Kotron Sentinel Model 804 RF Level Transmitter

Similar documents
Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Kotron Model 82 CE RF Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

Solitel Vibrating Rod Level Switch

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Model 911/921 Ultrasonic Level Switches

Solitel Vibrating Rod Level Switch

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Kotron Series 82 CE. Level. Transmitter. Installation and Operating Manual

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Level Lance Model 5100

Echotel Model 350/351

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Magnetostrictive Level Transmitter

Non-Submersible Industrial Pressure Transducer

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

Two-Wire Programmable Transmitter for:

Echotel Model 961/962 Ultrasonic Level Switches

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009

Radar Level Measurement micropilot FMR 130 for stilling wells

Programmable K-Factor Scaler B and Programming Software Kit B

Magnetostrictive Level Transmitter

K-FACTOR SCALER B & B

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Instruction Manual. HB Series Mini Level Sensor

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

STT 3000 Smart Temperature Transmitter

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Princo MagneLevel Model LML

Level Measurement Continuous level measurement Radar transmitters

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

DREXELBROOK. Universal Lite Series. RF Level Transmitter

670K9 SORtrax Level Transmitter

BC145 SIGNAL ISOLATOR BOARD

Guided Wave Radar Liquid-Liquid Interface Transmitter

SC-FI Series Frequency to Current Signal Conditioner

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Global Water Instrumentation, Inc.

RF Capacitance Level Controls

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

S11 Adjustable Speed Drive Engineering Specification

LT3000 ULTRASONIC LEVEL TRANSMITTER

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Wireless Base Radio. Wireless Transmitters

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

Instruction Manual. LD/LA Level Transmitter. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

MEAS CAL ALARM CONF APT2000 TC

LST100 Ultrasonic level transmitter for upstream oil and gas

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

CS02 CAPACITANCE TRANSMITTER. Continuous Output Transmitter with Advanced Features INSTALLATION AND OPERATIONS MANUAL

OPERATING INSTRUCTIONS

RF Capacitance Level Controls

H O R I Z O N G U I D E D W A V E R A D A R

HLC-1000 High-limit Humidity Control

Mass and Volume Flow Transmitter

Digital Lighting Systems, Inc.

Instruction Manual IUC-7X-RTX. X=1: Deg. F. X=2: Deg. F. X=3: Deg. F. X=7: X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7:

2-wire level transmitter

MODEL AT-10 ANALOG TRANSMITTER

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

CSIS CAPACITANCE TRANSMITTER. Intrinsically-Safe Continuous Output Level Transmitter INSTALLATION AND OPERATIONS MANUAL

Non-Spring Return EconoDrive Proportional Actuator

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

LST400 Ultrasonic level / open channel flow transmitter

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

R.F. Capacitance Dual-Point Level Control INSTALLATION & OPERATION MANAUL

Mass Flow and Density Transmitter with FOUNDATION fieldbus

LA-5000 SERIES LINEAR VALVE ACTUATORS

Submittal 420I Converter

MiniMe Two-Wire Ultrasonic Level Transmitter Model LU11/12/13/14 Owner s Manual

Installation guide 971 SmartRadar LTi

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Multi-electrode Conductivity Analyzers

Transcription:

Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display and keypad simplify calibration and setup of the instrument. Powerful diagnostics check all functions of the system, simplifying troubleshooting. MagneCal offers the user the greatest improvement in RF Capacitance one small level change is needed to calibrate. F E A T U R E S Two or four SPDT relays with gold flash contacts for alarm and control operation. Optional intrinsically safe probe circuitry (with on-board barriers). 16-button keypad and 2 16 LCD display. Isolated 4 20 ma output includes an active/passive mode. Relays can be configured for sequential or lead/lag pump control. One small level change (2% of span) needed for initial probe calibration. 4 20 ma and up to eight control points can be programmed with no level change. Powerful self-diagnostics check the system, including probe. Relay #1 can be dedicated as a diagnostics relay. A P P L I C A T I O N S Continuous level measurement Interface measurement Hydrocarbons and solvents Slurries Acids High temperature/pressure liquids

