take advantage of ESP, simply match the grey coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. S E L E C T I O N D ATA A complete measuring system consists of: 1. One order code for a complete standard E3 Modulevel transmitter. Order code for modified models/adders: put an "X" in front of the closest matching order code and specify the modification/adders separately. e.g: XE35-KQ3A-H1B X = material certification EN 10204-3.1 2. Options: - Adjustable displacer hanger for top mounted units, cable length 2,5 m (8'). Order code 032-3110-004 required when distance between the top of the displacer and the flange face is > dimension A (see page 10 & 11) + 60 mm (2.36"). - Free of charge: Magnetrol master C.D. with E3 Modulevel DTM (PACTware ). Order code: 090-BE59-200 (included in each order). 3

S E L E C T I O N D ATA N O N S T E A M a p p l i c a t i o n s ( m a x 6 0 0 l b s ) BASIC MODEL NUMBER Carbon steel models E 3 1 top mounted E3 Modulevel E 3 3 E3 Modulevel with side/bottom cage E 3 5 E3 Modulevel with side/side cage Stainless steel models E 3 2 top mounted E3 Modulevel E 3 4 E3 Modulevel with side/bottom cage E 3 6 E3 Modulevel with side/side cage SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications) Match temperature extensions with max. process temperature (digit 9) 150 C 200 C 230 C 290 C 315 C max. temp. / S.G. J A M D M 0.23-0.54 specific gravity K B N E N 0.55-1.09 specific gravity L C P F P 1.10-2.20 specific gravity PROCESS CONNECTION For top mounted connection type 150 lbs RF E31/E32 - ANSI Flange rating 300 lbs 600 lbs RF RF RJ For external cage models E33... E36 - ANSI Flange/Cage rating 150 lbs 300 lbs 600 lbs RF RF RF RJ P3 P4 P5 PK 1 1 /2" PN 16 Type B1 E31/E32 - EN 1092-1 (DIN) Flange rating PN 25/40 Type B1 PN 63 Type B2 PN 100 Type B2 G3 G4 G5 GK 3" EA EC ED EE DN 80 H3 H4 H5 HK 4" FA FC FD FE DN 100 K3 K4 K5 KK 6" GA GC GD GE DN 150 Q3 Q4 Q5 QK 2" A3 A4 A5 1 1 /2" NPT-F E3 E4 E5 2" NPT-F R3 R4 R5 1 1 /2" S.W. F3 F4 F5 2" S.W. PN 16 Type B1 E33... E36 - EN 1092-1 (DIN) Flange rating PN 25/40 PN 63 PN 100 Type B1 Type B2 Type B2 CA CC CD CE DA DC DD DE DN 40 DN 50 LEVEL RANGE 356 813 1219 1524 1829 2134 2438 2743 3048 mm 14 32 48 60 72 84 96 108 120 inches A B C D E F G H I code TRANSMITTER ELECTRONICS OUTPUT/COMMUNICATION H F 4-20 ma with Hart communication incl. display / 3 button keypad FOUNDATION Fieldbus communication incl. display / 3 button keypad MAX PROCESS TEMPERATURE Match max. process temperature with temperature extensions (digit 4) 1 Process temp. up to +290 C (+550 F) digit 4: ALL 3 Process temp. from +291 C (+551 F) up to +315 C (+600 F) digit 4: M, N or P APPROVALS & HOUSING Cast aluminium Stainless Steel Housing material 3/4" NPT M20 3/4" NPT M20 Cable entry Approval J K L M Weatherproof A B C D ATEX and FISCO intrinsically safe E F G H ATEX (Hart and FF) Explosion proof 5 6 7 8 FM and FISCO intrinsically safe 1 2 3 4 FM (Hart and FF) Explosion proof E 3 complete order code for E3 Modulevel transmitter NON STEAM applications 4

