* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Similar documents
Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

02/11/2015

02/11/2015

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay LG 5928

02/11/2015

Installation / Monitoring Technique

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MINI-PS AC/2X15DC/1

02/11/2015

Type CP-S, CP-C & CP-A Switch mode

Installation- / Monitoring technique

CP-T range Product group picture

For Immediate Delivery call KMParts.com at (866)

MINI-PS AC/24DC/1.3

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Switching power supplies CP range, Linear power supplies CP-L range. Content

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020

38 Series - Relay interface modules A

CP-T range Benefits and advantages

Transformers, Power Supply Units and Socket Outlets

38 Series - Relay interface modules A

E-STOP relays, safety gate monitors

Thermistor motor protection relays

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Installation- / Monitoring Technique

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

QUINT-PS/ 3AC/24DC/10

CM-IWM.11 Insulation monitoring relay

08/07/2015

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

MasterINTERFACE 39 Series - Relay interface modules

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MasterINTERFACE 39 Series - Relay interface modules

Power supply CP-E 24/0.75

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

QUINT-PS AC/24DC/40

QUINT-PS/ 3AC/24DC/40

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Electronic timer CT-SDD.22

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Datasheet - PROTECT-IE-02

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

CP-E range Benefits and advantages

LED Driver Compact fixed output

62 Series - Power relays 16 A. Features / /

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Multi-voltage Multi-function. Wiring diagram (without control signal)

LED Driver Compact dimming

Subject to changes 11/2003 Page 1/7

48 Series - Relay interface modules A. Features

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Thermistor motor protection relays

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

Modular timers A

Safety relays Protecting the user and the equipment.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

QUINT-PS-24DC/24DC/10

Relay interface modules A

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

QUINT-PS/ 1AC/24DC/20

83 Series - Modular timers 16 A. Features

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

2 or 4 pole changeover contact Plug-in/Faston 187

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Electronic timer CT-TGD.22

38 Series - Relay interface modules A. Features /

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Power supply CP-E 24/2.5

02/11/2015

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

LED Driver Linear / area fixed output

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

PHOENIX CONTACT

Power supply CP-E 24/20.0

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

02/11/2015

Transcription:

Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1 Safety category 4 according to E 954-1 Output max. 6 O, 1 C s or 1 O for AC 250 V Optionally with release delayed O to 10 min 1-channel or 2-channel connection Line fault detection at pushbutton Optionally automatic function after connection of operating voltage or activation via pushbutton Optionally cross fault detection in emergency stop control circuit Optionally dual voltage version Feedback circuit - for monitoring external ors Integrated short-circuit and overvoltage protection Optionally with protective seperation to IEC/E 60 0, IEC/E 60 947-1 LED displays for channels 1 and 2 and supply Removable terminal strips Wire connection also 2 x 1,5 mm 2 stranded ferruled (isolated), DI 46 228-1/-2/-3-4 or 2 x 2,5 mm 2 stranded ferruled DI 46 228-1/-2/-3 Width 100 mm Approvals and marking M 6800 Short-circuit detection at pushbutton ET Applications Canada Canada / USA see variants Block diagram Protection of people and machines Emergency stop circuits on machines Monitoring of safety gates A4 /A3 S22 33 43 53 63 81 Indication Overvoltage and short circuit protection V... K1 & 3 Monitoring logic K3 K3 3 LED power supply LED LED K3 only at BO 5988/4, BO 5988/5 LED KT2, KT3 on, when operating voltage present on, when supply on relay on, when supply on relay K3 on, when delayed s are energised Mains K3 S M6801_a Circuit diagrams A3 S S22 33 43 53 63 81 A4 A3 S S22 33 77 81 A4 A3 S S22 33 81 A4 S22 S 3 K3 /A3+ 33 43 44 53 54 63 64 81 S22 S K3 /A3+ 33 77 81 t v 78 S22 S K3 /A3+ 33 81 PE 44 54 64 PE 78 PE M 7172 M 7173 BO 5988.47 BO 5988.48 M 7174 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 BO 5988 /.06.03 d

