Development of the LBNL Positron Emission Mammography Camera

Similar documents
Characterization of a 64 Channel PET Detector Using Photodiodes for Crystal Identification *

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

Monte Carlo Simulation Study of a Dual-Plate PET Camera Dedicated to Breast Cancer Imaging

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Performance measurements of a depth-encoding PET detector module based on positionsensitive

First Applications of the YAPPET Small Animal Scanner

Investigation of low noise, low cost readout electronics for high sensitivity PET systems based on Avalanche Photodiode arrays

Design Studies of A High-Performance Onboard Positron Emission Tomography For Integrated Small Animal PET/CT/RT Radiation Research Systems

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

60 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY /$ IEEE

An innovative detector concept for hybrid 4D-PET/MRI Imaging

SOLID state photodiode and avalanche photodiode scintillation

A Compact 16-Module Camera Using 64-Pixel CsI(Tl)/Si PIN Photodiode Imaging Modules

Design Studies for a PET Detector Module Using a PIN Photodiode to Measure Depth of Interaction

764 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 3, JUNE 2004

Initial evaluation of the Indiana small animal PET scanner

Lawrence Berkeley National Laboratory Recent Work

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 1, FEBRUARY

2594 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 5, OCTOBER /$ IEEE

Combined micropet /MR System: Performance Assessment of the Full PET Ring with Split Gradients 4.8

A PET detector module using FPGA-only MVT digitizers

A high energy gamma camera using a multiple hole collimator

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE Investigation of the Block Effect on Spatial Resolution in PET Detectors

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

PET Performance Evaluation of MADPET4: A Small Animal PET Insert for a 7-T MRI Scanner

Thomas Frach, Member, IEEE, Walter Ruetten, Member, IEEE, Klaus Fiedler, Gunnar Maehlum, Member, IEEE, Torsten Solf, and Andreas Thon

Simulations of the J-PET detector response with the GATE package

Development of PET using 4 4 Array of Large Size Geiger-mode Avalanche Photodiode

Effects of Dark Counts on Digital Silicon Photomultipliers Performance

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation

Design of a High Resolution and High Sensitivity Scintillation Crystal Array with Nearly Perfect Light Collection

Development of a simplified readout for a compact gamma camera based on 2 2 H8500 multi-anode PSPMT array

APD Quantum Efficiency

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodiodes

Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection

4 Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array

P ILC A. Calcaterra (Resp.), L. Daniello (Tecn.), R. de Sangro, G. Finocchiaro, P. Patteri, M. Piccolo, M. Rama

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

A High-Resolution GSO-based Brain PET Camera

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option

Celesteion Time-of-Flight Technology

Study of a Prototype VP-PET Imaging System Based on highly. Pixelated CdZnTe Detectors

Noise Characteristics of the FORE+OSEM(DB) Reconstruction Method for the MiCES PET Scanner

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector *

TITLE: Commissioning and Characterization of a Dedicated High-Resolution Breast PET Camera

Simulation of Algorithms for Pulse Timing in FPGAs

Highlights of Poster Session I: SiPMs

Arrays of digital Silicon Photomultipliers Intrinsic performance and Application to Scintillator Readout

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

DISCRETE crystal detector modules have traditionally been

Conceptual Study of Brain Dedicated PET Improving Sensitivity

Traditional analog QDC chain and Digital Pulse Processing [1]

Chiara Secco. PET Performance measurements of the new LSO-Based Whole Body PET/CT. Scanner biograph 16 HI-REZ using the NEMA NU Standard.

PROGRESS in TOF PET timing resolution continues to

Pixel hybrid photon detectors

Digital trigger system for the RED-100 detector based on the unit in VME standard

Index terms: PET, Silicon Photo-multiplier, Small Animal PET insert for MRI scanner. Size: 1.2x1.2 mm, Pitch: mm Thickness: 4 mm

Cross-Strip Multiplexed Electro-Optical Coupled Scintillation Detector for Integrated PET/MRI

Performance Evaluation of SiPM Detectors for PET Imaging in the Presence of Magnetic Fields

NIH Public Access Author Manuscript Nucl Instrum Methods Phys Res A. Author manuscript; available in PMC 2007 December 14.

Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Electronic Instrumentation for Radiation Detection Systems

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Over the past decade, many small-animal PET scanners

Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications

Design Evaluation of A-PET: A High Sensitivity Animal PET Camera

A Novel Design of a High-Resolution Hodoscope for the Hall D Tagger Based on Scintillating Fibers

Monitoring LSO/LYSO Based Crystal Calorimeters

The development of high-resolution PET systems has

High-resolution PET scanners dedicated to small-animal

CHAPTER 8 GENERIC PERFORMANCE MEASURES

Currently, the spatial resolution of most dedicated smallanimal

Fundamentals of Positron Emission Tomography (PET)

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Photomultiplier Tube

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

Final Report Data Acquisition Box

Data Acquisition System for the Angra Project

The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance

arxiv: v1 [physics.med-ph] 29 Nov 2018

PoS(PhotoDet 2012)016

Total Absorption Dual Readout Calorimetry R&D

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

Improving the Collection Efficiency of Raman Scattering

arxiv: v2 [physics.ins-det] 14 Jan 2009

... In vivo imaging in Nuclear Medicine. 1957: Anger camera (X;Y) X Y

Positron Emission Tomography

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

NM Module Section 2 6 th Edition Christian, Ch. 3

PET has evolved from a research tool for studying

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector

A NOVEL FPGA-BASED DIGITAL APPROACH TO NEUTRON/ -RAY PULSE ACQUISITION AND DISCRIMINATION IN SCINTILLATORS

Transcription:

Development of the LBNL Positron Emission Mammography Camera J.S. Huber, Member, IEEE, W.S. Choong, Member, IEEE, J. Wang, Member, IEEE, J.S. Maltz, Member, IEEE, J. Qi, Member, IEEE, E. Mandelli, Member, IEEE, and W.W. Moses, Senior Member, IEEE. Abstract--We present the construction status of the LBNL Positron Emission Mammography (PEM) camera, which utilizes a PET detector module with depth of interaction measurement consisting of 64 LSO crystals (3x3x30 mm 3 ) coupled on one end to a single photomultiplier tube (PMT) and on the opposite end to a 64 pixel array of silicon photodiodes (PDs). The PMT provides an accurate timing pulse, the PDs identify the crystal of interaction, the sum provides a total energy signal, and the PD/(PD+PMT) ratio determines the depth of interaction. We have completed construction of all 42 PEM detector modules. All data acquisition electronics have been completed, fully tested and loaded onto the gantry. We have demonstrated that all functions of the custom IC work using the production rigid-flex boards and data acquisition system. Preliminary detector module characterization and coincidence data have been taken using the production system, including initial images. T I. INTRODUCTION his paper describes the status and construction of the LBNL Positron Emission Mammography (PEM) camera [1]. The geometry for the PEM camera is shown in Fig. 1. The breast is inserted in the gap between the top and bottom 7.5 x 10 cm 2 detector planes, and the spacing between planes adjusted to provide light compression on the breast. The positions of the 7.5 x 7.5 cm 2 detector planes on the left and right of the breast are fixed. The volumes represent the active portion of the detector (i.e., the portion sensitive to 511 kev photons), which are divided into 2.5 x 2.5 x 3.0 cm 3 modules. Each module is further divided into 64 individual LSO scintillation crystals, each 3 x 3 x 30 mm 3. We have currently instrumented only the two side (7.5 x 7.5 cm 2 ) detector planes, using 18 detector modules, which are shown in Fig. 1 as dark gray. We have previously reported on a PET detector module capable of measuring depth of interaction on an event by event basis [2, 3], shown in Fig. 2. With this design, a single photomultiplier tube (PMT) provides an accurate timing pulse and initial energy discrimination for an 8 x 8 array of LSO [4] scintillator crystals, an 8 x 8 silicon Manuscript received December, 2002. This work was supported in part by the U.S. Department of Energy under contract No. DE-AC03-76SF00098, in part by Public Health Service Grant Nos. P01-HL25840, RO1-CA67911, and RO1-NS29655, and in part by Breast Cancer Research Program of the University of California Grant no 1RB-0068. J. S. Huber, W. S. Choong, J. Wang, J. S. Maltz, J. Qi, E. Mandelli, and W. W. are with the Lawrence Berkeley National Laboratory, Mailstop 55-121, 1 Cyclotron Road, Berkeley, CA 94720 USA (telephone: 510-486- 6445, e-mail: jshuber@lbl.gov). photodiode array (PDs) identifies the crystal of interaction, the PD/(PD+PMT) ratio measures the depth of interaction, and the sum (PD+PMT) provides a total energy signal. We are planning to use this PET detector module in several tomograph designs [1, 5, 6]; thus we have transformed our prototype detector into one that can be produced in quantity. We focus in this paper on new results using production versions of the complete system -- custom ICs, rigid-flex boards (used to read out the IC), detector modules, and data acquisition system. The major milestone of reading out coincidence data with the production system has been achieved, and initial images are shown. II. SYSTEM A. Modules We have built all 42 production detector modules to be used in our PEM camera design [1]. Fig. 2 shows a photograph of one production detector module. The end-on profile of the module is 2.5 cm square, allowing close packing of multiple detector modules in two dimensions. Communication between the custom integrated circuit (PETRIC) [7] and the remainder of the electronics [8] (which is located behind the photomultiplier tube) is accomplished by a 0.008 thick Kapton flex tail on the IC printed circuit board that is thin enough to run between adjacent detector modules. The successful production of these rigid-flex boards has proved to be a surprisingly difficult task, but we are now taking data using the working, final versions of the rigid-flex boards. All functions of the PETRIC chip (including the Winner-Take-All circuitry for correct analog and channel address selection of the "winner") have been demonstrated to work with production rigid-flex boards and the final data acquisition system. Fig. 3 demonstrates that the detector module assembly process is complete. We are now in the process of attaching rigid-flex boards onto each detector module s photodiode, as well as bundling three detector modules (with rigid-flex boards) and assembling them into light tight cans. Fig. 4 shows the details of our can assembly. Currently, half of the detector modules have been assembled into cans. B. Camera We have instrumented the two side (7.5 x 7.5 cm 2 ) detector planes, using 18 detector modules (i.e., 3 detector

