ESY 1~ 3 r. Specialized Vac stepless Controllers. Ventilated Heat Exchangers Drycoolers & Air Cooled Condensers

Similar documents
CONTENTS XV300K GB r doc XV300K 2/13

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Instruction manual for STA 1 sectional door operator

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

RSMFX-2R MULTIFUNCTIONAL

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Instruction manual for STA 1 sectional door operator

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Operating Instructions. for. Controller SMS 150 / 151

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

DRM 3~ Vac stepless controllers. for. Three-phase asynchronous Motors of Axial & Centrifugal Fans YEAR. FAN speed Control Solutions

Operating Instructions

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

em4 local - Robust Specific characteristics Part number

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Functional data Factory settings Variable Settings

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

SEPARATOR P20G TYPE USER S MANUAL

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Room Temperature Controllers. for heating and cooling systems

Operating Instructions

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

Electromotoric actuators

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Amplifier Series BASIC. Installation & Operations Manual

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

Power supply CP-E 24/20.0

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Operating Instruction

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Power supply CP-E 24/2.5

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

Overview of types. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

KSC-10 Kelvin Speed controller 10A Rev.00 of 23/01/17

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

em4 em4 alert em4 alert 2G

EC 45 flat with integrated electronics Document ID: en Operating Manual

Electronic fan speed regulators

References 1 for asynchronous motors 1

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

SPECIFICATION, CONTROLS AND ACCESSORIES

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Tangential Fans - Basic principles. Expertise, performance, innovation

VOLTAGE DETECTING SYSTEMS

Room Temperature Controllers. for heating and cooling systems

BROADBAND LINEAR AMPLIFIER Model P150

Room Temperature Controllers. for heating and cooling systems

QUINT-PS/ 3AC/24DC/10

PHV RO High Voltage Passive Probe. Instruction Manual

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

PROXIMITY SENSOR TERMINOLOGY

IM /2016 REV08 INVERTEC V205, V270 & V405

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Type CP-S, CP-C & CP-A Switch mode

Room Temperature Controllers. for heating and cooling systems

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

SCA-SS (70V, 10A)

Technical Documentation

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Current Loop Interface Module M 2025D

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Operating Manual Series Load Pins

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Operating Instructions

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Dynamo Brushless DC Motor and GreenDriveTM Manual

Phase-sequence Phase-loss Relay

MasterINTERFACE 39 Series - Relay interface modules

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

DIGITAL PANEL METER N24 AND N25 METER SERIES

Operating Instructions. for. Controller SMS 160 / 161

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

USER S MANUAL. Rail-mounted temperature transmitter ATL

Transcription:

ESY ~ User Manual Specialized Vac stepless Controllers for single-phase Asynchronous Motors on Axial & Centrifugal Fans ON Ventilated Heat Exchangers Drycoolers & Air Cooled Condensers l Gl oba anty r r a W YEAR FAN speed Control Solutions

WARNING! HIGH LEAKAGE CURRENT First connect to Earth! DO NOT touch the electrical parts of the circuit when the power supply is connected under any circumstances Safety Warnings We disclaim all responsibility for accident, loss or damage caused by the use of these appliances. These must be correctly installed by qualified personnel in conformity with their intended use and, whenever needed, must undergo correct maintenance which should be carried out while ensuring the safety of people, domestic animals and goods. Do NOT tamper with or disassemble the regulator internal components; doing so will INVALIDATE THE GUARANTEE and may cause unnecessary damage. The regulator does not contain components that can be repaired by the user. The regulator must be SUITABLY AND EFFECTIVELY EARTHED by the installer, under his own responsibility, according to the standards in force; earthing is essential for the EMC filter to operate correctly. Precautions When receiving the goods, check that the packing is intact; in the event of any damage due to transportation, notify the forwarding agent according to legal requirements. The regulator must be installed by qualified personnel who will connect the electric supply with GROUND CONNECTION, attach the cables in their permanent positions and commission the plant. Incorrect installation of the ESY00 voltage regulator may cause damage to objects or people, so ensure the instructions in this manual and all required security measures are read and followed carefully. Before supplying power to the unit, make sure that the regulator is correctly connected to the power supply and to earth. Follow the instructions in this manual exactly and observe all safety measures in force. The user must be protected from the electric supply and the motor must be protected from possible overloads in compliance with the standards in force. DO NOT touch any electrical parts of the circuit when the power supply is connected under any circumstances. If the mains supply is "disturbed", which may be due to other electrical power components causing irregularities in the supply (power contactors), it is recommended that supplementary SINGLE phase SURGE ARRESTER filters are installed directly on the regulator supply. Avoid repeatedly connecting and disconnecting the power supply to the regulator; a constant supply keeps the regulator at working temperature and eliminates problems caused by condensate inside the protection case. Install the regulator out of direct sunlight, in order to protect the case from overheating. The appliance can operate at environmental temperatures up to 50 C. Do NOT install it where this temperature may exceed, otherwise the integrity of the regulator will be compromised, since the controller may make the user appliance operate at full load (00%) with all consequent effects. The equipment must be placed vertically, in order to encourage heat dissipation and to ensure sufficient air circulation in a free space measuring at least 50 mm above and below the regulator. If several regulators are to be grouped together on a single electric board, please provide forced air circulation with a fan or with a sufficiently powerful cooling unit. Description of symbols in use in the present manual! Attention! i EMC LVD Factory Default Important information Compliance with: CE mark Electromagnetic Emissions Low Voltage Directives The highlighted characteristics are Factory STANDARD settings PRODUCT end of life WEEE directive