S E L E C T I O N D ATA S T E A M a p p l i c a t i o n s ( m a x 6 0 0 l b s ) BASIC MODEL NUMBER Carbon steel models E 3 1 top mounted E3 Modulevel E 3 3 E3 Modulevel with side/bottom cage E 3 5 E3 Modulevel with side/side cage Stainless steel models E 3 2 top mounted E3 Modulevel E 3 4 E3 Modulevel with side/bottom cage E 3 6 E3 Modulevel with side/side cage SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications) Match temperature extensions with max. process temperature (digit 9) 150 C 200 C 230 C 260 C max. temp. / S.G. K B N E 0.55-1.09 specific gravity PROCESS CONNECTION For top mounted connection type E31/E32 - ANSI Flange rating 150 lbs RF 300 lbs RF 600 lbs RF RJ For external cage models E33... E36 - ANSI Flange/Cage rating 150 lbs 300 lbs 600 lbs RF RF RF RJ P3 P4 P5 PK 1 1 /2" PN 16 Type B1 E31/E32 - EN 1092-1 (DIN) Flange rating PN 25/40 Type B1 PN 63 Type B2 PN 100 Type B2 G3 G4 G5 GK 3" EA EC ED EE DN 80 H3 H4 H5 HK 4" FA FC FD FE DN 100 K3 K4 K5 KK 6" GA GC GD GE DN 150 Q3 Q4 Q5 QK 2" A3 A4 A5 1 1 /2" NPT-F E3 E4 E5 2" NPT-F R3 R4 R5 1 1 /2" S.W. F3 F4 F5 2" S.W. PN 16 Type B1 E33... E36 - EN 1092-1 (DIN) Flange rating PN 25/40 PN 63 PN 100 Type B1 Type B2 Type B2 CA CC CD CE DA DC DD DE DN 40 DN 50 LEVEL RANGE 356 813 1219 1524 1829 2134 2438 2743 3048 mm 14 32 48 60 72 84 96 108 120 inches A B C D E F G H I code TRANSMITTER ELECTRONICS OUTPUT/COMMUNICATION H F 4-20 ma with Hart communication incl. display / 3 button keypad FOUNDATION Fieldbus communication incl. display / 3 button keypad MAX PROCESS TEMPERATURE Match max. process temperature with temperature extensions (digit 4) 1 Process temp. up to +150 C (+300 F) digit 4: K 2 Process temp. from +151 C (+301 F) up to +230 C (+450 F) digit 4: B or N 3 Process temp. from +231 C (+451 F) up to +260 C (+500 F) digit 4: E APPROVALS & HOUSING Cast aluminium Stainless Steel Housing material 3/4" NPT M20 3/4" NPT M20 Cable entry Approval J K L M Weatherproof A B C D ATEX and FISCO intrinsically safe E F G H ATEX (Hart and FF) Explosion proof 5 6 7 8 FM and FISCO intrinsically safe 1 2 3 4 FM (Hart and FF) Explosion proof E 3 complete order code for E3 Modulevel transmitter STEAM applications 5

S E L E C T I O N D ATA N O N S T E A M a p p l i c a t i o n s ( f r o m 9 0 0 l b s t o 2 5 0 0 l b s ) BASIC MODEL NUMBER Carbon steel models E 3 1 E 3 3 E 3 5 top mounted E3 Modulevel E3 Modulevel with side/bottom cage E3 Modulevel with side/side cage Stainless steel models E 3 2 top mounted E3 Modulevel E 3 4 E3 Modulevel with side/bottom cage E 3 6 E3 Modulevel with side/side cage SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications) Match temperature extensions with max. process temperature (digit 9) 150 C 200 C 230 C 290 C 315 C max. temp. / S.G. K B N E N 0.55-1.09 specific gravity PROCESS CONNECTION For top mounted connection type E31/E32 - ANSI Flange rating 900 lbs RJ 1500 lbs RJ E31/E32 - EN 1092-1 (DIN) Flange rating 2500 lbs RJ ➀ PN 160 PN 250 PN 320 Type B2 Type B2 Type B2 GL 3" EF EG EH DN 80 HL HM HN 4" FF