The following parts list is maintained for the UPI structural components.

Similar documents
300 Series Racks. 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails. Applications. Features. In The Box. Options

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

Workbench Instructions for Assembly

Fabscan100 Assembly instructions v.1.00

FOLDING POCKET DOOR SYSTEM ALT-F Installation Manual

For assembly see instructions in carton

Factory Assistance: Phone: Fax: Page 1

Installing the CACS Ceiling with Aisle Ducts

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Technical Bulletin #26 Card Reader Installation Issued 3/2/2010

LOW-PROFILE WALLMOUNT CABINETS

INFINITE RANGE - HINGE DOOR

BALTIC WARDROBE 3 DOORS 3 DRAWERS

PCS. Patient Security Service Console. Installation Instructions.

INSTALLER S MANUAL 2 MICROWAVE OVENS

Door Hinges Drill-in Hinges

Visit us at or

LAN Locker Adjustable Shelves

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Fortress Vertical Cable Overview ACTUAL FREIGHT CHARGES APPLY TO ALL FORTRESS RAIL ORDERS

ALL SEASON PATIO COVER

Slide Rail Kit DVA-ASRK-28A DVA-ASRK-36A. Installation Manual

Homestead Bar Cabinet IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent s

Faceplate with visible screws

P /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum

OPTICOM Rack Mount Fiber Cassette Enclosure

Manufacturing and installation instruction. Solidare Verso. Pergola awning (bottom mounted)

Bi-Pass And Bi-Fold Sliders

Hover. Installation Instructions. Raised Panel. Version

ETC Installation Guide

Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratches or oth

Bunk Pod Front Entry Assembly Instructions

CNC Router Parts PRO Machine Kit Cable Track Installation Instructions

2Post Flush Racking System

System 3000 specifications

PH03 Comfort XL Front Assembly Replacement Instructions

ASSEMBLY INSTRUCTIONS. enook Pro

Adjustable Countertop Installation

INSTRUCTIONS FOR ASSEMBLY 2355mm x 4665mm Workshop

RMD5000 Rackmount Kit Instructions

Series 8 Bifold door/shower wall

3.2.3 Rear Door Window and Quarter Window Carrier Assembly

SINGLE TRACK BYPASS (patent pending) barn door hardware

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

WORKSURFACE ASSEMBLY

Polaris General Doors #06016 Installation & Operations Manual Fits Polaris General

RSA GELANDEWAGEN DOUBLE REAR DOOR TRAY. FRONTRUNNEROUTFITTERS.COM should you have any queries. GET ORGANIZED. INSTALL TIME: 0.

`48-`56 Ford Pickup Rear leaf Spring Kit Installation Instructions Tech Line:

1 of 2 3/3/2017 4:49 PM

Installation Instructions - Model V4JSD 1

Installation Instructions for: Saris Cycle Aid. Saris Cycle Air. Saris Cycle Air HD

Mod e l A urora P l u s Walk-In Doo r

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

NEWS Part. N /0 MINITEC NEWS

INFINITE RANGE - CENTRE FOLDING DOOR

Kindly review the following and contact us with any questions or for further details.

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

ASSEMBLY MANUAL WALL MOUNT RACK SWING KIT SR-WM-SWING-10U-3IN SR-WM-SWING-12U-3IN SR-WM-SWING-16U-3IN

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners

NetRack. Please take a moment to make sure that you received everything that s included with your order. Each product is described below.

MultiTable Mod-E 2 Electric Standing Desk

S6 User s Manual USER S MANUAL ver. 1.0

TUBULAR FRONT END KIT INSTALLATION INSTRUCTIONS MUSTANG

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Oxford Stalls Installation Instructions

COACT MEDIA UNIT ASSEMBLY WITH X9 OPEN SHELF STORAGE OPTION PART # INSTALLATION INSTRUCTIONS

FOLDING DOOR SYSTEMS: ASSEMBLY AND INSTALLATION/INSTRUCTION FOLDING DOOR SYSTEM S300 BI-FOLD (S34) V2018.1

pottery barn kids MADISON CABINET HUTCH

Nantucket Buffet

INSTALLATION INSTRUCTIONS and OPERATIONS & MAINTENANCE MANUAL for SUPER SIMPLEX DISAPPEARING STAIRWAYS

L182 - Installation Sheet Modular Wine Rack ( Wall Mount )

Custom Wood Frame Overlay for Glass Doors Installation Instructions

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

Paramount Enclosure. Installation Guide

MAKO TM CASH DISPENSER

Section 8. Curved units. Curved units

ENGINEERING DETAILS for STANDARD SERIES F-16 and DW-16 UNI-FRAME for 1¾ Doors

Installation Manual for Metal Emperor Lockers

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

STOL CH H3-3SP Center Hinge Bracket. IMPORTANT: The Bracket 7H5-3SP is not symmetrical

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

4Post and 2Post Rails for Dell PowerEdge R810

PRINT MAY BE REDUCED - DO NOT SCALE. No Compression Load on Ceiling Possible Lateral Load of 8kg 2 Fixed Pins in Shear with Ceiling

CROWN IMPERIAL ASSEMBLY INSTRUCTIONS

Installing DoorSense August Smart Lock Pro

Empty enclosures AKL / AKi ITC - AKL / AKi Enclosures

Eaton Data Center Racks

SUPPLEMENTAL INSTRUCTIONS

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

RACK 19 AND NETWORKING SOLUTIONS FEATURES

spine desks UNDERSTANDING SPINE DESKS SPINE DESK BASICS MODESTY PANEL & GABLE BASICS PLANNING WITH SPINE DESKS...

