Similar documents
Cisco QSFP-100G-LR4-S. Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

Shenzhen Opway Communication Co., Ltd. 100Gb/s QSFP28 LR4 Optical Transceiver (OPQE10)

XQS319-10LY. 100 Gb/s QSFP28 LR4 (Ethernet) Optical Transceiver. XQS319-10LY QSFP28 LR4 Optical Transceiver. Features

T G W Q 1 4 B B F 8 1

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

DATA SHEET: Transceivers

PRE-QSFP28-SR4 100Gb/s QSFP28 Optical Transceiver, 100m

T C W Q 1 L A A K C Q

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver

40Gb/s QSFP+ LR4 Parallel Single Mode Optical Transceiver TR-IQ13L-N00. Product Specification

Arista QSFP-40G-PLR4. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW PRODUCT FEATURES APPLICATIONS FUNCTIONAL DIAGRAM.

40Gb/s QSFP+ esr4 Optical Transceiver Module QSFP-4000-ESR4. Product Specification

XQM859-M1PY. 100 Gb/s QSFP28 SR4 Optical Transceiver. XQM859-M1PY QSFP28 SR4 Optical Transceiver. Features

QSFP Gbps QSFP28 PSM4 Optical Transceiver Module. Features

QSFP, 40GBase-SR, 850nm, MM, MPO

Arista 40GBASE-XSR4-AR. Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW APPLICATIONS PRODUCT FEATURES. FluxLight, Inc

QSFP-40GBase-eSR4 MPO, 850nm, MMF, 300m. QSFP-40GBase-eSR4-IND. Quick Spec:

Arista Networks QSFP-100G-SR4-AR. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW PRODUCT FEATURES APPLICATIONS.

SO-CFP4-LR4. CFP4, 103/112 Gbps, 1310nm, SM, DDM, 6.3dB, 10km OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1

Cisco QSFP-40G-SR4. Part Number: QSFP-40G-SR4 PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

SO-QSFP28-SR4. QSFP, 100GBASE-SR, 850nm, MM, MPO OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

XCS319-10LY. 100GBASE-LR4 CFP4 Optical Transceiver. Features. Applications. General Description

40 Gigabit QSFP 850 nm QSFP SR4

1. General Description This product is a 100Gb/s transceiver module for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.

QSFP SFP-QSFP-40G-LR4

Cisco QSFP-40G-SR4 MPO, 850nm,MMF, 150m. Cisco QSFP-40G-SR4 Quick Spec:

40Gbps QSFP SR4 Optical Transceiver Module TR-QQ85S-N00. (Preliminary)

CFP2. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

SO-QSFP28-4xSFP28-AOCxM

QSFP-40G-LR4-S-LEG. 40Gbase QSFP+ Transceiver

QSFP+ Dual LC 40G SMF 10km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

40GBASE-ER4 Ethernet Industrial: -40 C to 85 C. Infiniband QDR and DDR Four 10G DFB base CWDM channels on. Distance * (note2) Interface Temp.

OPENETICS. P/N Gb/sQSFP+SR4Transceiver PRODUCT FEATURES APPLICATIONS STANDARD. Specialist Manufacturer Voice Data Security.

100Gbs QSFP28 PSM4 Optical Transceiver Module WT-QSFP28-PSM4

QSFP SV-QSFP-40G-LR4L

CFP4. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features

QSFP28. Parameter Symbol Min Max Units Notes Storage Temperature TS degc

T A S A 1 E B 1 F A Q

40GBd QSFP+ LR4 Optical Transceiver

40G-PSM4 QSFP+ Transceiver

QSFP SV-QSFP-40G-PLR4L

100G QSFP28 LR4 Receiver

QSFP. Parameter Symbol Min Max Unit Notes. Relative Humidity (non-condensation) RH 0 85 %

QSFP-100G-SR4-AR-LEG. 100Gbase QSFP28 Transceiver

T Q S Q 1 4 H 9 J 8 2

Specification. Small Form Factor Pluggable 28 Duplex / Single TX / Single RX LC Receptacle SFP28. Optical Transceivers 24 Gigabit SDI.