FG FH DN 100 KL KM KN 6" GF GG GH DN 150 For external cage models E33...E36 - ANSI Flange/Cage rating E33...E36 - EN 1092-1 (DIN) Flange rating 900 lbs 1500 lbs 2500 lbs PN 250 PN 320 RJ RJ RJ ➀ PN 160 Type B2 Type B2 Type B2 PL PM PN 1 1 /2" QL QM QN 2" CF CG CH AL AM AN 1 1 /2" NPT-F EL EM EN 2" NPT-F RL RM RN 1 1 /2" S.W. DF DG DH FL FM FN 2" S.W. DN 40 DN 50 ➀ Max. 355 bar (5150 psig) @ +40 C (+100 F) LEVEL RANGE 356 813 1219 1524 1829 2134 2438 2743 3048 mm 14 32 48 60 72 84 96 108 120 inches A B C D E F G H I code TRANSMITTER ELECTRONICS OUTPUT/COMMUNICATION H 4-20 ma with Hart communication incl. display / 3 button keypad F FOUNDATION Fieldbus communication incl. display / 3 button keypad MAX PROCESS TEMPERATURE Match max. process temperature with temperature extensions (digit 4) 1 Process temp. up to +290 C (+550 F) digit 4: ALL 3 Process temp. from +291 C (+551 F) up to +315 C (+600 F) digit 4: N APPROVALS & HOUSING Cast aluminium Stainless Steel Housing material 3/4" NPT M20 3/4" NPT M20 Cable entry Approval J K L M Weatherproof A B C D ATEX and FISCO intrinsically safe E F G H ATEX (Hart and FF) Explosion proof 5 6 7 8 FM and FISCO intrinsically safe 1 2 3 4 FM (Hart and FF) Explosion proof E 3 complete order code for E3 Modulevel transmitter NON STEAM applications / high pressure 6

S E L E C T I O N D ATA S T E A M a p p l i c a t i o n s ( f r o m 9 0 0 l b s t o 2 5 0 0 l b s ) BASIC MODEL NUMBER Carbon steel models E 3 1 E 3 3 E 3 5 top mounted E3 Modulevel E3 Modulevel with side/bottom cage E3 Modulevel with side/side cage Stainless steel models E 3 2 top mounted E3 Modulevel E 3 4 E3 Modulevel with side/bottom cage E 3 6 E3 Modulevel with side/side cage SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications) Match temperature extensions with max. process temperature (digit 9) 150 C 200 C 230 C 260 C max. temp. / S.G. K B N E 0.55-1.09 specific gravity PROCESS CONNECTION For top mounted connection type E31/E32 - ANSI Flange rating 900 lbs RJ 1500 lbs RJ E31/E32 - EN 1092-1 (DIN) Flange rating 2500 lbs RJ ➀ PN 160 PN 250 PN 320 Type B2 Type B2 Type B2 GL 3" EF EG EH DN 80 HL HM HN 4" FF FG FH DN 100 KL KM KN 6" GF GG GH DN 150 For external cage models E33...E36 - ANSI Flange/Cage rating E33...E36 - EN 1092-1 (DIN) Flange rating 900 lbs 1500 lbs 2500 lbs PN 250 PN 320 RJ RJ RJ ➀ PN 160 Type B2 Type B2 Type B2 PL PM PN 1 1 /2" QL QM QN 2" CF CG CH AL AM AN 1 1 /2" NPT-F EL EM EN 2" NPT-F RL RM RN 1 1 /2" S.W. DF DG DH FL FM FN 2" S.W. DN 40 DN 50 ➀ Max. 155 bar (5150 psig) @ +40 C (+100 F) LEVEL RANGE 356 813 1219 1524 1829 2134 2438 2743 3048 mm 14 32 48 60 72 84 96 108 120 inches A B C D E F G H I code TRANSMITTER ELECTRONICS OUTPUT/COMMUNICATION H F 4-20 ma with Hart communication incl. display / 3 button keypad FOUNDATION Fieldbus communication incl. display / 3 button keypad MAX PROCESS TEMPERATURE Match max. process temperature with temperature extensions (digit 4) 1 Process temp. up to +150 C (+300 F) digit 4: K 2 Process temp. from +151 C (+301 F) up to +230 