UL Online Certifications Directory

Similar documents
UOXX.S3403 Control Unit Accessories, System. Control Unit Accessories, System

VNIV.EX454 - Sprinklers, Automatic and Open. Sprinklers, Automatic and Open

BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

ROHS DECLARATION OF CONFORMITY

QIJQ2.E Connectors for Use in Photovoltaic Systems - Component. Connectors for Use in Photovoltaic Systems - Component

UL Construction No. 254

UNA-CLAD Metal Roof Systems

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

Construction No. 90. Construction No. 90

WOODSTART STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Inclined Roof System Trimoterm SNV

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

PROJECT INSTRUCTIONS Roofing

SECTION ASPHALT SHINGLES

Perimeter Edge Metal Brochure (COMGN296) Updated: 7/18

HERE ARE YOUR BASIC ROOFING OPTIONS

TABLE OF CONTENTS A. PBR

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

Thermoplastic Mechanically Fastened Roofing Systems Induction Welding (RhinoBond / Isoweld) Attachment Method. Attachment I

HOW TO Fix Onduline Corrugated Bitumen Sheets

SECTION CABLE TRAYS

Installation Instructions for Panel Siding and Soffit

4 x 2.2 m SLEEPING BARREL. health, beauty, peace of mind SPECIFICATIONS WINDOWS ROOF SHINGLES TRANSPORTATION MAINTENANCE

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

Harmony Castings, LLC TPi Arcade, INC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

RED DIAMOND SHINGLES Roof Installation Introduction:

INCLINED ROOF SYSTEM TRIMOTERM SNV

ENDUREED VIVA SERIES Specifications

Performance Enhancing Nano Coatings: Changing the Rules of Stencil Design. Tony Lentz

Item 550 Chain Link Fence

Code Compliance Research Report CCRR-0155

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

The available roof cover choices are listed below: Fiberglass, Translucent Panels Steel. Shingles, Asphalt/Fiberglass, Irregular Pattern

ROOFING City of Grand Rapids Building Safety Division

Paraguard Roof Perimeter Systems ANSI/SPRI ES-1 Test Reports UL. Classified Products

1. ASME A Scheme for the Identification of Piping Systems.

SECTION ASPHALT SHINGLES

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Folding sliding doors

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

eco-shake INSTALLATION INSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

PRINTING & STRIPPING BLANKETS

Installation Instructions for TruWood Reversible Trim

**************************************************************************************************

Investment Opportunity

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Bar supports. Bar supports

Airflow: up to 28 CFM, 3000 Pa Air Pressure

KS42 MF SERIES - HORIZONTAL INSTALLATION

WOOD FAQ COVERS THESE QUESTIONS

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Series 9000 Vinyl Fixed Window

COPALUM Terminals and Splices (For Solid & Stranded Aluminum or Copper Wire)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF EVALUATION SUBJECT:

Frabo, environmentally friendly innovation

SmartCleat. Cable Cleats and Ties: SMARTCLEAT TREFOIL AND SINGLE from 25 to 99 mm cable. SmartCleat Trefoil CABLE TIES SMART SECURE PLATE

ACCESSORIES ACCESSORIES ACCESSORIES FASTENERS & TOOLS NAME PLATES PLASTIC ANGLES & COVERS BOARDS & SHEETS ADJUSTER METAL JOINTS PIPES PLASTIC JOINTS

Corresponds to breaker size current value. Contributing to space saving by selecting an appropriate size

The better way to build TM. Installation Manual ROOF SIPs

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

FOCUSING ON FASTENERS

1.01 NOTICE TO BIDDERS

B. Related Sections: The following Sections contain requirements that relate to this Section:

CAMBRIDGE 50 AR, 40, 30 AR & 30. Shingle color shown is Cambridge NW Harvard Slate. SUMAS / CALGARY

MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM

SECTION SWINGING AUTOMATIC ENTRANCES

Cast iron floor drain body with 8 round, adjustable cast iron top, trap primer tapping and plug

Construction Concerns: Roofing Materials

SECTION WOOD SHINGLES

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

Series 9000 Vinyl Fixed Window

Herman s offers the largest selection of Timberline shingles in Canada, with an impressive 25 colours & styles in stock! Lifetime Roofing System

DEKFAST COMMERCIAL ROOFING FASTENERS

INFITTING & OVERLAP HINGED DOORS

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

Construction Specification for Watermain and Water Service Tracer Wire

Designer Shingle BranDS. High Wind And Impact Resistant Shingles. High Wind And Impact Resistant Shingles


ATI Evaluation Service A Division of Architectural Testing Certification Services

UL TEST REPORT AND PROCEDURE

SECTION BULLET- RESISTANT DOORS

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

TECHNICAL BULLETIN 28

CLD-DS57 Rev 2B. Product family data sheet

European Technical Assessment. ETA-08/0285 of General Part. Technical Assessment Body issuing the ETA:

Innovation Through Science and Art TM

Transcription:

UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R27358 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems PROGRESSIVE MATERIALS L L C 540 CENTRAL CT NEW ALBANY, IN 47150 USA R27358 SPRAY APPLIED FOAM AND COATING SYSTEMS The "SF 4228" and "SF 4230" spray applied foam plastic insulations are 2.8 and 3.0 densities respectively. Class A 1. Deck: NC Incline: 1-1/2 Foam: Dow Chemical "Voracor CY 3053", any thickness. Base Coat: "LS 2200 series", 1-1/2 gal/sq. Top Coat: "LS 2200 series", 1-1/2 gal/sq. Surfacing: Granules at 35 lb/sq. 2. Deck: NC Incline: 1-1/2 Foam: BASF "81272", any thickness. Base Coat: "LS 2200 series", 1-1/2 gal/sq. Top Coat: "LS 2200 series", 1-1/2 gal/sq. Surfacing: Granules at 35 lb/sq. 3. Deck: NC Incline: 1-1/2 Foam: "SF 4028", max. 3-1/4 in.

4. Deck: NC Incline: 1/4 Foam: "SF 4028", max. 3-1/4 in. Surfacing: Granules at 60 lb/sq. 5. Deck: NC Incline: 1/4 Foam: "SF 4028", max. 3-1/4 in. Top Coat: "LS 2200 series", 1 gal/sq. 6. Deck: NC Incline: 1 Foam: "SF 4028", max. 3-1/4 in. Intermediate Coat: "LS 2200 series", 3/4 gal/sq. Top Coat: "LS 2200 series", 1 gal/sq. 7. Deck: NC Incline: 1-1/2 Foam: "SF 4128", max. 3-1/4 in. 8. Deck: NC Incline: 1/4 Foam: "SF 4128", max. 3-1/4 in. Surfacing: Granules at 60 lb/sq. 9. Deck: NC Incline: 1/4 Foam: "SF 4128", max. 3-1/4 in. Top Coat: "LS 2200 series", 1 gal/sq. 10. Deck: NC Incline: 1 Foam: "SF 4128", max. 3-1/4 in. Intermediate Coat: "LS 2200 series", 3/4 gal/sq. Top Coat: "LS 2200 series", 1 gal/sq. 11. Deck: NC Incline: 2 Foam: "SF 4028" or "SF 4128", 3-1/4 in. max. Base Coat: "HS 3300 series", 2 gal/sq. Intermediate Coat: "LS 2200 series", 1-1/2 gal/sq. Top Coat: "LS 2200 series", 1-1/2 gal/sq.

Surfacing: Granules at 60 lb/sq. 12. Deck: NC Incline: 1 Foam: "SF 4028" or "SF 4128", 3-1/4 in. max. Base Coat: "HS 3300 series", 1 gal/sq. Top Coat: "LS 2200 series", 1 gal/sq 13. Deck: NC Incline: 2 Foam: "SF 4028" or "SF 4128", 3-1/4 in. max. Base Coat: "HS 3300 series", 1-1/2 gal/sq. Top Coat: "LS 2200 series", 1 to 1-1/2 gal/sq. 14. Deck: NC Incline: 1 Foam: "SF 4028" or "SF 4128", 3 in. max. Base Coat: "HS 3300 series", 1 gal/sq. Top Coat: "HS 3200 series", 1 gal/sq. 15. Deck: NC Incline: 1 Foam: "SF 4028" or "SF 4128", 3 in. max. Base Coat: "HS 3300 series", 1 gal/sq. Top Coat: "HS 3300 series", 1 gal/sq. 16. Deck: NC Incline: 3 Foam: "SF 4228" or "SF 4230" applied any thickness. Base/Top Coat: United Coatings "Diathon", at 3 gal/sq. Surfacing: Granules at 30 lbs/sq. 17. Deck: NC Incline: 3 Coating: Two coats National Polymers "NP852" at 1-1/2 gal/sq/coat. Surfacing: No.11 roofing granules at # 30 lb/sq. 18. Deck: NC Incline: 3 Coating: General Electric "SCM3400 Series" at 3 gal/sq. Surfacing: No.11 roofing granules at # 30 lb/sq. 19. Deck: NC Incline: 3 Coating: LaPolla"TF 1000" or "TF 750" applied at 3 gal/sq. Surfacing: No. 11 ceramic coated roofing granules, 30 lb/sq. 20. Deck: NC Incline: 2 Base Coat: United "Elastuff 101" or "FE Coat 2000 Series Base Coat" at 2 gal/sq/coat. Top Coat: United "Elastuff 102" or "FE Coat 2000 Series Top Coat" at 2 gal/sq/coat. 21. Deck: NC Incline: 1/2