ALPHA DIN Wall-Mounted. Distribution Boards

How To Measure Your Finished Opening

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

INSTALLATION GUIDE PREMIUM FRONT BUMPER. AEV30103AE Last Updated: 09/08/14 US PATENTS: D683281, D CHINESE PATENT: ZL

Bulkhead Model Number and

DOLCE STIL NOVO. Tips & tricks for a perfect alignment Consigli e suggerimenti per un perfetto allineamento

Section 6-B-4 Rear Fuselage Riveting

Transcription:

4 PARTS LIST The following parts list is maintained for the UPI structural components. The product code consists of two four-digit parts: the first part refers to the product group and the second to the part number. The serial number of the component group is added to the end of the product group code (5004) according to the size of the component. The part list is updated as required by product changes and amendments of specifications. TABLE OF CONTENTS: Flush-mounted box 18 Inner frame 19 Surface-mounted frame 20 Door and cover 21 Data Flush-mounted box 22 Data Inner frame 23 Data Surface-mounted frame 24 Data Door and cover 25 Data RJ Panel 26 Data parts 27 Data RJ Series 27 RJ-panel 24 28 Blind covers and mounting pieces 29 Tele 3D 29 Page UPI - Parts list 12/2009 17

FLUSH-MOUNTED BOX Depth 62 50042060 50042020 50042030 50042040 50042050 50042020 Flush-mounted box 1D 50042030 Flush-mounted box 3D 50042040 Flush-mounted box 4D 50042050 Flush-mounted box 5D 50042060 Flush-mounted box 200 + inner frame 18 MOD+N/PE 397 263 36 MOD+N/PE 397 370 72 MOD 397 640 72 MOD+N/PE 397 766 30 MOD 720 200 The sides of the flush-mounted box are equipped with pre-punched knock-outs and the box is also provided with mounting brackets for the inner frame. UPI - Parts list 12/2009 18

INNER FRAME 50042120-U 50042130-U 50042140-U 50042150-U 50042120-U Inner frame 1D 18 MOD+N/PE 377 150 50042130-U Inner frame 3D 36 MOD+N/PE 377 250 50042140-U Inner frame 4D 72 MOD 377 435 50042150-U Inner frame 5D 72 MOD+N/PE 377 711 For each flush-mounted box, there is a corresponding inner frame, to which the components can be mounted with DIN rail fasteners. UPI - Parts list 12/2009 19

SURFACE-MOUNTED FRAME Depth 65 50042295 Blind flange for Surface-mounted frame 50042260 50042220 50042230 50042240 50042250 50042220 Surface-mounted frame 1D 50042230 Surface-mounted frame 3D 50042240 Surface-mounted frame 4D 50042250 Surface-mounted frame 5D 50042260 Surface-mounted frame 200 50042295 Blind flange for Surface-mounted frame 18 MOD+N/PE 433 278 36 MOD+N/PE 433 406 72 MOD 433 658 72 MOD+N/PE 433 804 30 MOD 755 234 170 50 The ends of the surface-mounted frame are provided with wiring holes for cable conduits. No inner frame is used with conjunction with the surface-mounted frame, because it is provided with pre-installed DIN rails. UPI - Parts list 12/2009 20

DOOR AND COVER Depth 35 50042380 50042320 50042330 50042340 50042350 50042360 50042370 50042320 Door and cover 1D 50042330 Door and cover 3D 50042340 Door and cover 4D 50042350 Door and cover 5D 50042360 Door and cover 1D 1.5 sections 50042370 Door and cover 3D 2.5 sections 50042380 Door and cover 200 50042390 Door and cover 3D 14 18 MOD+N/PE 438 283 36 MOD+N/PE 438 411 72 MOD 438 663 72 MOD+N/PE 438 809 27 MOD 438 283 45 MOD 438 411 30 MOD 761 240 36 MOD+N/PE 438 411 For each enclosure size, there is a corresponding door and cover combination. The product is delivered assembled, including (depending on the model) the door, cover, hinges, handle and magnets. UPI - Parts list 12/2009 21