C (+450 F) digit 4: B or N 3 Process temp. from +231 C (+451 F) up to +260 C (+500 F) digit 4: E APPROVALS & HOUSING Cast aluminium Stainless Steel Housing material 3/4" NPT M20 3/4" NPT M20 Cable entry Approval J K L M Weatherproof A B C D ATEX and FISCO intrinsically safe E F G H ATEX (Hart and FF) Explosion proof 5 6 7 8 FM and FISCO intrinsically safe 1 2 3 4 FM (Hart and FF) Explosion proof E 3 complete order code for E3 Modulevel transmitter STEAM applications / high pressure 7

T R A N S M I T T E R S P E C I F I C AT I O N S FUNCTIONAL/PHYSICAL Description ➀ Not applicable for FOUNDATION Fieldbus units. Specification Power (at terminals) Weatherproof / Intrinsically Safe: 11 to 28,4 V DC (ATEX) - 28,6 V DC (FM) ATEX Explosion Proof 11 to 36 V DC (ATEX-FM) FOUNDATION Fieldbus (FISCO Intrinsically Safe): 9 to 17,5 V DC FOUNDATION Fieldbus (Explosion proof): 9 to 32 V DC Signal Output 4-20 ma with HART, 3,8 ma to 20,5 ma useable (meets NAMUR NE 43), FOUNDATION Fieldbus H1 (ITK Ver. 5) Span from 356 mm up to 3048 mm (14" up to 120") - others at request Resolution Analog: 0,01 ma Display: 0,1 cm (inch) Loop Resistance 620 Ω @ 20,5 ma - 24 V DC Damping Adjustable 0-45 s Diagnostic Alarm Adjustable 3,6 ma, 22 ma, HOLD User Interface HART communicator, AMS or PACTware, FOUNDATION Fieldbus and 3-button keypad Display 2-line x 8-character LCD Menu Language English/Spanish/French/German (FOUNDATION Fieldbus : English) Housing Material IP 66/Aluminium A356T6 (< 0.20 % copper) or stainless steel Approvals ATEX II 1 G Ex ia IIC T4, intrinsically safe ATEX II 1 G Ex ia IIC T4, FISCO intrinsically safe ATEX II 1 / 2 G Ex d IIC T6, explosion proof FM, Intrinsically Safe (FISCO) and explosion proof FOUNDATION Fieldbus units are FISCO (intrinsically safe) and ATEX FM/CSA explosion proof approved LRS Lloyds Register of Shipping (marine applications) ROSTECH/FSTS Russian Authorisation Standards SIL ➀ (Safety Integrity Level) Functional safety to SIL 2 as 1oo1 in accordance to 61508 SFF of 92,3 % full FMEDA report and declaration sheet available at request Electrical Data Ui = 28,4 V, li = 94 ma, Pi = 0,67 W - ATEX Ui = 28,6 V, li = 140 ma, Pi = 1 W - FM Ui = 17,5 V, li = 380 ma, Pi = 5,32 W (FOUNDATION Fieldbus) Equivalent Data Ci = 2,2 nf, Li = 3 µh - ATEX Ci = 5,5 nf, Li = 9 µh - FM Ci = 0,71 nf, Li = 3 µh (FOUNDATION Fieldbus ) Shock/Vibration Class ANSI/ISA-571.03 SA1 (Shock), ANSI/ISA-571.03 VC2 (Vibration) Net and Gross Weight Cast aluminium 3 kg (7 lbs) amplifier only Stainless steel 8 kg (17 lbs) amplifier only Overall Dimensions H 306 mm (12.05") x W 112 mm (4.41") x D 192 mm (7.56") FOUNDATION ITK Version 5.0 Fieldbus specifications H1 Device Class Link Master (LAS) selectable ON/OFF H1 Profile Class 31PS, 32L Function Blocks 1 x AI and 1 x PID, 1 x RB, 1 x TB Quiescent current draw 17 ma Execution time AI: 15 ms, PID: 40 ms CFF files Downloads available from Host system supplier or www.fieldbus.org 8

