PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

Similar documents
Narrow Pulse Measurements on Vector Network Analyzers

SPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS

A TURNKEY NEAR-FIELD MEASUREMENT SYSTEM FOR PULSE MODE APPLICATIONS

Antenna and RCS Measurement Configurations Using Agilent s New PNA Network Analyzers

Agilent Antenna and RCS Measurement Configurations Using PNA Microwave Network Analyzers. White Paper

MAKING TRANSIENT ANTENNA MEASUREMENTS

Keysight Technologies PNA Receiver Reduces Antenna/RCS Measurement Test Times

Advances in Antenna Measurement Instrumentation and Systems

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

DIGITAL BEAM-FORMING ANTENNA RANGE

Advanced Waveform Generator For Integrated Phased Array Testing

ANECHOIC CHAMBER EVALUATION

Advanced Waveform Generator For Integrated Phased Array Testing

Advanced Digital Receiver

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers

Agilent PNA Microwave Network Analyzers

PROBE CORRECTION EFFECTS ON PLANAR, CYLINDRICAL AND SPHERICAL NEAR-FIELD MEASUREMENTS

MISSION TO MARS - IN SEARCH OF ANTENNA PATTERN CRATERS

APPLICATIONS OF PORTABLE NEAR-FIELD ANTENNA MEASUREMENT SYSTEMS

RAYTHEON 23 x 22 50GHZ PULSE SYSTEM

REFLECTION SUPPRESSION IN LARGE SPHERICAL NEAR-FIELD RANGE

Sub-millimeter Wave Planar Near-field Antenna Testing

IMPROVING AND EXTENDING THE MARS TECHNIQUE TO REDUCE SCATTERING ERRORS

Keysight Technologies PNA-X Series Microwave Network Analyzers

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

A HILBERT TRANSFORM BASED RECEIVER POST PROCESSOR

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna

Pulsed VNA Measurements:

Keysight Technologies Accurate Pulsed Measurements with the PNA Microwave Network Analyzers. Application Note

ALIGNMENT SENSITIVITY AND CORRECTION METHODS FOR MILLIMETER- WAVE SPHERICAL NEAR-FIELD MEASUREMENTS

A COMPOSITE NEAR-FIELD SCANNING ANTENNA RANGE FOR MILLIMETER-WAVE BANDS

A CYLINDRICAL NEAR-FIELD VS. SPHERICAL NEAR-FIELD ANTENNA TEST COMPARISON

Accurate Planar Near-Field Results Without Full Anechoic Chamber

33 BY 16 NEAR-FIELD MEASUREMENT SYSTEM

IMPLEMENTATION OF BACK PROJECTION ON A SPHERICAL NEAR- FIELD RANGE

HOW TO CHOOSE AN ANTENNA RANGE CONFIGURATION

Upgraded Planar Near-Field Test Range For Large Space Flight Reflector Antennas Testing from L to Ku-Band

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements

ELEC RADAR FRONT-END SUMMARY

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Using an Arbitrary Waveform Generator for Threat Generation

Model 855 RF / Microwave Signal Generator

Pulsed Measurement Capability of Copper Mountain Technologies VNAs

Model 865-M Wideband Synthesizer

Pulse Timing and Latency Measurements Using Wideband Video Detectors

Model 865-M Wideband Synthesizer

WIESON TECHNOLOGIES CO., LTD.

Structural Correction of a Spherical Near-Field Scanner for mm-wave Applications

METHODS TO ESTIMATE AND REDUCE LEAKAGE BIAS ERRORS IN PLANAR NEAR-FIELD ANTENNA MEASUREMENTS

SPHERICAL NEAR-FIELD MEASUREMENTS AT UHF FREQUENCIES WITH COMPLETE UNCERTAINTY ANALYSIS

> StarLab. Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing

Potential interference from spaceborne active sensors into radionavigation-satellite service receivers in the MHz band

Millimetre Spherical Wave Antenna Pattern Measurements at NPL. Philip Miller May 2009

An introduction to Mobile Station Over-the-Air measurements

T- DualScan. StarLab

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

Antenna Measurement Uncertainty Method for Measurements in Compact Antenna Test Ranges

Estimating Measurement Uncertainties in Compact Range Antenna Measurements

Model 845-M Low Noise Synthesizer

Signals and Systems Lecture 9 Communication Systems Frequency-Division Multiplexing and Frequency Modulation (FM)