Contents: Safety Warnings... Errore. Il segnalibro non è definito. Precautions... Contents...... EC DIRECTIVES & TECHNICAL STANDARDS...... Mechanical Dimensions ESY-...... OPERATING MODES AND APPLICATIONS... 4 4... TECHNICAL CHARACTERISTICS ESY-... 5 5... ELECTRICAL CONNECTIONS... Errore. Il segnalibro non è definito. 5.. Power Supply Connection (Terminal Block M)... 7 6... SIGNAL CONNECTIONS for the 4 CONFIGURATIONS (ALL-in-ONE)... 8 6.. OM CONFIGURATION (STANDARD SELPRO)... 8 6.. OX Configuration (on request)... 8 6.. OV Configuration (on request)... 9 6.4. OB Configuration (on request)... 9 7... Electrical connection for Slave Module/s... 0 7.. Connection of SLAVE modules, SV series (0-0Vdc power units)... 0 7.. Connecting ESY- to SLAVE-SV / 0-0 Vdc modules (Three-/Single-phase connection)... 0 7.. Connection of SLAVE modules, series (PWM power units)... 7.4. Connecting SLAVE- modules Power supply in phase with the Master unit (network synchronization)... 8... ESY-: CONTROL & POWER CARD IN DETAIL, ALL-in-ONE version... 8.. ESY-: CONTROL & POWER CARD IN DETAIL, SLAVE-ONE versions... 8.. LED signals... 8.. Configuration and selection JUMPERS... 9... Set-up of operating LIMITS and PARAMETERS... 4 9.. Available regulations in the standard ESY- version (ALL-in-ONE)... 4 9.. How to set up the operating limits for the ALL-in-ONE version)... 4 9.. How to set up the operating limits for SLAVE-ONE modules (only SLAVE-SV version)... 5 9.4. Table showing the scale of values for setting up the ESY- regulation VAC Limits... 5 9.5. Tables for the Set-Point selection:... 6 9.5.. Set-Point values, range 0-5 bar (Transducer 4-0 ma)... 6 9.5.. Set-Point values, range 0-5 bar (Transducer 4-0 ma)... 6 9.5.. Set Point values, range 0-5 bar (Transducer 4-0 ma)... 7 9.5.4. Set Point values, range 0-0 bar (Transducer 4-0 ma)... 7 9.5.5. Set-Point values, range 0-45 bar (Transducer 4-0 ma)... 8 9.5.6. Set Point values, range 0-0 bar (Transducer 0,5-4,5 Vdc)... 8 9.5.7. Set-Point values, range 0 C to 60 C (NTC probe 0kohm@5 C)... 9 9.6. Regulation with Double SET-Point (optional)... 9 0. Function diagrams & Operating parameters in MASTER & SLAVE modes... 0 0.. ESY- MASTER mode... 0 0.. ESY- SLAVE mode... 0. ACCESSORIES..... Manual Remote Control Units... Errore. Il segnalibro non è definito... Pressure Transducer for 4-0 ma & 0-5 V.... Temperature Probe NTC (0 kohm@5 C)... Errore. Il segnalibro non è definito..4 RGF-MEI(4) / UNIVERSAL input Expansion Module... Errore. Il segnalibro non è definito. PRODUCT end of life The device must be disposed of separately, according to the local authority advice.

. EC DIRECTIVES & TECHNICAL STANDARDS This series has been designed and manufactured for use in industrial environments, and complies therefore with the following European Directives: Machine Directive 98/7 CE and following amendments Low Voltage Directive (LVD) 006/95/EC EMC Directive 004/08/EC Thanks to its advanced technical solutions, the ESY00 series has obtained the CE mark in compliance with the EMC (Electromagnetic Compatibility) directive 004/08/EC also in household environment. The essential requirements of the directive are satisfied by the conformity to the generic standards for industrial environments. EMC LVD Directive Standard Code Description 98/7/CE EN 6004- Safety of machinery. Electrical equipment of machines. 7//CE EN6004- Safety of machinery. Electrical equipment of machines. EN 5078 Electronic equipment for use in power installations. 89/6/CE EN 6000- Adjustable speed electrical power drive systems. Part : EMC product standard including specific test methods. All products have been tested in accordance with the procedures and test conditions laid down in the standards specified in the product technical file. Since these products are destined to be used not only as stand alone systems, but also as components of other machines or plants, all compatibility tests to the standards have been performed under typical conditions of use. In particular, the tests have been performed in a system consisting of a voltage controller RGM00, a control cable and relative commands, a supply cable, a motor cable and a group of fans with an equivalent power to the value of the nominal current of the controller, set to operate within specific VAC values for the single-phase regulation according to EMC requirements.! WARNING! The final specifications of the system or plant, in compliance with the EMC directive, are in any case the responsibility of the installer, who must put the system into operation carefully, according to the rules in force and following the information provided by the present manual.. Mechanical Dimensions ESY- Model A B C D E F Kg. fastening holes ESY 08 95 6 97 95 45 6.4 Kg 5 ESY 95 6 97 95 45 6.5 Kg 5 ESY 6 40 5 5 95 9 0.7 Kg 5 ESY 0 40 5 5 95 9 0.8 Kg 5 8 A / A 6 A / 0 A

. OPERATING MODES AND APPLICATIONS The ESY devices are electronic analog regulators of single-phase AC voltage, which use the phase-cutting principle (Triac) in order to vary the output active voltage applied to a resistive or inductive load. When connected to asynchronous high-slip electric motors of fans or pumps, they control their rotational speed in order to maintain the key parameter within desired values. On this purpose they have been projected and specialized for control applications on Air Cooled Heat Exchangers, used in Air Conditioning, Refrigerating, Air Handling and Ventilation Systems. The series is available in the following versions: - ALL-in-ONE (multi-input), with 4 control inputs, inputs for ma-vdc-ntc sensors and 0-0Vdc control signal, for MASTER- SLAVE operating modes. - SLAVE-ONE, with input for 0-0Vdc (Slave-SV) or PWM (Slave-) control signals, to be used as single regulation units or as additional modules in order to share out the overall controlled power, only for SLAVE operating mode. With the ALL-in-ONE mode, the selection of input signal and operating mode are performed automatically: the controller operates through the presently active sensor/signal and there is NO need to use any selection or programming hardware device. The regulator selects the currently ACTIVE control signal, according to the mode preset by the Jumpers. It is possible to modify the factory settings during the installation procedure of the device, by moving the following JUMPERS: J, operating mode: DIRECT - the VAC output increases as the control signal value increases REVERSE - the VAC output decreases as the control signal value increases J, VAC fans at Set Point: VAC/RMP = 00% with = MAX, the Set-P corresponds to the fans Max-speed VAC/RPM = 0% with = MIN, the Set-P corresponds to the fans Min-speed J, operation of trimmer P: MIN for the Min. AC voltage limit supplied to the connected motor; (J for SLAVE-SV) Cut-Off for the AC voltage limit of the connected motor; J4, output for Slave units control: with control signal for SLAVE-SV units, with 0-0Vdc input signal with control signal for SLAVE- units, with PWM input signal While the Proportional Band (Pb) values are already factory preset (see Table: Operating Parameters), the Set Point values are determined through a couple of -position rotary switches: and adj., which are intended to be used quickly and easily even by base users. The selection of the Set Point is immediate, and two LEDs (+ & -) will show the relationship between this desired value and the signal value perceived through the presen tly active sensor; the Set Point will be reached when both LEDs will be off. In addition, there are LEDs indicating the selection of the First or Second Set Point (only for optional card with double Set Point), and a LED showing the presence of power supply. With the SLAVE-ONE version, two types of SLAVE units are available: SV (input 0-0Vdc), and (input PWM). All ESY- units are equipped with: Complete galvanic separation between AC mains supply and control inputs; EMC mains filter with Residential, Commercial & Light Industrial limit (conformity with PDS systems), fit to be used with equipment directly connected to the low voltage mains supply; Overvoltage protection on the mains supply; Short circuit protection on the connection of the control sensors/signals; Protection filters on control inputs The ESY- series is available in the sizes 8A A 6A 0A, with single phase supply voltage 0V/50Hz, and it is housed in a GW Plast 0 C case with protection degree IP55 and high impact resistance, for out of doors installations (-0T50). The controller can be used both in Condenser mode (pressure transducer) and in Dry-Cooler mode (temperature probe) without the need of any further configuration or programming, with two operating SET-Points (selection of Set-Point & ), beside the Remote- SLAVE Unit mode, when driven by an external controller generating a 0-0Vdc control signal. i OM mode (default) Moduli SLAVE - SLAVE units MAX n.5 0-0 Vdc PWM BAR (ma-vdc) Input CIRCUITs for CONDENSERs FANs C (NTC) Input CIRCUIT for DRY-Cooler 0-0Vdc Input CIRCUIT for Remore Controller PE L N ALIMENTAZIONE POWER SUPPLY SEGNALI DI REGOLAZIONE / CONTROL SIGNALS IN 4-0mA 0-5Vdc IN IN 4-0mA NTC 0-5Vdc NTC IN4 0-0Vdc 0-0Vdc OUT 0-0Vdc 60Hz applications: only with factory calibration The regulator works correctly also with 60 Hz, but it is necessary to calibrate the output signal to 00% in order to optimize the regulation and avoid pulse and beat frequencies.. P W M 4