PERFORMANCE Description Specification Linearity Level ± 0,50 % of full span Interface/Density ± 0,70 % of full span Repeatability Level ± 0,05 % of full span Hysteresis Response Time Warm-up Time Interface/Density ± 0,10 % of full span ± 0,05 % of full span < 1 second < 5 seconds Ambient Temp. -40 C to +80 C (-40 F to +175 F) electronics temperature range -20 C to +70 C (-5 F to +160 F) LCD temperature range -40 C to +70 C (-40 F to +160 F) for Ex ia and Ex d units Storage temperature -40 C to +85 C (-40 F to +185 F) Ambient Temp. Effect Max zero shift is 0,03 % / C (0,017 % / F) Process Max +260 C (+500 F) for steam / + 315 C (+600 F) for non steam Temp. ➀ Min -29 C (-20 F) for carbon steel models / -196 C (-320 F) for stainless steel models Max Process Pressure 355 bar @ +40 C (5150 psi @ +100 F). Density Range from 0,23 kg/dm 3 up to 2,20 kg/dm 3 Humidity 0-99 %, non-condensing Electromagnetic Compatibility Meets CE requirements (EN-61326: 1997 + A1 + A2) ➀ See temperature graphs at page 12. M E C H A N I C A L S P E C I F I C AT I O N S Description Specification Cage materials carbon steel or 316/316L (1.4401/1.4404) (other materials at request) Wetted parts Spring Inconel (other materials at request) Displacer 316/316L (1.4401/1.4404) or 316 (1.4401) Process Connection Threaded: 1 1/2" NPT-F or 2" NPT-F or 1 1/2" Socket Weld or 2" Socket Weld Flanged: Various ANSI or EN/DIN flanges Displacer lengths From 356 mm (14") up to 3048 mm (120") - other lengths at request E L E C T R I C A L W I R I N G Hazardous area Safe area I.S. 0 % 100 % AMS FDT/PACTware 9

D I M E N S I O N S i n m m ( i n c h e s ) Transmitter Head 102 (4.02) Top Mounted E31/E32 - J/K/L Side/bottom cage E33/E34 - J/K/L Dual Cable Entries 3/4" NPT or M20 x 1,5 407 (16) 407 (16) 22 (0.87) 72 (2.81) 98 (3.86) 159 (6.28) 262 (10.32) 206 103 (4.04) 70 100 (3.95) (8.10) A Level Range A Level Range ± 2 (0.08) 133 (5.24) C B Side/bottom cage E33/E34 - J/K/L Side/side cage E35/E36 - J/K/L Side/side cage E35/E36 - J/K/L 407 (16) 407 (16) 407 (16) A A A Level Range ± 2 (0.08) Level Range ± 2 (0.08) Level Range ± 2 (0.08) 133 (5.24) 133 (5.24) 133 (5.24) B T E M P E R AT U R E E X T E N S I O N S Models E3x-A/B/C 1" NPT-F drain (plug not supplied) B Models E3x-M/N/P 1" NPT-F drain (plug not supplied) B Models E3x-D/E/F 509 (20) 610 (24) 712 (28) 10

D I M E N S I O N S i n m m ( i n c h e s ) Dimension A for all models Cage rating SG range 4 th digit Dimension A 0.23-0.54 J/A/M/D 236 (9.29) 150 / 300 / 600 lbs PN 16.. PN 100 0.55-1.09 K/B/N/E 186 (7.32) 1.10-2.20 L/C/P/F 186 (7.32) 900 / 1500 lbs 245 (9.65) PN 160 / PN 250 0.55-1.09 K/B/N/E 2500 lbs 320 (12.60) PN 320 Dimensions B and C for external cage models (E33/E34/E35/E36) Flanged process connections Flange size Flange rating Connection type Dimensions B C 150 / 300 / 600 lbs Slip on - ANSI RF 180 (7.09) 268 (10.55) 600 lbs Weldneck - ANSI RJ 180 (7.09) 268 (10.55) 1 1/2" 900 lbs Weldneck - ANSI RJ 193 (7.60) 283 (11.14) 1500 lbs Weldneck - ANSI RJ 185 (7.28) 283 (11.14) 2500 lbs Weldneck - ANSI RJ 228 (8.98) 313 (12.32) 150 / 300 / 600 lbs Slip on - ANSI RF 