cans per bank). Fig. 5 shows the camera gantry and electronics housing before the modules were put in place. The detector modules are read out with electronics originally developed by CTI (Knoxville, TN) for the HRRT brain imaging PET camera and modified to use a detector module that incorporates a photodiode [8]. The top level diagram of the electronics system is show in Fig. 6a, and the diagram of the Head Interface (DHI) board is shown in Fig. 6b. The outputs of three detector modules are processed by an board. Events are detected and assigned an arrival time, the crystal of interaction is identified, energy qualification is performed, and a digital word is formed. The output signals from the boards are then multiplexed by Head Interface boards. A CTI Coincidence Processor identifies singles events in the different DHI boards that are in coincidence, and the output is sent to a Pentium-based computer system that accumulates the coincident data, reconstructs the images, and displays them. This final data acquisition system was used to calibrate the detector modules. We have automated calibration software that sets up the electronics and identifies bad channels using test pulses. In addition, we have automated software that acquires (singles or coincidence) data with a 68 Ge source (using the PMT signal with a low discriminator threshold for triggering), corrects for channel to channel gain variation in the PMT signal, and cuts events with PMT signal outside the 350-700 kev energy window. However, we currently have not corrected for channel to channel gain variation in the PD signal, and have not scaled the relative PD and PMT signal; thus we have not yet been able to calculate the depth of interaction (DOI) with the production system. Since the calibration procedure is not complete [9], the PD is only used to identify the crystal of interaction. C. Reconstruction We have developed and tested both filtered backprojection reconstruction algorithms (2-D [10] and 3-D [11]) and a list mode regularized maximum likelihood reconstruction algorithm [12] using Monte Carlo data. The rectangular geometry and the capability of measuring DOI result in irregular sampling in the sinogram space. In the filtered backprojection algorithm, data are rebinned onto regular grid. In the list mode maximum likelihood algorithm, the irregular sampling and DOI information are explicitly modeled in the projection matrix. To demonstrate the expected system performance, Fig. 7 shows a reconstructed image of simulated spherical sources using the 3D filtered backprojection algorithm. The resolution of the reconstruction varies from 1.54 mm FWHM at the center to 3.10 mm at the corner. As the current camera setup only contains two opposing detector banks, the filtered backprojection algorithm is not directly applicable. Therefore, in Section III we only show the list mode maximum likelihood reconstruction of the real data. III. RESULTS The two instrumented detector banks were used to image 68 Ge sources in two different configurations, as shown in Fig. 8. The distance between the opposing detector banks was 7 cm. In the first setup, a 1.5 mm diameter 68 Ge point source (106 µci) was placed in the mid-plane between the two planar detector banks. Data was taken at two different point source positions (Fig. 8a), resulting in 10M events each. The images, shown in Fig. 9, were reconstructed with the maximum likelihood algorithm using 1.5 x 1.5 x 3 mm 3 voxels. Normalization factors were measured using a plane source placed in the mid-plane. The reconstructed point in position 1, as shown in Fig. 9a, has a (1.65, 2.85) mm FWHM reconstruction resolution. In position 2, the reconstruction resolution is (2.40, 1.95) mm FWHM. The variation in FWHM is mostly caused by the misalignment between the point source position and the voxel grid. The non-negativity constraint in the maximum likelihood reconstruction did not have a big impact on the resolution measurement here, as we obtained similar results when we reconstructed the point source data after superimposing it with a simulated uniform background. In the second setup, a point and rod source in different planes were used. The 1.5 mm diameter 68 Ge point source (106 µci) was placed in the mid-plane and a 2.5 mm diameter rod source (118 µci) was placed in a plane that was 2 cm apart (Fig. 8b). Fig. 10 shows the images of the rod and point source with 10M events. The point source has (3.00, 2.25) mm FWHM reconstruction resolution. Since the concentration of activity in the point source is much stronger than the rod source, background activity in the area of the point source is seen in the rod source plane. Fig. 11 shows the spectra of the timing difference between two production detector modules, which were read out with the final data acquisition system. Data was taken using the 1.5 mm diameter 68 Ge point source (106 µci) placed in the mid-plane between the two detector modules. Only the PMT information was used, with a low energy threshold. While channel to channel corrections are planned, none were used to acquire these data. The preliminary coincidence timing resolution of 4.8 nsec is expected to improve after timing calibration is complete. IV. DISCUSSION AND CONCLUSION Two significant tasks remain before this camera is complete: assembly of the remaining two detector banks needs to be finished and the remainder of the calibration algorithms (especially PD) needs to be developed. However, we feel that major milestones have been achieved with our system. All components are complete -- custom ICs, flex boards, detector modules, data acquisition electronics and the gantry. Production firmware and calibration has been developed. Most importantly, the first images have been acquired using two opposing banks of 3x3 modules each. Initial reconstruction resolutions are in agreement with expectation. V. ACKNOWLEDGMENT This work was supported in part by U.S. Department of Energy under contract No. DE-AC03-76SF00098, and in part