4. TECHNICAL CHARACTERISTICS ESY- POWER SUPPLY OPERATING PRINCIPLE CURRENT POWER OPERATING CHARACTERISTICS CONTROL SIGNALS AND CONTACTS i OPERATING PARAMETERS LED SIGNALS Voltage 0VAC ± 0 % single phase (on request 0VAC - 400VAC) Frequency 50Hz standard (60 Hz only factory calibration) Overvoltage Protection for installation Category II (4 KV) Electronic analog regulators of single-phase AC voltage, which use the phase-cutting principle (Triac) in order to vary the output active voltage applied to a resistive or inductive load. ESY 08 08 A up to 50 C environment; if over, decrease 0,4 A/ C Rated ESY A up to 50 C environment; if over, decrease 0,6 A/ C ESY 6 6 A up to 50 C environment; if over, decrease 0,8 A/ C ESY 0 0 A up to 50 C environment; if over, decrease,0 A/ C ESY 08 6A Starting current ESY 4A (for loads upstream of the regulator) ESY 6 A ESY 0 40A Overload 00% of the rated current (max. 0 every ) Control Circuit VA Thermally dissipated, W per supplied Ampere Master (Controller Mode) The output voltage varies in order to maintain the value measured by the (inputs IN,IN,IN) transducer within the proportional band (Pb = factory calibration) Slave (Power Unit Mode) The output voltage varies according to the 0-0 Vdc control signal applied to the (Input IN4) input IN4, according to the current configuration. IN 4-0 ma for 00 ohm (R) Config. 0M Master (Controller) IN 4-0 ma for 00 ohm (R) IN NTC 0kohm @ 5 C ALL-in-ONE SLAVE ONE standard On request Config. 0X Config. 0V Config. 0B Slave (Power Unit) IN 4 0-0Vdc for 0 kohm Master (Controller) IN IN IN 4-0 ma for 00 ohm (R), NTC 0 kohm @ 5 C NTC 0 kohm @ 5 C Slave (Power Unit) IN 4 0-0Vdc for 0 kohm IN 0-5 Vdc Master (Controller) IN 0-5 Vdc IN NTC 0 kohm @ 5 C Slave (Power Unit) IN 4 0-0Vdc for 0 kohm Master (Contoller) IN IN IN 4-0 ma for 00 ohm (R) 0-5 Vdc NTC 0 kohm @ 5 C Slave (Power Unit) IN 4 0-0Vdc for 0 kohm Contact for Set-Point switching : selection of Set Point or Set Point (option Double Set-Point ) Config. SV Slave (Power Unit) IN 0-0Vdc for 0 kohm Standard Config. Slave (Power Unit) IN PWM (PPM-Triac) control voltage 5V 0V Set-Point Regulation Easy adjustment with couple of -position rotary switches Input type 4-0 ma 0-5 Vdc NTC 0K @ 5 C Main Set Point () 8 8 ma 0,5-4,5 Vdc 0 60 C Step Set Point adjustment (adj) 0, ma 0,04 Vdc 0,5 C Proportional Band (default),5 ma 0,65 Vdc 7 C Minimum/Cut-Off limit Adjustable from 0% to 70% of the output voltage Maximum limit Adjustable from 00% to 0% of the output voltage Acceleration time (default) 5 Operating mode DIRECT (DIR) VAC output increases as the input value increases) REVERSE (REV) VAC output decreases as the input value increases) AC voltage at Set Point Selection of MAX Vac value maximum fan speed Selection of MIN Vac value minimum fan speed Lower VAC limit Selection of Cut-Off limit (C-Off) o Selection of MAX Vac Limit (MIN) Slave Units AUX. control Selection for Analog 0-0Vdc signal (three / single phase supply) Selection for logic PWM signal (same as the remote unit supply) DL Power Supply O.K. - Signal value is lower than Set-Point value ± 0% of the Proportional Band (Pb) + Signal value is higher than Set-Point value Set-Point selection Available optional card with Set-Point selection Double Set-Point function 5

OUTPUT SIGNALS PROTECTIONS CASE INSULATION WORK ENVIRONMENT INSTALLATION V Transducer voltage supply V (+0/-0%) max. 5mA Config. 0M V Transducer voltage supply V (+0/-0%) max. 5mA + 0V Transducer voltage supply 0,0V (±%) OUT Output signal for slave unit: 0-0Vdc or PWM (MAX 5 modules) V Transducer voltage supply V (+0/-0%) max. 5mA Config. 0X V Transducer voltage supply V (+0/-0%) max. 5mA + 0V Transducer voltage supply 0,0V (±%) OUT Output signal for slave unit: 0-0Vdc or PWM (MAX 5 modules) V Transducer voltage supply 5,0V (±%) Config. 0V V Transducer voltage supply 5,0V (±%) + 0V Transducer voltage supply 0,0V (±%) OUT Output signal for slave unit: 0-0Vdc or PWM (MAX 5 modules) V Transducer voltage supply V (+0/-0%) max. 5mA Config.0B V Transducer voltage supply 5,0V (±%) + 0V Transducer voltage supply 0,0V (±%) OUT Output signal for slave unit: 0-0Vdc or PWM (MAX 5 modules) Config.SV + 0V Transducer voltage supply OUT Output signal for slave unit: PWM (MAX 5 modules) EMC mains filter Compliance 89/6 Conformity for devices that are directly connected to the low voltage mains Overvoltage Protection Complying with EN 6000-4-5 : overvoltage category II (4 KV) Control Input Protection Protection from electrical disturbances of the connection Transducer Supply Protection Protection from short circuit of the transducer output supply Materials GW-Plast 0 C (max. temperature 0 C) aluminium, fiberglass Protection degree IP 55 (standard) IP 00 (on request) MAX Heatsink Temperature 60 C Environmental Pollution Low Pollution Fire Resistance D Category Endurance of the insulation materials against electrical stress Control Circuits Long Working Temperature -0 T 50 ( from 0 C to + 50 C ) Storage Temperature -0 T 85 ( from 0 C to + 85 C ) Vibrations Lower than G (9.8 m/s ) Class I (use of protective earthing conductor) 000 Vac between grounding and voltage supplied components of the device 500Vac between control input and voltage supplied components of the device 4000 Vac between control input and mains supplied components Ageing Characteristics 60.000 hours Wall mounting ONLY in vertical position, with N 4 holes 5 mm, providing at least 0 mm insulation around the device The device is suitable for the installation in class I, II, III equipments. 6

