Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Similar documents
Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

Kotron Model 82 CE RF Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

Model R82 Pulse Burst Radar Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

Echotel Trident 91S/92S Ultrasonic Level Switches

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

Echotel Model 911/921 Ultrasonic Level Switches

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Solitel Vibrating Rod Level Switch

Solitel Vibrating Rod Level Switch

Fisher 646 Electro Pneumatic Transducer

Rosemount 3101, 3102, and 3105

Fisher 646 Electro-Pneumatic Transducers

Echotel Model 961/962 Ultrasonic Level Switches

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

2-wire level transmitter

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

LPU-2127 User Manual

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Model Sono-Trak Transit Time

Horizon Model 704 Guided Wave Radar Level Transmitter

Ultrasonic level transmitter, non-contact

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

IP26 Series Current to Pneumatic Converter

Process display RIA 261

prosonic T FMU230, FMU231

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

LT3000 ULTRASONIC LEVEL TRANSMITTER

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Advanced Guided Wave Radar Transmitter for Level Measurement and Control

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Two-Wire Programmable Transmitter for:

Ultrasonic Level Transmitter Model LU20 Owner s Manual

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

LST400 Ultrasonic level / open channel flow transmitter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Ult r a s o n i c le v e l me t e r s ULM 70

Ultrasonic level meters ULM 70

LST100 Ultrasonic level transmitter for upstream oil and gas

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Installation and maintenance manual. LSU 100, Ultrasonic level transmitter

Echotel Model 350/351

Model R86 26 GHz Pulse Burst Radar Level Transmitter

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Magnetostrictive Level Transmitter

OEM radar transmitter, for aggressive media level measurement

Accutech AM20. Wireless acoustic monitor field unit

Guided Wave Radar Liquid-Liquid Interface Transmitter

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Ultrasonic Level Transmitter Model LU30 Owner s Manual

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Specification DataFile

Level Measurement Continuous level measurement Radar transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Rosemount 148 Temperature Transmitter

Your needs are always on our Radar

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

U Series Non-Contact Ultrasonic Transmitter

Ultrasonic Liquid Level Transmitters

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

Ultrasonic level measuring device, non-contact

ULTRASONIC LEVEL METERS ULM 70

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Fisher 4200 Series Electronic Position Transmitters

MiniMe 2-Wire Ultrasonic Level Transmitter Model LU12/LU13/LU14 Owner s Manual

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Propagation of Electromagnetic Waves

MEAS CAL ALARM CONF APT2000 TC

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Kotron Series 82 CE. Level. Transmitter. Installation and Operating Manual

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

H O R I Z O N G U I D E D W A V E R A D A R

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Design and applications

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Positioner with HART Communication Type 3780

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

AUTOMATION. Operator s Manual. DCR-1005 and DCR Rev. A4, 10/08 Doc

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Installation and maintenance manual. LSU 100, Ultrasonic level transmitter

Transcription:

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow D E S C R I P T I O N Echotel Model 355 is a two-wire, loop-powered, noncontact ultrasonic transmitter that performs liquid level, volume, and open channel flow measurement. Model 355 Transmitters feature a powerful 60 khz ultrasonic transducer and advanced digital signal processing to reliably measure out to a 20 feet (6 m) maximum range. The Model 355 provides unsurpassed ease of configuration with either the menu-driven 4-push-button, 2-line 16-character display, HART digital communications, or PACTware. This enables a complete configuration to be performed via the local user interface, or remotely with the extra capability of capturing echo wave forms, and viewing trend data, diagnostic conditions, and all transmitter configuration parameters. The integral mount electronics are housed in either a cast aluminum housing or Lexan thermoplastic housing. The intelligent electronics analyze the ultrasonic echo profile, apply temperature compensation, reject echoes from false targets, and then processes the true echo from the liquid surface. This results in an extremely reliable measurement even when applications difficulties like turbulence, rapid level changes, or echoes from false targets exist. The 60 khz ultrasonic transducer is offered in polypropylene, or Kynar Flex for superior performance in harsh environments. These powerful transducers feature a 10 conical beam and 10" (250 mm) blocking distance to maximize measurement capabilities in a wide variety of applications. A P P L I C A T I O N S Chemical storage tanks Pond or river level monitoring Paint, ink and solvent tanks Industrial wastewater processing Volume in batch and day tanks Open channel flow weirs and flumes Cast aluminum housing with Kynar Flex transducer Lexan housing with polypropylene transducer F E A T U R E S Two-wire, loop-powered transmitter for level, volume and open channel flow measurement Maximum range of 20 feet (6 meters) PACTware PC program using HART Communications for remote configuration and troubleshooting Menu-driven 4-push-button, 2-line 16-character LCD user interface Patent-pending temperature compensated echo rejection technique identifies true echo from surface Two 7-digit flow totalizers, one resettable, and one non-resettable Common tank shapes and 20-point custom table for fast and accurate volume configuration 60 khz transducer with 10 beam angle and 10" (250 mm) blocking distance Dynamic baseline noise compensation provides reliable performance in the presence of electromagnetic noise Generic Discharge Flow Equation and 35 flume/weir primary elements for open channel flow applications

T E C H N O L O G Y Non-contact ultrasonic measurement is obtained by emitting an ultrasonic pulse from the transducer and measuring the time required for the echo to reflect from the liquid surface and return to the transducer. The Model 355 measures the time of the round trip pulse, and calculates the distance using the equation: D = V a T D = Distance to target 2 V a = Velocity of sound through air (1,128 ft/sec.) T = Time for one round trip sound pulse Since the speed of sound is temperature dependent, the transducer also measures the temperature at the transducer to provide compensation for changing air temperatures. Level is computed by the 355 electronics using the measured distance and the configuration data that has been entered for the vessel dimensions. By inputting the tank shape and 1-3 dimensions, the electronics can calculate the liquid volume in the vessel. In a similar operation, the Model 355 can perform open channel flow measurement by converting the level reading into units of volume per time. Common tank shapes, flumes and weirs are stored in the 355 software. A 20-point custom table is also available for unusual tanks or primary flow elements. Model 355 Blocking Distance Flow Distance (measured) Range Parshall Flume Level (range - distance) Level/Volume Application Open Channel Flow Application P E R F O R M A N C E Model 355 Transmitters are high performance units that feature a powerful 60 khz transducer, and advanced digital signal processing. These features allow the 355 to accurately track the liquid level in difficult applications like turbulence, rapid level changes or when echoes from false targets exist. The narrow 10 beam angle, shown on the right, allows the 355 to be used in applications where other units with wider beam angles fail due to false reflections from obstructions in the tank. Beam Radius (r) vs. Distance 2