Product Specification 10km Multirate QSFP+ Optical Transceiver Module FTL4C1QM1C

40Gbps QSFP ER4 Optical Transceiver Module OPCS-S40-13-CB datasheet

40G-BASE-LR4 10km QSFP+ Optical Transceiver GTR3QP1L

Product Specification 40GBASE-LR4 Lite QSFP+ Optical Transceiver Module FTL4C1QL2C

Product Specification 40GE SWDM4 QSFP+ Optical Transceiver Module FTL4S1QE1C

10Gb/s CWDM SFP+ Optical Transceiver TR-LXxxL-N00

100Gbps QSFP28 CWDM4 Optical Transceiver Module OPCW-S02-13-CB4 datasheet

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

100Gbps QSFP28 LR4 OTU4 Optical Transceiver Module OPCW-S10-13-CBT datasheet

Product Specification 40GBASE-LR4 QSFP+ Optical Transceiver Module FTL4C1QE1C

T Q S Q 7 4 H 9 J C A

40-Gbps QSFP + Optical Transceiver Module

10Gb/s SFP+ BX LC DDMI Optical module Tx:1330nm/Rx:1270nm 10km transmission distance

QSFP28 Dual LC 100G SMF 2km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

QSFP+ Series. EOLQ-1640G-10 Series. Features. Applications. Ordering Information. Single-Mode 40GBASE-LR4 QSFP+ Transceiver RoHS6 Compliant

T A S A 5 N B 1 F A H

QSFP+ Series Preliminary EOLQ-8540G-03-MO Series

T A S A 1 E H

SFP-10G-M 10G Ethernet SFP+ Transceiver

PROLABS JD121B-C. 10 Gigabit 1550nm SingleMode XFP Optical Transceiver, 40km Reach.

40Gbps QSFP+ IR4 Parallel Single Mode Optical Transceiver Module OPCS-S01-13-CBS datasheet

XFP-10G-Z-OC192-LR2-C

10Gb/s SFP+ BiDi Optical Transceiver. TR-DXxxI-V00, 20Km SMF Application. 10GBASE-LR/LW Bi-directional, LC connector

100-Gbps QSFP28 SR4 Optical Transceiver Module PN: WST-QS28-SR4-C

XFP-10GLR-OC192SR-C. 10 Gigabit XFP Transceiver, LC Connectors, 1310nm, SingleMode Fiber 10km

10Gb/s SFP+ Optical Transceiver Module 10GBASE-SR/SW

QSFP28 100G MPO MMF 850nm 70m Transceiver AQPMDN85ADLN0782. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

XFP-10GER-192IR V Operating Environment Supply Voltage 1.8V V CC V Operating Environment Supply Current 1.8V I CC1.

10Gbps XFP Optical Transceiver

10Gb/s XFP Tunable Optical Transceiver XFP-1080-DTZR. Preliminary Datasheet

This 1310 nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 10km.

10Gb/s SFP+ Optical Transceiver Module AO+-CXXXX-R80. 10GBASE-ZR/ZW, up to 80km SM Fiber Link

10Gbps XFP Optical Transceiver RTXM226-6XX

10Gb/s DWDM XFP Optical Transceiver AOX-DXX-R40

T A S A 1 N H 1 P 1 1

Product Specification 100GBASE-SR10 100m CXP Optical Transceiver Module FTLD10CE1C APPLICATIONS

10Gbps XFP Optical Transceiver RTXM

Product Features. Applications. Descriptions. Ordering Information. Electrical Pin Description

SPQ-10E-SR-CDFG 40G QSFP+ Transceiver

40GBase LR4 QSFP+ Optical Transceivers WST-QSFP+LR4-C

LTA8531 QSFP28 SR4 Transceiver

10Gb/s 10km Datacom XFP Optical Transceiver XFP-10G-LR

SO-SFP28-LR. SFP28, 25GBASE-LR, 1310nm, SM, DDM, 10km OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.1

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V) Nominal Wavelength λ nm Side Mode Suppression Ratio. Receiver

XBR C. 8Gbs SFP+ Transceiver

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V)