5. ELECTRICAL CONNECTIONS Connect the controller as shown in the figure below, paying attention to the following points. 5.. Power Supply Connection (Terminal Block M) -Before supplying power to the unit, check carefully the power connection and the efficiency of EARTH connection. -Ensure that power conductors and EARTH CABLES have a cross section suitable to the connected load. -Place a couple of fuses with suitable amperage upstream of the disconnector. -Do NOT install the device in environments where ambient temperature may exceed the maximum values allowed (T amb 50 C). -Mount the equipment vertically, in order to encourage heat dissipation and to ensure sufficient air circulation in a free space measuring at least 50 mm above and below the regulator. -If the mains supply is "disturbed", which may be due to other electrical power components causing irregularities in the supply, it is recommended to install supplementary SINGLE phase SURGE ARRESTER filters directly on the regulator supply. -Do NOT alter or damage the identification stickers on the equipment. -NEVER force the rotary switches beyond their mechanical end stops. -The power cables (power supply and load), must be installed separately from the control cables, keeping the maximum possible distance between the power and signal conductors. -Do not mix power cables and signal cables in the same raceway. Where cables must cross one another, ensure they are at an angle as near to 90 as possible to minimize interference. WARNING : Use heat resistant cables, able to withstand a temperature rated at 90 or above. SURGE ARRESTER : electric protection placed between the regulator supply and the earth, meant to protect the device from transient overvoltage. WARNING: Do NOT use differential switches with values lower than 00mA -It is advisable to provide a by-pass switch in order to run the load even in case of disconnector failure (emergency by-pass). When connecting the by-pass, it is necessary to keep the phase correspondence unaltered. 7

6. SIGNAL CONNECTIONS for the 4 CONFIGURATIONS (ALL-in-ONE) After checking carefully all power supply connections, connect the input signal/s and supply the card. The output voltage varies from zero Vac to 0 Vac, according to the variation of the control signal. For the connection of the control signal, use an ordinary twisted-pair cable in disturbance-free environments, while in presence of environmental electromagnetic disturbances use a shielded twisted cable with the screen connected to earth, keeping it as far away as possible from other power cables. The function modes, both always available in the present series, can be: - MASTER with Set-Point, using the inputs In In In (for 4-0mA, 0-5Vdc or NTC probe) - SLAVE, using the input In4 ( for 0-0V control signal) The controllers of the ESY-/ALL-in-ONE series can be set in the following four (4) configurations, described below. The OM configuration is standard SELPRO 6.. OM CONFIGURATION (STANDARD SELPRO) = 0% 00% N Name Function OM CONF. Output voltage V (+0/-0%) V supply max. 5 ma Transducer Input IN 4-0 ma N GND Ground GND 4 IN 5 V 6 IN Transducer Input N Output voltage supply Transducer Input N 4-0 ma V (+0/-0%) max. 5 ma NTC 0kohm @ 5 C 7 GND Ground GND 8 IN4 Input N 4 (only SLAVE control) 0-0Vdc 9 +0V Output voltage supply 0,0V ±% 0 OUT Slave modules control Output 0-0Vdc / PWM GND Ground GND Set-Point & selection Contact Open = Closed = 6.. OX Configuration (on request) = 0% 00% N Name Function OX CONF. V (+0/-0%) V Output voltage supply max. 5 ma Transducer Input IN 4-0 ma N GND Ground GND Transducer Input NTC 0kohm 4 IN N @ 5 C V (+0/-0%) 5 V Output voltage supply max. 5 ma Transducer Input NTC 0kohm 6 IN N @ 5 C 7 GND Ground GND 8 IN4 Input N 4 (only SLAVE control) 0-0Vdc 9 +0V Output voltage supply +0,0V ±% 0 OUT Slave modules control Output 0-0Vdc / PWM GND Ground GND Set-Point & selection Contact Open = Closed = 8

6.. OV Configuration (on request) = 0% 00% N Name Function OV CONF. V Output voltage supply + 5,0V ±% Transducer Input IN 0-5 Vdc N GND Ground GND 4 IN Transducer Input N 0-5 Vdc 5 V Output voltage supply + 5,0V ±% 6 IN Transducer Input NTC 0kohm N @ 5 C 7 GND Ground GND 8 IN4 Input N 4 (only SLAVE control) 0-0Vdc 9 +0V Output voltage supply +0,0V ±% 0 OUT Slave modules control Output GND Ground GND Set-Point & selection Contact 0-0Vdc / PWM Open = Closed = 6.4. OB Configuration (on request) = 0% 00% N Name Function OB CONF. V (+0/-0%) V Output voltage supply max. 5 ma Transducer Input IN 4-0 ma N GND Ground GND 4 IN 5 V 6 IN Transducer Input N Uscita tensione alimentazione Transducer Input N 0-5 Vdc 7 GND Ground GND 8 IN4 Input N 4 (only SLAVE control) + 5,0V ±% NTC 0kohm @ 5 C 0-0Vdc 9 +0V Output voltage supply +0,0V ±% 0 OUT Slave modules control Output GND Ground GND Set-Point & selection Contact 0-0Vdc / PWM Open = Closed = 9

7. Electrical connection for Slave Module/s The controllers of the ESY- / ALL-in-ONE series include moreover the SLAVE-ONE power units, in the two following versions: - SLAVE-SV with input for 0-0Vdc control signal - SLAVE- with input for PWM control signal All the models of the series share the same technical characteristics and are available in different sizes: 8 A A 6 A 0 A, 0Vac/50Hz, all suitable for outdoor applications, in plastic case 0 C and protection degree IP55. Moreover, the SLAVE-SV control unit, with control input 0-0Vdc has an auxiliary output that allows to control further SLAVE- units. By using exclusively SLAVE-SV units, it is possible to share equally the total load on the three-phases (R-S-T), so as to prevent the risk of overloading the electric line on just one phase (regulation performed by two or more controllers, which have the 0-0Vdc control signal in common). The SLAVE-SV modules do not require the same supply phase for every module connected to the 0-0Vdc control signal (network synchronization), which is instead needed when connecting SLAVE- units (PWM input). 7.. Connection of SLAVE modules, SV series (0-0Vdc power units) SLAVE SV module: 0-0Vdc control signal Terminal block N Name Function SV CONF. IN Control Input 0-0Vdc GND Ground GND 0V Potentiometer AUX. supply 4 OUT - Output signal (5/0V) for 5 OUT + slave PWM modules 0,0V ±% PWM 7.. Connecting ESY- to SLAVE-SV / 0-0 Vdc modules (Three-/Single-phase connection) ESY OM J4=0-0V ESY SV ESY SV 0