otes Jumper assignment for functions Activation via pushbutton / or automatic function push- Jumper Function button - - M8687 Technical data Input The output s are switches only after operation of the pushbutton. Line fault monitoring at the pushbutton Automatic function for operating voltage / or after emergency stop release Line fault detection at the pushbutton The output s cannot be closed if the pushbutton is already closed before the voltage is applied to, S22 (also in the event of a line fault at the pushbutton). A line fault at the pushbutton which occures after activation of the device is recognized when swichting-on takes place again and closing of the output s is then prevented. If a line fault occurs at the pushbutton after the voltage is already present at, S22, undesired activation will take place, because this line fault does not differ from the normal closing function. The gold-plated s of the BO 5988 also mean that this module is suitable for switching small loads of 1 mva... 7 VA, 1 mw... 7 W in the range 0,1... 60 V, 1... 300 ma. The s also permit the maximum switching current. However, since the gold plating is burnt off at this current level, the device is no longer suitable for switching small loads after this. The PE terminal permits operation of the device in IT systems with insulation monitoring and also serves as a reference point for testing the control voltage. The internal short-circuit protection will be bridged on DC devices, if the protective ground is connected to terminal PE. e or more extension modules B 3081 or external ors with positively-driven s may be used to multiply the number of s of the emergency stop module BO 5988. ATTETIO - AUTOMATIC START! According to IEC/E 60 204-1 part 9.2.5.4.2 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. ominal voltage U BO 5988.--/-00 DC V BO 5988.--/- DC V 1) + AC V 2) DC V 1) + AC 48 V 2) DC V 1) + AC 110 V 2) DC V 1) + AC 0 V 2) DC V 1) + AC 0 V 2) 1) at terminals A3-A4 2) at terminals - Voltage range AC 0,8... 1,1 U at 10 % residual ripple DC 0,9... 1,2 U at 48 % residual ripple DC 0,8... 1,1 U ominal consumption AC approx. 6 VA, DC approx. 3 W ominal frequency 50 / 60 Hz Control voltage at typ. DC + V at 0 V Control current typ. DC 110 ma Minimum voltage at terminals, S22 DC 21 V with activated device Recovery time 2 s A minimum switch-off time of 20 s must be observed if the line fault monitoring function at the pushbutton is active Technical data Output Contact BO 5988.48 BO 5988.62 BO 5988.47 Operate time manual restart typ. 30 ms automatic restart 1 s Release time opening in secondary circuit (-S22) 30 ms + 50 % opening in supply circuit BO5988.47, BO 5988.48 100 ms + 50 %, BO 5988.62 50 ms + 50 % 3 O, 1 C indicator 6 O, 1 C indicator 6 O, 1 O indictor 3 O, 1 C indicator 1 O release delayed The O s...63 /...64 are safety s. ATTETIO! The C s 81- or one O 83-84 can only be used for monitoring. Time delay t v supply is not necessary during elapse of time BO 5988.47/1 0,1... 1 s 0,3... 3 s BO 5988.47/2 0,5... 5 s 1... 10 s 1 s, 3 s, 5 s, 10 s supply must be connected during elapse of time BO 5988.47/4 0,1... 1 s 0,1... 1 min 0,3... 3 s 0,3... 3 min 1... 10 s 0,5... 5 min 3... 30 s 1... 10 min BO 5988.47/5 Repeat accuracy BO 5988.47/1 and BO 5988.47/2 BO 5988.47/4 and BO 5988.47/5 Contact type ominal output voltage 1 s, 3 s, 10, 30 s 1 min, 3 min, 5 min, 10 min + 15 % of setting value + 1 % of setting value Relay, positively-driven AC 250 V DC see limit curve for arc-free operation Signalling of and BO 5988.62 AC 10... 250 V, DC 10... 120 V for AC/DC 0,1... 1 A Thermal current I th see total current limit curve (max. 10 A in one path) release delayed O 77-78 at BO 5988.47 max. 8 A Switching capacity to AC 15 O 5 A / AC 0 V IEC/E 60 947-5-1 C 2 A / AC 0 V IEC/E 60 947-5-1 BO 5988.47 release delayed O 3 A / AC 0V IEC/E 60 947-5-1 Electrical life to AC 15 at 2 A, AC 0 V 10 5 switching cycles IEC/E 60 947-5-1 Permissible operating frequency 600 switching cycles / h Short circuit strength max. fuse rating 6 A gl IEC/E 60 947-5-1 max. line circuit breaker C 10 A Mechanical life 30 x 10 6 switching cycles General data Operating mode Continuous operation Temperature range - 15... + 50 C Clearance and creepage distances overvoltage category / contamination level 4 kv / 2 IEC 60 664-1 EMC Electrostatic discharge 8 kv (air) IEC/E 61 000-4-2 HF irradiation 10 V / m IEC/E 61 000-4-3 Fast transients 2 kv IEC/E 61 000-4-4 2