185 (7.28) 273 (10.75) 600 lbs Weldneck - ANSI RJ 185 (7.28) 273 (10.75) 2" 900 lbs Weldneck - ANSI RJ 214 (8.43) 303 (11.93) 1500 lbs Weldneck - ANSI RJ 211 (8.31) 303 (11.93) 2500 lbs Weldneck - ANSI RJ 249 (9.80) 328 (12.91) PN 16 / PN 25 / PN 40 EN 1092-1 Type B1 180 (7.09) 268 (10.55) PN 63 / PN 100 EN 1092-1 Type B2 200 (7.87) 288 (11.34) DN 40 PN 160 EN 1092-1 Type B2 143 (5.63) 288 (11.34) PN 250 EN 1092-1 Type B2 177 (6.97) 303 (11.93) PN 320 EN 1092-1 Type B2 197 (7.76) 313 (12.32) PN 16 EN 1092-1 Type B1 185 (7.28) 273 (10.75) PN 25 / 40 EN 1092-1 Type B1 188 (7.40) 278 (10.95) PN 63 EN 1092-1 Type B2 202 (7.95) 293 (11.54) DN 50 PN 100 EN 1092-1 Type B2 208 (8.19) 298 (11.73) PN 160 EN 1092-1 Type B2 159 (6.26) 303 (11.93) PN 250 EN 1092-1 Type B2 186 (7.32) 313 (12.32) PN 320 EN 1092-1 Type B2 214 (8.43) 328 (12.91) Threaded / Socket weld process connections Cage rating Connection type Dimensions B C 150 / 300 / 600 / 900 lbs NPT/SW 81 (3.19) 1 1/2" 1500 lbs NPT/SW 89 (3.50) 2500 lbs NPT/SW 102 (4.02) Not 150 / 300 / 600 / 900 lbs NPT/SW 84 (3.31) Applicable 2" 1500 lbs NPT/SW 98 (3.86) 2500 lbs NPT/SW 111 (4.37) 11

O P E R AT I N G T E M P E R AT U R E S The following charts lists combinations of process and ambient temperatures that should not be exceeded, with standard instruments 350 Non-steam applications Process temperature C 300 250 200 150 100 50 0 30 35 40 45 50 55 60 65 70 75 Ambient temp. C Digit 4 = J/K/L Digit 4 = A/B/C Digit 4 = D/E/F Digit 4 = M/N/P and digit 9 = 3 Digit 4 = M/N/P and digit 9 = 1 Steam applications 350 Process temperature C 300 250 200 150 100 50 0 30 35 40 45 50 55 60 65 70 75 Ambient temp. C Digit 4 = K Digit 4 = B Digit 4 = E Digit 4 = N QUALITY ASSURANCE - ISO 9001:2008 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2008 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY :2008 ALL EZ MODULEVEL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE FULL YEARS (MECHANICAL PARTS) / ONE FULL YEAR (ELECTRONIC PARTS) FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION. MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS. UNDER RESERVE OF MODIFICATIONS BENELUX FRANCE DEUTSCHLAND Heikensstraat 6, 9240 Zele, België -Belgique Tel. +32 (0)52.45.11.11 Fax. +32 (0)52.45.09.93 E-Mail: info@magnetrol.be Alte Ziegelei 2-4, D-51491 Overath Tel. +49 (0)2204 / 9536-0 Fax. +49 (0)2204 / 9536-53 E-Mail: vertrieb@magnetrol.de INDIA C-20 Community Centre, Janakpuri, New Delhi - 110 0058 Tel. +91 (11) 41661840 Fax +91 (11) 41661843 E-Mail: info@magnetrolindia.com ITALIA Via Arese 12, I-20159 Milano Tel. +39 02 607.22.98 (R.A.) Fax. +39 02 668.66.52 E-Mail: mit.gen@magnetrol.it U.A.E. DAFZA Office 5EA 722 PO Box 293671 Dubai Tel. +971-4-6091735 Fax +971-4-6091736 E-Mail: info@magnetrol.ae UNITED Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL KINGDOM Tel. +44 (0)1444 871313 Fax +44 (0)1444 871317 E-Mail: sales@magnetrol.co.uk www.magnetrol.com OUR NEAREST REPRESENTATIVE BULLETIN N : BE 48-135.1 EFFECTIVE: OCTOBER 2009 SUPERSEDES: March 2009