7.. Connection of SLAVE modules, series (PWM power units) The SLAVE- unit allows the connection of the only PWM (PPM-Triac) control signal. The input is optimized in order to be compatible with every device having a PWM control signal, from 5V to 0V. All connected SLAVE- units require the same supply phase as the remote controller, which generates the PWM control signal (network synchronization) SLAVE module: PWM control signal Terminal block PWM NON polarized input for PWM PWM control signal (from 5V to 0V) PWM 7.4. Connecting SLAVE- modules Power supply in phase with the Master unit (network synchronization) ESY OM J4=PWM ESY ESY

8. ESY-: CONTROL & POWER CARD IN DETAIL, ALL-in-ONE version MAX OUT CUT-OFF (MIN OUT) Led Led - + adj Led Led - + P P P P4 Led P P4 adj Led DL J Led P5 P6 adj J Double Set-Point optional card J J4 Jumper & LED J J J J4 DL DL - DL + Description ESY- / ALL-in-ONE DIRECT-REVERSE mode selection VAC Output at SET-POINT CUT-OFF / MIN OUT selection EXTRA-power control Output Power supply O.K. Set-Point higher than sensor signal Set-Point lower than sensor signal Set-Point ON Set-Point ON Power supply terminal block Control signals terminal block 8.. ESY-: CONTROL & POWER CARD IN DETAIL, SLAVE-ONE versions SLAVE-SV (0-0V) DL Jumper Description ESY- / SLAVE-SV J CUT-OFF / MIN OUT selection DL Power supply O.K. SLAVE- (PWM) J Power supply terminal block Control signals terminal block Power supply terminal block Control signals terminal block

8.. LED signals The cards present LED signals, which point out the state and the operation of the controller. The LED signals of the complete version ESY- / ALL-in-ONE are shown in the table below: Green LED Power supply O.K. Green LED higher than the signal value * Green LED lower than the signal value * Green LED Set-point selection active Green LED Set-point selection active DL MAX out 0Vac 00% 80% Pb * ± 0% of the Proportional Band (Pb) 8.. Configuration and selection JUMPERS CUT-Off 0% 0% SIGNAL UNDER OFF leds (0% di Pb) SIGNAL OVER IN Before starting the set-up procedure for operating parameters and limits, it is necessary to determine the controller s operating modes by moving the configuration jumpers and modifying, when needed, the factory default settings. J Position Default Function Mode REV DIR DIR Regulation characteristics Reverse (REV) Direct (DIR) J MAX MIN MAX AC output voltage at Set-Point MAX AC voltage to fans MIN AC voltage to fans J (*J) CUT-OFF MIN CUT-OFF Type of regulation start Start / Stop AC voltage MINIMUM rpm VAC limit J4 PWM Control for Extra- PWM signal unit 0-0Vdc power SLAVE SV or 0-0 Vdc units 0-0V signal SV unit (*J : symbol for configuration jumper in SLAVE-ONE version) ATTENTION: With J in MAX position (Sp at MAX), the AC output voltage at Set Point is equal to the preset MAX Vac limit value.

9. Set-up of operating LIMITS and PARAMETERS 9.. Available regulations in the standard ESY- version (ALL-in-ONE) The ESY- controllers present two regulation Trimmers for setting up the operating limits (MIN out / Cut-Off and MAX out), the automatic regulation performs the variations of fans speed, and a couple of -positions rotary switches for setting up the SET-Point of reference with ease. CUT-OFF (MIN-out) adj. MAX-out AC voltage limit for MAX-RPM% threshold CUT-OFF (MIN-out) adj. AC voltage limit for Cut/Off or MIN-RPM% threshold Main Set-Point (see following tables for position / value correspondence) Set-Point for an accurate adjustment of ( see following tables for position / value correspondence ) 9.. How to set up the operating limits for the ALL-in-ONE version Before starting the set-up procedure for operating parameters, it is necessary to determine the AC voltage operating limits, within which the automatic variation of speed takes place. The limits must be set up according to the procedures described as follows: MAX Vac limit It determines the value of maximum AC voltage to be supplied to the fan in automatic operation (from 00% to 0%), in order to limit the maximum airflow rate or the fan noise at MAX rpm. It is factory preset at the maximum value of 0, corresponding to the 00% of the control value. Set up of 'MAX out' voltage value: ) move the Jumper J to ON (REV) position; ) turn the trimmer MAX out from position 0 up to the desired value of MAX AC voltage limit; ) turn the Jumper J back to the ON position - in automatic operation, the MAX- RPM% limit of output voltage supplied to the load corresponds to the determined AC voltage limit. Cut-Off limit It determines the value of minimum AC voltage to be supplied to the fan in automatic operation (from 5% to 80%): the starting voltage supplied to the fan is enough to give an adequate torque to start the fan rotation. Set up of 'CUT-OFF' voltage value: ) move the Jumper J to ON position; ) turn the trimmer from position up to the desired AC voltage value of MIN rpm; ) turn the Jumper J back to the ON position - the regulation of the fan starts from the determined CUT-Off VAC value MIN Vac limit It allows to set up manually the minimum AC output voltage supplied to the fan, from 0% to 80%, and permits to check: - the correct phase-cutting of the controller - the Cut-OFF set up Set up of 'MIN out' voltage value: ) move the Jumper J to ON position; ) turn the trimmer from position, until reaching the desired MIN rpm voltage value - At start up the fan operates at the determined minimum Ac voltage limit 00% 80% 0% 0% 0% 0% 4