Coating: Volatile Free "VFI-540FR Aluminum" or "VFI-540FR Copper" at 2-1/2 gal/sq. (40 mil) 22. Deck: NC Incline: 1/2 Base Coat: Two coats Neogard "7419", 1-1/2-2 gal/sq total both coats. Surfacing: Neogard "70611", 1 gal/sq. 23. Deck: NC Incline: 2-1/2 Base Coat: "Elastocoat S-5000 Series" or Neogard 7860.01 at 1-1/2 gal/sq. Top Coat: "Elastocoat S-5000 Series" or Neogard 7860.01 at 1-1/2 gal/sq. 24. Deck: NC Incline: 1/2 Base Coat: Neogard 70620 at 2 gal/sq. Top Coat: Neogard 70611 at 1 gal/sq. 25. Deck: NC Incline: 2 Base Coat: LaPolla TF1000 at 1-1/2 gal/sq. Top Coat: LaPolla TF1000 at 1-1/2 gal/sq. 26. Deck: NC Incline: 2-1/2 Foam: "SF 4228" or "SF 4230", 4 in. Base Coat: Two coats General Electric "SCM 3300 Series", at 1-1/2 gal/sq/coat. 27. Deck: NC Incline: 2 Base/Top Coat: United Coatings "Diathon", at 3 gal/sq. 28. Deck: NC Incline: 2 Coating: Two coats National Polymers "NP852" at 1-1/2 gal/sq/coat. 29. Deck: NC Incline: 2-1/2 Coating: General Electric "SCM3400 Series" at 3 gal/sq. 30. Deck: NC Incline: 1-1/2 Surfacing: Granules at 35 lb/sq. 31. Deck: NC Incline: 1-1/2 Foam: BASF "FE348 Series", "ELASTOSPRAY 81255," "81275," "81285," "81305," or "81325", any thickness. Surfacing: Granules at 35 lb/sq. 32. Deck: NC Incline: 3-1/2 Foam: Premium Spray Products "Premiseal 250, 280 or 300", any thickness.

33. Deck: NC Incline: Unlimited Foam: Premium Spray Products "Premiseal 250, 280 or 300", any thickness. Surfacing: Granules at 35 lbs./sq. 34. Deck: NC Incline: 3-1/2 Foam: Premium Spray Products "Premiseal 250, 280 or 300", any thickness. 35. Deck: NC Incline: Unlimited Foam: Premium Spray Products "Premiseal 250, 280 or 300", any thickness. Surfacing: Granules at 35 lbs/sq. 36. Deck: NC Incline: Unlimited Foam: Bayer Material Science LLC "S245-25/30," "Bayseal 2.5," "Bayseal 2.7," or "Bayseal 3.0" (product designation may be suffixed by "F," "S," "SS," "FW," or "W"), any thickness. Surfacing: Granules at 35 lbs./sq. 37. Deck: NC Incline: Unlimited Foam: Bayer Material Science LLC \`S245-25/30,\' "Bayseal 2.5," "Bayseal 2.7," or "Bayseal 3.0" (product designation may be suffixed by "F," "S," "SS," "FW," or "W"), any thickness. Surfacing: Granules at 35 lbs/sq. 38. Deck: NC Incline: Unlimited Foam: Lapolla Industries Inc "LPA2500", "LPA2800", "LPA3000","LPA2500", "LPA2800" or "LPA3000", any thickness. Surfacing: Granules at 35 lbs./sq. 39. Deck: NC Incline: 4 Foam: Lapolla Industries Inc "LPA2500", "LPA2800", "LPA3000","LPA2500", "LPA2800" or "LPA3000", any thickness. Surfacing: Granules at 35 lbs/sq. 40. Deck: NC Incline: Unlimited Foam: BASF Corp. "FE348-2.8", any thickness.