MEASUREMENT OF THE EARTH-OBSERVER-1 SATELLITE X-BAND PHASED ARRAY

Chapter 5. Array of Star Spirals

TRADITIONAL ANTENNA MEASUREMENTS AND CTIA OTA MEASUREMENTS MERGING THE TECHNOLOGIES

Exercise 2-2. Antenna Driving System EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

PN9000 PULSED CARRIER MEASUREMENTS

ADVANTAGES AND DISADVANTAGES OF VARIOUS HEMISPHERICAL SCANNING TECHNIQUES

Agilent PNA Microwave Network Analyzers

Exercise 1-3. Radar Antennas EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS. Antenna types

A BROADBAND POLARIZATION SELECTABLE FEED FOR COMPACT RANGE APPLICATIONS

Exercise 2-6. Target Bearing Estimation EXERCISE OBJECTIVE

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

APPENDIX B. 4. DEFINITIONS, SYMBOLS AND ABBREVIATIONS For the purposes of the present document, the following terms and definitions apply.

Agilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

The Discussion of this exercise covers the following points:

System configurations. Main features. I TScan SOLUTION FOR

Antenna Measurement using Vector Network Analyzer. Jong-hwan Keum Agilent Technologies

A compact and versatile test solution that accurately simulates real life

A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER

Power Measurement Basics

Measurement of Digital Transmission Systems Operating under Section March 23, 2005

APPLICATION NOTE 3942 Optimize the Buffer Amplifier/ADC Connection

Evaluation of Millimeter wave Radar using Stepped Multiple Frequency Complementary Phase Code modulation

Set No.1. Code No: R

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-M Specification 1.8 BNC

Developing a Generic Software-Defined Radar Transmitter using GNU Radio

GUIDED WEAPONS RADAR TESTING

Fast and Accurate RF component characterization enabled by FPGA technology

Near-Field Antenna Measurements using a Lithium Niobate Photonic Probe

Agilent Technologies Gli analizzatori di reti della serie-x

The CReSIS Anechoic Chamber is located at: The University of Kansas. M2SEC building W 15 th St. Lawrence, KS

Lecture 9. Radar Equation. Dr. Aamer Iqbal. Radar Signal Processing Dr. Aamer Iqbal Bhatti

Agilent 6800 Series AC Power Source/Analyzer

Model 310H Fast 800V Pulse Generator

Characterization of a Photonics E-Field Sensor as a Near-Field Probe

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Comparison of Two Detection Combination Algorithms for Phased Array Radars

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

Transcription:

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS David S. Fooshe Nearfield Systems Inc., 19730 Magellan Drive Torrance, CA 90502 USA ABSTRACT Previous AMTA papers have discussed pulsed antenna measurements and the importance of parameters such as pulse width, pulse repetition frequency (PRF) and receiver dynamic range in determining the appropriate technique for performing pulsed measurements. Typically, the pulse width and PRF determine the IF bandwidth required of the instrumentation receiver to achieve a specific level of receiver performance. Less emphasis has been given to the receiver timing and synchronization required to achieve optimum performance for a full pulsed antenna measurement scenario. This paper will discuss receiver timing considerations and show examples of scan time performance during highspeed pulsed measurements. Inter-pulse and intra-pulse measurements will be compared with respect to their impact on measurement time. Pulse profile measurements will be examined to show the importance of a fast synchronous receiver for sub-microsecond pulse characterization. Pulsed antenna pattern results will also be presented and compared with CW measurements. Keywords: pulsed antenna measurements, pulse width, PRF, instrumentation receiver, phased array, IF bandwidth. 1.0 Introduction This paper discusses performance considerations involved in making near-field antenna measurements using a microwave receiver operating in pulse mode. Pulsed operation can affect the performance of an antenna measurement in several ways; therefore, attention must be paid to the choice of receiver and measurement technique. Previous papers [1] [2] [4] described narrowband pulse measurements and how the dynamic range decreases with increased pulse repetition interval (PRI). In a narrowband system, the receiver is not synchronized to the pulse and must average over an adequate number of pulses in order to detect the desired CW component. Since narrowband receiver operation requires no synchronization to the pulse, less control over the measurement process is available. For this reason, only wideband synchronous pulse mode operation is considered in this paper. In a wideband system, the receiver is synchronized to the pulse and must wait for the RF pulse in order to make a measurement. This delay can affect the measurement and must be taken into consideration when planning the test. In a wideband pulsed system dynamic range is limited by the pulse width, but not affected by the PRF. To maximize the measurement efficiency, the receiver integration period should be equal to or less than the desired pulse width for the measurement. A primary consideration when designing a measurement system for pulsed antenna measurements is the synchronization of the system with the RF pulse. Radar systems are designed for rapid transition between transmit and receive states often switching from a high power output to high sensitivity input. Testing the radar antenna as a separate subsystem without the transmit/receive electronics presents a unique challenge to the antenna measurement system. The measurement system must be capable of simulating the control and timing of the radar system in a manner that provides a realistic test of the antenna while maintaining control over the measurement process. As an example, radar systems often require an advance pulse to arm or turn-on the amplifiers and electronics prior to the transmission of the RF pulse. If the antenna-under-test (AUT) is an active antenna, then this arm pulse must be generated by the measurement system in the proper sequence with the RF pulse. Similarly, an active antenna may require a beam-steering computer (BSC) to compute the phase for each element in order to properly steer the beam. The computation is typically done in real-time during the measurement process and is often initiated by the measurement computer or beam controller. In order to provide the resources necessary to address the demands of pulsed antenna measurements, the measurement system should include a high-speed receiver with wideband IF inputs, be capable of synchronous triggered measurements and allow the flexibility to increase integration time for increased signal-to-noise performance. The system should also include a high-