by the Public Health Service Grant Nos. P01-HL25840 and R01-CA67911. Reference to a company or product name does not imply approval or recommendation by the University of California or the U.S. Department of Energy to the exclusion of others that may be suitable. VI. REFERENCES 1. W. W. Moses, T. F. Budinger, R. H. Huesman, et al., PET camera designs for imaging breast cancer and axillary node involvement, J Nucl Med, vol. 36, pp. 69P (abstract), 1995. 2. J. S. Huber, W. W. Moses, S. E. Derenzo, et al., Characterization of a 64 channel PET detector using photodiodes for crystal identification, IEEE Trans Nucl Sci, vol. NS-44, pp. 1197 1201, 1997. 3. J. S. Huber, W. W. Moses, M. S. Andreaco, et al., A LSO Scintillator Array for a PET Module with Depth of Interaction Measurement, IEEE Trans Nucl Sci, vol. NS-48, pp. 684-688, 2001. 4. C. L. Melcher and J. S. Schweitzer, Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator, IEEE Trans Nuc Sci, vol. 39, pp. 502-5, 1992. 5. W. W. Moses, P. R. G. Virador, S. E. Derenzo, et al., Design of a high-resolution, high-sensitivity PET camera for human brains and small animals, IEEE Trans. Nucl. Sci., vol. NS-44, pp. 1487-1491, 1997. 6. J. S. Huber and W. W. Moses, Conceptual design of a high sensitivity small animal PET camera with 4π coverage, IEEE Trans Nucl Sci, vol. NS-46, pp. 498-502, 1999. 7. M. Pedrali-Noy, G. J. Gruber, B. Krieger, et al., PETRIC - A Positron Emission Tomography Readout IC, IEEE Trans Nucl Sci, vol. NS-48, pp. 860-864, 2000. 8. W. W. Moses, J. W. Young, K. Baker, et al., The Electronics System for the LBNL Positron Emission Mammography (PEM) Camera, IEEE Trans Nucl Sci, vol. NS-48, pp. 632-636, 2001. 9. J. S. Huber, W. W. Moses, and P. R. G. Virador, Calibration of a PET detector module that measures depth of interaction, IEEE Trans Nucl Sci, vol. NS-45, pp. 1268 72, 1998. 10. P. R. G. Virador, W. W. Moses, and R. H. Huesman, Reconstruction in PET cameras with irregular sampling and depth of interaction capability, IEEE Trans Nucl Sci, vol. NS-45, pp. 1225 30, 1998. 11. P. R. G. Virador, W. W. Moses, R. H. Huesman, et al., 3D Reconstruction in PET Cameras with Irregular Sampling and Depth of Interaction, IEEE Trans. Nucl. Sci., vol. NS-48, pp. 1524-1529, 2001. 12. R. H. Huesman, G. J. Klein, W. W. Moses, et al., List mode maximum likelihood reconstruction applied to positron emission mammography with irregular sampling., IEEE Trans Med Imag, vol. 19, pp. 532-537, 2000.

Figures: 7.5 cm 10 cm 7.5 cm Fig. 1. Positron Emission Mammography (PEM) camera [1]. The breast is inserted in the gap between the top and bottom 7.5 x 10 cm 2 detector planes, and the spacing between planes adjusted to provide light compression on the breast. The positions of the 7.5 x 7.5 cm 2 detector planes on the left and right of the breast are fixed. The volumes represent the active portion of the detector (i.e., the portion sensitive to 511 kev photons), which are divided into 2.5 x 2.5 x 3.0 cm 3 modules. We have currently instrumented only the two side (7.5 cm x 7.5 cm) detector planes, using 18 detector modules, which are shown in dark gray. Fig. 4. Photograph of the detector can assembly. Rigid-flex boards are attached to each detector module s photodiode. Three detector modules are then attached to a high voltage distribution board and assembled into a light-tight can. (a) (b) Fig. 2. Photograph of the PET detector. Each crystal is attached to a photomultiplier tube which provides timing and initial energy information, and to a photodiode which identifies the crystal of interaction. The PMT and PD signals are combined to measure the depth of interaction and total energy. The custom integrated circuit is mounted on a 2.5 cm square circuit board with a 0.008" thick Kapton tail, which goes between adjacent detector modules and acts as a cable connecting the IC to the remainder of the readout electronics. Fig. 5. (a) A photograph of the actual PEM gantry which is fully loaded with the complete data acquisition electronics (but not loaded with detector modules). Each detector bank utilizes nine (side bank) or twelve (top/bottom bank) detector modules. The detector modules are loaded into a can (Fig 4) with the Kapton flex tail feeding out between the detector modules and connecting to the readout electronics. (b) PEM camera electronics cabinet. There is space for the computer on the bottom. The Coincidence Processor and power supplies are visible in the middle area, and the HV power panel is seen on the top. Fig. 3. Photograph of PET detector modules, demonstrating that the detector module assembly is complete. We have built all 42 detector modules that are needed for the PEM camera.