M E A S U R E M E N T R A N G E C A L C U L A T I O N S Ultrasonic non-contact transmitters are typically rated for a maximum range in ideal conditions. Experience has shown that the maximum range must be reduced for certain factors. Although the maximum range rating is somewhat conservative, each application must be evaluated for specific conditions in the tank. Several application parameters that affect ultrasonic performance are shown in the tank at the right. Each of these parameters is assigned a Performance Multiplier in the chart below. Multiply the maximum potential range (20 feet) of the Model 355 by each of the applicable Performance Multipliers to calculate the maximum allowable range for the application. Beam spread interference Vapors Surface agitation Beam spread interference Foam PERFORMANCE OPERATiNg PARAMETER CONDiTiON MULTiPLiER SURFACE AgiTATiON: Surface agitation or waves can degrade the performance. Moderate agitation results in only slight degradation of performance. The worst case is when the surface is a good reflector, but in the wrong direction. Smooth, glass-like surface......................1.0 Slight agitation, choppiness.....................0.9 Heavy agitation...............................0.8 Slight vortex.................................0.7 VAPORS AND STEAM: Vapors can cause problems when the liquid process temperature is well above the temperature of the airspace. The greater the difference, the more expected vapor problems. The problems result from condensation or layering in the sound path, both of which attenuate the sound signal, and degrade performance. If a vent is used, be sure that it is well away from the transducer. BEAM SPREAD interference: It is recommended that no obstructions, such as ladder rungs, fill pipes, support struts, etc., be allowed within the 10 ultrasonic beam diameter. If an obstruction is unavoidable, make it as far away as possible from the transducer. Interference from agitator blades is only an intermittent interference that usually has little effect on performance. A special software algorithm can also help suppress false echoes from agitator blades that are within the beam angle. FOAM: Foam can attenuate the ultrasound and render the system inoperative. If possible, moving the transducer to an area in the tank where there is less foam will improve the performance. Thick, heavydensity foams can sometimes produce a reflection from the top of the foam. The multipliers shown at right are general guidelines. For further assistance consult the factory. No condensation..............................1.0 Little condensation............................0.9 Much condensation/ foggy appearance............0.8 No interference within 5 half beam angle..........1.0 Agitator at speed less than 60 RPM...............1.0 Agitator at speed greater than 60 RPM...Consult factory Interference outside 2, far from transducer (in bottom third of range)..............0.8 Interference outside 2, near to transducer (in top third of range).................0.5 No foam....................................1.0 Light froth, less than 0.25" thick..................0.8 Light foam, less than 0.5" thick..................0.5 Light foam, more than 1" thick...................0.1 EXAMPLE: A slightly agitated 12-foot tank with no condensation, no interference, and a light froth on the surface. Maximum allowable range: 20' 0.9 1.0 1.0 0.8 = 14.4 feet Since the maximum allowable range is 14.4 feet, the 355 is suitable for this 12-foot tank. NOTE: The multipliers shown above are general guidelines. For further assistance consult the factory. 3

L E V E L & V O L U M E A P P L I C A T I O N S The Echotel Model 355 Transmitter utilizes an advanced, patent-pending signal processing technology to provide excellent performance in difficult process conditions. Dynamic baseline noise compensation, temperature compensated echo rejection, and extensive self-diagnostics all combine to provide extremely reliable level and volume measurement. Temperature Compensated Echo Rejection Ultrasonic transmitters use temperature compensation to adjust for speed-of-sound changes throughout the operating temperature range of the transducer; however, most transmitters do not apply this compensation to their false target rejection scheme. This can result in unreliable level measurement when the temperature inside the tank changes, and the echo rejection profile contracts or expands. The Model 355 has a patent-pending echo rejection technique that constantly adjusts the rejected echo profile based on the current sound propagation velocity. This technique keeps the transmitter tracking the actual liquid level as opposed to false targets even when temperature changes alter the shape of the echo rejection profile. Dynamic Baseline Noise Compensation Electromagnetic and acoustical noise can adversely affect instrumentation by decreasing the signal-to-noise ratio, and degrading overall measurement performance. The Model 355 continuously monitors for the presence of excessive electrical noise. If noise levels are above a set limit, the electronics will dynamically adjust the baseline to compensate for the electrical interference. This dynamic baseline adjustment enables the 355 to keep tracking the proper echo even in the presence of excessive electrical noise. Stored Tank Shapes for Volume Volume configuration with the 355 is as easy as selecting the tank shape and inputting 1 3 dimensions. While a 20-point custom table is also available, selecting the actual tank shape provides for a fast and accurate configuration for a variety of common tanks shapes. O P E N C H A N N E L F L O W A P P L I C A T I O N S Q=K(L-CH)H n Model 355 Flow Parshall Flume Extensive Selection of Primary Flow Elements With a total of 35 flume and weir curves stored in the electronics, it would be hard to find an open channel flow application that cannot be handled by the 355 transmitter. Unusual flow applications can readily be accomplished through the use of either the 20-point Custom Table or the Generic Discharge Flow Equation which allows a direct entry of unique flow equations. Dual Flow Totalizers Two 7-digit flow totalizers are provided for recording flow in cubic feet, gallons, million gallons, liters, million liters, or cubic meters. One totalizer is resettable and the other is non-resettable. Several multipliers are selectable to allow for proper scaling. Totalizer time is also recorded to show how long each totalizer has been recording flow. 4