T E C H N O L O Y The amount of capacitance developed in any vessel is determined by: the size (surface area) of the probe; the distance from the probe to its ground reference; and the dielectric constant of the medium being measured. Considering that the probe s mounting position is fixed and the dielectric of the medium is constant, then the amount of capacitance developed in any vessel becomes dependent upon the amount of the probe which is covered with media. As the media rises and falls in the tank, the amount of capacitance developed between the probe and the ground reference also changes. The capacitance signal is converted to a frequency proportional to the change in level. The amplifier then converts this digital signal into an isolated 4 20 ma analog output signal. S P E C I F I C A T I O N S Supply voltage 120 VAC, 50/60 Hz (+10 15%) 240 VAC, 50/60 Hz (+10 15%) 24 VDC (±10%) Power consumption 15 VA nominal Ambient temperature range -40 to +160 F (-40 to +70 C) Humidity 99% non-condensing (electronics) Accuracy Better than ±1.0% Repeatability ±0.1% Linearity ±0.5% Temperature effect ±0.01%/ F (±0.018/ C) Operator interface: Data entry 16-button keypad Display 2 line 16 character LCD display Continuous Output: Active signal 4-20 ma (isolated), reversible, 1000 ohms max. loop resistance Passive signal 4-20 ma (isolated), reversible, loop resistance dependent on power supply Range 5 pf minimum; 50,000 pf maximum Damping 0-90 seconds Discrete output (SPDT) with gold flash contacts: Set point range 0-50,000 pf Adjustable differential range 0.5 pf minimum; 50,000 pf maximum Time delay 0-90 seconds level rising, level falling, both Relay output: AC 10 amp @ 120/240 VAC resistive DC 10 amp @ 30 VDC resistive 0.5 amp @ 125 VDC resistive Maximum remote cable length: Standard 2500 feet (760 meters) Intrinsically safe 800 feet (240 meters) 2

A E N C Y A P P R O V A L S Agency Approved Model Protection Method Area Classification FM 804-XXXX-23X Explosion proof Class I Div. 1, roups B, C & D 804-XXXX-33X Class II, Div. 1, roups E, F, & Insulated rigid probes only NEMA 4X, IP65 804-XXXX-53X Explosion proof Integral units 804-XXXX-63X with intrinsically safe Class I Div. 1, roups B, C & D probe circuit Class II, Div. 1, roups E, F, & NEMA 4X, IP65 Electronics Class I Div. 1, roups B, C & D Class II, Div. 1, roups E, F, & NEMA 4X, IP65 Remote probe Class I Div. 1, roups A, B, C & D Class II, Div. 1, roups E, F, &, NEMA 4X, IP65 CSA 804-XXXX-23X Explosion proof Class I Div. 1, roups C & D 804-XXXX-33X Class II, Div. 1, roups E, F, & Insulated rigid probes only TYPE 4X 804-XXXX-53X Explosion proof ➀ Integral units with IS probe circuit 804-XXXX-63X with intrinsically safe Class I Div. 1, roups B, C & D probe circuit Class II, Div. 1, roups E, F, & ➀ TYPE 4X Electronics Class I Div. 1, roups B, C & D Class II, Div. 1, roups E, F, & ➀ TYPE 4X Remote probe Class I Div. 1, roups A, B, C & D Class II, Div. 1, roups E, F, & ➀ TYPE 4X ➀ For Class II, roups E & F insulated probes must be used These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. 3