9.. How to set up the operating limits for SLAVE-ONE modules (only SLAVE-SV version) The following procedures allow to set up the AC voltage limits, within which the 0-0 Vdc control signal is automatically controlled. MIN Vac limit It allows to set up manually the minimum AC output voltage supplied to the fan, from 0% to 90%, and permits to check: - the correct phase-cutting of the controller - the Cut-OFF set up Set up of 'MIN VAC out' voltage value: ) move the Jumper J in ON position; ) turn the trimmer from position, until reaching the desired MIN rpm voltage value; now the load is always supplied starting from the determined MAX AC voltage limit Cut-OFF limit It determines the value of minimum AC voltage to be supplied to the fan in automatic operation (from 5% to 80%): this prevent the fan to be supplied with a lower AC voltage, which would be not enough to give an adequate torque for keeping the fan rotating. Set up of 'CUT-OFF' AC voltage value: ) move the Jumper J to ON position; ) turn the trimmer from position, until reaching the desired MIN rpm voltage value ) turn the Jumper J back to the ON position now the load is supplied starting from the CUT-Off value MAX Vac limit It determines the value of maximum AC voltage to be supplied to the fan in automatic operation (from 00% to 0%), in order to limit the maximum airflow rate or the fan noise at MAX rpm. It is factory preset at the maximum value of 0, corresponding to the 00% of the control value. Set up of 'MAX out' voltage value: ) jumper the inputs IN and +0V: the AC voltage output is at 00% ) turn the trimmer MAX out from position 0 up to the desired value of MAX AC voltage limit (ex.: 80%); ) remove the jumper between IN and +0V : in automatic operation, the MAX voltage limit supplied to the load corresponds to the determined AC output voltage limit 0% 0% 0% 0% 00% 80% 9.4. Table showing the scale of values for setting up the ESY- regulation VAC Limits Scale 4 5 6 7 8 9 9 0 0 MAX OUT CUT-Off (*) 5 4 6 7 (*) 5 4 6 7 (*) move the selection jumper in order to pass from 8 8 the Cut-Off limit to the MIN out limit; always check the difference between VAC values, as shown in the table below 9 0 MIN OUT ALL-in-ONE SLAVE-ONE MAX C-OFF MIN MAX C-Off (MIN) 0 40 60 55 45 70 65 85 80 60 00 90 0 0 90 4 0 5 5 60 5 5 60 5 50 90 5 6 85 50 60 0 50 7 05 60 70 5 65 8 5 70 80 0 75 9 5 80 90 5 85 0 0 85 90 0 90 Limit 5

After selecting the operating modes and setting up the operating limits, it is necessary to determine the operating point of the regulation: the SET-POINT, on the basis of the scales and ranges referring to the connected sensor (*). The Set-Point is easily and quickly fixed through the couple of -position rotary switches, named as follows: (main reference point for the regulation) and adj. (accurate adjustment of the operating point fixed with ). For the selection of the Set-Point values, refer to the following tables according to the ranges and to the types of sensors in use. (*) The controller ESY- operates automatically according to the sensor/signal currently connected or in use. 9.5. Tables for the Set-Point selection: - -- -4-5 -6 adj. 7 5 6 4 8 9 0 +/- 4 56 7 8 9 0 + ++ - -- -4 +4-5 +5-6 +6 adj. -6-5 -4 - - - + + + +4 +5 +6 - -- -4-5 -6 Set Point adj. = 9.5.. Set-Point values, range 4-0 ma (Transducer 4-0 ma) 4-0mA 4 56 7 8 9 0 The Set-Point value is the result of +/- adj. + ++ +4 +5 +6 adj. 7,00 7,05 7,5 7,5 7,5 7,45 7,56 7,66 7,76 7,86 7,96 8,06 8, 7,5 7,56 7,66 7,76 7,86 7,96 8,06 8,6 8,6 8,6 8,46 8,56 8,6 8,5 8,56 8,66 8,76 8,86 8,96 9,06 9,6 9,6 9,6 9,46 9,56 9,6 9,5 9,56 9,66 9,76 9,86 9,96 4 0,06 0,6 0,6 0,6 0,46 0,56 0,6 0,5 0,56 0,67 0,77 0,87 0,97 5,07,7,7,7,47,57,6,5,57,67,77,87,97 6,07,7,7,7,47,57,6,5,57,67,77,87,97 7,07,7,7,7,47,57,6,5,57,67,78,88,98 8 4,08 4,8 4,8 4,8 4,48 4,58 4,6 4,5 4,58 4,68 4,78 4,88 4,98 9 5,08 5,8 5,8 5,8 5,48 5,58 5,6 5,5 5,58 5,68 5,78 5,88 5,98 0 6,08 6,8 6,8 6,8 6,48 6,58 6,6 6,5 6,58 6,68 6,78 6,88 6,99 7,09 7,9 7,9 7,9 7,49 7,59 7,64 7,54 7,59 7,69 7,79 7,89 7,99 8,09 8,9 8,9 8,9 8,49 8,59 8,64 8,04 8,09 8,9 8,9 8,9 8,49 8,59 8,69 8,79 8,89 8,99 9,09 9,4 9.5.. Set-Point values, range 0-5 bar (Transducer 4-0 ma) 0-5 bar -6-5 -4 - - - + + + +4 +5 +6 + ++ +4 +5 +6 adj.,8,86,96,05,4,4,,4,5,6,7,80,85,9,,4,5,6,7,80,90,99 4,09 4,8 4,7 4, 4, 4,7 4,7 4,46 4,56 4,65 4,74 4,84 4,9 5,0 5, 5, 5,6 5,7 5, 5, 5,40 5,50 5,59 4 5,68 5,78 5,87 5,97 6,06 6,5 6,0 6, 6,5 6,5 6,4 6,44 6,5 5 6,6 6,7 6,8 6,9 7,00 7,09 7,4 7,05 7,09 7,9 7,8 7,8 7,47 6 7,57 7,66 7,75 7,85 7,94 8,04 8,08 7,99 8,04 8, 8, 8, 8,4 7 8,5 8,60 8,69 8,79 8,88 8,98 9,0 8,9 8,98 9,07 9,6 9,6 9,5 8 9,45 9,54 9,6 9,7 9,8 9,9 9,96 9,87 9,9 0,0 0,0 0,0 0,9 9 0,9 0,48 0,57 0,67 0,76 0,86 0,90 0,8 0,86 0,95,05,4, 0,,4,5,6,70,80,84,75,80,89,99,08,7,7,6,46,55,64,74,79 6