E L E C T R O N I C S S P E C I F I C A T I O N S Supply Voltage XP & GP 16 to 36 VDC IS 16 to 28.6 VDC Power Consumption Less than 1 Watt Warm-up Time 25 seconds Output Type 4 20 ma with optional HART digital signal Range 3.8 to 20.5 ma useable (NAMUR NE 43) Diagnostic Alarm Selectable from 3.6 ma, 22 ma or HOLD Damping Adjustable from 1 60 Loop Resistance 400 Ω @ 24 VDC/20 ma, 350 Ω @ 24 VDC/22 ma Digital Communication HART version 5.x compatible Display 2-line x 16-character LCD Keypad 4-push-button menu-driven Ambient Temperature -40 to +175 F (-40 to +80 C) Humidity O 99%, non-condensing Electromagnetic Compatibility Meets CE Requirements: EN 50081-2, EN 50082-2 Surge Protection Meets CE Requirements: EN 61326-1 (1,000 volts) Shock ISA-DS71.03, Paragraph 5.1.1, Table 2, Level SA1 Vibration ISA DS71.03, Paragraph 5.1.2, Table 1, Condition VC2 Housing Material Cast aluminum or Lexan Cable Entry Two ¾" NPT or M20 entries Net Weight Aluminum Housing 3.2 lbs (1.5 kg) Lexan Housing 1.6 lbs. (0.7 kg) intrinsically Safe Entity Parameters Ui 28.4 VDC 28 VDC Ii 94 ma 120 ma Pi 0.67 W 0.84 W Ci 5.5 nf Li 370 mh Ω 1200 1000 800 600 400 350 200 @ 20 ma (350 @ 22 ma) 36 V 1000 Ω 28.6 V 630 Ω General Purpose and Explosion Proof Intrinsically Safe 0 0 10 16 20 24 30 40 Supply VDC T R A N S D U C E R S P E C I F I C A T I O N S Maximum Range 20 feet (6 meters) Minimum Range 13 inches (330 mm) Blocking Distance 10 inches (250 mm) Minimum Measurement 3 inches (76 mm) Frequency 60 khz Process Connection 2" NPT Process Temperature -40º to +175º F (-40º to +80º C) Process Pressure 0 to 43.5 psig (0 to 3 bar) Material Kynar Flex (PVDF) or polypropylene Beam Angle 10º conical 5