Base Coat: "LS2200 series" at 1-1/4 gal/sq. Top Coat: "LS2200 series" at 1-1/4 gal/sq. 41. Deck: NC Incline: 4 Foam: BASF Corp. "FE348-2.8", any thickness. Base Coat: "HS3200 series" at 1 gal/sq. Top Coat: "HS3200 series" at 1 gal/sq. 42. Deck: NC Incline: Unlimited Foam: "SF 4228", any thickness. Base Coat: "LS2200 series" at 1-1/4 gal/sq. Top Coat: "LS2200 series" at 1-1/4 gal/sq. 43. Deck: NC Incline: 4 Foam: "SF 4228", any thickness. Base Coat: "HS3200 series" at 1 gal/sq. Top Coat: "HS3200 series" at 1 gal/sq. Class B 1. Deck: C-15/32 Incline: 1/2 Foam: "SF 4228" or "SF 4230", 1 in. min. Base Coat: United Coatings "Diathon", 1-1/2 gal/sq. Top Coat: United Coatings "Diathon", 1-1/2 gal/sq. Surfacing: Roofing granules, 35 lbs/sq. 2. Deck: C-15/32 Incline: 1/2 Foam: "SF 4228" or "SF 4230", 1 in. min. Coating: Two coats National Polymers "NP852" at 1-1/2 gal/sq/coat. Surfacing: No.11 roofing granules at # 30 lb/sq. 3. Deck: C-15/32 Incline: 1/2 Existing Roof System: Class A, B or C gravel or smooth surfaced BUR (gravel may be removed). Foam: "SF 4228" or "SF 4230", 1 in. min thickness. Coating: LaPolla"TF 1000" or "TF 750" applied at 3 gal/sq. Surfacing: No. 11 ceramic coated roofing granules applied at 30 lb/sq. 4. Deck: C-15/32 Incline: 1/2 Foam: "SF 4228" or "SF 4230" 1 in. min. Base Coat: BASF "FE Coat 1000," United Coatings "Diathon", National Polymers "NP852", BASF "3-5000," or Neogard "7850-01," 1-1/2 gal/sq. Top Coat: BASF "FE Coat 1000," United Coatings "Diathon," National Polymers "NP852", BASF "3-5000," or Neogard "7850-01," 1-1/2 gal/sq. Surfacing (optional): Roofing granules, 35 lbs/sq. 5. Deck: C-15/32 Incline: 1 Foam: BASF Corp. "FE348-2.8", 1 in. minimum thickness. Base Coat: "LS2200 series" at 1-1/4 gal/sq.

Top Coat: "LS2200 series" at 1-1/4 gal/sq. Surfacing: No. 11 granules at 30 lbs/sq 6. Deck: C-15/32 Incline: 1 Foam: BASF Corp. "FE348-2.8", 1 in. minimum thickness. Base Coat: "HS3200 series" at 1 gal/sq. Top Coat: "HS3200 series" at 1 gal/sq. 7. Deck: C-15/32 Incline: 1 Foam: "SF 4228", 1 in. minimum thickness. Base Coat: "LS2200 series" at 1-1/4 gal/sq. Top Coat: "LS2200 series" at 1-1/4 gal/sq. 8. Deck: C-15/32 Incline: 1 Foam: "SF 4228", 1 in. minimum thickness. Base Coat: "HS3200 series" at 1 gal/sq. Top Coat: "HS3200 series" at 1 gal/sq. MAINTENANCE AND REPAIR SYSTEMS Class A, B or C 1. Deck: NC Incline: ½ Existing Roof System: (To maintain existing Classifications) - Any Class A, B or C, uncoated, insulated or uninsulated, modified bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat: "HS 3200 series", 2 gal/sq. 2. Deck: NC Incline: See Note 1 Existing Roof System: Any EPDM, Hypalon or CPA, single ply membrane system Base Coat: "HS 3200 series", 2 gal/sq Note 1: Classification (A, B or C) and maximum 2 in incline for membrane manufacturer's insulated or uninsulated Roofing Systems (TGFU) Certification. 3. Deck: C-15/32 Incline: 2 Existing Roof System: Class A, B or C gravel or smooth surfaced BUR (loose gravel may be removed) to maintain existing Classification. Barrier board: G-P DensDeck, ¼ in. (min). Foam: "SF 4228" or "SF 4230", 3 in. thick. Base Coat: United Coatings "Diathon", applied at 1-1/2 gal/sq. Top Coat: United Coatings "Diathon", applied at 1-1/2 gal/sq. Surfacing: No. 11 roofing granules at 30 lbs/sq. 4. Deck: NC Incline: 2 Existing Roof System: Class A, B or C gravel or smooth surfaced BUR (loose gravel may be removed).

Foam: "SF 4228" or "SF 4230", 3 in. thick. Base Coat: United Coatings "Diathon", applied at 1-1/2 gal/sq. Top Coat: United Coatings "Diathon", applied at 1-1/2 gal/sq. Surfacing: No. 11 roofing granules at 30 lbs/sq. 5. Deck: NC Incline: See Note 1 Existing Roof System: Any TPO single ply membrane system Base Coat: "HS 3200 series", 2 gal/sq Note 1: Classification (A, B or C) and maximum 3-1/2 in incline for membrane manufacturer's insulated or uninsulated Roofing Systems (TGFU) Certification. 65. Deck: NC Incline: See Note 1 Existing Roof System: Any PVC or TPA single ply membrane system Base Coat: "HS 3200 series", 2 gal/sq Note 1: Classification (A, B or C) and maximum 2-1/2 in incline for membrane manufacturer's insulated or uninsulated Roofing Systems (TGFU) Certification Last Updated on 2013-07-11 Questions? Print this page Terms of Use Page Top 2013 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2013 UL LLC".