speed beam controller capable of being synchronized to the scanner or positioner while providing a wide range of control over various devices and instruments used during the measurement process, including frequency synthesizers, high-speed PIN switches, beam-steering computers and pulse generators. For pulsed antenna measurements, the beam-controller should also be capable of synchronizing the receiver and the RF pulse. This paper will review receiver pulse parameters and performance, discuss pulsed near-field considerations including pulse synchronization, pulse timing vs. scan speed, positional accuracy in pulse mode, and intra-pulse averaging. Pulse profile measurements will be discussed and a comparison of CW and pulse measurements will be presented. 2.0 Pulse Parameters and Performance A convenient means of evaluating receiver pulse performance is the pulse performance diagram. The pulse performance diagram shows PRF as a function of pulse width and outlines the allowable regions of operation for the receiver. The lower region where pulse width is greater than PRI is, of course, CW. Operation with pulse widths greater than the receiver settling time is considered to fall within the full pulse performance region of operation, as shown in Figure 1. This is the desired region of operation for a synchronous wideband receiver. The older Panther 6000 receiver [3] has been tested over a variety of pulse parameters and exhibits full Signal/Noise performance with a minimum pulse width of 7 µs with a pulse trigger delay of no less than 2 µs. Pulse Repition Frequency (PRF) Pulse Period (PRI) The newer Panther 9000 receiver [5] with its faster integration time has expanded regions for peak response and full performance allowing full performance measurements of pulses less than 1 microsecond. Pulse Repition Frequency (PRF) 100 Hz 1 khz 10 khz 100 khz 1 MHz 10 MHz 10 MHz 10 ms 1 ms 100 us 10 us 1 us 0.64 us 320 ns 100 ns 10 ns Peak Response Region High PRF Region Full Performance Pulse Region CW Region 10 ns 100 ns 1 us 10 us 100 us 1 ms Pulse Width (PW) Figure 2 Panther 9000 Pulse Performance Diagram Once the receiver operating region has been determined, system timing and synchronization must be evaluated. These will be considered for near-field measurements in the following sections. 3.0 Pulsed Near-field Measurements CW near-field measurements [6] are well-understood and have been extensively covered in the literature. Pulsed near-field antenna measurements require the same level of understanding as CW, but with a few additional considerations, including the following. Pulse synchronization and timing must be considered when choosing a receiver for pulsed measurements. The near-field scan speed may need to be reduced to match the pulse rate, possibly increasing the overall test time. Positional accuracy may be affected by the pulse timing. A comparison test can be made to check for this. Intra-pulse averaging may be needed to maximize the receiver utilization and possibly reduce the test time. Figure 1 Panther 6000 Pulse Performance Diagram