,69,74,8,9,0,,,0,40,49,58,68,7,6,,0,40,49,58,68,77,87,96 4,05 4,5 4,0 9.5.. Set Point values, range 0-5 bar (Transducer 4-0 ma) - -- -4-5 -6 adj. 0-5 bar 4 56 7-6 -5-4 - - - + + + +4 +5 +6 8 9 0 + ++ +4 +5 +6 adj. 4,69 4,77 4,9 5,08 5,4 5,40 5,55 5,7 5,87 6,0 6,8 6,4 6,4 5,48 5,55 5,7 5,87 6,0 6,8 6,4 6,50 6,65 6,8 6,97 7, 7,0 7,04 7, 7,8 7,44 7,59 7,75 7,9 8,06 8, 8,8 8,5 8,69 8,77 8,6 8,69 8,85 9,00 9,6 9, 4 9,47 9,6 9,79 9,94 0,0 0,6 0,4 0,8 0,6 0,4 0,57 0,7 0,88 5,04,0,5,5,67,8,90,75,8,98,4,0,45 6,6,77,9,08,4,9,47,,9,55,7,86 4,0 7 4,8 4, 4,49 4,65 4,80 4,96 5,04 4,88 4,96 5, 5,7 5,4 5,59 8 5,74 5,90 6,06 6, 6,7 6,5 6,6 6,45 6,5 6,68 6,84 7,00 7,5 9 7, 7,47 7,6 7,78 7,94 8,09 8,7 8,0 8,09 8,5 8,4 8,57 8,7 0 8,88 9,04 9,9 9,5 9,5 9,66 9,74 9,58 9,66 9,8 9,98 0, 0,9 0,45 0,60 0,76 0,9,07,,,5,,9,54,70,86,0,7,,48,64,80,88,94,0,7,,48,64,80,95,,7,4,58,66 9.5.4. Set Point values, range 0-0 bar (Transducer 4-0 ma) - -- -4-5 -6 adj. 0-0 bar 4 56 7-6 -5-4 - - - + + + +4 +5 +6 8 9 0 + ++ +4 +5 +6 adj. 5,6 5,7 5,9 6,0 6,9 6,48 6,67 6,85 7,04 7, 7,4 7,6 7,70 6,57 6,67 6,85 7,04 7, 7,4 7,6 7,79 7,98 8,7 8,6 8,55 8,64 8,45 8,55 8,74 8,9 9, 9,0 9,49 9,68 9,86 0,05 0,4 0,4 0,5 0, 0,4 0,6 0,80 0,99,8 4,7,56,74,9,,,40,,,50,69,87,06 5,5,44,6,8 4,00 4,9 4,8 4,0 4,9 4,8 4,57 4,75 4,94 6 5, 5, 5,5 5,69 5,88 6,07 6,7 5,98 6,07 6,6 6,45 6,64 6,8 7 7,0 7,0 7,9 7,58 7,76 7,95 8,05 7,86 7,95 8,4 8, 8,5 8,70 8 8,89 9,08 9,7 9,46 9,64 9,8 9,9 9,74 9,8 0,0 0, 0,40 0,59 9 0,77 0,96,5,4,5,7,8,6,7,90,09,8,47 0,65,84,0,,4,59,69,50,59,78,97 4,6 4,5 4,54 4,7 4,9 5,0 5,9 5,48 5,57 5,8 5,48 5,66 5,85 6,04 6, 6,4 6,60 6,79 6,98 7,7 7,6 7,45 6, 6,4 6,60 6,79 6,98 7,7 7,6 7,55 7,7 7,9 8, 8,0 8,9 7

9.5.5. Set-Point values, range 0-45 bar (Transducer 4-0 ma) - -- -4-5 -6 adj. 0-45 bar 4 56 7-6 -5-4 - - - + + + +4 +5 +6 8 9 0 + ++ +4 +5 +6 adj. 8,45 8,59 8,87 9,5 9,4 9,7 0,00 0,8 0,56 0,85,,4,55 9,86 0,00 0,8 0,56 0,85,,4,69,97,6,54,8,96,68,8,0,8,67,95 4, 4,5 4,80 5,08 5,6 5,64 5,78 5,50 5,64 5,9 6, 6,49 6,77 4 7,05 7, 7,6 7,90 8,8 8,46 8,60 8, 8,46 8,75 9,0 9, 9,59 5 9,87 0,6 0,44 0,7,00,8,4,4,8,57,85,,4 6,70,98,6,54,8 4, 4,5,97 4, 4,9 4,67 4,95 5,4 7 5,5 5,80 6,08 6,6 6,65 6,9 7,07 6,79 6,9 7, 7,49 7,77 8,06 8 8,4 8,6 8,90 9,9 9,47 9,75 9,89 9,6 9,75 0,0 0, 0,60 0,88 9,6,44,7,0,9,57,7,4,57,85,4,4,70 0,98 4,6 4,55 4,8 5, 5,9 5,5 5,5 5,9 5,67 5,96 6,4 6,5 6,80 7,09 7,7 7,65 7,9 8, 8,6 8,07 8, 8,50 8,78 9,06 9,4 9,6 9,9 40,9 40,47 40,75 4,04 4,8 9,48 9,6 9,9 40,9 40,47 40,75 4,04 4, 4,60 4,88 4,6 4,45 4,59 9.5.6. Set Point values, range 0-0 bar (Transducer 0,5-4,5 Vdc) - -- -4-5 -6 adj. 0-0 bar 4 56 7-6 -5-4 - - - + + + +4 +5 +6 8 9 0 + ++ +4 +5 +6 adj.,0,,47,7,96 4,0 4,45 4,69 4,94 5,8 5,4 5,67 5,79 4, 4,45 4,69 4,94 5,8 5,4 5,67 5,9 6,6 6,4 6,65 6,89 7,0 6,77 6,89 7,4 7,8 7,6 7,87 8, 8,6 8,6 8,85 9,0 9,4 9,47 9, 9,4 9,59 9,8 0,08 0, 4 0,57 0,8,06,0,55,79,9,67,79,04,8,5,77 5,0,6,5,75 4,00 4,4 4,6 4, 4,4 4,49 4,7 4,97 5, 6 5,46 5,7 5,95 6,0 6,44 6,69 6,8 6,57 6,69 6,9 7,8 7,4 7,67 7 7,9 8,6 8,40 8,65 8,89 9,4 9,6 9,0 9,4 9,8 9,6 9,87 0, 8 0,6 0,6 0,85,0,4,59,7,46,59,8,08,,56 9,8,05,0,54,79 4,0 4,6,9 4,0 4,8 4,5 4,77 5,0 0 5,6 5,50 5,75 5,99 6,4 6,48 6,60 6,6 6,48 6,7 6,97 7, 7,46 7,7 7,95 8,0 8,44 8,69 8,9 9,05 8,8 8,9 9,8 9,4 9,67 9,9 0,5 0,40 0,64 0,89,,8,50 0,0 0,5 0,40 0,64 0,89,,8,6,87,,6,60,7 8