D I M E N S I O N A L I N C H E S ( m m ) S P E C I F I C A T I O N S 1 Rotation clearance A B 1 Rotation clearance A B C plugged C D plugged 2 Optional mounting flange 2.95 (75) D Optional 2 mounting flange.1875 (5).2500 (6).50 (13).625 (16) Integral Mount with Standard Rigid Probe Integral Mount with Flexible Probe 4.63 (118) Dia. 3.00 (76) 2.75 (70) 3.23 (82) 3 /4" NPT Optional mounting flange 2 Rigid Probe.50 (13).625 (16) 4

D I M E N S I O N A L S P E C I F I C A T I O N S ( c o n t. ) I N C H E S ( m m ) 1 Rotation clearance A B E 2 Holes.38 (10) Dia. 2.37 (60) plugged F 2.00 (51) 3.00 (76) 3.50 (89) 3 Remote Mount 1 /2" NPT or 3 /4" NPT 4.63 (118) Dia. 3.00 (76) 2.75 (70) 4.67 (119) 3 /4" NPT Optional mounting flange 2 2.95 (75).1875 (5).2500 (6) Flexible Probe Outline Dimensions Housing A B Standard Rigid Probe Flexible Probe C D E F C D E F NEMA 4X/7/9 3.87 5.93 10.89 2.44 13.44 4.11 12.33 4.71 13.44 4.11 Aluminum (98) (151) (276) (61) (341) (104) (313) (119) (341) (104) Conduit Connections NEMA 4X/7/9 (remote probe housing) Single conduit NEMA 4X/7/9 Dual conduit 3 4" NPT 1" NPT NOTES: ➀ Allow 8.00 (200) overhead clearance for cover removal. ➁ Standard process connection is 3 4" NPT. Consult probe bulletin (50-125) for flange and other probe connections. ➂ Probe/amplifier connecting cable to be shielded, twisted pair, 22-gauge stranded conductors, Magnetrol part number 009-7146-001; 2500 feet (760 m) maximum; 800 feet (240 m) maximum for intrinsically safe models. 5

M O D E L N U M B E R Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). BASIC MODEL 804 Sentinel RF Level Transmitter ELECTRONIC HOUSIN R NEMA 4X/7/9 aluminum, 1" NPT Y NEMA 4X/7/9 aluminum, 1" NPT with 316 SS, remote housing INPUT POWER 0 120 VAC 1 240 VAC 2 24 VDC ANALO OUTPUT/COMMUNICATIONS 1 4-20 ma 5 4-20 ma with RS-485 (Modbus) ALARM/CONTROL OUTPUT 0 No relays C (2) 10 amp SPDT relays with gold flash contacts D (4) 10 amp SPDT relays with gold flash contacts MOUNTIN 2 Integral explosion proof 3 Remote explosion proof 5 Integral explosion proof w/is safe probe circuit 6 Remote explosion proof w/is safe probe circuit ➀ ➀ Not available with Electronic housing code Y 8 0 4 3 0 P R O B E S R E M O T E C A B L E A full range of rigid and flexible probes, for conductive and non-conductive process media, is available in various lengths and materials of construction. For further information on probe assemblies, refer to bulletin 50-125. Remote cable should be shielded, twisted pair, 22-gauge stranded conductors and may be ordered using Magnetrol part number 009-7146-001. Cable length in feet must be specified at time of order; 2500 feet (760m) maximum; 800 feet (240 m) maximum for intrinsically safe models. 6

N O T E S 7

Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. E S P Expedite Ship Plan Several Kotron Model 804 RF transmitters are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 50-604. 5300 Belmont Road Downers rove, Illinois 60515-4499 630-969-4000 Fax 630-969-9489 www.magnetrol.com 145 Jardin Drive, Units 1 & 2 Concord, Ontario Canada L4K 1X7 905-738-9600 Fax 905-738-1306 Heikensstraat 6 B 9240 Zele, Belgium 052 45.11.11 Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. Burgess Hill, Sussex RH15 9TL U.K. 01444-871313 Fax 01444-871317 Copyright 2010 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. BULLETIN: 50-118.3 EFFECTIVE: February 2001 SUPERSEDES: September 2000