3.1 Pulse Synchronization Pulsed near-field measurements require synchronization between the pulse and the measurement system. Figure 3 shows a typical scope trace of signals in a pulsed measurement. receiver is active during the entire measurement time, averaging continuously (in CW mode) until the measurement time ends. In the Panther 9000, a "receiver window" signal tells the receiver when to start and stop a measurement, to a quantizing accuracy of 10 ns. Unlike the Panther 6000 in which software timing loops could produce several microseconds of jitter, the Panther 9000 with its hardware synchronization exhibits no such jitter. Receiver timing jitter is an important consideration for pulsed measurements and determines the accuracy to which the receiver can be triggered relative to the leading edge of the pulse. 3.2 Pulse Timing vs. Scan Speed Figure 3 Pulse Timing - Simple In Figure 3, Trace 1 is the 20 khz PRF pulse (50 us PRI) with 10 µs pulse width, Trace 2 is the CW IF signal into reference channel A, Trace 3 is the pulsed IF signal into test channel B, Trace 4 is the receiver trigger or gate signal, delayed by about 5 µs from leading edge of pulse. Complex multi-frequency, multi-beam pulsed near-field measurements require synchronization of the scanner or positioner, beam controller and receiver with the pulse to insure accurate measurements. To manage the measurement process, the NSI2000 antenna measurement software s beam table is used to specify the parameters to be measured between major position triggers. A major position trigger is generated by the motion controller, typically at one-half lambda spacing, i.e. for planar near-field measurements. Both the Panther 6000 and Panther 9000 receivers use the beam table to specify timing. A beam is defined as a single parameter, i.e. frequency, port, beam-steer, etc, to be measured. Each beam has two timing parameters: dwell time, and measurement time. The dwell time initiates the beam. During dwell time the system is being prepared for an impending measurement by setting the states of switches, frequency sources, etc. At the end of the dwell time, the measurement time begins. The In a pulsed system the scan speed is required to accommodate the pulse rate so that all beams may be measured between position triggers, typically ½ lambda apart. Relevant factors to consider include the frequency of operation, scan speed, receiver speed and the number of frequencies and beams to be measured. For an X-band system with ½ lambda spacing of approximately 0.5 inch, a 20 inch per second (ips) scan speed requires 0.029 seconds between major position triggers. All measurements for all beams and pulses must be completed within this time. Assuming a PRF of 10 khz and receiver averaging of 10 pulses to meet dynamic range requirements, approximately 28 beams may be measured in the allotted ½ lambda interval. Measurement Time (ms) 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 Pulsed Measurement Time vs No. Beams (PRF = 10 KHz, Scan speed = 20 ips) 1 4 8 12 16 20 24 28 32 34 38 42 44 48 52 56 60 64 No. Beams Pos Trig Time Meas Time Figure 4 Measurement Time vs. No. of Beams (PRF=10 khz, scan speed = 20 ips) If the PRF is increased to 20 khz, the number of possible beams is increased by x2. Slowing the scan speed from 20 ips to 10 ips also results in doubling the number of possible beams, but for a different reason. In this case, the ½ lambda time has doubled, as shown in Figure 5, allowing twice the time for multi-beam measurements.

Pulsed Measurement Time vs No. Beams (PRF = 10 khz, Scan speed = 10 ips) Far-field amplitude of Pulse_Repeat09.nsi Contin Motion Co Stop Motion Co 70.0 0 Contin Motion Cr Stop Motion Cr Measurement Time (ms) 60.0 50.0 40.0 30.0 20.0 10.0 0.0 1 4 8 12 16 20 24 28 32 34 38 42 44 48 52 56 60 64 No. Beams Pos Trig Time Meas Time Amplitude (db) -5-10 -15-20 -25-30 -35 Figure 5 Measurement Time vs. No. of Beams (PRF=10 khz, Scan speed = 10 ips) The above examples are simplified to illustrate the affect of changing one or two parameters. Pulsed measurement complexity must be managed, however, when considering the full range of possible parameters including scan speed, RF frequency, PRF, pulse width, receiver speed, receiver averaging, dynamic range, etc. For multifrequency pulsed measurements, the RF source speed may also be a factor if the source switching time is a significant percentage of the PRI. In this case, extra pulses must be considered for the source settling time resulting in fewer beams possible. 3.3 Positional Accuracy in Pulse Mode Pulsed RF tests are subject to a probe positional uncertainty due to the fact that the receiver trigger signal must be delayed to be synchronized with the pulse modulation signal. This effect is commonly referred to as pulse jitter. Note that this is a different form of jitter from that discussed earlier. To assess the impact of this pulse jitter on measurement accuracy a continuous motion data acquisition (which will suffer from this effect) and a stop motion data acquisition (where there is no probe positional uncertainty) can be compared. In Figure 6 these two cases are compared and these results demonstrate the negligible effect of pulse jitter in this case. Note that the error depicted here is due to both repeatability and pulse jitter. The case shown is for a Y- axis scanning speed of 4 ips (0.1 m/s), a PRF of 3.33 khz, 7 discrete frequencies, 2 probe polarizations and 2 AUT ports. A lower PRF may lead to higher error levels and in such a case the scan speed may have to be reduced. -40-45 -50-40 -30-20 -10 0 10 20 30 40 Elevation (deg) Figure 6 Positional Accuracy Comparison 3.4 Intra-Pulse Averaging Intra-pulse averaging is a capability that allows the receiver to perform averaging within a pulse. Prior to the introduction of this feature, the Panther 6000 receiver acquired a single 3.55 µs sample per pulse. A single receiver measurement using a specified number of receiver averages required an equivalent number of pulses to be acquired. This resulted in receiver measurement times that were highly dependent on the PRF and inefficient in the cases of large pulse widths. With the intra-pulse averaging feature, multiple receiver samples may be collected within a single RF pulse to provide an increase in receiver measurement speed performance for cases where the RF pulse length is 10 µs or greater. With intra-pulse averaging the measurement may still require multiple pulses, but fewer will be needed to complete the measurement. Figure 7 Pulse Timing (No Intra-Pulse Averaging)