9.5.7. Set-Point values, range 0 C to 60 C (NTC probe 0kohm@5 C) - -- -4-5 -6 adj. 0-60 C 4 56 7-6 -5-4 - - - + + + +4 +5 +6 8 9 0 + ++ +4 +5 +6 adj.,00,50,00,50 4,00 4,50 5 5,50 6,00 6,50 7,00 7,50 8,00 7,00 7,50 8,00 8,50 9,00 9,50 0 0,50,00,50,00,50,00,00,50,00,50 4,00 4,50 5 5,50 6,00 6,50 7,00 7,50 8,00 7,00 7,50 8,00 8,50 9,00 9,50 4 0 0,50,00,50,00,50,00,00,50,00,50 4,00 4,50 5 5 5,50 6,00 6,50 7,00 7,50 8,00 7,00 7,50 8,00 8,50 9,00 9,50 6 0 0,50,00,50,00,50,00,00,50,00,50 4,00 4,50 7 5 5,50 6,00 6,50 7,00 7,50 8,00 7,00 7,50 8,00 8,50 9,00 9,50 8 40 40,50 4,00 4,50 4,00 4,50 4,00 4,00 4,50 4,00 4,50 44,00 44,50 9 45 45,50 46,00 46,50 47,00 47,50 48,00 47,00 47,50 48,00 48,50 49,00 49,50 0 50 50,50 5,00 5,50 5,00 5,50 5,00 5,00 5,50 5,00 5,50 54,00 54,50 55 55,50 56,00 56,50 57,00 57,50 58,00 57,00 57,50 58,00 58,50 59,00 59,50 60 60,50 6,00 6,50 6,00 6,50 6,00 6,00 6,50 6,00 6,50 64,00 64,50 65 65,50 66,00 66,50 67,00 67,50 68,00 9.6. Regulation with Double SET-Point (optional) The controller ESY- has been designed to be connected to an optional card with the Double Set-Point function, which allows to determine two operating points: &. The inclusion of the optional card is factory preset and must be requested when placing the order. In order to select the CUT-OFF / MIN out and MAX out values, follow the indications given in the table above. For the selection of Set-Point & use the input + GND on the terminal block, as indicated below. 5 4 6 7 8 9 0 MAX OUT 4 5 6 7 8 9 0 5 4 6 7 8 9 0 CUT-OFF (MIN OUT) +/- +/- 4 7 8 5 6 9 0 7 8 90 4 5 6 + ++ - -- -4 +4-5 +5-6 +6 adj. ++ - -- + -4 +4-5 +5-6 +6 adj. ++ - -- + -4 +4-5 +5-6 +6 adj. +0V Gnd MAX OUT Maximum RPM/VAC limit MIN OUT Minimum RPM/VAC or Cut-Off limit 4 adj. adj. 5 6 7 8 9 0 Main Set-Point (see following tables for position / value correspondence) Set-Point accurate adjustment (see following tables for position / value correspondence) Set-Point (see following tables for position / value correspondence) Set-Point accurate adjustment (see following tables for position / value correspondence) In order to pass from Set-Point to Set-Point, it is necessary to close the preset contact between terminals. SET-POINT operation SET-POINT operation + ++ - -- -4 +4-5 +5-6 +6 adj. +0V Gnd adj. Set-Point Set-Point Set-Point adjustment Led Led = ON OPEN OUT adj. Set-Point adjustment Led Led = ON CLOSED OUT 9

0. Function diagrams & Operating parameters in MASTER & SLAVE modes Standard values of the proportional band (Pb): transducer 4-0 ma Pb=.5 ma, transducer 0-5 Vdc Pb=0,65 Vdc, sensor NTC 0kohm@5 C Pb=7.0 C MAX=fans maximum rpm - Min= fans minimum rpm - Off= fans off - Vac= voltage supply to the load; 0.. ESY- MASTER mode 0.. ESY- SLAVE mode 0

. ACCESSORIES.. Manual Remote Control Units Series of potentiometers for manual remote control - Potentiometer for external remote control - Manual speed setting with 0-0 Vdc - Available & 0 turn versions, with standard knob and silk screen label - Available 0 turn version, with knob 0 with 00 Set-points - Mounting in switch cabinet doors, shaft length 5 mm, 6. mm - Complete with front plate 50 x 50 mm Linear potentiometer for 0-0 Vdc remote manual control turn 0kohm W in Cermet ZC RGF PB04 00000 Front plate with silk screen label 50 x 50 mm and knob diameter ZC RGF PB050 0000 with knob ZC RGF PB05 0000 with knob ZC RGF PB040 0000 with knob Linear potentiometer for 0-0 Vdc remote manual control 0 turns 0kohm W wire Front plate with silk screen label 50 x 50 mm AC voltage converter for manual control: Input 4Vdc >>> Output 0-0Vdc with adjustable MAX Vdc-Out LIMIT, for the regulation of: - Fan motors - Geared motors for shutters - Geared motors for motorized valves Front plate with silk screen label 50 x 50 mm AC voltage converter for manual control: Input 4Vdc >>> Output 4-0mA for the regulation of: - Fan motors - Geared motors for shutters - Geared motors for motorized valves Front plate with silk screen label 50 x 50 mm ZC RGF PB050 0000 with 00-points, 0 knob ZC RGF PB05 0000 with 00-points, 0 knob ZC RGF PB040 0000 with 00-points, 0 knob

. Pressure Transducer for 4-0 ma & 0-5 V Description 4-0 ma 0-5 Vdc Control signal 4 0 ma 0,5 4,5 V Power supply 8 8 V 5 V +/- 0,5V Range (bar) 0 5/5/0/45 0 0/45 Linearity < 0,5 % FS max Temperature compensation 0 50 C Electrical connection wires wires Mechanical connection 7/ 6" - 0 UNF Protection IP 65. Temperature Probe NTC (0 kohm@5 C) Sensor Connection Terminal Work range ( C) NTC probe with resinated terminal Silicon (light blue).0 mt cable INOX AISI 04 6 x 40 mm. 50 T 0.4 RGF-MEI(4) / UNIVERSAL input Expansion Module Electronic All-Round unit for the connection of 4 additional control and regulation inputs, for all applications with: Control inputs: 4-0mA, NTC(0k), 0-5Vdc, 0-0Vdc, 0-0mA Regulation output: 0-0 Vdc / 0-0 ma Selectable MASTER-SLAVE function for: - NTC Temperature, Pressure, Remote signals, etc. - Automatic selection between the MAX/MIN values - OUTPUT connection to other MEI units (max ) - LEDs for the visualization of active inputs - Power supply protection with fuse - Power supply surge protection - INPUT total protection against short-circuit - Protection filters against input signal surge

TECHNICAL ASSISTANCE FORM. All ESY- equipments are guaranteed for 6 months from the date of testing.. The guarantee will be rendered invalid under these circumstances: evidence of tampering with the mechanical or electrical parts improper use incorrect installation external electrical causes Please keep this sheet close to the 'ESY-' regulator. To improve the assistance service and quick fault diagnosis, please fill this sheet in and send it to the Assistance centre together with the regulator in the event of a breakdown. Customer: Regulator model: N di serial no: Date of installation: Date of breakdown: Description of the anomaly Noisy motor Burnt motor Burnt power supply fuse Unbalanced phases Protection interrupt phase R+N phase S+N phase T+N Blocked motor Differential interrupt Description: Control and contacts check card Soft-Start de INPUT NTC Contact DIR/REV S Prop.Band Pb Lim.Max. Out. Hi Contact Stop S Set-point Lim.Min. Out. Lo Contact / S Cut-off So Thermal contact TK INPUT 4/0 ma Transducer Supply 4 Vdc / 40mA INPUT 0/5 Vdc Input IN Potentiometer Supply 0Vdc / 5mA INPUT 0/0 Vdc Input IN RL / / Manufacturer: Charatteristics of the connected load Type fans electric resistors Electrical data VAC Amp Start Amp Code Motor data Anomaly electrical data Electrical connection star delta phase R N V Amp Traction direct belt driven phase S N V Amp Mechanics helical centrifugal phase T N V Amp Operator name: Company stamp:

Via P. G. Piamarta, 5/ Tel. (+9) 00.686 info@selproweb.com 50 Bagnolo Mella (Bs) Fax (+9) 00.674 4