(a) RS-232 COM2 RS-485 (a) Position 2 (b) (b) Pentium To Coinc. Board Systran SLDC Rebinner Fiber Optic Link Head Interface Coincidence Processor Head Head Head Head Modules ISA Bus Position 1 2 cm Fig. 8. Geometry setup for data taking, with 68 Ge sources placed between two opposing planar detector banks. The distance between detector banks was 7 cm. (a) In the first setup, a point source in the midplane was used. Data was taken at two different point source positions. (b) In the second setup, a point and rod source in different planes were used. The point source (1.5 mm diameter, 106 µci) was in the mid-plane and the rod source (2.5 mm diameter, 118 µci) was in a plane that was 2 cm away. Fig. 6. (a) Top level diagram of the electronics system. Each of the four Head Interface boards collects singles events which are forwarded to the Coincidence Processor. Coincident events are then passed to the Pentium-based data acquisition computer via a fiber optic link to a Systran SLDC receiver. A rebinner board can optionally be placed between the Coincidence Processor and the fiber optic readout board. (b) Diagram of the Head Interface (DHI). Three detector modules are serviced by each board. The singles event words generated by the board are multiplexed by the DHI board, which also buffers communication with the as well as system timing signals [8]. Fig. 7 Simulated sphere sources located at the central plane. The spheres are arranged where the distances between the sources are four times their diameters (like a Derenzo Phantom). The diameters are 1.0 mm, 1.25 mm, 1.5 mm, and 2.0 mm. Fig. 9. Images of a 1.5 mm diameter 68 Ge point source (106 µci) placed in the mid-plane, as described in Fig. 8a. The source position was not centered on a crystal. Data was taken at two different positions. The images were reconstructed with a maximum likelihood algorithm using 10M events. The x- and y- scale are in millimeters. (a) The reconstructed point in position 1 (near the center) has a (1.65, 2.85) mm FWHM reconstruction resolution. The vertical intensity scale ranges from 0-8x10 7. (b) In position 2 (near the upper right corner), the reconstruction resolution is (2.40,1.95) mm FWHM. The vertical intensity scale ranges from 0-2x10 8.

Fig. 10. Images of the (a) 1.5 mm diameter 68 Ge point source (106 µci) placed in the mid-plane and (b) 2.5 mm diameter rod source (118 µci) placed in a different plane (2 cm away), as described in Fig. 8b. The x- and y- scale are in millimeters. The vertical intensity scale ranges from 0-5x10 7 for (a) and from 0-2.5x10 6 for (b). The reconstruction was done using 10M events. The point source has (3.00, 2.25) mm FWHM reconstruction resolution. Since the concentration of activity in the point source is much stronger than the rod source, background activity in the area of the point source is seen in the rod source plane. 100000 80000 Counts 60000 40000 FWHM = 4.8 nsec 20000 0-30 -20-10 0 10 20 30 Timing Difference (nsec) Fig. 11. The spectrum of the timing difference between two production detector modules, which were read out with the final data acquisition system. Data was taken using the 1.5 mm diameter 68 Ge point source (106 µci) placed in the mid-plane between the two detector modules. Only the PMT information was used, with a low energy threshold. No channel to channel corrections were made. The preliminary coincidence timing resolution of 4.8 nsec is expected to improve after timing calibration is complete.