Figure 8 Pulse Timing (Intra-Pulse Averaging) Note that in Figure 8 with intra-pulse averaging, fewer pulses are required to complete the measurement, i.e. before next position trigger (Pos #2). 4.0 Pulse Profile Often pulse profile measurements are required in order to characterize the antenna or to better understand the pulse performance of the antenna system. By varying the trigger delay of the receiver, a pulse profile plot may be generated. A fast synchronous receiver is needed for accurate pulse profile measurements. Figure 9 shows a pulse profile measurement of a 10 microsecond pulse using the Panther 9100 receiver. Amplitude (db) 10 0-10 -20-30 -40-50 -60-70 -80 pulse profile -90-5 0 5 10 15 20 25 30 35 40 45 Trigger Delay (µs) Figure 9 Panther 9100 Pulse Profile Measurement 5.0 CW vs. Pulsed Comparison To verify the timing accuracy of a pulsed antenna measurement, it is often useful to compare pulsed and CW measurements. If an active antenna is used, CW measurements are not always possible, in which case a passive antenna should be considered to compare pulsed and CW measurements and validate the beam and pulse timing. Once the measurement system is validated with the passive antenna, the active AUT testing may begin. Figure 10 shows good comparison between CW and three different pulsed measurements. An actual measurement was made on a gain horn using a spherical near-field scanner in the NSI booth at AMTA 2007. The demo system included the Panther 9100 receiver with 100 averages, the Panther 9020 sources switching 100 frequencies and 2 polarizations with a high-speed PIN switch. A 20 khz PRF pulsed antenna measurement was performed using intra-pulse averaging with the following pulse widths. CW Pulsed, 10 µs pulse width Pulsed, 5 µs pulse width Pulsed, 2 µs pulse width The plot in Figure 10 shows an overlay comparison of far-field azimuth cuts of the four scans. Amplitude (db) 0-5 -10-15 -20-25 -30-35 -40-45 -50-55 -60 FF H-Cut CW07 CW Pulsed 10 us Pulsed 5 us Pulsed 2 us -75-50 -25 0 25 50 75 Azimuth (deg) Figure 10 Pulse vs. CW Comparison 6.0 Summary This paper has presented timing and performance considerations for high-speed pulsed antenna measurements including scan time considerations for near-field measurements, inter-pulse and intra-pulse comparisons, pulse profile measurements and a comparison between CW and pulsed antenna measurements. Emphasis was given to wideband synchronous pulse measurements, since this mode of operation provides the best opportunity for optimizing the performance of the pulsed measurement. Examples were provided to illustrate the importance of a fast

synchronous receiver and a versatile beam controller for high performance pulsed antenna measurements. The author would like to thank Bruce Williams, Bert Schluper, Dan Slater and Greg Hindman for their contribution to concepts presented in this paper. 7.0 References [1] J. Swanstrom, R. Shoulders, Pulsed Antenna Measurements With the HP 8530A Microwave Receiver, AMTA Proceedings 1994. [2] C. Barnett, D. Dunn, Practical Considerations for Making Pulsed Antenna Measurements, AMTA Proceedings 1997. [3] D. Fooshe, D. Slater, Digital Receiver Technology for High-Speed Near-field Antenna Measurements, AMTA Proceedings 1999. [4] R. Shoulders, C. Chi, Pulsed Antenna Measurements With the Agilent PNA Microwave Network Analyzer, AMTA Proceedings 2003. [5] D. Slater, Next Generation Phase Coherent Microwave Instrumentation Receiver, AMTA Proceedings 2007 [6] D. Slater, Near-field Antenna Measurements, p. 63, Artech House, Norwood, MA, 1991