DATA FLUSH-MOUNTED BOX Depth 80 50044100 50044102 50044104 50044106 50044100 Flush-mounted box 50044102 Flush-mounted box 50044104 Flush-mounted box 50044106 Flush-mounted box 36 MOD 454 928 54 MOD 454 1054 72 MOD 454 1180 90 MOD 454 1306 The sides of the flush-mounted box are equipped with pre-punched knock-outs and the box is also provided with mounting brackets for the inner frame. UPI - Parts list 12/2009 22

DATA INNER FRAME 50044120 50044122 50044124 50044126 50044120 Inner frame 36 MOD 359 798 50044122 Inner frame 54 MOD 359 924 50044124 Inner frame 72 MOD 359 1050 50044126 Inner frame 90 MOD 359 1176 For each flush-mounted box, there is a corresponding inner frame, to which the components can be mounted with DIN rail fasteners. UPI - Parts list 12/2009 23

DATA SURFACE-MOUNTED FRAME Depth 80 50044110 50044112 50044114 50044116 50044110 Surface-mounted frame 50044112 Surface-mounted frame 50044114 Surface-mounted frame 50044116 Surface-mounted frame 36 MOD 473 954 54 MOD 473 1080 72 MOD 473 1206 90 MOD 473 1332 The ends of the surface-mounted frame are provided with wiring holes for cable conduits. No inner frame is used in conjunction with the surface-mounted frame, because it is provided with pre-installed DIN rails. UPI - Parts list 12/2009 24

DATA DOOR AND COVER 50044130 50044132 50044134 50044136 Depth 65 Depth 31 50044140 50044142 50044144 50044146 50044130 Door and cover 36mod 65 478 958 50044132 Door and cover 54mod 65 478 1084 50044134 Door and cover 72mod 65 478 1210 50044136 Door and cover 90mod 65 478 1336 50044140 Door and cover 36mod 31 478 958 50044142 Door and cover 54mod 31 478 1084 50044144 Door and cover 72mod 31 478 1210 50044146 Door and cover 90mod 31 478 1336 For each enclosure size, there is a corresponding door and cover combination. The product is delivered assembled, including (depending on the model) the door, cover, hinges, handle and magnets. UPI - Parts list 12/2009 25

DATA RJ-PANEL 1 4 3 2 RJ/45 Series includes: 1. RJ 22 * 36 2. RJ 18 * 23 adapter 50043510 Data RJ-panel 8 50043511 Data RJ-panel 8 50043512 Data RJ-panel 8 50043514 Data RJ-panel 8 50043516 Data RJ-panel 8 50043530 Data RJ-panel 12 50043531 Data RJ-panel 12 50043532 Data RJ-panel 12 50043534 Data RJ-panel 12 50043536 Data RJ-panel 12 15*20 224 112 15*19 224 112 18*23 224 112 22*36 224 112 18*17 224 112 15*19 330 112 15*20 330 112 18*23 330 112 22*36 330 112 18*17 330 112 50044060 RJ/45 Series Data 330 112 3. 4. RJ 15 * 19 adapter RJ 18 * 17 adapter 50043510 Data RJ-panel 8 15*20 50043530 Data RJ-panel 12 15*19 UPI - Parts list 12/2009 26

DATA PARTS 1 3 4 9 8 2 6 5 7 50044160 Mounting plate Data 356 445 50044030 Cover frame Data 329 200 50044035 Connection module Data 104 130 mounting frame 50044040 Connection module Data 180 185 cover 50044045 Cover for TV/radio Data 149 185 mode space 50044050 IT Rack 65 Data 315 125 50044051 IT Rack 31 Data 315 95 1. 2. 3. 4. 5. 6. 7. 8. 9. Mounting plate Cover frame RJ-panel 24 IT Rack Connection module mounting frame Cover for TV/radio mode space Connection module cover IT Rack RJ Series IT Rack 65 Is used with 65 deep door and cover IT Rack 31 Is used with 31 deep door and cover DATA RJ SERIES 1 50044055 RJ Series Data 329 72 2 3 4 RJ Series includes: 1. RJ 22 * 36 2. 3. 4. RJ 18 * 23 adapter RJ 15 * 19 adapter RJ 18 * 17 adapter UPI - Parts list 12/2009 27

RJ-PANEL 24 50044150 50044152 50044154 50044156 50044158 50044150 RJ-panel 24 15*19 329 122 50044152 RJ-panel 24 15*20 329 122 50044154 RJ-panel 24 18*17 329 122 50044156 RJ-panel 24 18*23 329 122 50044158 RJ-panel 24 22*36 329 122 UPI - Parts list 12/2009 28

BLIND COVERS AND MOUNTING PIECES 1 50045100 Blind cover 1D and mounting pieces (2 pcs) 50045101 Blind cover 3D and mounting pieces (2 pcs) 438 283 438 411 2 1. 2. Mounting pieces Blind cover TELE 3D 50045105 Surface-mounted frame for tele 3D + mounting plate 50045110 Cover and door for tele 3D 433 406 438 411 1. 2. Surface-mounted frame for tele 3D Cover and door UPI - Parts list 12/2009 29