Technical data Ordering example for Variants Surge voltages between wires for power supply 0,5 kv IEC/E 61 000-4-5 between wire and ground 2 kv IEC/E 61 000-4-5 HF-wire guided 10 V IEC/E 61 000-4-6 Interference suppression Limit value class B E 55 011 Degree of protection Housing IP 40 IEC/E 60 529 Terminals IP 20 IEC/E 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0,35 mm IEC/E 60 068-2-6 frequency 10... 55 Hz Climate resistance 15 / 050 / 04 IEC/E 60 068-1 Terminal designation E 50 005 Wire connection 1 x 4 mm 2 solid or 1 x 2,5 mm 2 stranded ferruled (isolated) or 2 x 1,5 mm 2 stranded ferruled (isolated) DI 46 228-1/-2/-3/-4 or 2 x 2,5 mm 2 stranded ferruled DI 46 228-1/-2/-3 Wire fixing Plus-minus terminal screws M 3,5 box terminal with wire protection Mounting DI rail IEC/E 60 715 Weight 850 g BO 5988.47/1 1... 10 s Characteristics 250 DC V + AC 0 V 50 / 60 Hz ominal frequency ominal voltage Time delay 00 1 nominal voltage 2 nominal votlages 0 without t v without auxiliary supply during time elapse 1 t v 2 t v with auxiliary supply during time elapse 4 t v 5 t v Contacts Type Dimensions Width x height x depth Standard types 100 x 74 x 121 mm /0 DC V + AC 0 V 50 / 60 Hz Article number 0040375 stock item Dual voltage version Output 6 O s, 1 C as monitoring Width 100 mm BO 5988.47/1 DC V + AC 0 V 50 / 60 Hz 1...10 s Article number 0040430 stock item Dual voltage version Output 3 O s, 1 C as monitoring, 1 release delayed O With time delay t v to 10 s Width 100 mm Variants BO 5988. /60 with CSA approval BO 5988. /61 with UL approval (Canada/USA) supply is not nesseary during elapse of time BO 5988.47 / 1 3 O / 1 C s + t v BO 5988.47 / 2 3 O / 1 C s + t v supply must be connected during elapse of time BO 5988.47 / 4 3 O / 1 C s + t v BO 5988.47 / 5 3 O / 1 C s + t v Without time delay t v BO 5988.48 / 0 3 O / 1 C s / 0 6 O / 1 C s as monitoring BO 5988.62 / 0 6 O / 1 C s as monitoring BO 5988. / _00 single voltage model BO 5988. / _ dual voltage model / 106 Protective seperation of control and load circuits according to IEC/E 61 0, IEC/E 60 947 4 kv / 2 referred to overvoltage category II with basic insulation to IEC 60 664 of 2,5 kv / 2. / 3 Dual voltage model 0,5 s operate delay with automatic restart Switching voltage U [V] 200 150 100 50 0 1 2 3 4 5 6 7 8 9 10 Switching current I [A] M 6732 Limit curve for arc-free operation with resistive load 2 2 I [A] 250 200 150 100 50 max. 225 limit curve 10 20 30 40 50 Total current limit curve It is necessary to use the square of the currents in order to obtain a linear limit curve. General formula for determination of the maximum ambient temperature A) Sum of currents 2 per safety = value on scale S I 2 (A 2 ) B) Max. ambient temperature T = Cross point of scale S I 2 (A 2 ) with limit curve Example 1 A) (4A) 2 + (4A) 2 + (4A) 2 + (4A) 2 + (4A) 2 + (4A) 2 = 96 A 2 (Scale S I 2 ) B) Max. ambient temperature T = 43 C (point 1) 1 2 T [C] M6802_a Example 2 A) (0,5 A) 2 + (1 A) 2 + (2 A) 2 + (1 A) 2 = 6,25 A 2 (Scale S I 2 ) B) Max. ambient temperature T = 49 C (point 2) Please note The total current 2 can still be 1,5 A 2 at 50 C, i.e. 0,5 A per safety A) (0,5 A) 2 + (0,5 A) 2 + (0,5 A) 2 + (0,5 A) 2 + (0,5 A) 2 +( 0,5 A) 2 = 1,5 A 2 B) Max. ambient temperature = 50 C 3

Application examples Application examples E- - - ------ /A3 S22 S s - ------ s /A3 S22 S A4 M6803_a A4 M6806_a Two-channel emergency stop circuit without cross fault detection. Activation via pushbutton. - - - Jumper - A jumper must be fitted - for the automatic function. The pushbutton is not required. Application examples s Two-pole emergency stop circuit with emergency stop control device in the supply circuit. Application for long emergency stop loops where the control voltage drops below the minimum voltage of 21 V. Attention Single faults (e.g. line faults at the emergency stop control device) are not detected with this external circuit configuration. - ------ /A3 S22 S /A3 S22 S A4 Two-channel emergency-stop circuit with cross fault detection. Activation via pushbutton. - - - Jumper - A jumper must be fitted - for the automatic function. The pushbutton is not required. M6804_a A4 Contact reinforcement by external ors, two-channel. The output s can be reinforced by external ors with positively-driven s for switching currents > 8 A. Functioning of the external ors is monitored by looping the C s into the closing circuit (terminals - ). M6807_a - --- ------------ /A3 S22 S s - ------ /A3 S22 S A4 M6805_a e-channel emergency stop circuit. This circuit does not have any redundancy in the emergency stop control device circuit. A4 Contact reinformcement by external ors with reduced safety level. M6808_a 4

Application examples S1 S2 s /A3 S22 S A4 M6809_a Two-channel monitoring of a safety gate. S1 must not close before S2 5