Multiplex, Inc. 8.5Gb/s DWDM 80Km LR2 XFP Transceiver Product. Product Overview. Features

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

10Gb/s 80km DWDM XFP Optical Transceiver

LX8501CDR 100G 100m QSFP28 Transceiver 100GBASE-SR4

10Gbps 70KM CWDM XFP Optical Transceiver RTXM226-69X

Applications: Description:

(Tc=-5 to 70 and Vcc= 3.14 to 3.46V)

Transcription:

100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4 Features Hot pluggable QSFP28 MSA form factor Compliant to IEEE 802.3ba 100GBASE-LR4 Up to 10km reach for G.652 SMF Single +3.3V power supply Operating case temperature: 0~70 o C Transmitter: cooled 4x25Gb/s LAN WDM TOSA (1295.56, 1300.05, 1304.58, 1309.14nm) Receiver: 4x25Gb/s PIN ROSA 4x28G Electrical Serial Interface (CEI-28G-VSR) Maximum power consumption 4.0W Duplex LC receptacle RoHS-6 compliant Applications 100GBASE-LR4 Ethernet Links Infiniband QDR and DDR interconnects Client-side 100G Telecom connections

General Description This product is a 100Gb/s transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.3ba standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module de-multiplexes a 100Gb/s optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output channels of electrical data. The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14 nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high performance cooled LAN WDM EA-DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 10km links and compliant to optical interface with IEEE802.3ba Clause 88 100GBASE-LR4 requirements. The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference. Functional Description The transceiver module receives 4 channels of 25Gb/s electrical data, which are processed by a 4- channel Clock and Data Recovery (CDR) IC that reshapes and reduces the jitter of each electrical signal. Subsequently, each of 4 EML laser driver IC's converts one of the 4 channels of electrical signals to an optical signal that is transmitted from one of the 4 cooled EML lasers which are packaged in the

Transmitter Optical Sub-Assembly (TOSA). Each laser launches the optical signal in specific wavelength specified in IEEE802.3ba 100GBASE-LR4 requirements. These 4- lane optical signals will be optically multiplexed into a single fiber by a 4-to-1 optical WDM MUX. The optical output power of each channel is maintained constant by an automatic power control (APC) circuit. The transmitter output can be turned off by TX_DIS hardware signal and/or 2-wire serial interface. The receiver receives 4-lane LAN WDM optical signals. The optical signals are demultiplexed by a 1-to-4 optical DEMUX and each of the resulting 4 channels of optical signals is fed into one of the 4 receivers that are packaged into the Receiver Optical Sub-Assembly (ROSA). Each receiver converts the optical signal to an electrical signal. The regenerated electrical signals are retimed and de-jittered and amplified by the RX portion of the 4-channel CDR. The retimed 4-lane output electrical signals are compliant with IEEE CAUI-4 interface requirements. In addition, each received optical signal is monitored by the DOM section. The monitored value is reported through the 2-wire serial interface. If one or more received optical signal is weaker than the threshold level, RX_LOS hardware alarm will be triggered. A single +3.3V power supply is required to power up this product. Both power supply pins VccTx and VccRx are internally connected and should be applied concurrently. As per MSA specifications the module offers 7 low speed hardware control pins (including the 2-wire serial interface): ModSelL, SCL, SDA, ResetL, LPMode, ModPrsL and IntL. Module Select (ModSelL) is an input pin. When held low by the host, this product responds to 2-wire serial communication commands. The ModSelL allows the use of this product on a single 2-wire interface bus individual ModSelL lines must be used. Serial Clock (SCL) and Serial Data (SDA) are required for the 2-wire serial bus

