Extract from the online catalog

Similar documents
MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MACX MCR-EX-SL-RPSSI-I

Signal conditioner - MACX MCR-UI-UI-NC

MINI MCR-SL-UI-I-LP-NC

DEK-OV- 12DC/ 24DC/ 3

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/ESD/5X1/1X2/300

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Extract from the online catalog

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

AKG 4 GNYE. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-f(-SP)

UTTB 4. Extract from the online catalog. Order No.:

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.:

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

VC-MEMV-S1. Extract from the online catalog. Order No.:

VC-MP-K1. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.:

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

VC-MEMV-K3. Extract from the online catalog. Order No.:

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.:

QUINT-PS-24DC/24DC/10

Safety relays - PSR-SCP- 24DC/ESD/4X1/

MACX MCR-UI-UI-UP(-SP)(-NC)

SAC-3P- 5,0-PUR/M12FR SH

MINI-PS AC/24DC/1.3

SAC-5P- 1,5-PUR/M12FS SH

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

SINEAX TI 807 Passive DC signal isolator

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

High-current terminal block - UKH

Temperature transmitter itemp PCP DIN rail TMT 121

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature Transmitter itemp RTD DIN rail TMT 127

Feed-through terminal block - PT 10-TWIN

PRetrans Table of contents

Operating Instruction

PSD-S AE SM DB/1

CompactLogix 5370 L3 Control System

Switching power supplies CP range, Linear power supplies CP-L range. Content

PHOENIX CONTACT

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Temperature transmitter itemp RTD DIN rail TMT 127

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Coupling Relays and Converters

itemp HART DIN rail TMT112

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Assembly. Front view. Parametrization interface. Power Bus

Differential Charge Amplifier

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Digital Input Output Module for Zone 2 Series 9470/33

itemp PA TMT184 Technical information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Printview: 4-channel analog input module; 4-20 ma; Single-ended - Item No.:

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

VariTrans P V. Safe and Sound.

Technical Information Barrier RB223

QUINT-PS/ 3AC/24DC/40

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

PHOENIX CONTACT

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

0 2 1 â Ó. itemp HART TMT182. Technical Information

Power supply CP-E 24/0.75

Power supply CP-T 24/20.0 Primary switch mode power supply

MINI-PS AC/2X15DC/1

QUINT-PS/ 3AC/24DC/10

Power supply CP-E 24/2.5

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Electronic Circuit Breaker with reset input ESS20-1..

0 2 1 â Ó. itemp HART TMT182. Technical Information

NEW. Datasheet. ACT20M Signal Isolation and Conversion

PACT RCP-4000A-UIRO-Dxxx

QUINT-PS AC/24DC/40

Power supply CP-E 24/2.5

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

DIK 1,5 General data Technical data General

Temperature head transmitter itemp TC TMT 188

Power supply CP-E 24/20.0

Transcription:

Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The General Terms and Conditions of Use apply to Internet downloads. Extract from the online catalog MCR loop-powered isolator, 1-channel, for the electrical isolation of current signals without auxiliary power, with screw connection, input signal: 0(4)..20 ma, output signal: 0(4)..20 ma The illustration shows the 2-channel version with screw connection Order No. 2864419 Ord designation MINI MCR-SL-1CP-I-I EAN 4017918974848 Pack 1 Pcs. Customs tariff 85437090 Weight/Piece 0.058 KG Catalog page information Page 294 (IF-2007) Product notes WEEE/RoHS-compliant since: 12/12/2006 IMPORTANT : This date is valid for Customers in Germany only. Date Format is MM/DD/YYYY.Please contact your local in-country Phoenix Contact location or designated business partner for a Logistics Compliant date in your area.in order to guarantee delivery of RoHS-Compliant product, please purchase Phoenix Contact parts from authorized Phoenix Contact representatives and distributors. Page 1/9

Technical data Page 2/9

Product description The 6.2 mm narrow passive loop-powered isolator MINI MCR-SL-...CP-I-I... is used for the electrical isolation and filtering of 0...20 ma and 4...20 ma standard current signals without additional supply voltage. Input data Description of the input Current input Configurable/programmable No Current input signal 0 ma... 20 ma Current input signal 4 ma... 20 ma Max. input voltage 18 V Max. input current 40 ma Response current Approx. 190 µa Input voltage limitation 18 V Voltage dissipation 1.7 V (at I = 20 ma) Output data Output name Configurable/programmable Current output signal Current output signal Load/output load current output Power supply Range of supply voltages Current output No 0 ma... 20 ma 4 ma... 20 ma 600 Ω (at I = 20 ma output signal) (no separate supply voltage necessary) Connection data Type of connection Screw connection Conductor cross section solid min. 0.14 mm 2 Conductor cross section solid max. 2.5 mm 2 Conductor cross section stranded min. 0.2 mm 2 Conductor cross section stranded max. 2.5 mm 2 Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 12 Stripping length 12 mm Screw thread M3 General data No. of channels 1 Length 102.5 mm Width 6.2 mm Height 93.1 mm Transmission error, max. < 0.1 % (of end value) Temperature coefficient, max. (/K) 0.002 %/K (from measured value / 100 Ω load) Additional error, load-dependent 0.03 % (from measured value / 100 Ω load) Cut-off frequency (3 db) 75 Hz Step response (10-90%) 5 ms (At 600 Ω load) Ambient temperature (operation) -20 C... 65 C Ambient temperature (storage/transport) -40 C... 85 C Degree of protection IP20 Page 3/9

Emitted interference EN 61000-6-4 Immunity to interference EN 61000-6-2 Color green Housing material PBT Installation position Any Assembly instructions The DIN rail bus connector (T-BUS) can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. Conformance CE compliance ATEX approval II 3 G Ex na II T4 X UL, USA / Canada Class I, Div. 2, Groups A, B, C, D or non-hazardous locations GL German Lloyd Page 4/9

Page 5/9

Drawings Application drawing Dimensioned drawing Circuit diagram Logo Page 6/9

Page 7/9

Page 8/9

Address Flachsmarktstr. 8 32825 Blomberg Germany Phone +49 5235 3 00 Fax +49 5235 3 41200 http://www.phoenixcontact.de Phoenix Contact Technical modifications reserved; Page 9/9