P E R F O R M A N C E S P E C I F I C A T I O N S Accuracy Repeatability Resolution Linearity Response Time Greater of ± 0.2% of range or 0.24 inch (6 mm) ± 0.125 inch (± 3 mm) 0.1 inch (2.5 mm) ± 0.4 inch (± 10 mm) Less than 1 second (typical) Performance is based on a reference operating condition of an ambient temperature of +60º to +77º F (+15º to +25º C), 45 to 75% relative humidity, transducer vertically aligned over an ideal reflecting surface, and no false targets within the ultrasonic beam angle. A G E N C Y A P P R O V A L S AgENCY MODEL PROTECTiON METHOD AREA CLASSiFiCATiON United States 355-5X0A-11R Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D 355-5X0A-10R Type 4X, IP66, T4 @ 80 C Entity 355-5X0A-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D IP66/67 ➀, T4 @ 80 C Entity 355-5X0A-1XX Non-Incendive Class I, Div. 2; Groups A, B, C, & D IP66/67 ➀, T4 @ 80 C Canada 355-5X0A-11R Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D 355-5X0A-10R Type 4X, IP66, T4 @ 80 C Entity 355-5X0A-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D IP66/67 ➀, T4 @ 80 C Entity 355-5X0A-1XX Non-Incendive Class I, Div. 2; Groups A, B, C, & D IP66/67 ➀, T4 @ 80 C ATEX 355-5X0A-AXX Intrinsically Safe II 1 G Ex ia IIC T4 @ 70 C EN60079-0: 2006, ISSeP09ATEX013X EN60079-11: 2007, Ambient Temp: -40 to +70 C EN60079-26: 2007 355-5X0A-C0X Explosion Proof II 1/2 G Ex ma/d IIC T6 @ 70 C Ga/Gb 355-5X0A-C1X EN60079-1: 2007, ISSeP09ATEX009X EN60079-18: 2004, Ambient Temp: -40 to +70 C EN60079-26: 2007 BRAZiL 355-5X0A-AXX Intrinsically Safe BR-Ex ia IIC T4, IP66/IP67 ➀ ABNT NBR IEC 60079-0: 2006, Ambient Temp: -40 to +70 C ABNT NBR IEC 60079-11: 2009, AEX-12797-X ABNT NBR IEC 60529: 2005 inmetro/tüv 355-5X0A-C0X Explosion Proof BR-Ex d ma IIC T6 IP66 355-5X0A-C1X ABNT NBR IEC 60079-0:2006, Ambient Temp: -40 to +70 C ABNT NBR IEC 60079-1:2007, AEX-12647-X ABNT NBR IEC 60079-18:2007, ABNT NBR IEC 60529:2005 ➀ IP67 rating applies to Lexan housing only. For Division 2 the measured media inside vessel must be non-flammable only. The transmitter should be installed such that in the event of rare incidents, the aluminum enclosure cannot be an ignition source due to impact or friction, and that electrostatic discharges on plastic parts are prevented. These units have been tested to EN 61326 and are in compliance with the EMC Directive 2004/108/EC. 6

D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m ) 2.25 (57) 2.25 (57) 3.78 (96) 1.65 (42) 3.26 (83) 3.26 (83) 1.65 (42) M20 or 3 /4" NPT Conduit Opening 2" NPT 2" NPT 1.50 (38) 3.26 (83) 3.26 (83) 1.50 (38) 1.90 (48) Diameter 1.90 (48) Diameter Cast Aluminum Housing with Kynar or Polypropylene Transducer Lexan Housing with Kynar or Polypropylene Transducer M O D E L N U M B E R BASIC MODEL NUMBER 355 Ultrasonic transmitter for level, volume and open channel flow Quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). INPUT POWER 5 24 VDC two-wire loop-powered OUTPUT SIGNAL 0 4 20 ma without HART 1 4 20 ma with HART AGENCY APPROVALS 1 FM/FMc IS & Non-incendive A ATEX IS EEx ia C ATEX XP EEx d (only available with Housing codes 0 & 1, and Transducer code R) HOUSING/CONDUIT CONNECTION 0 Cast aluminum with ¾" NPT conduit connections 1 Cast aluminum with M20 conduit connections 6 Lexan plastic with ¾" NPT conduit connections 7 Lexan plastic with M20 conduit connections TRANSDUCER B 2" NPT polypropylene R 2" NPT Kynar Flex 3 5 5 5 0 A 7

Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. E S P Expedite Ship Plan The Echotel Model 355 Ultrasonic Level Transmitter is available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently color coded in the selection data charts. To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for eighteen months from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 705 Enterprise Street Aurora, Illinois 60504-8149 630-969-4000 Fax 630-969-9489 info@magnetrol.com www.magnetrol.com Copyright 2016 Magnetrol International, Incorporated. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol & Magnetrol logotype and Echotel are registered trademarks of Magnetrol International HART is a registered trademark of the HART Communication Foundation PACTware is trademark of PACTware Consortium Lexan is a registered trademark of Savic Innovative Plastics Kynar is a registered trademark of Arkema, Inc. BULLETiN: 51-161.1 EFFECTiVE: July 2012 SUPERSEDES: May 2009