communication interface and enable the host to access the QSFP28 memory map. The ResetL pin enables a complete reset, returning the settings to their default state, when a low level on the ResetL pin is held for longer than the minimum pulse length. During the execution of a reset the host shall disregard all status bits until it indicates a completion of the reset interrupt. The product indicates this by posting an IntL (Interrupt) signal with the Data_Not_Ready bit negated in the memory map. Note that on power up (including hot insertion) the module should post this completion of reset interrupt without requiring a reset. Low Power Mode (LPMode) pin is used to set the maximum power consumption for the product in order to protect hosts that are not capable of cooling higher power modules, should such modules be accidentally inserted. Module Present (ModPrsL) is a signal local to the host board which, in the absence of a product, is normally pulled up to the host Vcc. When the product is inserted into the connector, it completes the path to ground through a resistor on the host board and asserts the signal. ModPrsL then indicates its present by setting ModPrsL to a Low state. Interrupt (IntL) is an output pin. Low indicates a possible operational fault or a status critical to the host system. The host identifies the source of the interrupt using the 2-wire serial interface. The IntL pin is an open collector output and must be pulled to the Host Vcc voltage on the Host board.

Transceiver Block Diagram Pin Assignment and Description Figure 1. Transceiver Block Diagram Figure 2. MSA compliant Connector Pin Definition

PIN Logic Symbol Name/Description Notes 1 GND Ground 1 2 CML-I Tx2n Transmitter Inverted Data Input 3 CML-I Tx2p Transmitter Non-Inverted Data output 4 GND Ground 1 5 CML-I Tx4n Transmitter Inverted Data Input 6 CML-I Tx4p Transmitter Non-Inverted Data output 7 GND Ground 1 8 LVTLL-I ModSelL Module Select 9 LVTLL-I ResetL Module Reset 10 VccRx +3.3V Power Supply Receiver 2 11 LVCMOS-I/O SCL 2-Wire Serial Interface Clock 12 LVCMOS-I/O SDA 2-Wire Serial Interface Data 13 GND Ground 14 CML-O Rx3p Receiver Non-Inverted Data Output 15 CML-O Rx3n Receiver Inverted Data Output 16 GND Ground 1 17 CML-O Rx1p Receiver Non-Inverted Data Output 18 CML-O Rx1n Receiver Inverted Data Output 19 GND Ground 1 20 GND Ground 1 21 CML-O Rx2n Receiver Inverted Data Output 22 CML-O Rx2p Receiver Non-Inverted Data Output 23 GND Ground 1 24 CML-O Rx4n Receiver Inverted Data Output 1 25 CML-O Rx4p Receiver Non-Inverted Data Output 26 GND Ground 1 27 LVTTL-O ModPrsL Module Present 28 LVTTL-O IntL Interrupt 29 VccTx +3.3 V Power Supply transmitter 2 30 Vcc1 +3.3 V Power Supply 2 31 LVTTL-I LPMode Low Power Mode 32 GND Ground 1 33 CML-I Tx3p Transmitter Non-Inverted Data Input 34 CML-I Tx3n Transmitter Inverted Data Output 35 GND Ground 1 36 CML-I Tx1p Transmitter Non-Inverted Data Input

37 CML-I Tx1n Transmitter Inverted Data Output 38 GND Ground 1 Notes: 1. GND is the symbol for signal and supply (power) common for the QSFP28 module. All are common within the module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal common ground plane. 2. VccRx, Vcc1 and VccTx are the receiving and transmission power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown in Figure 3 below. Vcc Rx, Vcc1 and Vcc Tx may be internally connected within the module in any combination. The connector pins are each rated for a maximum current of 1000mA. Recommended Power Supply Filter Figure 3. Recommended Power Supply Filter Absolute Maximum Ratings It has to be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module. Parameter Symbol Min Max Units Notes Storage Temperature TS -40 85 degc Operating Case Temperature TOP 0 70 degc Power Supply Voltage VCC -0.5 3.6 V

Relative Humidity (non-condensation) RH 0 85 % Damage Threshold, each Lane THd 5.5 dbm Recommended Operating Conditions and Power Supply Requirements Parameter Symbol Min Typical Max Units Operating Case Temperature TOP 0 70 degc Power Supply Voltage VCC 3.135 3.3 3.465 V Data Rate, each Lane 25.78125 Gb/s Control Input Voltage High 2 Vcc V Control Input Voltage Low 0 0.8 V Link Distance with G.652 D 0.002 10 km Electrical Characteristics The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Parameter Symbol Min Typical Max Units Notes Power Consumption 4.0 W Supply Current Icc 1.21 A Transceiver Power-on Initialization Time 2000 ms 1 Transmitter (each Lane) Referred to TP1 Single-ended Input Voltage -0.3 4.0 V signal common Tolerance (Note 2) Differential Input Voltage 15 mv RMS Notes: 1. Power-on Initialization Time is the time from when the power supply voltages reach and remain above the minimum recommended operating supply voltages to the time when the module is fully functional. 2. The single ended input voltage tolerance is the allowable range of the instantaneous input signals. Optical Characteristics QSFP28 100GBASE-LR4 Parameter Symbol Min Typical Max Unit Notes

L 1294.53 1295.56 1296.59 nm Lane Wavelength L 1299.02 1300.05 1301.09 nm L 1303.54 1304.58 1305.63 nm L 1308.09 1309.14 1310.19 nm Transmitter Side Mode Suppression Ratio SMSR 3 db Total Average Launch Power P T 10.5 dbm Average Launch Power, each Lane P AVG -4.3 4.5 dbm OMA, each Lane P OMA -1.3 4.5 dbm 1 Difference in Launch Power Ptx,diff 5 db between any Two Lanes (OMA) Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP), each Lane TDP, each Lane TDP 2.2 db Extinction Ratio ER 4 db RIN 20OMA RIN -130 db/hz Optical Return Loss Tolerance TOL 20 db Transmitter Reflectance R T -12 db Eye Mask{X1, X2, X3, Y1, Y2, Y3} {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} 2 Average Launch Power OFF Transmitter, each Lane - 2.3 dbm Poff -30 dbm Receiver Damage Threshold, each Lane THd 5. dbm 3 Total Average Receive Power 10.5 dbm Average Receive Power, each Lane -10.6 4.5 dbm Receive Power (OMA), each Lane 4.5 dbm Receiver Sensitivity (OMA), each Lane SEN -8.6 dbm Stressed Receiver Sensitivity (OMA), each Lane -6.8 dbm 4 Receiver Reflectance R R -26 db Difference in Receive Power between any Two Lanes (OMA) Prx,diff 5.5 db LOS Assert LOSA -18 dbm LOS Deassert LOSD -15 dbm

LOS Hysteresis LOSH 0. db Receiver Electrical 3 db upper Cutoff Frequency, each Lane Fc 31 GHz Conditions of Stress Receiver Sensitivity Test (Note 5) Vertical Eye Closure Penalty, each Lane 1.8 db Stressed Eye J2 Jitter, each Lane 0.3 UI Stressed Eye J9 Jitter, each Lane 0.47 UI Notes: 1. Even if the TDP < 1 db, the OMA min must exceed the minimum value specified here. 2. See Figure 4 below. 3. The receiver shall be able to tolerate, without damage, continuous exposure to a modulated optical input signal having this power level on one lane. The receiver does not have to operate correctly at this input power. 4. Measured with conformance test signal at receiver input for BER = 1x10-12. 5. Vertical eye closure penalty and stressed eye jitter are test conditions for measuring stressed receiver sensitivity. They are not characteristics of the receiver. Figure 4. Eye Mask Definition Digital Diagnostic Functions The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified. Parameter Symbol Min Max Units Notes

Temperature monitor absolute error Supply voltage monitor absolute error DMI_Temp -3 +3 degc DMI _VCC -0.1 0.1 V Over operating temperature range Over full operating range Channel RX power monitor absolute error DMI_RX_Ch -2 2 db 1 Channel Bias current monitor Channel TX power monitor absolute error Notes: DMI_Ibias_Ch -10% 10% ma DMI_TX_Ch -2 2 db 1 1. Due to measurement accuracy of different single mode fibers, there could be an additional +/-1 db fluctuation, or a +/- 3 db total accuracy. Mechanical Dimensions Figure 5. Mechanical Outlin

ESD This transceiver is specified as ESD threshold 1KV for high speed data pins and 2KV for all others electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM). However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment. Laser Safety This is a Class 1 Laser Product according to EN 60825-1:2014. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007). Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Contact information TEL:+86-755-26641737 E-mail: sales@wintoptec.com Web : www.wintoptec.com